KIT EEN-KIC50-12 : Cabling diagram:
Page 2 / 2 V231-0071-AB
C
ABLING FOR A DOOR CONNECT TO THE
CENTRAL
UNIT
OR
PANEL
RELAY
:
To best secure the opening of the door, connect the electric or magnet lock to the central unit's CRT relay then set switch No.2 to ON.
M
AGNET LOCK
E
LECTRIC LOCK
At rest, the magnet is powered and keeps the door locked,
When the relay is activated by the central unit, the magnet's power supply is cut; the
magnet releases the door (by pressing on a pushbutton or the use of an authorised
badge on the proximity reader).
-The electric magnet power supply voltage must be less than 42 V AC or 60 V DC.
If the power supply voltage exceeds these values, use an intermediate relay (of the
correct capacity) to control the electric lock.
At rest, the lock striker keeps the door locked,
When the relay is activated by the central unit, the electric current releases the door
striker (by pressing on a pushbutton or the use of an authorised badge on the
proximity reader).
The electric lock power supply voltage must be less than 42 V AC or 60 V DC. If
the power supply voltage exceeds these values, use an intermediate relay (of the
correct capacity) to control the electric lock.
IMPORTANT:
Proper operation and long-life are dependent on the fitting of the varistors supplied with the central unit
1. The varistor must be connected as close as possible to the electric lock or magnet
2. Free access times should be avoided for doors fitted with electric locks!
3. The varistor is 12 V.
Door
pushbutton
Magnet
Power Supply
17
18
C
R
T
V1
PANEL
Door
pushbutton
L
o
c
k
Elec. Lock
Power Supply
17
18
C
R
T
V1
PANEL
Security = Central
Door
pushbutton (NO/NC)
C R T
Magnet
Power Supply
CENTRAL
Door
pushbutton (NO/NC)
C R T
L
o
c
k
Elec. Lock
CENTRAL