wattstopper intelliswitch TS-400-24 Installation Instructions Manual

Type
Installation Instructions Manual

Wattstopper IntelliSwitch TS-400-24 is a digital time switch that can be used to automatically turn off lights after a preset amount of time, or to manually override the time-out period. Here are some additional features and possible use cases for this device:

  • Time-out period can be adjusted from 5 minutes to 12 hours.
  • Time-out override allows the user to temporarily change the time-out period without changing the original setting.
  • Visual (flash) and audible (sound) warnings can be enabled to indicate when the time-out period is about to expire.

Wattstopper IntelliSwitch TS-400-24 is a digital time switch that can be used to automatically turn off lights after a preset amount of time, or to manually override the time-out period. Here are some additional features and possible use cases for this device:

  • Time-out period can be adjusted from 5 minutes to 12 hours.
  • Time-out override allows the user to temporarily change the time-out period without changing the original setting.
  • Visual (flash) and audible (sound) warnings can be enabled to indicate when the time-out period is about to expire.
TS-400-24
InteliSwitch® Digital Time Switch
24VDC/VAC
SPECIFICATIONS
Voltages ....................... 24VAC,24VDC,VACHalfRectified
 CurrentConsumption............................Max.15mADC
........................................Max.15mAAC
Outputs
  IsolatedRelay................................1A/30VSPDT
  PulseOn/Off:
  Width.......................................150ms
Current.......................................1.5A
Time-OutAdjustment ...................... 5minutesto12hours
 Time-OutOverride ...............0to1hourin5minuteincrements
................... 1hourto12hoursin15minuteincrements
 OperatingTemperature................... 32°to104°F(0°to40°C)
 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . Rh5%to95%,non-condensing
Installation Instructions
U.S.Patent:5,640,113
UNIT DESCRIPTION AND OPERATION
The InteliSwitch®TS-400-24isadigitaltimeswitchthatautomaticallyturnslightsoffafter
apresetamountoftime.Thelightscanalsobeturnedoffanytimeduringthetimer’s
countdownbypushingtheON/OFFbutton.TheDigitalTimeSwitchhasfouruser-adjustable
features:time-outperiod,timescrolldirection,time-outvisualandaudiblewarnings.
Time-Out Period
Thetimercanbeadjustedtoholdlightsonforfiveminutesto12hours.Thedefaultsetting
is3hours.SeetheDELAYswitchadjustmenttosetthelengthofthetime-outperiod.
Time Scrolling
Theusercanmanuallyandtemporarilyoverridethetime-outperiodwithoutchangingthe
DELAYadjustment.TheSCROLLadjustmentdetermineswhethertheusersoverrideoptions
decreasefromalongertimetoashortertime(scrolldown)orincreasefromashortertime
toalongertime(scrollup).Tochoosethescrollingdirection,considerthetime-outDELAY
setting,andthenwhethertheusualtemporaryneedwillbeformoreorlesstime.
Override Operation:HoldingtheON/OFFbuttonforlongerthan4secondscausesthetimer
toscrollthroughtimeincrements,startingfromthetime-outDELAYsetting.Releasingthe
ON/OFFbuttonresumesthecountdownfromthatpoint.Theminimumoverridesettingis5
minutes,maximum12hours.
Thetimerresetsautomaticallytothetime-out
DELAYsettingwhenthecountdownrunsoutor
theON/OFFbuttonispushed.
Visual (Flash) Option
If this option is on there are two occasions
when the controlled lights flash. They flash one
timewhenthecountdownreaches5minutes
and twice when the countdown reaches 1
minute.
Audible (Sound) Option
Ifthisoptionison,thetimerbeepsevery5
secondsduringthelastminuteofthetime-out
period.
INSTALLATION
1. ConnecttheexistingwirestotheTS-400-24terminals.
For Power Pack wiring:
• +24VDCsupplyto+24VIN
• +SupplyCOmmontoCOMM
Isolated RelayusesN.O.,N.C,andRLYCOMM
terminals.
For Control Panel wiring:
• +24VACor+24VDCsupply(BLU)to+24VIN
• +SupplyCommon(WHT)toCOMM.
• On(RED)toPULSEON
• Off(BLK)toPULSEOFF
2. Mounttheswitchinthewallboxwith2mountingscrewsprovided.
3. Turnonpowertothetimeswitch
4. 5-10secondsafterpowerissuppliedtothetimeswitch,itwillbereadytofunction.
ThetimeswitchbeepsandthewordOFFappearsinthedisplay.PushtheON/OFF
switchtoactivatethelights.Thetimerbeginsitscountdown.PushtheON/OFF switch
during countdown to turn the lights off.
5. SelectfeaturesettingsusingtheSwitchAdjustmentprocedures.
6. Installcoverplate.
WIRING DIAGRAMS
WA-200.exploded
CAUTION: TURN THE POWER OFF
AT THE CIRCUIT BREAKER BEFORE WIRING.
WARNING
BE SURE THE GROUND WIRE IS SECURELY CONNECTED.
+24V IN
PULSE
OFF
PULSE
ON
N.O.
RLY
COMM.
N.C.
COMM.
InteliSwitch®
Digital Time Switch
TS-400-24
+24V IN (BLU)
COMM. (WHT)
PULSE ON (RED)
PULSE OFF (BLK)
#20/4
1000' MAX.
To Panel
Black White
To circuit
Red
On Off Comm
Blue
24VRect
ON
1
Lighting Control Panel wiring
COMM
White (Neutral)
Red
(Load)
Red (Line)
White
Black
Hot
Neut Power
Pack
Red
Black
Blue
Lighting
Load
N.O.
RLY COMM
+24V IN
ON
1
Power Pack wiring
SWITCH ADJUSTMENT
EnterSettingsModebypressingtheCalibrationButton
(locatedontheleft,behindthefaceplate).
• Ifnoinputoccurswithinfoursecondsthedisplay
flashesthenmovestothenextsetting.
• PresstheCalibrationButtontoviewthesettings
withoutmakingchanges.
• PresstheON/OFF button within four seconds to
change the setting.
DELAY: 5 min. to 12 hr.
DELAYsetsthetime-outperiod.Theselectionsbeginat
thecurrentlysettime(3hours,default).Whenthetimeis
lessthananhour,thetimeincreasesby5minuteseach
timeyoupresstheON/OFFbutton.Whenthetimeismorethananhour,
itincreasesby15minues.Whentheselectionpasses12hours,it
restartstheselectionscrollingat5minutes.
Scroll: UP or down (dn)
Tohavetheuser’stimeoverrideoptionsdecreasefromalongertimetoashortertime,set
Scroll for dn(down).Toincreasefromashortertimetoalongertime,setScrollforUP.
FLASH: ON or OFF
Sound: ON or OFF
Whenthesettingselectioniscompletetheunitwilleither:
• BeeponceanddisplayENDifthecalibrationbuttonisbeingheld;releasethebuttonto
continue.
• BeepthreetimeswhileitdisplaysEND.ThisgivesyouachancetopresstheON/OFF
button to restart the setting procedure.
Ifyoudon’tpresseitherbuttonwithinthreeseconds,theunitexitstheSettingsModeand
resumesitspreviousstate.
ON
1
TS-400-24
LCDDisplay
Call 800.879.8585 for Technical Support
WIRING
ON/OFF
Button
Calibration
Button
#16-#18 Insert wires as
shown and tighten
screw in the clock-
wise direction.
TROUBLESHOOTING
Lights will not turn on:
1. Verify that the ground wire is tightly secured.
2. If lights still do not go on, call 800.879.8585 for technical support.
Lights will not turn off:
1. Do the lights turn off when you press the ON/OFF button?
• Ifyes,checkthatthetime-outperiodissettothecorrecttime-out.Ifthetime-out
periodisadjustedtomaximum,thelightswillremainonfor12hours.
• Ifno,call800.879.8585fortechnicalsupport.
2. Totestiftheunitisoperatingproperly,setthetime-outperiodtominimum.Lights
shouldturnoffafterfiveminutes.
3. If lights still do not turn off, call 800.879.8585 for technical support.
Re-adjusting the Time-out Period:
Tore-adjustthetime-outperiod,setthenewtimedelayintheusersettings.Ifthisisdone
whilethetimeriscountingdownapriorsetting,thenewsettingwillnotberecognizeduntil
thepresentcountdownhasexpiredorthetimeristurnedOFF and ON again.
Questions/Unsure?:
Call 800.879.8585 for Technical Support.
CAUTION
TURN OFF THE POWER AT THE CIRCUIT BREAKER
BEFORE WORKING WITH HIGH VOLTAGE
Call 800.879.8585 for Technical Support
TS-400andcoverplatesareavailableinWhite(-W),LightAlmond(-A),Grey(-G),Black(-B),andIvory
(-I).
Cover plates are not included.
 TS-400-24 DigitalTimeSwitch
  24VDC/24VAC,60HZ
 ASP-211 Coverplateforsingle-gangbox
 ASP-422 Coverplatefordouble-gangbox
 ASP-432 Coverplatefordouble-gangboxwithswitchoption
ORDERING INFORMATION
WARRANTY INFORMATION
WattStopperwarrantiesitsproductstobefreeofdefectsinmaterialsandworkmanshipfor
aperiodoffiveyears.TherearenoobligationsorliabilitiesonthepartofWattStopperfor
consequentialdamagesarisingoutoforinconnectionwiththeuseorperformanceofthis
productorotherindirectdamageswithrespecttolossofproperty,revenue,orprofit,or
costofremoval,installationorreinstallation.
2800DeLaCruzBoulevard,SantaClara,CA95050
800.879.8585•www.wattstopper.com
02585 r3 05/12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

wattstopper intelliswitch TS-400-24 Installation Instructions Manual

Type
Installation Instructions Manual

Wattstopper IntelliSwitch TS-400-24 is a digital time switch that can be used to automatically turn off lights after a preset amount of time, or to manually override the time-out period. Here are some additional features and possible use cases for this device:

  • Time-out period can be adjusted from 5 minutes to 12 hours.
  • Time-out override allows the user to temporarily change the time-out period without changing the original setting.
  • Visual (flash) and audible (sound) warnings can be enabled to indicate when the time-out period is about to expire.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI