Cabletron Systems SmartStack STS16-20FRM Installation and User Manual

Category
Networking
Type
Installation and User Manual

This manual is also suitable for

SmartStack
STS16-20RM/STS16-20FRM
Token Ring Switches
Installation
and
User Guide
i
Notice
Notice
Cabletron Systems reserves the right to make changes in specifications and other
information contained in this document without prior notice. The reader should in all
cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change
without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING
OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED
IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR
SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© October 1999 by:
Cabletron Systems, Inc.
35 Industrial Way
Rochester, NH 03867
All Rights Reserved.
Order Number: 9032957-01
(OC-7052 v. 1.1, 710001810)
SmartStack
is a trademark of Cabletron Systems, Inc.
CompuServe
is a registered trademark of CompuServe, Inc.
i960 microprocessor
is a registered trademark of Intel Corp.
Ethernet
is a trademark of Xerox Corporation.
ii
Notice
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment uses, generates, and can radiate radio
frequency energy and if not installed in accordance with the operator’s manual, may
cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause interference in which case the user will be required to
correct the interference at his own expense.
WARNING:
Changes or modifications made to this device which are not expressly
approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
VCCI Notice
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Equipment (VCCI). If this equipment is used in
a domestic environment, radio disturbance may arise. When such trouble occurs, the user
may be required to take corrective actions.
Industry Canada Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
iii
Notice
Declaration of Conformity
Addendum
Application of Council Directive(s):
89/336/EEC
73/23/EEC
Manufacturers Name:
Cabletron Systems, Inc.
Manufacturers Address:
35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name:
Mr. J. Solari
European Representative Address:
Cabletron Systems Limited
Nexus House,
Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
Conformance to Directive(s)/Product Standards:
EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment:
Networking Equipment, for use
in a Commercial or Light
Industrial Environment.
We the undersigned, hereby declare, under our sole responsibility, that the equipment
packaged with this notice conforms to the above directives.
Manufacturer Legal Representative in Europe
Mr. Ronald Fotino
Mr. J. Solari
Full Name Full Name
Principal Compliance Engineer
Managing Director - E.M.E.A.
Title Title
Rochester, NH, USA
Newbury, Berkshire, England
Location Location
iv
Notice
Table of Contents
1. Introduction 1
Switching Technology . . . . . . . . . . . . . . . . . . . . . . . 2
Switch of Switches. . . . . . . . . . . . . . . . . . . . . . . 2
Switch of Servers . . . . . . . . . . . . . . . . . . . . . . . 3
Switch of Hubs. . . . . . . . . . . . . . . . . . . . . . . . . 3
Switch of Desktops . . . . . . . . . . . . . . . . . . . . . . 3
Switch of Floors and Buildings. . . . . . . . . . . . . . . . . 4
Switch of Routers . . . . . . . . . . . . . . . . . . . . . . . 4
Front Panel Details . . . . . . . . . . . . . . . . . . . . . . . . 5
The MANAGEMENT Port . . . . . . . . . . . . . . . . . . . 5
Token Ring Ports . . . . . . . . . . . . . . . . . . . . . . . 6
Switched Port Analyzer . . . . . . . . . . . . . . . . . . . . 6
SmartStack Interface Modules. . . . . . . . . . . . . . . . . 7
Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . 7
System Request Button . . . . . . . . . . . . . . . . . . . . 7
Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Status and Activity LEDs . . . . . . . . . . . . . . . . . . . 8
Back Panel Details. . . . . . . . . . . . . . . . . . . . . . . . . 10
Features and Specifications . . . . . . . . . . . . . . . . . . . . 11
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 13
2. Switch Overview 17
Multiple Simultaneous Conversations . . . . . . . . . . . . . . . 18
Low Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Address Management . . . . . . . . . . . . . . . . . . . . . . . 19
Multiple Bridging Modes . . . . . . . . . . . . . . . . . . . . . . 20
Source Route Switching (SRS) . . . . . . . . . . . . . . . . 21
Source Route Bridging (SRB) . . . . . . . . . . . . . . . . . 21
Source Route Transparent (SRT) . . . . . . . . . . . . . . . 22
SRT/SRB . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . 23
Three Switching Modes . . . . . . . . . . . . . . . . . . . . . . 24
Cut-Through . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Store and Forward . . . . . . . . . . . . . . . . . . . . . . . 24
Auto (Adaptive Cut-Through) . . . . . . . . . . . . . . . . . 24
Token Ring Port Operation Modes . . . . . . . . . . . . . . . . 25
RI/RO-Like Connection . . . . . . . . . . . . . . . . . . . . . . 26
Transmission Priority Queues . . . . . . . . . . . . . . . . . . . 27
v
Notice
ClearSession Support . . . . . . . . . . . . . . . . . . . . . . 27
CrossLink Connections. . . . . . . . . . . . . . . . . . . . . . 28
Spanning Tree Protocol Support . . . . . . . . . . . . . . . . . 29
VLAN Support . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Dynamic Source Route Recovery . . . . . . . . . . . . . . . . 31
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
SmartStack Manager for Windows . . . . . . . . . . . . . . 35
Telnet Management and VT100 Management (Console) . . 35
IBM LAN Network Manager . . . . . . . . . . . . . . . . . 35
RMON Support . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Built-in Port Counters. . . . . . . . . . . . . . . . . . . . . . . 37
Stackable Architecture . . . . . . . . . . . . . . . . . . . . . . 38
Back-to-Back . . . . . . . . . . . . . . . . . . . . . . . . . 38
Internal Stacker. . . . . . . . . . . . . . . . . . . . . . . . 38
External Stacker . . . . . . . . . . . . . . . . . . . . . . . 38
Optional Redundant Power Supply. . . . . . . . . . . . . . . . 39
3. Preparing for Installation 41
Safety Recommendations . . . . . . . . . . . . . . . . . . . . 41
Safety with Electricity. . . . . . . . . . . . . . . . . . . . . 41
Preventing Electrostatic Discharge Damage . . . . . . . . . 42
Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 43
Environment . . . . . . . . . . . . . . . . . . . . . . . . . 43
Chassis Accessibility . . . . . . . . . . . . . . . . . . . . . 43
Cooling and Airflow. . . . . . . . . . . . . . . . . . . . . . 43
Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . 45
Frame Length Limit. . . . . . . . . . . . . . . . . . . . . . 45
IEEE 802.1D Spanning Tree . . . . . . . . . . . . . . . . . 46
Ring Numbers . . . . . . . . . . . . . . . . . . . . . . . . 47
Connecting to Other Non-IEEE 802.5j Compliant
Fiber Devices. . . . . . . . . . . . . . . . . . . . . . . . . 47
Sample Applications for the STS16-20RM and
the STS16-20FRM . . . . . . . . . . . . . . . . . . . . . . . . 48
Important Management Considerations . . . . . . . . . . . 52
4. Installation 53
Installation Summary . . . . . . . . . . . . . . . . . . . . . . . 53
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . 54
Materials Needed for Installation . . . . . . . . . . . . . . . . . 55
Installing a SmartStack Interface Module . . . . . . . . . . . . 55
Mounting the Chassis . . . . . . . . . . . . . . . . . . . . . . 57
vi
Notice
Rack or Cabinet Mounting . . . . . . . . . . . . . . . . . . . 57
Table-Mounting . . . . . . . . . . . . . . . . . . . . . . . . 58
Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Connecting Devices to the Token Ring Ports . . . . . . . . . 59
Connecting Devices to the Token Ring Ports
Using Building Wiring . . . . . . . . . . . . . . . . . . . . . 60
Checking the Installation. . . . . . . . . . . . . . . . . . . . . . 61
Applying Power . . . . . . . . . . . . . . . . . . . . . . . . . . 62
5. Accessing Switch Management 65
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Connecting the Console . . . . . . . . . . . . . . . . . . . . . . 66
Communication Problems . . . . . . . . . . . . . . . . . . . 68
Diagnostic Screen . . . . . . . . . . . . . . . . . . . . . . . 69
6. Switch Configuration 71
General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . 72
Navigating within the Menus. . . . . . . . . . . . . . . . . . 73
Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . 75
Switch Configuration Screen. . . . . . . . . . . . . . . . . . . . 76
Stack Configuration Screen . . . . . . . . . . . . . . . . . . 79
Module Information Screen . . . . . . . . . . . . . . . . . . 80
VLAN Configuration . . . . . . . . . . . . . . . . . . . . . . . . 82
VLAN Configuration Menu . . . . . . . . . . . . . . . . . . . 83
VLAN Configuration Screen . . . . . . . . . . . . . . . . . . 84
VLAN Parameter Configuration for CRF Screen . . . . . . . 86
VLAN Parameter Configuration for BRF Screen . . . . . . . 88
VLAN Port Configuration Screen . . . . . . . . . . . . . . . 90
IP Configuration Screen . . . . . . . . . . . . . . . . . . . . . . 91
BootP Requests and Parameters . . . . . . . . . . . . . . . 93
SNMP Configuration Menu . . . . . . . . . . . . . . . . . . . . 94
Spanning Tree Protocol . . . . . . . . . . . . . . . . . . . . . . 94
IEEE 802.1D Spanning Tree Protocol (STP) . . . . . . . . . 95
Spanning Tree for BRF Screen . . . . . . . . . . . . . . . . 96
Spanning Tree for CRF Screen . . . . . . . . . . . . . . . . 99
Port Spanning Tree Parameters Screen. . . . . . . . . . . 102
Current Spanning Tree Information Screen . . . . . . . . . 103
Port Configuration Screen . . . . . . . . . . . . . . . . . . . . 104
Switched Port Analyzer Menu . . . . . . . . . . . . . . . . . . 109
CrossLink . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
CrossLink Menu . . . . . . . . . . . . . . . . . . . . . . . 111
CrossLink Configuration Screen . . . . . . . . . . . . . . . 112
vii
Notice
Setting up a CrossLink . . . . . . . . . . . . . . . . . . . . 113
Current CrossLink Information Screen . . . . . . . . . . . . 114
Address Filtering . . . . . . . . . . . . . . . . . . . . . . . . . 115
Filters and Port Security Menu . . . . . . . . . . . . . . . . 116
Configure Filters Screen . . . . . . . . . . . . . . . . . . . 117
Configure Port Security Mode Screen . . . . . . . . . . . . 119
View Port Filters Screen . . . . . . . . . . . . . . . . . . . 120
Protocol Filters Menu. . . . . . . . . . . . . . . . . . . . . 121
Protocol Class Assignment Screen . . . . . . . . . . . . . 122
Port Filtering Attributes Screen. . . . . . . . . . . . . . . . 123
Address Aging . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Address Aging Menu . . . . . . . . . . . . . . . . . . . . 126
Port Address Table Aging Screen . . . . . . . . . . . . . . 126
Master Address Table Aging Screen. . . . . . . . . . . . . 128
Password Menu . . . . . . . . . . . . . . . . . . . . . . . . . 129
Console/Telnet Sessions . . . . . . . . . . . . . . . . . . . . . 131
Console Configuration Menu . . . . . . . . . . . . . . . . . 131
Serial Link Configuration Screen . . . . . . . . . . . . . . . 132
Creating a Console Session Using a Modem . . . . . . . . 133
Stopping the Console Session . . . . . . . . . . . . . . . . 133
Telnet Configuration Screen . . . . . . . . . . . . . . . . . 134
Telnet Sessions Screen . . . . . . . . . . . . . . . . . . . 135
Starting the Telnet Session. . . . . . . . . . . . . . . . . . 136
Stopping the Telnet Session . . . . . . . . . . . . . . . . . 136
Involuntary Termination of the Telnet Session . . . . . . . . 136
Syslog Daemon Screen . . . . . . . . . . . . . . . . . . . . . 138
DSRR Configuration . . . . . . . . . . . . . . . . . . . . . . . 140
DSRR Group Configuration Screen . . . . . . . . . . . . . 142
DSRR Configuration Screen . . . . . . . . . . . . . . . . . 143
Download/Upload Menu . . . . . . . . . . . . . . . . . . . . . 146
Serial Link Download Screen. . . . . . . . . . . . . . . . . 147
TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
TFTP Download/Upload Screen . . . . . . . . . . . . . . . 149
Reset Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
7. Monitoring the Network from the Console
Statistics Menu 153
Statistics Menu . . . . . . . . . . . . . . . . . . . . . . . . . . 154
Switch Statistics Screen . . . . . . . . . . . . . . . . . . . . . 155
Power Supply Information Screen . . . . . . . . . . . . . . . . 157
Port Status Screen . . . . . . . . . . . . . . . . . . . . . . . . 158
Port Statistics Menu . . . . . . . . . . . . . . . . . . . . . . . 160
General Statistics Screen . . . . . . . . . . . . . . . . . . 161
viii
Notice
802.5 Statistics Screen . . . . . . . . . . . . . . . . . . . 165
802.5 State Information Screen . . . . . . . . . . . . . . . 168
802.5 DTR MAC Information Menu . . . . . . . . . . . . . 170
TXI Information Screen . . . . . . . . . . . . . . . . . . . 171
Station-CPort Information Screen . . . . . . . . . . . . . . 173
Address Tables Menu . . . . . . . . . . . . . . . . . . . . . . 175
Master Address Table Screen . . . . . . . . . . . . . . . . 176
Master Route Descriptor Table Screen . . . . . . . . . . . 179
VLAN Address Table Screen . . . . . . . . . . . . . . . . 180
VLAN Route Descriptor Table Screen . . . . . . . . . . . . 181
Locate MAC Address Screen . . . . . . . . . . . . . . . . 182
Current Spanning Tree Information Screen . . . . . . . . . 183
Current Spanning Tree Information for a CRF Screen . . . 186
VLAN Statistics . . . . . . . . . . . . . . . . . . . . . . . . . 189
VLAN Statistics Screen for CRF . . . . . . . . . . . . . . . 189
VLAN Statistics Screen for BRF . . . . . . . . . . . . . . . 190
DSRR Status Screens . . . . . . . . . . . . . . . . . . . . . . 191
DSRR Status Tables Screen . . . . . . . . . . . . . . . . 191
DSRR Neighbor Table Screen. . . . . . . . . . . . . . . . 192
DSRR Acting as Backup Table Screen . . . . . . . . . . . 193
Diagnostic Test Results Screen . . . . . . . . . . . . . . . . . 194
Message Log Information Screen . . . . . . . . . . . . . . . . 195
Display Summary Screen . . . . . . . . . . . . . . . . . . . . 197
8. Monitoring the Network with SNMP 199
SNMP Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
IP Configuration Screen . . . . . . . . . . . . . . . . . . . . . 199
SNMP Configuration . . . . . . . . . . . . . . . . . . . . . . . 200
SNMP Configuration Screen. . . . . . . . . . . . . . . . . 200
Community Strings Screen . . . . . . . . . . . . . . . . . 201
Trap Receivers Screen . . . . . . . . . . . . . . . . . . . 203
List of Supported Traps from a Switch. . . . . . . . . . . . 204
9. Monitoring Port Traffic 209
Switched Port Analyzer Screen . . . . . . . . . . . . . . . . . 211
10. Troubleshooting 213
Obtaining Service . . . . . . . . . . . . . . . . . . . . . . 213
Troubleshooting in a Network . . . . . . . . . . . . . . . . 213
Start of Troubleshooting Process . . . . . . . . . . . . . . 213
Choosing a Troubleshooting Procedure . . . . . . . . . . . 214
ix
Notice
11. Getting in Touch with Technical Support 219
Problem Report Form . . . . . . . . . . . . . . . . . . . . . . 220
Appendix A. Abbreviations 223
Appendix B. Cable and Pin Information 227
Connecting to the Out-of-Band Management Port . . . . . . 227
Out-of-Band Management Port and Cable Pin-Outs . . . . . 228
Twisted-Pair Cable Pin Outs . . . . . . . . . . . . . . . . . 230
Cabling Recommendations. . . . . . . . . . . . . . . . . . 231
Cable Length and Lobe Wiring Rules for
Dedicated-Media LAN Segments . . . . . . . . . . . . . . 233
Cable Length and Lobe Wiring Rules for
Shared-Media LAN Segments . . . . . . . . . . . . . . . . 235
x
Notice
List of Figures
Figure 1. SmartStack STS16-20RM Token Ring Switch . . . . . . . 1
Figure 2. SmartStack STS16-20FRM Token Ring Switch . . . . . . 1
Figure 3. Location of LEDs, Switches, and Connectors
on STS16-20RM . . . . . . . . . . . . . . . . . . . . . . 5
Figure 4. Location of LEDs, Switches, and Connectors
on STS16-20FRM. . . . . . . . . . . . . . . . . . . . . . 5
Figure 5. The Back Panel . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 6. Multiple Conversations Through a STS16-20RM or
STS16-20FRM Switch . . . . . . . . . . . . . . . . . . . 18
Figure 7. Typical Configuration with Switches
Using Multiple Bridging Modes . . . . . . . . . . . . . . . 20
Figure 8. A Switch Configured with Two VLANs . . . . . . . . . . . 30
Figure 9. Example of Dynamic Source Route Recovery, Base
Configuration . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 10. Example of Dynamic Source Route Recovery,
Normal State . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 11. Example of Dynamic Source Route Recovery,
Switch 1 Failed . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 12. Typical LAN Segmentation . . . . . . . . . . . . . . . . . 48
Figure 13. A Simple Application of the Switch . . . . . . . . . . . . . 49
Figure 14. Typical Network without the SmartStack Switches . . . . . 50
Figure 15. Relieving the Overstressed Backbone . . . . . . . . . . . 50
Figure 16. Replacing SRBs with STS16-20RM or STS16-20FRM . . . 51
Figure 17. Star-Wired Topology of Interconnected Switches. . . . . . 52
Figure 18. Removing the SSIM Slot Cover . . . . . . . . . . . . . . . 56
Figure 19. Exposing the Rack Mounting Bracket. . . . . . . . . . . . 57
Figure 20. Mounting the Switch in a Rack or Cabinet . . . . . . . . . 58
Figure 21. Connecting Devices to Token Ring Ports . . . . . . . . . . 60
Figure 22. Connecting using Building Wiring . . . . . . . . . . . . . . 61
Figure 23. The Back Panel of the Switch. . . . . . . . . . . . . . . . 62
Figure 24. View of Console Connection—the MANAGEMENT port . . 66
Figure 25. Switch with Four VLANs . . . . . . . . . . . . . . . . . . 82
Figure 26. Setting up CrossLinks. . . . . . . . . . . . . . . . . . . 109
Figure 27. Primary and Traced DSRR Port . . . . . . . . . . . . . 141
Figure 28. TIA/EIA 232 Null-Modem Cable for the 25-pin Connector 229
Figure 29. TIA/EIA 232 Null-Modem Cable for the 9-pin Connector . 229
Figure 30. Straight-Through Cable . . . . . . . . . . . . . . . . . . 230
Figure 31. Data Connector-to-RJ-45 Straight-Through Cable . . . . 230
xi
Notice
List of Tables
Table 1. Status LEDs and Their Meanings . . . . . . . . . . . . . . 8
Table 2. Stack-link LEDs and Their Meanings . . . . . . . . . . . . 9
Table 3. Port LEDs and Their Meanings . . . . . . . . . . . . . . . 9
Table 4. Back Panel Switches and Connectors. . . . . . . . . . . 10
Table 5. Capacity Specifications . . . . . . . . . . . . . . . . . . 13
Table 6. Performance Specifications . . . . . . . . . . . . . . . . 14
Table 7. Specifications of Physical Characteristics . . . . . . . . . 14
Table 8. Supported MIBs . . . . . . . . . . . . . . . . . . . . . . 34
Table 9. Supported RMON Groups . . . . . . . . . . . . . . . . . 36
Table 10. Console Configuration Settings . . . . . . . . . . . . . . 67
Table 11. Modem Settings . . . . . . . . . . . . . . . . . . . . . . 133
Table 12. Symptom, LED State and Recommended Procedure . . . 214
Table 13. Connecting to the Management Port . . . . . . . . . . . 227
Table 14. Pin-out of the Management Port. . . . . . . . . . . . . . 228
Table 15. Copper Cable Types. . . . . . . . . . . . . . . . . . . . 231
Table 16. Multimode Optical Fiber Cable Types . . . . . . . . . . . 231
Table 17. Lobe Length for 150 Ohm Shielded Media . . . . . . . . 233
Table 18. Lobe Lengths for 100 Ohm Shielded or Unshielded Cable 233
Table 19. Lobe Lengths for 100 or 120 Ohm
Shielded or Unshielded Cable . . . . . . . . . . . . . . . 234
Table 20. Lobe Lengths for Recommended Fiber Cable. . . . . . . 234
Table 21. Alternate Optical Fibers . . . . . . . . . . . . . . . . . . 234
xii
Notice
1
Introduction SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01
1. Introduction
This chapter discusses switching technology and how the SmartStack STS16-
20RM and/or the STS16-20FRM Token Ring Switch can be used to improve
network performance. This chapter also includes a list of features and
specifications for the switch.
Note:
References to SmartStack STS16-20RM are also applicable to SmartStack
STS16-20FRM.
The topics of this chapter are presented under the following titles:
Switching Technology, starting on page 2.
Front Panel Details starting on page 5 and Back Panel Details starting on
page 10.
Back Panel Details, starting on page 10.
The folloiwing figures display a front view of the STS16-20RM and the STS16-
20FRM Token Ring switches.
Figure 1. SmartStack STS16-20RM Token Ring Switch
Figure 2. SmartStack STS16-20FRM Token Ring Switch
2
SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01 Introduction
Switching Technology
Demand for network bandwidth continues to grow, driven by the increasing
number of systems used in network-intensive applications. LAN segmentation has
been the prevalent method for addressing these demands and has been further
popularized by trends toward server centralization. However, the implementation
costs of LAN segmentation, as well as the real performance characteristics of
conventional network components, have served to limit growth of some Token
Ring networks. Alternative technologies for addressing bandwidth demands
present yet other inhibitors, usually relating to costs. Token Ring switching
provides users with an easy, cost-effective technique for addressing these demands.
Token Ring switches, such as the STS16-20RM and the STS16-20FRM, increase
throughput between Token Ring segments by supporting simultaneous, parallel
conversations. Switched connections between Token Ring segments last only for
the duration of the packetnew connections can be made between different
segments for the next packet.
Token Ring switches solve congestion problems caused by high-bandwidth devices
and powerful applications as well as the number of users. Therefore, each of these
devicesservers, for examplecan be assigned its own 16 Mbps segment.
In Token Ring networks, the major bottleneck is typically the throughput to high-
bandwidth devices such as servers, and between routers, bridges, and switches. An
effective solution is full-duplex communication, an option for each segment
connected to a STS16-20RM or a STS16-20FRM port. Normally, Token Ring
operates in half-duplex communication mode, which means stations can either
receive or transmit. With full-duplex technology, two communicating stations can
transmit and receive at the same time. When packets can flow in both directions
simultaneously, effective Token Ring bandwidth doubles from 16 Mbps to 32 Mbps.
The STS16-20RM and the STS16-20FRM can forward Token Ring frames among
multiple, shared or dedicated Token Ring LAN segments. Using a frame
forwarding technique similar to that of a multiport Token Ring transparent bridge,
the switch uses Token Ring MAC addresses to forward Token Ring frames from
any of its ports to any other.
Switch of Switches
The STS16-20RM and the STS16-20FRM can be deployed in a variety of network
configurations, all of which provide a significant increase in network performance.
The series of Cabletron Token Ring products allows users to build network systems
that can transport data efficiently and scale upwards as throughput requirements
increase. The switches deliver high-reliability and media flexibility. These features
combine to allow the switches to be used as a switch of switches which provides
media flexibility in an Token Ring configuration.
3
Introduction SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01
The STS16-20RM and the STS16-20FRM can easily connect with other
SmartStack products to deliver a broad range of network carrying capacity.
Bandwidth is easily scaled to meet all performance requirements.
Switch of Servers
With client/server applications, many client workstations may attempt to access a
single server at the same time. This traffic pattern may create bottlenecks at the
server. To further enhance performance, the STS16-20RM and the STS16-20FRM
can deliver dedicated bandwidth to high-speed file servers. All servers perform
better with dedicated 16 Mbps bandwidth.
Even better performance can be achieved by installing multiple adapters in the
server. By connecting these adapters to the switch, multiple 16 Mbps paths to the
server are created, a solution that is only possible when using a switch.
The switch ties together all Token Ring devices lined to a local wiring center. In
networks, where a significant portion of the traffic moves locally between client
and server, the switch can be very effective.
Switch of Hubs
When network traffic increases beyond the capability of hubs, contention results.
Applications suffer and may even fail. The net effect of such a network
configuration is that all devices share a single 16 Mbps data path, thus reducing
overall network efficiency. The STS16-20RM and STS16-20FRM can be very
effective when used as a switch of hubs.
The switches can alleviate contention through microsegmentation, or reducing the
number of devices in each shared segment. To provide microsegmentation, the
switches divides a single 16 Mbps segment into multiple 16 Mbps segments. As an
example, a workgroup has 16 Mbps of capacity. The 20 ports on the switches
support 10 simultaneous conversations with 20 hubs, thus providing the workgroup
with 160 Mbps bandwidth throughput, which results in a significant gain in
bandwidth.
Switch of Desktops
The STS16-20RM and the STS16-20FRM are a cost-effective means of providing
dedicated bandwidth to individual desktop workstations. In this application, the
switch replaces a hub, providing excellent, hub-like network management
statistics. Total network capacity and throughput increase dramatically for attached
desktop workstations.
4
SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01 Introduction
Switch of Floors and Buildings
For network managers, multistory buildings and campuses can represent a unique
networking challenge. How can a network manager provide an efficient LAN
interconnect for users that are located on several floors of a building or in different
buildings?
Token Ring switching and the SmartStack product family can provide the best
solution. The STS16-20RM and the STS16-20FRM provide enhanced throughput
to local wiring closets that can be connected to a switch located in the data center.
Many networks consist of users located in different buildings of a campus
environment. The switches can be used as a collapsed backbone interconnecting
multiple buildings of a campus. They can provide the connectivity solution and
enhanced throughput that such campus environments require.
Switch of Routers
Router technology has had a significant impact on the design of todays
internetworks. Routers have become the cornerstone of most production networks.
Although well equipped to provide firewall, WAN connectivity, security, and
connection between dissimilar LANs, routers are unable to provide high throughput
between desktop devices and servers. Because of these limitations, routers and
switches perform complimentary functions in the network.
The STS16-20RM and the STS16-20FRM can be used as a front-end to routers to
increase performance in each subnet. Communication between local clients and
servers is enhanced at the workgroup level below the router.
The switches can also be used to back-end routers. In networks were many routers
are interconnected over Token Ring and backbone performance is not acceptable,
the switches provide nonblocking communication between the routers for
enhanced network performance. This provides protocol transparency with
enhanced throughput in each subnet between local servers and desktops, thus
allowing network managers to build logical networks as large as network layer
protocol and broadcast traffic allow.
The Switched Port Analyzer also gives a collapsed backbone network superior
network management and the ability to perform protocol analysis from a single
location. The Switch Port Analyzer provides the latest technology for monitoring
switch-based networks and helps to reduce the cost of managing these networks.
5
Introduction SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01
Front Panel Details
The front panel details of the switches are illustrated in Figure 3 and Figure 4. This
section lists all the connectors, controls, and LEDs of the front panel.
Figure 3. Location of LEDs, Switches, and Connectors
on STS16-20RM
Figure 4. Location of LEDs, Switches, and Connectors
on STS16-20FRM
The MANAGEMENT Port
The 9-pin, male, Out-of-Band Management (OBM) port labelled MANAGEMENT
functions as a DTE port.
This port enables attachment of a terminal, either local or remote, through a modem
connection. The terminal can be used to configure and monitor the switch.
The MANAGEMENT port automatically detects the baud rate of the terminal to
which it is attached.
6
SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01 Introduction
Token Ring Ports
STS16-20RM
Twenty shielded RJ-45 connectors for Token Ring connection.
Support for the IBM Cabling System via 150 ohm, shielded twisted-pair
(150 ohm STP); or 100 or 120 ohm unshielded twisted-pair via Category
3, 4, or 5 cables.
These ports allow half-duplex (HDX) or full-duplex (FDX) connections to
other switches, hubs, or end nodes.
Ports 19 and 20 can attac to a MAU/CAU RI/RO port
STS16-20FRM
Twenty fiber VF-45 connectors for Token Ring connection.
These ports allow half-duplex (HDX) or full-duplex (FDX) connections to
other switches, hubs, or end nodes.
All 20 fiber ports can attach to a MAU/CAU RI/RO port.
On STS16-20FRM, UTP/STP connections are only available by installing
an SSIM-T5-04 Token-Ring SmartStack Interface Module.
The switch will automatically sense what type of Token Ring connection is
being employed on each of its ports, whether it is a connection:
to a shared-media segment via a Token Ring concentrator (Station mode)
to another Token Ring switch
operating at 4 Mbps or at 16 Mbps
to a dedicated-media segment, directly to a Token Ring LAN station
operating in half-duplex or full-duplex mode (Port mode)
The switch will automatically configure (requiring no operator action) each port to
operate at the highest possible level of capability. No special crossover cables are
required for Token Ring stations on dedicated-media segments or for switch-to-
switch connections; the same straight-through cabling is used regardless of the type
of connection. This auto-sense/auto-configure capability of the switch can be
overridden by explicit console management.
Switched Port Analyzer
Any of the Token Ring ports can be configured as an analyzer port. An analyzer
port is used to monitor any of the other ports in the same physical switch. The
activity can then be traced by a Token-Ring network analyzer attached to the
analyzer port.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260

Cabletron Systems SmartStack STS16-20FRM Installation and User Manual

Category
Networking
Type
Installation and User Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI