Eaton 5S 550 User manual

Category
Surge protectors
Type
User manual

This manual is also suitable for

Installation and
user manual
English - Français
Español - Português
EATON 5S
550/700
www.eaton.com
3
614-06820-01
Quick start
C
550 / 700
4
A B
D
6 s
Optional: Audible alarm conguration ON/OFF
Register warranty at: powerquality.eaton.com
4
614-06820-01
Technical characteristics
(*) Warning: Outputcablesshouldnotexceed10m(32.81ft)length.
Eaton 5S 550 700
•UPSpower 550VA/
330W
700VA/
420W
•Nominalinputvoltage 93V-138V
•Inputfrequency 50/60Hz(46-70Hzworkingrange)
•Voltage/frequencyofbatterybackup
outlets
9
inbatterymode
115V+15%-20%(60Hz±1Hz)
•Totaloutputcurrentforalloutlets 10Amax
•Outputcurrentofbatterybackup
outlets
9
4.8Amax 6.14Amax
•Leakagecurrent 0.4mA
•Inputprotection 10Aresettablecircuitbreaker
•Transfertime 5mstypical
•Telephone/Datasurgeprotection Tel,ISDN,ADSL,Ethernet
•Sealedlead-acidbattery 12V,7Ah 12V,9Ah
•Automaticbatterytest Onceaweek
•Averagebatterylife 4yearstypical,dependingontemperatureandnumberofdischargecycles
•Operatingtemperature 0to35°C/32 to 95 °F
•Storagetemperature -25°Cto+55°C/-13 °F to 131 °F
•Operatingrelativehumidity 0to85%
•Operatingelevation 0to2000m/0 to 6562 ft
•Safetystandards UL1778
•Electromagneticcompatibility
standards
FCCPart15ClassB
•Dimensions(mm/inch) 260x87x250/10.24 x 3.43 x 9.84
•Weigth(kg/lb) 5.6/12.3 6.5/14.3
Battery change
• Warning: take care not to inverse the polarity + (red) and - (black) when connecting the battery as this will
destroy the device.
b
c
a
Press and slide
550 / 700
Battery disposal and safety
•Caution.Batteryservicelifeisreducedby50%foreverytendegreesabove25°C(77°F).
•The battery must be replaced exclusively by qualied personnel (risk of shock),withnewbatteryapprovedby
Eatontoensurecorrectoperationofthe UPS.
•Thebatterymustbedisposedofinaccordancewithapplicableregulations.Toremovethebattery,shutdownthe
UPS (button
12
OFF),removethepowercordandproceedasindicatedbelow"Batterychange".
5
614-06820-01
1. Operating conditions
• ThisproductisanUninterruptible PowerSupply(UPS)forcomputersandtheirperipherals,televisionsets,stereo
systemsandvideorecorders...Itmustnotbeusedtosupplyotherelectricalequipment(lighting,heating,household
appliances,etc.).
2. UPS connections
• Connectthe UPS
1
totheAC-powersystemviaawalloutletwithanearthconnector,usingtheinputcord
14

(seegureA).
• Plugcriticalequipment(computer,monitor,modem,etc.)intotheoutlets
9
providingbatterybackuppowerandsurge
protection(seegureC),takingcarenottoexceedtheratedcurrentindicatedinamperes.
• Otherdevices(printer,scanner,fax,etc.)canbeconnecttothesurgeprotectionoutlets
8
(seegureC).Thesurge
protectionoutletsarenotbackedupbybatterypowerintheeventofapoweroutage.
Optional Internet modem / Network connection:
AmodemorEthernetdatalinecanbeprotectedagainstsurgesbyconnectingitviatheUPS.Connecttheexistingdevice
cablebetweenthewalloutletandtheUPS,anduseasimilarcablebetweentheUPSandthedevice,asindicatedin
gureB(cablenotsupplied).
• Optional USB connection:
TheUPSdevicecanbeconnectedtothecomputerusingtheUSBcable
4
supplied(seegureB).
EatonUPSCompanionsoftwareisdownloadablefrompowerquality.eaton.com.
Registerforthewarrantyonpowerquality.eaton.com.
3. Operation
• Battery charge: TheUPSchargesthebatteryassoonasitisconnectedtotheACoutlet,whetherbutton
12
ispressedor
not.Whenusedforthersttime,thebatterywillonlyprovideitsmaximumperformanceafterithasbeenchargedfor8
hours.ItisrecommendedthattheUPSbepermanentlyconnectedtotheACpowersupplytoensurethebestpossible
performance.
• Switching-on the UPS:pressbutton
12
forabout1second.
• Surge protection outlets
8
without battery backup: Equipmentconnectedtotheseoutletsissuppliedassoonasthe
inputACcordispluggedin.Theyarenotaffectedbybutton
12
.
• Battery backup outlets
9
:Equipmentconnectedtotheseoutletsissuppliedassoonasbutton
12
turnsgreen
(seegureD).TheseoutletscanbeturnedoneveniftheUPSisnotconnectedtoACpower(button
12
ashes).
• AC-power disturbance: IfACpowerisdisturbedorfails,theUPScontinuestooperateonbatterypower.Button
12
ashes
green.Innormalmode,theaudiblealarmbeepseverytenseconds,theneverythreesecondswhentheendofbattery
backuptimeisnear.Insilentmode,theaudiblealarmsimplybeepsoncewhentheUPS transferstobatterypower.
• Ifthepoweroutagelastslongerthanthebatterybackuptime,the UPSshutsdownandautomaticallyrestartswhen
powerisrestored.Followingacompletedischarge,afewhoursarerequiredtorechargethebatterybacktofullbackup
time.
• Surge protection:Alloutletsincludesurgeprotection.
• Shutdown of the battery backup outlets
9
: Pressbutton
12
formorethantwoseconds.
12
11
9
8
13
14
8
:Surgeprotectionoutlets.
9
:Batterybackupoutlets.
11
:LEDONindicateaUPSfault.
12
:ON/OFFbuttonforthebatterybackup
outlets.
13
:Protection(circuitbreaker).
14
:ACInputcord.
Troubleshooting (For further information, visit the www.powerquality.eaton.com site or contact post-sales support.)
Problem Diagnostic Solution
1
• Thebatterybackupoutlets
9
arenot
suppliedwithpower.
• Button
12
isnotliteon. • Pressbutton
12
andcheckthatitturns
green.
2 • Theconnecteddevicesarenot
suppliedwhenACpowerfails.
• Thedevicesarenotconnectedtothe
batterybackupoutlets
9
.
• Connectthedevicestothebattery
backupoutlets
9
.
3 • ACpowerisavailable,buttheUPS
operatesonbatterypower.
• Circuitbreaker
13
,locatedattherear
oftheUPS,hasbeentrippedbyan
overloadontheUPSoutput.
• Disconnectexcessequipmentand
resetthecircuitbreaker
13
bypressing
thecorrespondingbutton.
4
• Greenbutton
12
andredLED
11
are
onandaudiblealarmbeepsevery2
seconds.
• TheUPSbatterybackupoutlets
9
areoverloaded.
• Disconnectexcessequipment
connectedtothebatterybackupoutlets
9
.
5
• RedLED
11
isonandtheaudible
alarmbeepscontinuously.
• AfaulthasoccurredontheUPS.The
batterybackupoutlets
9
arenolonger
supplied.
• Callpost-salessupport.
ENGLISH
www.eaton.com
614-06820-01
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Eaton 5S 550 User manual

Category
Surge protectors
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI