Globe GSP30B is a scale and label printing system designed for use in food preparation and service environments. With its user-friendly interface, the GSP30B allows you to quickly and easily create and print labels for a wide range of products, including prepackaged foods, deli items, and produce. The scale features a large, backlit LCD display that makes it easy to read even in low-light conditions, and its durable construction ensures long-lasting performance.

Globe GSP30B is a scale and label printing system designed for use in food preparation and service environments. With its user-friendly interface, the GSP30B allows you to quickly and easily create and print labels for a wide range of products, including prepackaged foods, deli items, and produce. The scale features a large, backlit LCD display that makes it easy to read even in low-light conditions, and its durable construction ensures long-lasting performance.

SLP-V Lite Software User Guide for Globe
Label Printing Scale Model GSP30B
Model GSP30B
This manual contains important safety instructions which
must be strictly followed when using this equipment.
For Service on Your Scale
1. Visit our website at www.globefoodequip.com
2. Or call the Globe Service Department at 937-299-8625 and ask for contact
information for your local service company.
Model #:
Serial #:
- IMPORTANT SAFETY NOTICE -
Visit our website for information on additional products available from Globe.
www.globefoodequip.com
Slicers, Mixers, Countertop Cooking Equipment, Meat Choppers & Scales
ScaleLink Pro 5 Lite
1. Update Date and Time on Scale ..............................................................................................................6
2. Store Settings....................................................................................................................................... 7-8
3. Label Properties ..................................................................................................................................9-11
4. Add a New PLU................................................................................................................................ 12-14
5. Find a PLU .............................................................................................................................................15
6. Edit PLU ........................................................................................................................................... 16-17
7. Delete PLU .............................................................................................................................................18
8. Setting Up Ingredient Labels (E13 only) .......................................................................................... 19-21
9. Preset Keys ............................................................................................................................................22
9.1 DeningKeyboards ....................................................................................................................... 23-24
9.2 Edit Preset Key ....................................................................................................................................25
10. Scale Communication ...................................................................................................................... 26-27
10.1 Scale Network Status .................................................................................................................... 26-27
10.2 Send and Receive ......................................................................................................................... 28-29
10.2.1 Bulk Send and Receive .................................................................................................................30
10.3 Delete Records ....................................................................................................................................31
11. Database Utilities ...................................................................................................................................32
ScaleLink Pro 5 Lite Maintenance Utility
1. Scale Network Monitor ..................................................................................................................... 33-34
2. CongurationLibrary ..............................................................................................................................35
3. Scale Communications .................................................................................................................... 36-37
4. Backup and Restore Scale Data ............................................................................................................38
4.1 Backing up Data from a Scale .............................................................................................................38
4.2 Restoring Data to a Scale.............................................................................................................. 39-40
5. Communications with Scale ...................................................................................................................41
5.1 Send to Scale ................................................................................................................................ 41-42
6. Receive from Scale .......................................................................................................................... 43-44
GLOBE FOOD EQUIPMENT CO.
2153 DRYDEN RD
DAYTON, OH 45439
TOLL FREE: 800-347-5423
PHONE: 937-299-5493
FAX: 937-299-4147
WEBSITE: www.globefoodequip.com
© Globe Food Equipment Company, 2016 1-2016 Ver. 1 Rev. A_2016
Table of Contents
Page 5
ScaleLink Pro 5 Lite
ScaleLink Pro 5 Lite is a software utility used to set up and maintain the data on the GSP30B scale.
ScaleLink Pro 5 Lite includes the following features.
Visual interface for creating and editing the scale’s data.
Store name and address
PLUs
Search function for quickly locating the desired PLU
Keyboard presets
Print scale keyboard templates
Scale data can be sent to and read from the scale via the Ethernet PC connection or a USB device.
The ScaleLink Pro 5 Lite Software User Guide explains how to use the software with the GSP30B scale. The
ScaleLink Pro 5 Lite Software User Guide includes the same features that were setup manually with the GSP30B
Owner’s Manual. For additional features not covered in this ScaleLink Pro 5 Lite Software User Guide, refer to the
“Help” section within the ScaleLink Pro 5 Lite or ScaleLink Pro 5 Lite Maintenance Utility Software. *
When you modify scale data in ScaleLink Pro 5 Lite (such as changing the price for a PLU), the data is passed to
the ScaleLink Pro 5 Lite server where it is updated in the database and added to the queue for sending to each
scale. If a scale is currently connected and turned on, the data will be sent immediately. If a scale is not currently
connected to the network (typically because the power is turned off), the data remains in the scale’s send queue
until the scale comes back on-line, at which time all the queued data is sent. If the server is running continuously,
this ensures that all scales have the most up to date data at all times and changes are not missed because a
scale was turned off at the time.
The initial start up display will open when the ScaleLink Pro 5 Lite software is selected. See Figure 5-1.
Figure 5-1
* The software may show features NOT available in this model.
Page 6
1. Update Date and Time on Scale
Update Date and Time on Scales updates the date and time on all currently on-line scales.
1. Select Update Date and Time on Scale from the Tools drop down menu.
2. A Command Status progress dialog box opens to show whether or not the send operation was successful.
See Figure 6-1
Note: The date and time sent to the scales is the current date and time on the server PC.
Figure 6-1
Page 7
2. Store Settings
Store Settings are used to add, edit and delete store name and address records. In most cases only a single
store name and address is used. Multiple store name and address records are used when packing for more than
one store.
1. Select Store Settings from the Auxiliary Data drop down menu. See Figure 7-1.
2. Select New from the Store Settings tool bar.
Figure 7-1
Page 8
TheoperationandexplanationofeachStoreSettingsdialogbuttonandeldisdescribedbelow:
Operation Explanation
Store No. Speciesthestorenumber.IfyouchangetheStoreNoeld,thedatawillbesavedasa
new store. Any existing store with the same number is overwritten.
Store Name,
Store Address
Enter the store name and address in these areas.
Use the Font combo box and format buttons (bold, italic, etc.) to format the text.
Save New
Left/Right
Arrows
Back
3. KeyinthestorenameandaddressintheNameandAddresselds.SeeFigure8-1.
Note: Whenenteringstorenameandaddress,onlyonelineoftextispermittedforeacheld.
Figure 8-1
Page 9
3. Label Properties
The Label Properties dialog box edits the name, size and background image settings for a label.
1. Select Setup Utility from the menu. See Figure 9-1.
Figure 9-1
2. Select Label Sizes from the ScaleLink Pro 5 Lite Setup Utility window. See Figure 9-2.
Label Sizes
Figure 9-2
Page 10
3. The Label Sizes Settings Dialog box will open. Update Default description text area width 55.0 to
52.0 mm. See Figure 10-1.
Update 55.0 to 52.0
Figure 10-1
1. Select Standard
Label
2. Select Edit
4. Select Standard Label.
5. Select Edit. See Figure 10-2.
Figure 10-2
Page 11
6. The Edit Label Size dialog box will display. See Figure 11-2.
7. Update Product description width from 55.0 to 52.0 mm
Update 55.0 to 52.0
Figure 11-2
8. Select OK to save and close the Edit Label Size dialog box.
9. Select OK to save and close the Label Size Settings dialog box.
10. Close the ScaleLink Pro 5 Lite SetupUtility window.
Page 12
NutritionDeleteNew Edit
Price
Change
Active/
Inactive
4. Add a New PLU
Add/Modify/Delete PLUs is used to create new PLUs, edit PLUs and delete PLUs. This opens a dialog for you
to enter the PLU number. The number defaults to the next unused PLU number. If you wish to use a different
number, enter an unused number, then press Return or click New to open the PLU Edit dialog.
1. Select Add/Modify/Delete PLUs from the Daily Operation drop down menu. See Figure 12-1.
Figure 12-1
Page 13
2. Select the New button. The PLU screen will display. See Figure 13-1.
Note: If you enter the number of an existing PLU, the data for that PLU is displayed. Otherwise, a
newPLUiscreatedandtheinitialvaluesoftheeldsinthelowerhalfofthedialogsaresetto
their default values. The default PLU number can be changed to a different PLU number. A
warningmessagewillopenaskingtoconrmthePLUnumberchange.
Note: ThecursorisinitiallypositionedintheProductDescriptioneld.EnterthePLUdescription.
Next,usethemouseorTABkeytomovethecursortothepriceeldandenterthePLUprice.
Similarly, enter any other values you wish to change
Save New
Character
Map
Back
Figure 13-1
Page 14
PLU
description field
Font settings for
description text
Display next or
previous PLU
Character
Map
Back
Select to display
list of options
Active/
Inactive
}
PLU settings. Use the Tab key
or mouse to select a field. Enter
the value or select from list.
Save New
3. KeyinthePLUdescriptionintheProductDescriptioneld.SeeFigure14-1.
4. SelectorkeyinthePLUSettingsinthePLUSettingseldandthenselecttheSavebutton.
5. Select the Back button to return to PLU list.
Figure 14-1
Page 15
5. Find a PLU
If you know the PLU number
EnterthePLUnumberinthePLUNo.eld.ThespeciedPLUappearsselectedinthePLUlist
.
If you know some or all of the PLU name
ThePLUnameistherstlineofthePLUdescriptionthatappearsonthelabel.Entertheinitialcharactersofthe
PLUnameintheSearcheld.ThePLUlistdisplaysonlythosePLUswithnamesthatstartwiththeenteredtext.
For example, entering “BEEF” displays all PLU names starting with the word “beef”. (The search is not case-
sensitive: entering “beef” is the same as entering “BEEF”.)
You can also use the wildcard characters (‘*’ and ‘?’) to specify a more detailed search condition. For example,
entering “*BEEF” displays all PLU names containing the word “beef”.
Note: The search re-executes automatically each time you type a character. The response may be a
bit slow on older computers. In this case, allow a few seconds for the list to update.
If you do not know the PLU number or name
WhenthecursorisintheSearcheld,thePLUlistonlydisplaysthosePLUsthatmatchthesearchcondition.
MovethecursorbacktothePLUNo.eld(e.g.clickontheeld)toclearthesearchresultsanddisplayallPLUs
in the PLU list.
Next,usethescrollbar,theupanddownarrowkeystoscrollthePLUlistuntilyoundthePLUyouarelooking
for.
Page 16
6. Edit PLU
1. Select Add/Modify/Delete PLUs from the Daily Operations drop down menu.
2. Select a PLU from the PLU list. See Figure 16-1.
Figure 16-1
Edit
Page 17
PLU
description field
Font settings for
description text
Display next or
previous PLU
Character
Map
Back
Select to display
list of options
Active/
Inactive
}
PLU settings. Use the Tab key
or mouse to select a field. Enter
the value or select from list.
Save New
Figure 17-1
3. Select the Edit button or double-click on a PLU to display the PLU Edit window. See Figure 17-1.
4. UpdatetheeldsandselecttheSavebutton.
Note: The New button in the PLU Edit window is used to select the next free PLU number. The de-
fault PLU number can be changed to a different PLU number. A warning message will open
askingtoconrmthePLUnumberchange.PLUwillnotbecreateduntiltheSavebuttonhas
been selected.
5. Select the Back button to return to the PLU screen.
Page 18
Delete
7. Delete PLU
1. Select Add/Modify/Delete PLUs from the Daily Operation drop down menu and select PLU to delete.
2. Select Delete button. A dialog opens asking whether or not to delete the PLU. Screen will
display: This will delete the selected PLU. Do you wish to proceed? See Figure 18-1.
3. Select Yes to delete or No to cancel.
Note: To delete multiple PLUs at once refer to Scale Communication, Delete Records.
Figure 18-1
Page 19
8. Setting Up Ingredient Labels (E13 only)
Setting up ingredient labels requires the use of ScaleLink Pro 5 Lite and ScaleLink Pro 5 Maintenance Utility
Software.
1. Install the ScaleLink Pro 5 Lite and ScaleLink Pro 5 Maintenance Utility Software on your computer following
the guidelines in the “Quick Start Guide for GSP30B Scale”.
2. Connect the scale to PC following the guidelines in the “Quick Start Guide for GSP30B Scale”.
3. Use the “Instruction Manual for Globe Label Printing Scale Model GSP30B, Cassette Set up for Ingredients
(E13) Labels instructions, to format the scale for the ingredient labels.
Starting ScaleLink Pro 5 Lite (second and subsequent times)
When you start ScaleLink Pro 5 Lite, the program will automatically load the Add/Modify/Delete PLUs display
window. See Figure 19-1.
Figure 19-1
Page 20
Figure 20-1
1. Double click on a PLU or select the Edit button to add ingredient information to a PLU (E13 only).
2. Key in the ingredients in the Product Description box and select the Save button (E13 only). Refer to Figure 20-1.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Globe GSP30B Owner's manual

Type
Owner's manual

Globe GSP30B is a scale and label printing system designed for use in food preparation and service environments. With its user-friendly interface, the GSP30B allows you to quickly and easily create and print labels for a wide range of products, including prepackaged foods, deli items, and produce. The scale features a large, backlit LCD display that makes it easy to read even in low-light conditions, and its durable construction ensures long-lasting performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI