Micro Matic JOETAP JT-CTMG Installation, Use And Maintenance Manual

Type
Installation, Use And Maintenance Manual
NITRO & STILL
BEVERAGE DISPENSER
ON-DEMAND NITROGENATED BEVERAGES
FROM CONCENTRATE
JOETAP
®
BARISTA
SAFETY FIRST!
READ INSTRUCTIONS COMPLETELY
Before getting started please read this
user manual and at all times follow
the important safety instructions.
INSTALLATION, USE & MAINTENANCE GUIDE
JT-CTMG
Pending
Listed by Edison Testing Laboratories.
Conforms to UL & NSF Standards.
v1.0
2 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 3
SAFETY & PROCEDURAL NOTICES .............................................................4
RECEIVING & INSPECTING .......................................................................6
SPECIFICATIONS .......................................................................................6
DIMENSIONS ............................................................................................7
COMPONENTS ..........................................................................................8
LOCATION & INSTALLATION .......................................................................9
MAKING ADJUSTMENTS ..........................................................................15
GENERAL OPERATION .............................................................................20
ROUTINE MAINTENANCE & CLEANING ....................................................21
TROUBLESHOOTING ...............................................................................22
DECOMMISSIONING ................................................................................24
TERMS OF USE. WARRANTY. INDEMNIFICATION. .................................... 26
ROUTINE MAINTENANCE & CLEANING
4 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
SAFETY NOTICES
PROCEDURAL NOTICES
As you work on this equipment, be sure to pay close attention to the safety notices in this
manual and any warning/caution labels on the unit. Disregarding the notices may lead to
serious injury and/or damage to the equipment.
Read and understand ALL applicable OSHA (Occupational Safety and Health Administration)
safety regulations and/or national and local codes before operating this unit.
Throughout this manual, you will see the following types of safety notices:
As you work on this equipment, be sure to read the procedural notices in this manual.
These notices supply helpful information, which may assist you as you work.
Throughout this manual, you will see the following types of procedural notices:
NOTE: Text set off as a “Note:” provides you with simple, but useful, extra information about
the procedure you are performing.
WARNING
Text in a Warning box alerts
you to a potential personal
injury situation. Be sure to
read the Warning statement
before proceeding and work
carefully.
NOTICE
Text in a Notice box provides
you with information that
may help you perform
a procedure more
efciently. Disregarding this
information will not cause
damage or injury, but it may
slow you down as you work.
Indicates information
considered important but
not hazard related.
CAUTION
Text in a Caution box alerts
you to a situation in which
you could damage the
equipment. Be sure to read
the Caution statement
before proceeding and work
carefully.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 5
READ THESE BEFORE PROCEEDING
NOTE: Save these instructions.
NOTE: We reserve the right to make product improvements at any time. Specifications and
design are subject to change without notice.
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
THIS MANUAL MUST BE READ AND UNDERSTOOD BEFORE THE
INSTALLATION AND OPERATION OF THIS DISPENSER
CAUTION
Proper installation, care and
maintenance are essential
for maximum performance
and trouble-free operation
of your equipment. Read and
understand this manual. It
contains valuable care and
maintenance information.
If you encounter problems
not covered by this manual,
do not proceed, contact us.
We will be happy to provide
assistance.
WARNING
PERSONAL INJURY POTENTIAL
Do not operate equipment
that has been misused,
abused, neglected,
damaged, or altered/
modied from that of
original manufactured
specications.
NOTICE
Routine adjustments and
maintenance procedures
outlined in this manual are
not covered by the warranty.
6 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
RECEIVING & INSPECTING
SPECIFICATIONS
Upon receiving your new JoeTap® countertop nitro and still beverage dispenser, check
the package and the unit for any damages that may have occurred during transportation.
Visually inspect the exterior of the package. If damaged, open and inspect the contents with
the carrier. Any damage should be noted and reported on the delivering carrier’s receipt.
In the event that the packaging is not damaged, yet upon opening, there is concealed
damage to the equipment, notify the carrier immediately. Notification should be made
verbally as well as in written form. Request an inspection by the shipping company of the
damaged equipment. Retain all crating material until inspection has been made. Finally,
contact Micro Matic.
UNCRATING:
1. Cut and remove theouter packaging
2. Lift theunit off theskid
3. If unit was laid down during this operation, leave upright for 24 hours before plugging
into power source
WARNING
PERSONAL INJURY POTENTIAL
Do not operate equipment
that has been misused,
abused, neglected,
damaged, or altered/
modied from that of
original manufactured
specications.
Operating Performance
Compressor 1/6 HP
BTU per hour 1135
Condenser HP 1/6
Ambient Temperature Range 45-100° F
Inlet Water Temperature 45-90° F
Ice Bath Capacity 2 gal
Approval
ETL Listed. Conforms to UL 471
& NSF 18. Certied to CSA C22.2
No.120
Air Clearance around unit 6" (153mm)
Plumbing
20-50 psi (138-621 kPa) Machine supplied with 3/8" male barb tting
Requires oor drain
Electrical Requires 2-wire plus ground at 120V, single phase, 60 Hz, 15 amp min. dedicated service
Warranty 1 year parts and labor warranty. All warranty work is handled through JoeTap® certied service agents.
Running Amps 5.0A (0.5A for Nitrogen Generator / 4.5A
for JoeTap® Countertop System)
Voltage 115/60/1
Plug Type NEMA-5-15P
Cord Length 6'
Refrigerant R-134a
Charge 5.5 oz / 160g
Part No. Description Beverage Package Shipping Weight
JT-CTMG JoeTap® Barista, countertop dispenser and nitrogen package Bag in Box (BiB) 169 lbs
77 kg
Pending
Listed by Edison Testing Laboratories.
Conforms to UL & NSF Standards.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 7
NOTE: We have developed this manual as a reference guide for the owner/operator and
installer of this equipment. Please read this manual before installation or operation of
the machine. A qualified service technician must perform installation and start-up of this
equipment. If you cannot or are not qualified to correct the service problem, call your service
provider or distributor. Always have your model and serial number available when you call.
DIMENSIONS
TOP
UP TO 4"
WITH ADJUSTMENT
547.65 [21.56]
578.62 [22.78]
495.66 [19.51]
202.36 [7.97]
606.97 [23.90]
606.97 [23.90]
88.90 [3.50]
547.65 [21.56]
881.65 [34.71]
FRONT SIDE
UP TO 4"
WITH ADJUSTMENT
547.65 [21.56]
578.62 [22.78]
495.66 [19.51]
202.36 [7.97]
606.97 [23.90]
606.97 [23.90]
88.90 [3.50]
547.65 [21.56]
881.65 [34.71]
8 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
COMPONENTS
INCLUDED
(1) Drip tray
(1) Countertop Nitro and Still Beverage Dispenser with built in N2 Generator
(1) 6' section of ½" I.D. x 7/8" O.D. drain line
(2) Stainless stout faucets
(2) Black faucet handles
(1) John Guest: 3/8" stem x 3/8" barb elbow (for water inlet)
NOTE: Serial# and unit name label with electrical specifications/requirements located on
backside of JT-CTMG.
CONTROL PANEL
SYSTEM ON/OFF
INDICATOR LIGHT
GENERATOR ON/OFF
INDICATOR LIGHT
VOLTAGE REGULATOR GAUGE
N2 REGULATOR
ADJUSTMENT SCREW
SCHOLLE BIB
CONNECTOR FITTING
STILL FAUCET WATER
FLOW CONTROL VALVE
NITRO FAUCET
STILL FAUCET
POWER CORD
N2 GENERATOR
GAS RESERVOIR GAUGE
N2 REGULATOR
PRESSURE GAUGE
SHOWN WITH DOOR OPEN AND CHILLER SHROUD REMOVED
WATER INLET PORT
GAS OUT BUTTON
GAS IN BUTTON
GAS OFF BUTTON
PRODUCT PUMP BUTTON
WATER PUMP BUTTON
CHILLER CONTROL
BIB PRODUCT
STORAGE AREA
CHILLER AIR
INLET SHROUD
SERIAL NUMBER/
NAME /CERTIFICATION
LABEL (3" X 5")
ELECTRICAL HAZARD
WARNING LABEL
(3" X 3")
ELECTRICAL HAZARD
WARNING LABEL
(3" X 3")
DATE OF MANUFACTURE
LABEL
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 9
INSTALLATION
NOTE: These instructions are provided to assist the qualified installer. Contact your distributor
or call JoeTap/Micro Matic for information regarding start-up services.
