Eaton 5S 700 is an Uninterruptible Power Supply (UPS) designed for computers and their peripherals, television sets, stereo systems and video recorders. It provides battery backup and surge protection for critical equipment, ensuring that your devices will continue to operate during power outages and voltage fluctuations.

The Eaton 5S 700 has a power capacity of 700 VA / 420 W and provides up to 4.8 A of output current for battery backup outlets. It features 9 battery backup outlets and 8 surge protection outlets, allowing you to connect multiple devices to the UPS.

The UPS is equipped with an automatic battery test function that runs once a week to ensure that the battery is in good condition and can provide reliable backup power when needed. The Eaton 5S 700 also includes an optional audible alarm that can be configured to alert you to power outages and low battery conditions.

Eaton 5S 700 is an Uninterruptible Power Supply (UPS) designed for computers and their peripherals, television sets, stereo systems and video recorders. It provides battery backup and surge protection for critical equipment, ensuring that your devices will continue to operate during power outages and voltage fluctuations.

The Eaton 5S 700 has a power capacity of 700 VA / 420 W and provides up to 4.8 A of output current for battery backup outlets. It features 9 battery backup outlets and 8 surge protection outlets, allowing you to connect multiple devices to the UPS.

The UPS is equipped with an automatic battery test function that runs once a week to ensure that the battery is in good condition and can provide reliable backup power when needed. The Eaton 5S 700 also includes an optional audible alarm that can be configured to alert you to power outages and low battery conditions.

Installation and
user manual
English - Français
Español - Português
EATON 5S
550/700
www.eaton.com
3
614-06820-01
Quick start
C
550 / 700
4
A B
D
6 s
Optional: Audible alarm conguration ON/OFF
Register warranty at: powerquality.eaton.com
4
614-06820-01
Technical characteristics
(*) Warning: Outputcablesshouldnotexceed10m(32.81ft)length.
Eaton 5S 550 700
•UPSpower 550VA/
330W
700VA/
420W
•Nominalinputvoltage 93V-138V
•Inputfrequency 50/60Hz(46-70Hzworkingrange)
•Voltage/frequencyofbatterybackup
outlets
9
inbatterymode
115V+15%-20%(60Hz±1Hz)
•Totaloutputcurrentforalloutlets 10Amax
•Outputcurrentofbatterybackup
outlets
9
4.8Amax 6.14Amax
•Leakagecurrent 0.4mA
•Inputprotection 10Aresettablecircuitbreaker
•Transfertime 5mstypical
•Telephone/Datasurgeprotection Tel,ISDN,ADSL,Ethernet
•Sealedlead-acidbattery 12V,7Ah 12V,9Ah
•Automaticbatterytest Onceaweek
•Averagebatterylife 4yearstypical,dependingontemperatureandnumberofdischargecycles
•Operatingtemperature 0to35°C/32 to 95 °F
•Storagetemperature -25°Cto+55°C/-13 °F to 131 °F
•Operatingrelativehumidity 0to85%
•Operatingelevation 0to2000m/0 to 6562 ft
•Safetystandards UL1778
•Electromagneticcompatibility
standards
FCCPart15ClassB
•Dimensions(mm/inch) 260x87x250/10.24 x 3.43 x 9.84
•Weigth(kg/lb) 5.6/12.3 6.5/14.3
Battery change
• Warning: take care not to inverse the polarity + (red) and - (black) when connecting the battery as this will
destroy the device.
b
c
a
Press and slide
550 / 700
Battery disposal and safety
•Caution.Batteryservicelifeisreducedby50%foreverytendegreesabove25°C(77°F).
•The battery must be replaced exclusively by qualied personnel (risk of shock),withnewbatteryapprovedby
Eatontoensurecorrectoperationofthe UPS.
•Thebatterymustbedisposedofinaccordancewithapplicableregulations.Toremovethebattery,shutdownthe
UPS (button
12
OFF),removethepowercordandproceedasindicatedbelow"Batterychange".
5
614-06820-01
1. Operating conditions
• ThisproductisanUninterruptible PowerSupply(UPS)forcomputersandtheirperipherals,televisionsets,stereo
systemsandvideorecorders...Itmustnotbeusedtosupplyotherelectricalequipment(lighting,heating,household
appliances,etc.).
2. UPS connections
• Connectthe UPS
1
totheAC-powersystemviaawalloutletwithanearthconnector,usingtheinputcord
14

(seegureA).
• Plugcriticalequipment(computer,monitor,modem,etc.)intotheoutlets
9
providingbatterybackuppowerandsurge
protection(seegureC),takingcarenottoexceedtheratedcurrentindicatedinamperes.
• Otherdevices(printer,scanner,fax,etc.)canbeconnecttothesurgeprotectionoutlets
8
(seegureC).Thesurge
protectionoutletsarenotbackedupbybatterypowerintheeventofapoweroutage.
Optional Internet modem / Network connection:
AmodemorEthernetdatalinecanbeprotectedagainstsurgesbyconnectingitviatheUPS.Connecttheexistingdevice
cablebetweenthewalloutletandtheUPS,anduseasimilarcablebetweentheUPSandthedevice,asindicatedin
gureB(cablenotsupplied).
• Optional USB connection:
TheUPSdevicecanbeconnectedtothecomputerusingtheUSBcable
4
supplied(seegureB).
EatonUPSCompanionsoftwareisdownloadablefrompowerquality.eaton.com.
Registerforthewarrantyonpowerquality.eaton.com.
3. Operation
• Battery charge: TheUPSchargesthebatteryassoonasitisconnectedtotheACoutlet,whetherbutton
12
ispressedor
not.Whenusedforthersttime,thebatterywillonlyprovideitsmaximumperformanceafterithasbeenchargedfor8
hours.ItisrecommendedthattheUPSbepermanentlyconnectedtotheACpowersupplytoensurethebestpossible
performance.
• Switching-on the UPS:pressbutton
12
forabout1second.
• Surge protection outlets
8
without battery backup: Equipmentconnectedtotheseoutletsissuppliedassoonasthe
inputACcordispluggedin.Theyarenotaffectedbybutton
12
.
• Battery backup outlets
9
:Equipmentconnectedtotheseoutletsissuppliedassoonasbutton
12
turnsgreen
(seegureD).TheseoutletscanbeturnedoneveniftheUPSisnotconnectedtoACpower(button
12
ashes).
• AC-power disturbance: IfACpowerisdisturbedorfails,theUPScontinuestooperateonbatterypower.Button
12
ashes
green.Innormalmode,theaudiblealarmbeepseverytenseconds,theneverythreesecondswhentheendofbattery
backuptimeisnear.Insilentmode,theaudiblealarmsimplybeepsoncewhentheUPS transferstobatterypower.
• Ifthepoweroutagelastslongerthanthebatterybackuptime,the UPSshutsdownandautomaticallyrestartswhen
powerisrestored.Followingacompletedischarge,afewhoursarerequiredtorechargethebatterybacktofullbackup
time.
• Surge protection:Alloutletsincludesurgeprotection.
• Shutdown of the battery backup outlets
9
: Pressbutton
12
formorethantwoseconds.
12
11
9
8
13
14
8
:Surgeprotectionoutlets.
9
:Batterybackupoutlets.
11
:LEDONindicateaUPSfault.
12
:ON/OFFbuttonforthebatterybackup
outlets.
13
:Protection(circuitbreaker).
14
:ACInputcord.
Troubleshooting (For further information, visit the www.powerquality.eaton.com site or contact post-sales support.)
Problem Diagnostic Solution
1
• Thebatterybackupoutlets
9
arenot
suppliedwithpower.
• Button
12
isnotliteon. • Pressbutton
12
andcheckthatitturns
green.
2 • Theconnecteddevicesarenot
suppliedwhenACpowerfails.
• Thedevicesarenotconnectedtothe
batterybackupoutlets
9
.
• Connectthedevicestothebattery
backupoutlets
9
.
3 • ACpowerisavailable,buttheUPS
operatesonbatterypower.
• Circuitbreaker
13
,locatedattherear
oftheUPS,hasbeentrippedbyan
overloadontheUPSoutput.
• Disconnectexcessequipmentand
resetthecircuitbreaker
13
bypressing
thecorrespondingbutton.
4
• Greenbutton
12
andredLED
11
are
onandaudiblealarmbeepsevery2
seconds.
• TheUPSbatterybackupoutlets
9
areoverloaded.
• Disconnectexcessequipment
connectedtothebatterybackupoutlets
9
.
5
• RedLED
11
isonandtheaudible
alarmbeepscontinuously.
• AfaulthasoccurredontheUPS.The
batterybackupoutlets
9
arenolonger
supplied.
• Callpost-salessupport.
ENGLISH
www.eaton.com
614-06820-01
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Eaton 5S 700 User manual

Category
Surge protectors
Type
User manual
This manual is also suitable for

Eaton 5S 700 is an Uninterruptible Power Supply (UPS) designed for computers and their peripherals, television sets, stereo systems and video recorders. It provides battery backup and surge protection for critical equipment, ensuring that your devices will continue to operate during power outages and voltage fluctuations.

The Eaton 5S 700 has a power capacity of 700 VA / 420 W and provides up to 4.8 A of output current for battery backup outlets. It features 9 battery backup outlets and 8 surge protection outlets, allowing you to connect multiple devices to the UPS.

The UPS is equipped with an automatic battery test function that runs once a week to ensure that the battery is in good condition and can provide reliable backup power when needed. The Eaton 5S 700 also includes an optional audible alarm that can be configured to alert you to power outages and low battery conditions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI