Interlogix AL-4017 Installation guide

Type
Installation guide
Note: Dual Zone option is not acceptable for UL 365,
UL 609, and UL 1610.
Note: 2.2k/10kEOL configuration optional. Do not
mix EOLs values.
Note: All circuits are power limited except for standby
batteries and AC primary.
1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C 10 C 11 C 12 C 13 C 14 C 15 C 16 C
AL-4017 Alarm Inputs
Method 1 Method 2
Single Zone Dual Zone
Alarm Input Wiring Methods
4.7K
NC
NO
Alarm
Input
C
4.7K
NC
NC
Alarm
Input
C
4.7K
GE Security
1039581 Revision D 01/05
AL-4017 Wiring Diagram
Access Control and Commercial Burglar Alarm System
Refer to installation instructions, 1040731 Rev. D, for full electrical ratings.
FCC
This device complies with Part 15 of the FCC
rules. Operation is subject to the following
conditions: (1) this device may not cause
harmful interference, (2) this device must
accept any interference received, including
interference that may cause undesired
operation, and (3) changes or modifications
not expressly approved by the party
responsible for compliance could void the
user’s authority to operate the equipment.
UL Listings
UL 294 - the Standard for Access Control
System Units
UL 365 - the Standard for Police Station
Connected Burglar Alarm Units and Systems
UL 609 - the Standard for Local Burglar Alarm
Units and Systems
UL 1610 - the Standard for Central-Station
Burglar-Alarm Units
UL 1635 - the Standard for Digital Alarm
Communicator System Units
Telco Network Wiring
BX-T1
AX-R1
B-T
A-R
Refer to installation
instructions for RJ31X
wiring.
US:GEIAL07B3-4000
Ground
Telco Network Wiring
+
-
+
+
+
-
-
-
SW +
SW -
S +
S -
S +
S -
+
-
+12
OV
D +
D -
T
C
NEG
C
POS
24 VAC, AL-1690 transformer kit
Note: To maintain compliance with UL 365 and UL 609, the primary indicating device
must provide both electrical and mechanical supervision.
* Siren output must be
programed for DC output. See
programming manual for further
details.
EXT
8 ohm 15 watt
MPI - 35 or EQ
AC
BATT
AUX. POWER
INT
STRB
COMMS
TAMPER
BELL (Relay Output)
Note: Do not short circuit.
Note: AL-4017 Total AUX
POWER output 300ma,
including “+12” on COMMS”.
For use with an auxiiary power
supply, please refer to
installation instructions.
Alarm output 1 Amp total
Note: The first and last device
on the system bus (COMMS)
must be terminated. See device
installation for further details.
Ademco *
AB12M
Grade A
1K
Strobe
AL-11XX
or other
(BUS)(LAN)
(COMM)
Device
Note: These are dry contacts.
Note: Refer to “Battery
Calculation Worksheet” for
appropriate battery type.
Change the battery every four to
five years.
12V
Note: Use 1K resistor if bell or
siren is not used.
12V
Link
To AL-1206 zone
expansion module
To AL-1810/AL-1813
relay output module