INSTALLATION LOCATION REQUIREMENTS
The JT-CTMG may be island-mounted or installed on a front or rear counter. Locate the
unit so the following requirements are satisfied. This system is for indoor use only and must
NOT be placed in an area where a water jet or similar high-pressure sprayer could be used.
LOCATION & SURFACE
Footprint: 21.56" (548 MM) W x 34.05"(865 MM) H x 17.24"(438 MM) D plus an additional
6" clearance to the left, right and rear of the machine.
Weight: surface must be able to support weight of the dispenser, water/ice bath and BIB
product stored inside (165 LBS fully loaded).
Level surface: The JT-CTMG must be level horizontally from right to left and front to rear.
If surface penetration is necessary, the hole should be at least 2" in diameter and
be closed/sealed once the power cord, drain line and water supply line are in place
and connected.
Avoid placing the dispenser near heat sources such as radiators, ovens, refrigeration
equipment, and direct sunlight.
WATER SUPPLY
Flow rate must be at least .7 GPM
Pressure cannot exceed 50 PSI
Temperature: 45˚ F – 90˚ F
Cannot contain sediment equal to or larger than 5 microns.
Must consist of NSF-61 compliant components.
Must be plumbed with in-line water shutoff valve and backflow prevention device.
A screen of at least 100 mesh (100 strands per 1" [25 MM]) must be installed immediately
upstream of the backflow prevention device.
Water hardness cannot exceed 75 PPM
Cannot be plumbed to demineralized water: a water supply with little or no mineral
content will yield flat beverages.
NOTICE
Failure to follow these
guidelines may affect
warranty coverage.
CAUTION
Cutting the countertop
may decrease its strength.
Counter should be braced
to support the dispenser
countertop weight plus
product storage capacity
and weight of ice/water
bath.
WARNING
Only trained and certied
electrical, plumbing and
refrigeration technicians
should service this unit.
WARNING
All wiring and plumbing must
conform to national and
local codes.
10 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
ELECTRICAL
Must be installed near a properly grounded electrical outlet with proper electrical
requirements fused at proper amperage or circuit connected through an equivalent
HACR circuit breaker with ELCB (GFCI).
Refer to unit name label for required power circuit operating voltage, hertz, and
amp load.
No other equipment should be connected to this circuit.
This appliance must be grounded. In the event of malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock.
This appliance is equipped with a cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinance.
WHEN USING ELECTRIC APPLIANCES BASIC PROCEDURES SHOULD ALWAYS BE
FOLLOWED, INCLUDING THE FOLLOWING:
Read all the instructions before using the appliance.
To reduce the risk of injury, close supervision is necessary when the appliance is
used near children.
Do not contact moving parts.
Only use attachments recommended or sold by the manufacturer.
Do not use outdoors.
For a cord-connected appliance, the following shall be included:
Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Unplug from outlet when not in use and before servicing or cleaning.
Do not operate any appliance with a damaged cord or plug, or after the
appliance malfunctions or is dropped or damaged in any manner. Contact
the nearest authorized service facility for examination, repair, or electrical or
mechanical adjustment.
CHILLER ICE/WATER BATH OVERFLOW DRAIN:
Open gravity drain located within six feet of the machine.
Ensure drain line is always sloping downwards.
Drain hose: 7/8" O.D., 5/8" I.D.
Must conform to national and local codes.
NOTICE
Due to continuous
improvements, this
information is for reference
only. Please refer to the
dispenser serial number
tag to verify electrical
data. Serial tag information
overrides information listed
on this page.
WARNING
Risk of electrical shock.
Connect to a properly
grounded outlet only.
WARNING
Only trained and certied
electrical, plumbing and
refrigeration technicians
should service this unit.
WARNING
JT-CTMG must be electrically
grounded to avoid possible
fatal electrical shock
or serious injury to the
operator. 120V JT-CTMG
power cord is equipped
with a 3-prong plug. If
supply cord is damaged it
must be replaced by the
manufacturer or its service
agent or a similarly qualied
person in order to avoid a
hazard.
WARNING
All wiring and plumbing must
conform to national and
local codes.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 11
REQUIRED TOOLS & MATERIALS
Hand installation pincers for ear clamps (to install ear clamp on water inlet barb connection).
Square head screwdriver (Robertson) & Phillips head screwdriver (to adjust N2 regulator,
gently pry caps, and remove lid from the unit).
Spanner wrench (to tighten still & nitro faucets).
Small funnel (to fill chiller ice/water bath).
Ruler or tape measure (to measure head thickness while calibrating level of
N2 infusion).
Refractometer (to measure brix while calibrating dilution ratio).
Small bucket or pitcher (a container to pour into while calibrating).
Clear cup (preferably one that the establishment intends to use for their Nitrogen Infused
Beverages).
.05" hex key (to adjust pressure switch, if necessary).
Water supply line and proper hardware to connect it to the unit (see detailed water supply
requirements in Installation Location Requirements in section 6).
Electrical outlet (see detailed electrical requirements in Installation Location Requirements
in section 6).
Bag-in-Box product (must be a product with a compatible dilution ratio).
PERISTALTIC PUMP PACKAGE PREPARATION
Locate the Bag-in-Box product and determine proper peristaltic pump gearbox
speed (172 RPM or 282 RPM), tubing inside diameter (1/8", 3/16" or 1/4") and voltage
(12V – 22V).
If a unit is equipped with a peristaltic pump tube diameter and gearbox combination
that cannot properly accommodate flow rate necessary for a given Bag-in-Box prod-
uct, one or both must be replaced to create a suitable tube and gear box combination.
NOTE: See Peristaltic Pump Package Guide (section 6) to determine the proper peristaltic
gearbox RPM, tube diameter and voltage for a given concentrate to water dilution ratio. A
default unit is equipped with a 172 RPM gearbox and 3/16" tube.
NOTE: Always turn OFF and unplug the system from the electrical outlet, turn OFF the in-
line water shutoff valve, and disconnect the system from the water supply before attempting
to service it. Ensure the unit is fully reassembled before reinstalling and reestablishing water
and power connections.
PLACEMENT
Place JT-CTMG in inspected location meeting all Installation Location Requirements
criteria (section 5).
PLUMB DRAIN
Plumb the ice/water bath overflow drain line in accordance with criteria outlined in
Installation Location Requirements (section 5) and in compliance with prevailing national
and local codes.
CAUTION
Cutting the countertop
may decrease its strength.
Counter should be braced
to support the dispenser
countertop weight plus
product storage capacity
and weight of ice/water
bath.
INSTALLATION PROCEDURE
12 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
FILL CHILLER WATER/ICE BATH
• Fill the water/ice bath with 2 gallons of water.
– Water/ice bath should be filled using sight glass tube on the front of the chiller.
NOTE: Sight glass tube accessed by opening dispenser door and removing two Phillips
head screws from white plastic shroud covering the face of the chiller.
Once the water/ice bath is full, water should begin flowing through the ice/water bath
overflow drain line. If not, continue filling slowly until water begins to flow.
INSTALL FAUCETS
Install faucets on the door.
Locate one of the two included stout faucets insert into either of the sockets on the
door. Using a spanner wrench, tighten the collar on the door socket until faucet is
tight and cannot spin freely. The collar must be turned counterclockwise to tighten
the faucet. Repeat this step for the second faucet.
NOTE: Faucet handles should be perpendicular (at 12 o’clock) in relation to the
countertop once tightened.
– Locate the two black tap handles and thread them onto the handles of the faucets.
Ensure that both faucets are closed (handles pointed up and perpendicular to
the counter).
PLUMB WATER SUPPLY LINE
Plumb water line to the unit following all criteria outlined in Installation Location
Requirements (section 5).
Plumb water line with an in-line shutoff, back flow prevention device and water
filter (if the plumber has not already done so), in accordance with criteria outlined
in Installation Location Requirements (section 5) and in conformance with national
and local codes.
– If applicable, install Eltek® Water Block in-line.
Upon turning in-line water shutoff valve to the ON position, observe the unit and all
connection points for leak(s).
If there are any apparent leaks, immediately turn OFF and disconnect the water
supply, turn OFF and unplug the unit, and fix the water leak(s) before proceeding.
NOTE: Ensure the unit is fully reassembled to the manufacturers specifications before
reinstalling and reestablishing water and power connections.
ELECTRICAL CONNECTIONS
Plug the unit into electrical outlet meeting all electrical requirements outlined on unit
name label and in Installation Location Requirements (section 5).
WARNING
All wiring and plumbing must
conform to national and
local codes.
WARNING
JT-CTMG must be electrically
grounded to avoid possible
fatal electrical shock
or serious injury to the
operator. 120V JT-CTMG
power cord is equipped
with a 3-prong plug. If
supply cord is damaged it
must be replaced by the
manufacturer or its service
agent or a similarly qualied
person in order to avoid a
hazard.
WARNING
Risk of electrical shock.
Connect to a properly
grounded outlet only.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 13
STARTUP & GAS LEAK TEST
Open the door and turn ON the two green switches located on the chiller air inlet shroud
and ensure that all of the buttons located on the control panel are turned OFF.
NOTE: Buttons that are on will be illuminated.
Once the N2 Generator has built up pressure and automatically cycled off, observe
for leak(s) by viewing the N2 reservoir pressure gauge.
– If the pressure holds steady, the system is leak free.
If the pressure drops, immediately turn off and unplug the unit, and fix
the gas leak(s) before proceeding with installation.
NITRO & STILL WATER CALIBRATION
• Open the door and set the N2 infusion pressure (N2 regulator) to 40 PSI.
NOTE: see Adjusting Level of N2 Infusion (section 6) to determine how to adjust N2
regulator pressure.
• Open the door and turn ON the water pump button.
• Open the still faucet until water is flowing smoothly at a flow rate of about 1OZ/SEC.
• Open the left faucet (nitro) until water is flowing smoothly.
If water flow is sputtering, slowly turn N2 infusion pressure down until the flow
becomes smooth flow.
NOTE: This unit typically operates with N2 infusion pressure of 40 PSI +/- 2 PSI.
NOTE: Very small adjustments (usually only 1-2 PSI) are required to achieve
smooth flow.
NOTE: See Adjusting Still Water Flow Control Valve (section 6) to determine how
to properly adjust the still faucet water flow rate.
PRIMING THE SYSTEM & INITIAL VOLTAGE/BRIX ADJUSTMENT
• Turn ON the product pump button and turn OFF the water pump button.
Open either faucet for one full second to relieve pressure and then close it. The voltage
regulator (far left gauge) should remain illuminated with a red digital number readout.
Observe and take note of the readout on the voltage regulator. If the voltage regulator is
not currently set to desired voltage, adjust it now.
NOTE: see Adjusting Brix With Voltage (section 6) to determine how to properly adjust the
voltage regulator.
• Turn ON the water pump button.
• Attach Bag-in-Box product to the system.
NOTE: see Changing and Attaching a Bag-in-Box (section 7) to determine how to properly
attach a Bag-in-Box.
Open the nitro and still faucets independently until the stream transitions from water to
finished product.
WARNING
Only trained and certied
electrical, plumbing and
refrigeration technicians
should service this unit.
WARNING
All wiring and plumbing must
conform to national and
local codes.
NOTICE
Do not leave the product
pump button on while the
water pump button is off for
extended periods of time,
as this will cause excessive
wear on the equipment and
could result in pre-mature
product pump maintenance
service
14 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
NOTICE
Do not leave the product
pump button on while the
water pump button is off for
extended periods of time,
as this will cause excessive
wear on the equipment and
could result in pre-mature
product pump maintenance
service
FINE-TUNING BRIX & LEVEL OF N2 INFUSION
Pour a full serving from the nitro faucet and determine if N2 infusion pressure needs to
be adjusted.
If there is too much head/cascading or not enough head/cascading, adjust accordingly.
Recommended head size after settling: ½" +/- ¼".
NOTE: Customer preference may vary.
Continue adjusting, pouring, and measuring until the desired level of N2 infusion
is achieved.
From a full serving with desired level of N2 infusion, take a small sample and
measure brix.
NOTE: See Measuring Brix With a Digital Handheld Refractometer (section 6) to
determine how to properly measure brix with the recommended refractometer.
If brix reading is higher/lower than the desired result, adjust the voltage
regulator accordingly.
NOTE: See Adjusting Brix With Voltage (section 6) to determine how to properly make
adjustments to brix using the voltage regulator.
Pour a full serving from the still faucet.
Take a small sample from the full serving and measure brix.
If brix reading is higher/lower than desired result, adjust the still water flow control
valve accordingly.
NOTE: See Adjusting Still Water Flow Control Valve (section 6) to determine how
to access and properly adjust the still water flow control valve.
Continue to pour full servings, take samples, and measure brix until both faucets have
been calibrated to the desired specification.
NOTE: When calibrating the brix and N2 infusion, the installer must refer exclusively to the
finished product specification agreed upon prior to installation. Verbal requests to change
finished product specification at the time of installation cannot be approved by the installer.
REFRIGERATION CHECK
Observe and take note of the temperature controller readout of the chiller ice/water bath.
Ensure that the ice/water bath is set to 33˚ F
NOTE: Press the set button on the chiller temperature controller to view the ice/water bath
temperature setting. To change the ice/water bath temperature setting, hold the set button
on the temperature controller until the display begins blinking, use the arrow keys to adjust
up and down, and press the set button again to lock/change the setting to the number
displayed on the screen at that time. For more detailed information and instructions.
To ensure the refrigeration is functional, periodically check (every 5-10 MINS) until the
chiller ice/water bath temperature readout has dropped 5˚ F or reaches set temperature.
Reinstall the white plastic chiller air inlet shroud using the two screws
previously removed.
WARNING
Only trained and certied
electrical, plumbing and
refrigeration technicians
should service this unit.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 15
POST-INSTALLATION OVERVIEW
Location
Floor drain, ambient conditions, countertop weight support, air ventilation clearance
Electrical connection
Grounded, dedicated circuit, refer to name label on the back of the system
Water connection
Flow rate, max pressure, in-line shutoff, treatment, temperature
Product pouring to specification from both faucets
Brix, N2 infusion, temperature
Chiller ice/water bath temperature control
Set to desired temperature and proven to refrigerate effectively
Unit was examined for any apparent leaks at time of the installation
N2, water, Bag-in-Box product
Reviewed cleaning and basic operation procedures with staff (if applicable)
NOTE: Only trained and certified technicians should make adjustments to this system.
NOTE: Any time an adjustment is made to brix or level of N2 infusion, 12 OZ of liquid must
be poured from the affected faucet(s) for the adjustment to take full effect. At that point, a
full serving can be poured and tested.
ADJUSTING LEVEL OF N2 INFUSION: GENERAL INFORMATION
N2 Infusion set to specification by making adjustments to on board N2 regulator pressure.
See N2 regulator pressure gauge to determine pressure of N2 being applied to the infuser.
Adjust using a flathead screwdriver: turn clockwise to increase pressure setting or
counterclockwise to decrease pressure setting.
N2 regulator pressure should not fluctuate once set.
NOTE: The N2 regulator adjustment screw features a nut that can be tightened to lock in a
pressure setting. Ensure this nut is loose before attempting to make any adjustments.
MAKING ADJUSTMENTS
16 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
PROCEDURE
Increase Level of N2 infusion (thicker head and more dramatic cascading effect).
– Turn the N2 regulator adjustment screw clockwise.
– Hold the gas in button for a full second.
• Decrease Level of N2 infusion (thinner head and less dramatic cascading effect).
– Turn the N2 regulator adjustment screw counterclockwise.
– Hold the gas out button for a full second.
– If the N2 Generator turns ON, wait for it to build pressure and automatically turn OFF.
– Hold the gas in button for a full second.
NOTE: The N2 regulator adjustment screw is sensitive and may require very small turns/
adjustments to achieve desired N2 infusion specification.
ADJUSTING BRIX WITH VOLTAGE: GENERAL INFORMATION
The voltage regulator controls the voltage that is supplied to the peristaltic pump. Voltage
supplied to the pump determines how fast the pump motor spins (RPM) and how much
liquid can be displaced (flow rate) for a given tubing diameter and gearbox.
The voltage regulator should be set no lower than 12V.
If the proper flow rate cannot be achieved by adjusting voltage within 12-22V, a tubing
change or gearbox change may be necessary.
If flow rate is too high at 12V, a smaller diameter tube and/or lower RPM gearbox must
be used.
If flow rate is too low at 22V, a larger diameter tube and/or higher RPM gearbox must
be used.
NOTE: see Peristaltic Pump Package Guide (section 6) to determine optimal tubing/gearbox
package.
PROCEDURE
Using a flathead screwdriver, gently pry away the clear plastic cover covering the
voltage regulator.
• Turn the water pump button OFF and the product pump button ON.
• Open either of the faucets for a full second and close it.
• Adjust the voltage regulator to the desired voltage.
NOTICE
Do not leave the product
pump button on while the
water pump button is off for
extended periods of time,
as this will cause excessive
wear on the equipment and
could result in pre-mature
product pump maintenance
service
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 17
To adjust the voltage regulator, press
the set button until a digit that needs
adjusted is blinking.
Once a digit that needs adjusted is
blinking, use the +/– buttons on the
regulator to increase or decrease the
blinking digit’s value.
Press the set button to save the updated
digit and voltage.
If more than one digit needs adjusted to
achieve the new voltage setting, adjust
them accordingly.
ADJUSTING STILL WATER FLOW CONTROL VALVE: GENERAL INFORMATION
Still water flow control allows the installer to adjust and set the water flow rate for the still
faucet independently of the nitro faucet water flow rate.
Turning the flow control knob clockwise reduces water flow rate.
• Reducing water flow rate will make the finished product stronger (higher brix).
Turning the flow control knob counterclockwise increases water flow rate.
• Increasing water flow rate will make the finished product weaker (lower brix).
NOTE: Adjustments to still water flow control should not occur until nitro faucet has been
fully calibrated.
NOTE: As a point of reference, the nitro faucet has a constant water flow rate of about 1 OZ/
SEC. To achieve a still drink that is higher in brix and stronger in taste than the equivalent
nitro drink, the flow rate must be adjusted to be less than 1 OZ/SEC. To achieve a still drink
that is lower in brix and weaker in taste than the equivalent nitro drink, the flow rate must be
adjusted to be greater than 1 OZ/SEC.
NOTE: It is helpful to begin with the flow rate knob closed (turned all the way clockwise)
and slowly open (turn counterclockwise) until desired still water flow rate is achieved. To
conserve on Bag-in-Box product, it is recommended that still water flow rate be adjusted
with the product pump turned off. Once flow rate is adjusted to approximately 1 OZ/SEC,
the product pump button can be turned on. At that point, small adjustments and brix
measurements can be made until the still product meets specification.
PROCEDURE
Using a flathead screwdriver, remove the black plastic cap covering the still water flow
control knob.
Adjust still water faucet flow rate by turning the adjustment screw/knob clockwise or
counterclockwise.
18 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
PROCEDURE (CONTINUED)
Test the flow rate adjustment and continue adjusting/testing until the desired water flow
rate and still faucet brix reading are achieved.
Reinstall the black plastic cap that covered the still water flow rate adjustment.
ADJUSTING PRESSURE SWITCH
NOTE: Always check for debris in nose cone of pulsing faucet before determining pressure
switch needs adjusted.
If the flow is pulsing with the faucet wide open, the pressure switch corresponding to that
faucet may need adjusted.
Remove the lid, nitrogen generator chassis & insulation board to access pressure
switch in question.
• Using a .05" Hex Key, turn the adjustment screw clockwise.
If pumps can be heard running after a faucet is closed and fresh pours begin with an
inconsistent flashing of water and then finished product, the pressure switch for that
faucet likely needs adjusted.
Remove the lid, nitrogen generator chassis, & insulation board to access pressure
switch in question.
Using a .05" Hex Key, turn the adjustment screw counterclockwise.
Continue making adjustments and testing until both faucets are consistently pouring
to specification.
NOTE: Pressure switch adjustments more common with less concentrated Bag-in-Box
products and higher N2 infusion settings.
MEASURING BRIX USING A DIGITAL HANDHELD REFRACTOMETER
Ensure the refractometer is calibrated and the prism is clean.
Fill the sample stage with distilled water and press the zero button.
• Pour a full serving.
NOTE: If poured from the nitro faucet, allow it to finish cascading. N2 in the sample can
affect accuracy of brix reading.
Using a pipette or straw, take a sample from the full serving and drip it onto the sample
stage until the product completely covers all of the metal.
Allow the sample stage to conform to the temperature of the prism to achieve
accurate measurements.
NOTE: This can take up to 90 seconds. Taking a measurement before allowing temperature
equalization can result in inaccurate measurements.
855-4JOETAP / (866) 327-4159 / MICROMATIC.COM JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE | 19
• Press the start button to test the sample.
• Record the brix reading.
• Press the start button to test the sample again.
NOTE: If the readings differ by more than .1, press the start button once more and test/
record the reading. Continue until two of the same readings are recorded. This reading
should be interpreted as the current brix for the faucet being tested.
PERISTALTIC PUMP PACKAGE GUIDE
To determine the best peristaltic pump package, follow the instructions below:
• Determine the water to product dilution ratio (concentration) of the Bag-in-Box product.
• Determine the Bag-in-Box product flow rate required.
– This is accomplished by dividing the nitro water flow rate by the dilution ratio.
Example: for a 5:1 ratio, the necessary product flow rate is:
(1775 ML/MIN / 5) = 355 ML/MIN
Choose a pump package that is close to but exceeds the calculated product flow rate.
NOTE: See Peristaltic Pump Flow Rate chart below.
– In the case of a 5:1 ratio product, there are two ideal packages.
• 172 RPM gearbox with a ¼" tube – 600 ML/MIN
• 282 RPM gearbox with a 3/16" tube – 580 ML/MIN
If there is more than one ideal pump package, choose one that requires less time/
labor for setup.
Typically it is easier and less time consuming to change a tube than it is to change
a gearbox.
Once the tube and gearbox package are selected, the supplied voltage to the peristaltic
pump and the still water flow control valve are used to dial in brix of finished product.
PERISTALTIC PUMP FLOW RATE CHART
NOTE: Flow rates advertised in this chart are nominal and may vary.
NOTE: Bag-in-Box product flow rates will likely be less than advertised in this chart.
RPM
1/8" I.D. 3/16" I.D. 1/4" I.D.
ML/MIN ML/MIN ML/MIN ML/MIN ML/MIN ML/MIN
172 150 5.1 350 11.8 600 20.3
282 270 9.1 580 19.6 1000 33.8
20 | JOETAP® BARISTA INSTALLATION, USE & MAINTENANCE GUIDE 855-4JOETAP / (866) 327-4159 / MICROMATIC.COM
GENERAL OPERATION
Under normal circumstances, both green switches on the face of the chiller, the water
pump button, and the product pump button should be ON.
Use only one faucet at a time. If both faucets are opened at the same time, the nitrogen
faucet will starve for water and begin sputtering. If this occurs, close both faucets and
open one at a time until the flow is restored and they are pouring to specification.
When operating the faucets, ensure that you pull the handle all the way down so that
it is at 90 degrees (perpendicular to the flow of coffee from the faucet and parallel to
the countertop).
To achieve product with a rich tight head, tilt the glass slightly and pour the product down
the side of the cup. This method will prevent splattering and turbulence in the cup.
Natural products settle/separate over time. Shake the Bag-in-Box thoroughly prior to
connecting it.
CHANGING AND ATTACHING A BAG-IN-BOX
Acquire Bag-in-Box product and remove white cap from the fitting.
If applicable, disconnect empty Bag-in-Box and dispose of it appropriately.
Rinse connector using a small cup of warm water.
Attach Bag-in-Box connector to fitting on the full Bag-in-Box.
Place the full Bag-in-Box inside with fitting facing downwards.
Open each faucet one at a time until flow transitions from water to finished product.
Fill the sample stage with distilled water and press the zero button.
Pour a full serving.
NOTE: If the faucet has been open for at least 30 seconds, and hasn’t transitioned to finished
product, ensure the product pump button is on (illuminated amber ring) and check the Bag-
in-Box connection to make sure the fitting is attached properly. If the product pump button
is ON, the Bag-in-Box is attached properly, and the system won’t dispense finished product
after 30 more seconds of pouring water, attempt the following Bag-in-Box priming process.
Turn water pump button OFF.
Open either faucet until undiluted Bag-in-Box product is being dispensed.
Turn the water pump button ON.
Open nitro faucet, dispense 6 OZ of liquid, and dispose of it.
Open still faucet, dispense 6 OZ of liquid and dispose of it.
WARNING
ELECTRIC SHOCK HAZARD
Unplug unit before servicing
or cleaning
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Micro Matic JOETAP JT-CTMG Installation, Use And Maintenance Manual

Type
Installation, Use And Maintenance Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI