2
DTP T 3G-SDI D Series • Setup Guide (Continued)
D RS-232 and IR Over TP — Plug an RS-232 or modulated IR device into
this RS-232 and IR Over TP pass-through port. Wire the cable as shown
to the right.
E USB Config port — Connect a PC to this USB mini-B port for device
conguration and rmware updates.
F TP Out connector — Connect the rear panel transmitter output (see
F
on page 1) to the rear panel receiver input using
shielded twisted pair (STP) cable.
ATTENTION:
• Do not connect these outputs to a telecommunications or computer data network.
• Ne connectez pas ces appareils à des données informatiques ou à un réseau de télécommunications.
• Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.
• N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF d’Extron ou le câble STP201.
For optimal performance, Extron highly recommends the following:
• RJ-45 termination with STP cable must comply with TIA/EIA T568-B wiring standard for all connections. For more
information on cable wiring and termination, see the full product user guide at www.extron.com.
• Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.
• Use shielded RJ-45 plugs to terminate the cable.
• Limit the use of RJ-45 patches. Overall transmission distance capabilities vary
depending on the number of patches used. If possible, limit the number of
patches to a maximum of 2.
• If RJ-45 patches must be used in the system, shielded CAT 6 (or better) patches
are recommended.
G Power input connector — Plug the included external 12 VDC power supply into
either this 2-pole connector (see the illustration to the right for wiring information)
or the power input connector on the receiver (see the user guide of your respective
receiver for more information).
The unit can be powered either locally, with the included external 12 VDC power
supply, or over the DTP line by a locally powered receiver or switcher.
ATTENTION:
• Extron recommends installing the DTP T 3G-SDI D into a grounded, UL-listed electrical junction box.
• Extron recommande d’installer le DTP T 3G-SDI D dans un boîtier d’encastrement électrique mis à la terre,
listé UL.
Step 4 — Connect Outputs from the Receiver
The DTP T 3G-SDI D series is compatible with DTP 230 and DTP 330 receivers (sold separately).
a. Output connector — Connect a DisplayPort or HDMI cable between this port and the input port of the display. For
complete instructions on connecting receivers or switchers to outputs, see the user guide for the appropriate product at
www.extron.com.
b. Audio output — Connect a stereo audio device to this 3.5 mm mini stereo jack to receive the passed through
unbalanced audio.
c. RS-232 and IR Over TP connector — Plug an RS-232 or modulated IR device into the RS-232 and IR Over TP
pass-through port. Wire the connector as shown in step 3 above.
Step 5 — Final Installation
a. Make all connections and test the system for satisfactory operation.
b. At the power outlet, unplug the power supply.
c. Mount the transmitter into the wall box and attach the supplied decorator-style faceplate to the unit.
d. At the power outlet, reconnect the power supply. This can power up both the transmitter and receiver.
Ground
Transmit pin on connected unit
Receive pin on connected unit
Connected RS-232
and IR Device Pins
Receive pin on connected unit
Transmit pin on connected unit
Tx TxRx RxG
RS-232
IR
OVER TP
SECTION A–A
AA
Power Supply
Captive Screw
Connector
Ridges
Smooth
3/16"
(5 mm) Max.