Endres+Hauser EA Dummy plug M20×1.5 Dummy plug NPT½ Mounting Instruction

Type
Mounting Instruction

Endres+Hauser EA Dummy plug M20×1.5 Dummy plug NPT½ is a reliable and versatile device designed for various industrial applications. It excels in replacing defective units with functioning ones of the same type. The dummy plugs are compatible with a wide range of Endress+Hauser products, including Gammapilot, Liquiphant, Micropilot, Prothermo, Cerabar, and Deltabar. They are particularly useful in hazardous locations due to their compliance with Ex documentation (XA).

Endres+Hauser EA Dummy plug M20×1.5 Dummy plug NPT½ is a reliable and versatile device designed for various industrial applications. It excels in replacing defective units with functioning ones of the same type. The dummy plugs are compatible with a wide range of Endress+Hauser products, including Gammapilot, Liquiphant, Micropilot, Prothermo, Cerabar, and Deltabar. They are particularly useful in hazardous locations due to their compliance with Ex documentation (XA).

Products Solutions Services
Installation Instructions
Dummy plug M20×1.5
Dummy plug NPT½
Gammapilot, Liquiphant, Micropilot, Prothermo
Cerabar, Deltabar
EA01319F/00/EN/03.23-00
71618184
2023-05-31
EA01319F
2 Endress+Hauser
1 Intended use
A defective unit can only be replaced with a functioning unit of the same type.
Use only original parts from Endress+Hauser.
Check in the W@M Device Viewer if the spare part is suitable for the existing measuring
device.
In some measuring devices, an overview of spare parts is provided inside the device. If
the spare part set is listed in the overview, it is not necessary to check the Device Viewer.
=
www.endress.com/deviceviewer
Order code Description
Ser. No.: 12345...
=
2 Personnel authorized to carry out repairs
Technical staff must comply with the following requirements for repair, mounting, electrical
installation and commissioning of the measuring devices:
Specialized technical staff must be trained in instrument safety.
They must be familiar with the individual operating conditions of the devices.
In the case of Ex-certified measuring devices, they must also be trained in explosion
protection.
Technical staff carrying out work are responsible for ensuring that the work is carried
out safely and to the required quality standard. They must also guarantee the safety of
the device following repair.
3 Safety instructions
Comply with national regulations governing mounting, electrical installation,
commissioning, maintenance and repair procedures.
For devices intended for use in hazardous locations, please observe the instructions in the
Ex documentation (XA).
In the case of devices in safety-related applications in accordance with IEC 61508 or
IEC 61511: Commission in accordance with Operating Instructions after repair.
Before removing the device: set the process to a safe state and purge the pipe of dangerous
process substances.
EA01319F
Endress+Hauser 3
Risk of injury from hot surfaces! Before commencing work: allow the system and device to
cool down to a touchable temperature.
Observe the Operating Instructions for the device.
Risk of damage to electronic components! Ensure that the working environment is
protected against electrostatic discharge.
Modifications to the device are not permitted.
Observe the instructions for transporting and returning the device outlined in the Operating
Instructions.
Contact Endress+Hauser Service if you have questions: www.addresses.endress.com
4 Tools list
24 mm 10 mm PTFE sealing tape
5 Removal
 1 Installation positions
EA01319F
4 Endress+Hauser
5.1 Dummy plug M20×1.5
1 → 2
24 mm
3.75 Nm
5.2 Dummy plug NPT½
1 → 2
10 mm
6.25 Nm
6 Installation
6.1 General installation instructions
Installation is performed by following the removal procedure in reverse order.
6.2 Special installation instructions
EA01319F
Endress+Hauser 5
3 ×
Only necessary if dummy plug NPT½ not pre-assembled with PTFE sealing tape.
www.addresses.endress.com
*71618184*
71618184
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Endres+Hauser EA Dummy plug M20×1.5 Dummy plug NPT½ Mounting Instruction

Type
Mounting Instruction

Endres+Hauser EA Dummy plug M20×1.5 Dummy plug NPT½ is a reliable and versatile device designed for various industrial applications. It excels in replacing defective units with functioning ones of the same type. The dummy plugs are compatible with a wide range of Endress+Hauser products, including Gammapilot, Liquiphant, Micropilot, Prothermo, Cerabar, and Deltabar. They are particularly useful in hazardous locations due to their compliance with Ex documentation (XA).

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI