94056

Saxby Lighting 94056 User manual

  • Hello! I've reviewed the instruction manual for the RULAR SENSOR, specifically models 94056, Rular 78554, Rular 78555, Rular 78556, Rular 78557, Rular 78558, Rular 78559, Rular EM 78560, Rular EM 78561, Rular EM 78562, Rular EM 78563, Rular EM 78564, and Rular EM 78565. It details how to install and set up this compact, motion-sensing device with adjustable detection and hold time settings and detached design, which is intended for indoor use. I'm ready to answer any specific questions you might have about its features, installation, or usage.
  • What is the factory default setting for the detection area and hold time?
    What is the typical installation height for this sensor?
    Where is the sensor suitable for installation?
    What is the microwave frequency of the sensor?
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
2 3 4 5 623456
Ceiling Mounted
1
2
3
4
5
6
7
Mounting
height
Wall Mounted
1 2 3 4 5 9876
1
2
3
4
1
2
3
4
CoveredWell covered
Mounting
height
Input
Output
Detection coverage
Typical installation height 2.5-6m
Technical data
Mechanical structure
Installation hole
N
1. Optional detection range, holdtime.
2. Detached Design.
3. Compact sized
Detection area
Operating voltage
Switching capacity
Stand-by power
Hold time
5.8GHz±75MHz
<0.3mW
Microwave frequency
Microwave power
Mounting height
Detection range
0.5~1.5m/s
Operating temperature
IP rating IP20
Motion detection
-20°C~+55°C
10%/50%/75%/100%
5s/90s/5min/15min
Factory Default Setting: Detection area 100%/ Hold time 5s.
www.saxbylighting.com
Instruction manual
94056
RULAR SENSOR
Saxby Lighting. BH17 7BY
V2 21/04/2020
Thank you for purchasing this light fitting. Please read
the instruction carefully before use to ensure safe and
satisfactory operation of this product. Please retain
these instruction for future reference.
Hold time Detection
area
On/off
control
36.6
4
80.2
65
23
Dimensions (Unit: mm)
Wiring diagram
LED Drive
N
L
N
L
Application
Light on when detect movement, After people leave, Light off after hold on time.
Applications: Dim places such as Basement Parking, Underpass.
Attention
1. Please read the instructions carefully before using this product and keep it well
for all users to read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off
before the installation.
3. We reserve the right to modify any incorrect text, image and necessary technical
parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be
immediately invalid.
1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
Installation precautions
1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or
tree swing.
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false
triggering caused by machine vibration.
Application Environment
1. Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
User Notes
Switch UP
Hold-time
100%
1 2
75%
50%
10%
5s
3 4
90s
5min
15min
The period of light keeping 100% brightness after moving objects leave
the detection area.
Detection area
Hold-time
Detection area
No use
Switch DOWN
In this area,movement will be detected and able to trigger the
sensor.100% detection area is also known as the strong sensitvity.
Settings
Additional instruction manual
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting.
Ensure other persons cannot restore the electrical supply without your knowledge.
Press the terminal
with the tool supplied,
and then take off the
brown / bule wires
94056 Rular Sensor
Accessories:
Rular 78554, 78555, 78556, 78557, 78558 with Sensor
2
2
1
3/4
4 3
5
5
2
01. Locate the 94056 sensor position.
02. Take off the brown / bule wires between the LED driver and the terminal.
03. Take appropriate length of the brown and blue wires connect sensor’s L / N to terminal's L / N.
04. Take appropriate length of brown and blue wires, connect sensor's L' / N' to L / N of LED driver input end.
05. Install the 94056 sensor controller and replace the end cap (sensor detector in the end cap).
94056 Sensor
L
N
L' N'
Driver
LN
L
N
LED
LN
Terminal Block
94056 Sensor
L
N
L' N'
Driver 1
LN
L
N
LED 1
LN
Terminal Block
Driver 2
LN
LED 2
Press the terminal with the tool supplied,
and then take off the brown / blue wires
94056 Rular Sensor
Accessories:
Rular 78559 with Sensor
Connector x 2
(not supplied)
4/5
1
6
4
3
2
2
01. Locate the 94056 sensor position.
02. 1) Remove all wires from terminal L / N;
2) Locate the blue / brown wires connected with No.1 LED driver, then connect the wires to two connectors separately
(don't remove the wires from No.1 LED driver);
3) Locate the blue / brown wires connected with No.2 LED driver, and remove the wires from driver.
03. Take appropriate length of brown and blue wires, connect sensor to terminal's L / N separately.
04. Take appropriate length of the brown and blue wires, connect sensor's L' / N' to two connectors separately.
06. Install the 94056 sensor controller and replace the end cap (sensor detector in the end cap).
05. Take appropriate length of the brown and blue wires, connect NO.2 LED driver's L / N to two connectors separately.
2/3 NO.1
NO.2
NO.1
2
5
Press the terminal with the tool supplied,
and then take off the brown / blue wires
94056 Rular Sensor
Accessories:
Rular EM 78560, 78561, 78562, 78563, 78564 with Sensor
2
2
2
2
5
5
3
3
3/4
4
1
01. Locate the 94056 sensor position.
02. Take off the brown and blue wires between the LED driver and the terminal's 2(Ls) / N.
03. Take appropriate length of brown and blue wires, connect sensor's L / N to terminal's 2(Ls) / N .
04. Take appropriate length of the brown and blue wires, connect sensor's L' / N' to LED driver input end's L / N.
05. Install the 94056 sensor controller and replace the end cap (sensor detector in the end cap). 94056 Sensor
L
N
L' N'
Driver
LN
L
N
LN
Terminal Block
Ls
LN
LED
LED
Driver
LED Emergency Driver
Battery Battery
94056 Sensor
LNL' N'
Driver 2
LN
L
N
LN
Terminal Block
Ls
LN
LED 2
LED
Driver
LED Emergency Driver
Battery Battery
Driver 1
LN
LED 1
94056 Rular Sensor
Accessories:
Rular EM 78565 with Sensor
95191 5W Driver
Connector x 2
(not supplied)
2
01. Locate the 94056 sensor position.
02.
03. Take appropriate length of the brown and blue wires, connect sensor's L / N to terminal's 2(Ls) / N separately.
04. Take appropriate length of the brown and blue wires, connect sensor's L' / N' to two connectors separately.
05. Install the 94056 sensor controller and replace the end cap (sensor detector in the end cap).
NO.2
NO.1
2
Press the terminal with the tool
supplied, and then take off the
wires
NO.2
NO.1
2
2
2
2
1/5
NO.2
NO.1
4
5
3/4
3
1) Locate the brown / blue wires between No. 1 driver and terminal's 2(Ls) / N, remove them from terminal,
and then connect the wires to two connectors separately;
2) Locate the brown / blue wires between No. 2 driver and terminal's 2(Ls) / N, remove them from terminal,
and then connect the wires to two connectors separately.
/