H3C S5800-60C-PWR Installation guide

Category
Network switches
Type
Installation guide
H3C S5800 Series Ethernet Switches
Installation Manual
New H3C Technologies Co., Ltd.
http://www.h3c.com.hk
Document version: 6W111-20170718
Copyright © 2009-2017, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior
written consent of New H3C Technologies Co., Ltd.
Trademarks
H3C, , H3CS, H3CIE, H3CNE, Aolynk, , H
3
Care, , IRF, NetPilot, Netflow,
SecEngine, SecPath, SecCenter, SecBlade, Comware, ITCMM and HUASAN are trademarks of New
H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage,
use, and disposal of this product must meet the applicable national laws and regulations.
Preface
H3C S5800 Series Ethernet Switches Installation Manual describes the appearance, installation,
power-on, maintenance, and troubleshooting of the H3C S5800 series Ethernet switches.
This preface includes the following topics about the documentation:
• Audience.
• Conventions.
• Obtaining documentation.
• Technical support
• Documentation feedback.
Audience
This documentation is intended for:
• Network planners.
• Field technical support and servicing engineers.
• Network administrators working with the S5800 series.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Descri
p
tion
Boldface Bold text represents commands and keywords that you enter literally as shown.
Italic Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars, from
which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign can
be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Descri
p
tion
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the New User window opens; click OK.
> Multi-level menus are separated by angle brackets. For example, File > Create > Folder.
Symbols
Convention Descri
p
tion
WARNING
An alert that calls attention to important information that if not understood or followed can
result in personal injury.
CAUTION
An alert that calls attention to important information that if not understood or followed can
result in data loss, data corruption, or damage to hardware or software.
IMPORTANT
An alert that calls attention to essential information.
NOTE
An alert that contains additional or supplementary information.
TIP
An alert that provides helpful information.
Network topology icons
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports
Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access controller
engine on a unified wired-WLAN switch.
Represents an access point.
Wireless terminator unit.
Wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
T
T
T
T



Represents a security product, such as a firewall, UTM, multiservice security gateway, or
load balancing device.
Represents a security module, such as a firewall, load balancing, NetStream, SSL VPN,
IPS, or ACG module.
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots, and
other information in the examples differ from what you have on your device.
Obtaining documentation
To access the most up-to-date H3C product documentation, go to the H3C website
at http://www.h3c.com.hk
.
To obtain information about installation, configuration, and maintenance, click
http://www.h3c.com.hk/Technical_Documents
To obtain software version information such as release notes, click
http://www.h3c.com.hk/Software_Download
Technical support
http://www.h3c.com.hk
Documentation feedback
You can email your comments about product documentation to info@h3c.com.
We appreciate your comments.

i
Contents
Product overview ·························································································································································· 1
About the H3C S5800 Switch Series ····························································································································· 1
Switch models and technical specifications ··················································································································· 1
Hardware compatibility matrix ········································································································································ 4
S5800-60C-PWR panel views ········································································································································· 6
Front panel ································································································································································ 6
Rear panel ································································································································································· 7
S5800-56C panel views ·················································································································································· 7
Front panel ································································································································································ 7
Rear panel ································································································································································· 9
S5800-56C-PWR panel views ········································································································································· 9
Front panel ································································································································································ 9
Rear panel ······························································································································································ 10
S5800-54S panel views ················································································································································ 10
Front panel ····························································································································································· 10
Rear panel ······························································································································································ 11
Left side panel ························································································································································ 11
S5800-32C panel views ··············································································································································· 12
Front panel ····························································································································································· 12
Rear panel ······························································································································································ 12
S5800-32C-PWR panel views ······································································································································ 13
Front panel ····························································································································································· 13
Rear panel ······························································································································································ 13
S5800-32F panel views ················································································································································ 14
Front panel ····························································································································································· 14
Rear panel ······························································································································································ 14
Ports ················································································································································································· 15
Console port ·························································································································································· 15
Management Ethernet port ··································································································································· 15
USB port ································································································································································· 15
10/100/1000Base-T Ethernet port ···················································································································· 16
100/1000Base-X SFP port ··································································································································· 16
SFP+ port ································································································································································ 17
LEDs ················································································································································································· 19
System status LED··················································································································································· 19
