  • Hello! I am a chat assistant familiar with the user manual for the i3 International Fisheye Camera M79. I've reviewed the document detailing its fisheye lens, PoE power, microSD card support, and various installation options. I'm ready to answer your questions about the camera, its setup, and usage based on this manual.
  • What type of power supply does the camera use?
    What is the maximum storage capacity supported by the microSD card slot?
    What is the default IP address of the camera?
    What is the purpose of the rubber plug included in the package?
Thank you for purchasing i3 International’s M79 Fisheye IP dome camera.
M79 is equipped with a fisheye 1.07mm @ F2.5 lens and digital WDR, and supports
h.265 codec compression.
Note: h.265 codec is supported by SRX-Pro v7 and above only. For backwards
compatibility, change the codec to h.264 in the camera’s web settings > Config >
Image > Video/Audio > Video Compression.
SAFETY
When installing your M79 camera be sure to avoid:
excessive heat, such as direct sunlight or heating appliances
contaminants such as dust and smoke
strong magnetic fields
moisture and humidity
areas with mechanical vibrations
fluorescent lamps or objects that reflect light and unstable light sources
temperatures below -30° C (-22° F) and above 50° C (122° F).
To avoid electrical shock and to preserve the product warranty, DO NOT
disassemble the camera. Refer servicing to qualified personnel only.
POWER SUPPLY
This camera accepts PoE power.
Ensure the supplied voltage meets the power consumption requirements of
this camera (6W) before powering the camera on. Incorrect voltage may cause
irreparable damage to the video camera and will effectively void the camera
warranty.
CLEANING
For maximum optical clarity, the camera dome or lens must remain clean.
Use a soft, dry cloth to remove finger prints or dust from the dome cover.
Use a blower to remove dust from the lens.
Do not use volatile solvents such as alcohol, benzene, or thinners, as they may
damage the surface finishes.
PACKAGE CONTENTS
Ensure that the items received match those listed on the order form and the packing
slip. In addition to this manual and a fully assembled camera, the dome camera
packing box includes:
A. Surface Mount template x1
B. Round Head Screw (Tapping Type) x3
C. Plastic Anchor x3
D. Standard RJ45 Connector x2
E. Rubber plug x1 (block the camera’s
side cable opening in surface installations
where the cable is routed upwards instead
of through the side).
CAMERA PARTS AND DEFINITIONS
BC
D
6MP Infrared Outdoor IP 360-degree Fisheye Camera
M79
User Manual
i3-TRNG-CAMS-M79.indd
Rev. 220127
ACT Download &
Documentation
Scan this QR code or visit ftp.i3international.com to view
and download AnnexxusConfigurationTool v1.9 (ACT).
Contact our Technical Support team at: 1.877.877.7241 or
[email protected] if you have any questions
or concerns regarding camera installation or if you require
software services or support.
E
A
2
1. Magnetic tinted plexiglass cover ring. Lift off using the notch.
2. RJ45 Ethernet PoE Port with waterproof RJ45 connector assembly.
Insert an Ethernet cable into the port for network connection as well as PoE
(Power over Ethernet) power. To maintain water-resistant rating in outdoor
installations, make sure to use the included waterproof RJ45 Connector assembly.
3. Rubber plug (E) for the side cable opening. Install when not routing the cable
through the side opening (E.g. Pendant mount installations)
4. MicroSD Card slot for on-camera video storage (up to 128GB supported, sold
separately).
5. Reset pinhole. Press for 10 seconds to restore camera settings to factory defaults.
6. Grounding threaded screw hole.
7. Mounting holes (x3)
8. Light sensor (do not block or obstruct)
9. Microphone
10. IR LED lights, 65ft/20m (x6)
SURFACE INSTALLATION
Start by preparing the mounting surface. Based on installation location and surface type,
supplied screws and anchors may not be adequate.
For pendant or horizontal wall-mounting, purchase the back box (i3 part numbers: B79)
and use a 3/4” NPT pipe or DB60, respectively. Surface installation can be completed
without a back box.
Note: After installing the camera, your network camera must be accessible from your
local network (LAN).
To complete a surface mount installation:
1. Attach the supplied mounting template to the mounting surface.
2. Drill 3 holes, as marked on the template, insert 3 supplied anchors into the holes.
7
7
1 5/8” (41 mm)
5 1/8” (130 mm)
NOT
IN
USE
Rubber plug (not to scale)
4
5
10
9
3
6
1
10
8
WATERPROOF RJ45 ASSEMBLY
To prevent the corrosion of the RJ45 connector and to maintain the camera
warranty, use the RJ45 waterproof assembly attached to the camera, as shown in
the diagram below.
1
2
3
1. Twist off the RJ45 waterproof
assembly from the RJ45
connector.
2. Feed the CAT5e/6 cable through
the opening in the connector and
crimp it using the standard RJ45
connector provided.
3. Plug the crimped CAT5e/6 cable
into the RJ45 connector on the
camera and twist the waterproof
assembly on to re-attach it.
Figure 3. M79, Parts and Definitions
Figure 1. M79, Accessories
Figure 2. Waterproof RJ45 connector
ADD CAMERA TO SRX-Pro PRO SETUP v7
1. Launch the SRX-Pro Setup from the Desktop or from the SRX-Pro Monitor.
2. In the IE browser, click Continue to this website.
3. Enter your administrator Username and Password and click LOGIN
4. Click on the Add tile.
5. If using SRX-Pro v.7.1, find your M79 camera in the list of
UNASSIGNED CAMERAS. You may need to click REFRESH.
If using SRX-Pro v.7.2 and above, click SEARCH
and wait until your M79 camera is discovered.
6. Select one or more M79 cameras with the same
login credentials and click LOGIN
7. Enter camera’s Username and the Password (configured in the previous
section) and click SAVE
Login status for your device must now show the green check mark .
Note: Devices with “Login failed” status will not be added.
8. Click ADD . Your IP devices have been added to i3 SRX-Pro
Setup and are recording based on Sensor + Motion schedule.
Change resolution and frame rate for each camera in the List section of the
i3 SRX-Pro Setup.
CHANGE CAMERA MODE
M79 Fisheye camera supports two display modes:
Mode 1 (default): Fisheye + Panorama + 3x ePTZ
Mode 2: Fisheye + 4x ePTZ
Switching to Mode 2 (optional):
1. In the camera’s web interface,
click on the Config > Fisheye Parameters option.
2. Click on the Stream Mode drop-down and select “Fisheye or 4 PTZ”
3. Click Save, then click OK in the confirmation window. The camera will reboot.
CHANGE COMPRESSION
M79 is shipped pre-set to h.265 codec, which requires
SRX-Pro v7 and above. If using SRX-Pro v6,
you must change the compression to h.264 first.
1. In the camera’s web interface,
click on the Config > Video/Audio option.
2. Select “IP Channel 1” in Channel ID drop-down menu.
3. Set compression to H264 in Video drop-down menu for all streams and click
Save. Click OK in the confirmation window.
4. Repeat Steps 2-3 for IP Channels 2-5.
MOUNTING OPTIONS
Compatible Mounting Accessories:
B79 - back box for pendant installations
DB60 - goose-neck bracket
DB60CPM - corner/pole mount kit (use with DB60)
4. Wait a few moments for a “Success” message in the Result field.
5. Repeat Steps 1-3 for all detected M79 cameras in the ACT until each
camera has a unique IP address.
6. To confirm your camera’s new IP address, click the IE icon in ACT.
In the IE browser, enter administrative Username (i3admin) and (new) Password
and click LOGIN. The camera web interface will be displayed in the Internet
Explorer window. Download and run the plug-in, if prompted.
If you are unable to see live video on the screen, call i3 International technical
support team for troubleshooting tips: 1.877.877.7241
M79 6MP IP Fisheye Camera
QUICK START GUIDE
3. Drill the conduit hole for the camera cable, if routing the cable upwards, and cover
the cable exit hole with the rubber plug (E). (If routing the cable sideways, through the
cable exit opening, do not drill the conduit hole.)
4. Lift the magnetic cover ring off of the camera using the small notch (Fig. 4).
5. Feed the camera cable through the cut conduit hole or through the side cable opening.
6. Use the tapping screws to secure the camera to the prepared mounting surface. (Fig. 5)
7. Re-attach the magnetic cover ring. (Fig. 5)
Mounting Type Accessories required
Wall mount (e.g. drywall); Surface mount (e.g. drop ceiling) None
Pendant Mount; Electrical Gang Box (round/hex/single) B79
Horizontal Wall Mount B79 + DB60
Pole Mount / Corner Mount B79 + DB60 + DB60CPM
i3 INTERNATIONAL INC. 1.866.840.0004
www.i3international.com
Camera’s default IP address: 192.168.0.16.
Camera’s default Subnet mask address: 255.255.255.0.
Default User name: i3admin
ACTIVATE CAMERA IN ACT
Figure 4. M79, Ring notch and removal Figure 5. M79, Surface installation
Part#: B79 (with RP1)
IMPORTANT: Before adding your camera to SRX-Pro, set the administrative password
and unique camera IP. Your camera will remain inactive and inaccessible until
administrative password is set.
Setting administrative password:
1. Connect your Annexxus M79 camera to the Gigabit switch.
2. Launch i3 Annexxus Configuration Tool (ACT) v.1.9 or higher.
Download and install the latest ACT installation and GiPi package from i3 website, if
needed: https://i3international.com/download
3. In the model drop-down list, select M79.
Security status will say “inactive”.
4. In the Global Camera Settings, click
Set Password
5. In the Set password window, enter the new password in the Password and Confirm
fields. Follow secure password guidelines. Click OK.
The new administrative password will be assigned to the camera and the
Security status will change to “active”.
SET CAMERA IP IN ACT
Note: Your i3 Server must have a valid IP address (not APIPA)
Set your camera’s unique IP address:
1. In Annexxus Configuration Tool, select your M79 camera in the list.
2. Uncheck “Default Account” and enter “i3admin” into Username field and the new
administrative password into the Password field.
3. Enter the new IP address and Subnet Mask and click Update.
Or
/