Power module LED ················································································································································· 20
RPS status LED ························································································································································ 20
Port mode LED ························································································································································ 21
Seven-segment LED ················································································································································ 21
10/100/1000Base-T Ethernet port LED ············································································································· 22
100/1000Base-X SFP port LED ··························································································································· 23
SFP+ port LED ························································································································································ 23
Management Ethernet port LEDs ·························································································································· 24
OAP card status LED ············································································································································· 24
PoE module status LED ·········································································································································· 24
Interface card status LED ······································································································································· 25
Hot swappable power modules···································································································································· 25
Hot swappable fan trays ··············································································································································· 27
Interface cards ································································································································································ 28
ii
OAP cards ······································································································································································ 29
Hot swappable PoE modules ········································································································································ 29
Preparing for installation ··········································································································································· 30
Safety recommendations ··············································································································································· 30
Examining the installation site ······································································································································ 30
Temperature/humidity ·········································································································································· 30
Cleanness ······························································································································································· 31
EMI ·········································································································································································· 31
Laser safety ····························································································································································· 31
Installation tools ······························································································································································ 32
Installing the switch ···················································································································································· 33
Installing the switch in a 19-inch rack ·························································································································· 34
Installation methods ··············································································································································· 34
Mounting bracket and cable management bracket kits ···················································································· 35
Rack mounting rail kit ··········································································································································· 36
Installing the mounting brackets, chassis rails, and grounding cable (for the S5800-54S) ·························· 36
Attaching the mounting brackets to the switch chassis (for all S5800 switches except the S5800-54S) ···· 39
Rack-mounting the S5800-54S switch ················································································································ 40
Rack-mounting an S5800 switch except the S5800-54S ················································································· 43
Mounting the switch on a workbench ·························································································································· 44
Grounding the switch ···················································································································································· 45
Grounding the switch with a grounding strip ····································································································· 45
Grounding the switch in other grounding environment ····················································································· 48
Installing/Removing a fan tray ····································································································································· 49
Installing a fan tray ··············································································································································· 49
Removing a fan tray ·············································································································································· 50
Installing/Removing a power module ·························································································································· 50
Installing/Removing a power module (for the S5800-54S) ············································································· 51
Installing/Removing a power module (for the S5800-60C-PWR and the S5800-32F) ································· 54
Connecting the power cord ·········································································································································· 56
Connecting an AC power cord to the switch ····································································································· 56
Connecting the switch to a –54 VDC output RPS ······························································································ 58
Connecting the switch to a 12 VDC output RPS ································································································ 58
Connecting the PSR150-A/PSR150-A1 ·············································································································· 59
Connecting the PSR150-D/PSR150-D1 to a –48 VDC power source ····························································· 60
Connecting the PSR150-D/PSR150-D1 to a –54 VDC output RPS ·································································· 61
Connecting the PSR300-12A/PSR300-12A1/PSR300-12A2 ·········································································· 61
Connecting the PSR300-12D1/PSR300-12D2 to a –48 VDC power source ················································ 62
Connecting the PSR300-12D1/PSR300-12D2 to a –54 VDC output RPS ······················································ 63
Connecting the PSR750-A ···································································································································· 63
Connecting the PSR750-D to a –54 VDC output RPS ························································································ 64
Connecting the LSVM1AC650/LSVM1AC300 ································································································· 65
Connecting the LSVM1DC650/LSVM1DC300 ································································································· 66
Installing/Removing an interface card························································································································· 66
Installing an interface card ··································································································································· 67
Removing an interface card ································································································································· 68
Installing/Removing an OAP card ······························································································································· 68
Installing an OAP card in the OAP card slot (only for the S5800-60C-PWR) ················································ 68
Removing the card in the OAP card slot (only for the S5800-60C-PWR) ······················································· 69
Installing an OAP card in an expansion interface card slot (for the entire series but the S5800-54S) ······· 70
Removing the OAP card in an expansion interface card slot (for the entire series but the S5800-54S) ···· 70
Installing/Removing a PoE module ······························································································································ 71
Installing a PoE module ········································································································································· 71
iii
Removing the PoE module ···································································································································· 71
Verifying the installation ················································································································································ 72
Powering on the switch for the first time ··················································································································· 73
Setting up the configuration environment ···················································································································· 73
Connecting the console cable ······································································································································ 73
Console cable ························································································································································ 73
Connection procedure ·········································································································································· 73
Setting terminal parameters ·········································································································································· 74
Powering on the switch·················································································································································· 77
Setting up an IRF fabric ············································································································································· 78
IRF fabric setup flowchart ·············································································································································· 78
Planning IRF fabric setup ··············································································································································· 79
Planning IRF fabric size and the installation site ································································································ 79
Identifying the master switch and planning IRF member IDs ············································································ 79
Planning IRF topology and connections ·············································································································· 80
Identifying physical IRF ports on the member switches ····················································································· 81
Planning the cabling scheme ······························································································································· 82
Configuring basic IRF settings ······································································································································· 84
Connecting the physical IRF ports ································································································································ 84
Accessing the IRF fabric to verify the configuration ··································································································· 85
Maintenance and troubleshooting ···························································································································· 86
Password loss ································································································································································· 86
Console login password loss ······························································································································· 86
Boot ROM password loss ····································································································································· 86
Power module failure ····················································································································································· 86
Fixed power module failure ································································································································· 86
Hot swappable power module failure ················································································································ 88
OAP card failure ···························································································································································· 89
Failure of the OAP card in the OAP card slot ···································································································· 89
Failure of the OAP card in an expansion interface card slot ··········································································· 90
Hot swappable PoE module failure ······························································································································ 90
Fan failure ······································································································································································· 91
Fixed fan failure ····················································································································································· 91
Hot swappable fan tray failure ···························································································································· 91
Configuration terminal problems ·································································································································· 91
Index ··········································································································································································· 93
1
Product overview
About the H3C S5800 Switch Series
The H3C S5800 Switch Series is a line of Layer 3 Gigabit Ethernet switching products intended for the
distribution and access layers of enterprise or metropolitan area networks. You can also use this switch
series to offer access to the server farms in a data center.
The H3C S5800 Switch Series offers the following benefits:
• 10-Gigabit uplinks and a wide range of features, including the routing features, IPv4 and IPv6 dual
stack, and H3C cluster management for streamlined network management.
• Innovative Intelligent Resilient Framework (IRF) technology, which can virtualize connected S5800
switches into one virtual switch for higher availability, scalability and resiliency, and manageability.
• Support for the H3C Open Application Architecture (OAA). You can install customized open
application platform (OAP) cards in your S5800 switch to provide services such as firewall,
anti-virus, IPS, and wireless access control.
Switch models and technical specifications
The H3C S5800 Switch Series includes the following models:
• S5800-60C-PWR
• S5800-56C
• S5800-56C-PWR
• S5800-54S
• S5800-32C
• S5800-32C-PWR
• S5800-32F
Table 1 H3C S5800 Switch Series technical specifications
Item
S5800-6
0C-PWR
S5800-56
C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-3
2F
Dimensions
(H × W × D)
86.1 ×
440 ×
465 mm
(3.39 ×
17.32 ×
18.31 in)
43.6 ×
440 × 367
mm (1.72
× 17.32 ×
14.45 in)
43.6 ×
440 ×
427 mm
(1.72 ×
17.32 ×
16.81 in)
43.6 ×
440 ×
660 mm
(1.72 ×
17.32 ×
25.98 in)
43.6 ×
440 ×
367 mm
(1.72 ×
17.32 ×
14.45 in)
43.6 ×
440 ×
427 mm
(1.72 ×
17.32 ×
16.81 in)
43.6 ×
440 ×
427 mm
(1.72 ×
17.32 ×
16.81 in)
Weight
≤ 18 kg
(39.68 lb)
≤ 6.5 kg
(14.33 lb)
≤ 8.5 kg
(18.74 lb)
≤ 12.2 kg
(26.90 lb)
≤ 6.0 kg
(13.23 lb)
≤ 8 kg
(17.64 lb)
≤ 8.5 kg
(18.74 lb)
2
Item
S5800-6
0C-PWR
S5800-56
C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-3
2F
Console ports
1, on the
front
panel
1, covered
by the logo
plate on
the front
panel
1, covered
by the
logo plate
on the
front panel
1, on the
rear panel
1, on the
front panel
1, on the
front panel
1, covered
by the
logo plate
on the
front panel
Management
Ethernet ports
N/A N/A N/A
1, on the
rear panel
N/A N/A
1, on the
rear panel
USB ports (full
speed)
1, on the
front
panel
1, covered
by the logo
plate on
the front
panel
1, covered
by the
logo plate
on the
front panel
1, on the
rear panel
1, on the
front panel
1, on the
front panel
1, covered
by the
logo plate
on the
front panel
10/100/10
00Base-T
Ethernet ports
48, PoE 48 48, PoE 48 24 24, PoE N/A
100/1000B
ase-X SFP
ports
4 N/A N/A N/A N/A N/A 24
SFP+ ports N/A
4 4 6 4 4 4
You can plug an SFP+ transceiver module, SFP transceiver module or SFP+ cable
into an SFP port. An SFP port plugged in with an SFP+ cable can be used to
connect IRF member switches.
Expansion
interface card
slots
2, on the
front
panel
1, on the
rear panel
1, on the
rear panel
N/A
1, on the
rear panel
1, on the
rear panel
1, on the
front panel
OAP card
slots
1 N/A N/A N/A N/A N/A N/A
Fan tray slots
1, hot
swapping
N/A
Fixed fans
are used.
N/A
Fixed fans
are used.
2, hot
swapping
N/A
Fixed fans
are used.
N/A
Fixed fans
are used
1, hot
swapping
PoE module
slots
1, N/A N/A N/A N/A N/A N/A
Power
module slots
2, hot
swapping
N/A N/A
2, hot
swapping
N/A N/A
2, hot
swapping
AC-input
voltage
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz
Max voltage: 90 VAC to 264 VAC @ 47 or 63 Hz
3
Item
S5800-6
0C-PWR
S5800-56
C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-3
2F
DC-input
voltage
Rated
voltage:
• 300
W at
–48
VDC
to
–60
VDC
• 750
W at
–54
VDC
to
–57
VDC
N/A N/A
Rated
voltage:
–40 VDC
to –60
VDC
N/A N/A
Rated
voltage:
–48 VDC
to –60
VDC
RPS-input
voltage
Rated
voltage:
–52 VDC
to –55
VDC
Rated
voltage:
10.8 VDC
to 13.2
VDC
Rated
voltage:
–52 VDC
to –55
VDC
N/A
Rated
voltage:
10.8 VDC
to 13.2
VDC
Rated
voltage:
–52 VDC
to –55
VDC
Rated
voltage:
–52 VDC
to –55
VDC
Minimum
power
consumption
DC: 94 W
AC: 96 W
102 W
DC: 107
W
AC: 131
W
105 W 67 W
DC: 64 W
AC: 85 W
DC: 58 W
AC: 67 W
Maximum
power
consumption
Single DC
output:
1840 W
(1500 W
for PoE
output)
Dual DC
outputs:
1840 W
(1500 W
for PoE
output)
Single AC
output:
714 W
(425 W
for PoE
output)
Dual AC
outputs:
1147 W
(740 W
for PoE
output)
163 W
DC: 973
W (740
W for PoE
output)
AC: 673
W (370
W for PoE
output)
AC: 130
W
DC: 130
W
105 W
DC: 870
W (740
W for PoE
output)
AC: 598
W (370
W for PoE
output)
DC: 136
W
AC: 146
W
4
Item
S5800-6
0C-PWR
S5800-56
C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-3
2F
Operating
temperature
0°C to 45°C (32°F to 113°F)
Operating
humidity
10% to 90%, noncondensing
Hardware compatibility matrix
Interface cards, OAP cards, PoE modules, power modules, and RPSs must be purchased separately.
When you purchase or install these components, check that they are compatible with the switch.
You must separately purchase two fan trays for the S5800-54S switch. All other S5800 switches come
with fixed fans or a fan tray installed.
Table 2 Pluggable component compatibility matrix
Card/module
S5800-6
0C-PWR
S5800-
56C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-32F
Hot swa
pp
able
p
ower module o
p
tions
PSR300-12A Yes No No No No No No
PSR300-12A1 Yes No No No No No No
PSR300-12A2 Yes No No No No No No
PSR300-12D1 Yes No No No No No No
PSR300-12D2 Yes No No No No No No
PSR750-A Yes No No No No No No
PSR750-D Yes No No No No No No
PSR150-A No No No No No No Yes
PSR150-A1 No No No No No No Yes
PSR150-D No No No No No No Yes
PSR150-D1 No No No No No No Yes
LSVM1AC650 No No No Yes No No No
LSVM1DC650 No No No Yes No No No
LSVM1AC300 No No No Yes No No No
LSVM1DC300 No No No Yes No No No
Hot swa
pp
able fan tra
y
o
p
tions
LSW1FAN Yes No No No No No No
LSW1BFAN No No No No No No Yes
LSWM1FANSC No No No Yes No No No
LSWM1FANSCB No No No Yes No No No
5
Card/module
S5800-6
0C-PWR
S5800-
56C
S5800-5
6C-PWR
S5800-5
4S
S5800-3
2C
S5800-3
2C-PWR
S5800-32F
Interface card options
LSW1SP4P0
Yes Yes Yes No Yes Yes Yes
LSW1SP2P0
Yes Yes Yes No Yes Yes Yes
LSW1GP16P0
Yes Yes Yes No Yes Yes Yes
LSW1GT16P
Yes Yes Yes No Yes Yes Yes
LSW1XGT2P0 Yes Yes Yes No Yes Yes Yes
LSW1XGT4P0 Yes Yes Yes No Yes Yes Yes
OAP card options
LSWM1IPS10
Yes No No No No No No
LSWM1FW10
Yes No No No No No No
LSWM1WCM10
Yes No No No No No No
LSWM1WCM20
Yes Yes Yes No Yes Yes Yes
NOTE:
You install the LSWM1WCM20 card in the expansion interface card slot and all other OAP cards in the OAP
card slot.
Hot swappable PoE module options
LSW148POEM
Yes No No No No No No
NOTE:
For more information about these cards and modules, see the following sections:
• "Hot swappable power modules"
• "Hot swappable fan trays"
• "Interface cards"
• "OAP cards"
• "Hot swappable PoE modules"
Table 3 RPS compatibility matrix
RPS
S5800-
60C-PWR
S5800-
56C
S5800-
56C-PWR
S5800-
54S
S5800-
32C
S5800-
32C-PWR
S5800-
32F
RPS1000-A3 Yes No Yes No No Yes Yes
RPS1600-A Yes No Yes No No Yes Yes
RPS800-A No Yes No No Yes No Yes
6
S5800-60C-PWR panel views
Front panel
Figure 1 S5800-60C-PWR front panel
(1) Expansion interface card slot 1 (2) Expansion interface card slot 2
(3) 10/100/1000Base-T Ethernet port LED
(4) Seven-se
g
ment LED
(5) Port mode LED
(6) Console port
(7) USB port (8) System status LED (SYS)
(9) Power module 1 status LED (PWR1)
(10) Power module 2 status LED (PWR2)
(11) OAP card status LED (SLOT3) (12) PoE module status LED (SLOT4)
(13) 100/1000Base-X SFP port LED (14) Port LED mode switching button
(15) 100/1000Base-X SFP port (16) 10/100/1000Base-T auto-sensin
g
Ethernet port
NOTE:
• The S5800-60C-PWR switch comes with the two expansion interface card slots covered by filler panels.
In this figure, two LSW1SP4P0 interface cards are installed in the slots.
• You install the LSWM1WCM20 OAP card in an expansion interface card slot rather than the OAP card
slot.
7
Rear panel
Figure 2 S5800-60C-PWR rear panel
(1) OAP card slot
(2) PoE module slot
(3) Groundin
g
screw (4) Filler modules
(5) Power module slot 1 (6) Power module slot 2
(7) Hot swappable fan tray
NOTE:
• The S5800-60C-PWR switch comes with power module slot 1 empty and power module slot 2 covered
by a filler panel. You can install one or two power modules for the switch as needed. In this figure, two
PSR300-12A AC power modules are installed in the slots.
• This switch also comes with the PoE module slot and the OAP card slot covered by filler panels.
S5800-56C panel views
Front panel
Figure 3 S5800-56C front panel
(1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED
(3) Seven-se
g
ment LED (4) Port mode LED
(5) SFP+ port LED
(6) Lo
g
o plate (A console port and a USB port are under this lo
g
o plate)
(7) System status LED (SYS) (8) RPS status LED (RPS) (9) Interface card status LED (SLOT1)
(10) SFP+ port (11) Port LED mode switchin
g
button
8
To use the console port and USB port, open the logo plate.
Figure 4 Open the S5800-56C logo plate
CAUTION:
To avoid any damage to the logo plate, always follow these instructions on openin
g
and closin
g
the lo
g
o
plate:
• Insert your finger into the notch on the right side of the logo plate to open it. Do not try to open the lo
g
o
plate in any other ways.
• The logo plate is attached to the chassis with a rubber strip on its left. Rotate the logo plate within the
elasticity of the rubber strip. To avoid the rubber strip falling off or being broken, do not pull or rotate the
logo plate with excessive force.
• When closing the logo plate, insert the pin on the left of the logo plate into the fastening hole in the front
panel, rotate the logo plate inward until the tab on the right aligns with the fastening slot on the front
panel, and slightly press the logo plate until the tab clicks into the hole. If the tab is not fully engaged in
the fastening slot, make another try instead of pressing the logo plate with excessive force.
Figure 5 S5800-56C logo plate and ports under the logo plate
(1) Tab of the logo plate (2) Pin of the logo plate
(3) Console port (4) USB port
(5) Fastening slot on the front panel (6) Rubber strip
9
Rear panel
Figure 6 S5800-56C rear panel
(1) Bail latch (2) RPS DC-input power receptacle
(3) Groundin
g
screw (4) Expansion interface card slot
(5) AC-input power receptacle
NOTE:
The S5800-56C switch comes with the expansion interface card slot covered by a filler panel. In this
figure, an LSW1SP4P0 interface card is installed in the slot.
S5800-56C-PWR panel views
Front panel
Figure 7 S5800-56C-PWR front panel
(1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED
(3) Seven-se
g
ment LED (4) Port mode LED
(5) SFP+ port LED
(6) Lo
g
o plate (A console port and a USB port are under this lo
g
o plate)
(7) System status LED (SYS) (8) RPS status LED (RPS)
(9) Interface card status LED (SLOT1)
(10) SFP+ port
(11) Port LED mode switchin
g
button
To use the console port and USB port, open the logo plate, as shown in Figure 4 and Figure 5.
(1) (2)
(3)
(4) (5)
(6)
(7)
(8)
(9)
(11)
(10)
10
Rear panel
Figure 8 S5800-56C-PWR rear panel
(1) RPS DC-input power receptacle (2) Bail latch
(3) Groundin
g
screw (4) Interface card
slot
(5) AC-input power receptacle
NOTE:
The S5800-56C-PWR switch comes with the expansion interface card slot covered by a filler panel. In this
figure, an LSW1SP4P0 interface card is installed in the slot.
S5800-54S panel views
Front panel
Figure 9 S5800-54S front panel
(1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED
(3) SFP+ port (4) Seven-se
g
ment LED
(5) Port LED mode switchin
g
button (6) Port mode LED
(7) System status LED (SYS) (8) SFP+ port LED
11
Rear panel
Figure 10 S5800-54S rear panel
(1) Groundin
g
screw (auxiliary
g
roundin
g
point 2)
(2) Mana
g
ement Ethernet port
(3) Console port (4) Fan tray slot 1
(5) Fan tray slot 2
(6) Power module slot 1
(7) Power module slot 2 (8) LINK LED for the mana
g
ement Ethernet port
(9) ACT LED for the management Ethernet port (10) USB port
NOTE:
• The S5800-54S switch comes with the power module slots empty and the filler modules for the slots as
accessories. You can install one or two power modules for your S5800-54S switch as needed. In this
figure, two LSVM1AC650 AC power modules are installed.
• The S5800-54S switch comes with the fan tray slots empty. You must install two fan trays for the
S5800-54S for adequate heat dissipation, and their models must be the same. In this figure, two
LSWM1FANSC fan trays are installed.
Left side panel
Figure 11 S5800-54S left side panel
(1) Primary
g
roundin
g
point (2) Auxiliary
g
roundin
g
point 1
12
S5800-32C panel views
Front panel
Figure 12 S5800-32C front panel
(1) 10/100/1000Base-T auto-sensing Ethernet port (2) 10/100/1000Base-T Ethernet port LED
(3) SFP+ port LED
(4) Console port
(5) USB port (6) Seven-se
g
ment LED
(7) Port mode LED (8) System status LED (SYS)
(9) RPS status LED (RPS) (10) Interface card status LED (SLOT1)
(11) Port LED mode switchin
g
button
(12) SFP+ port
Rear panel
Figure 13 S5800-32C rear panel
(1) Bail latch (2) RPS DC-input power receptacle
(3) Groundin
g
screw (4) Interface card
slot
(5) AC-input power receptacle
NOTE:
• The S5800-32C switch comes with the expansion interface card slot covered by a filler panel. In this
figure, an LSW1SP4P0 interface card is installed in the slot.
• The switch also comes with the RPS DC-input power receptacle covered by a protective cover.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101

H3C S5800-60C-PWR Installation guide

Category
Network switches
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI