Rmax 637901, 637899, 637900, 637902 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Rmax 637901 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
• ASTMC1289TypeI,Class1and2
• InternationalBuildingCode(IBC)Section2603,FoamPlastic
• ASHRAE90.1
• Miami-DadeCountyProductControlApproved
• CAInsulationDirectory
• TestedperNFPA286(ICC-ESAC12AppendixB)
R-Matte
®
Plus-3
Insulation for the Building Envelope
ROOF
WALL
SPECIALTY
www.rmax.com (800) 527-0890
PRODUCT DESCRIPTION
Rmax R-Matte
®
Plus-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
toreinforcedaluminumfoilfacersoneachside.Whileonesideoftheboardhasareflectivesurface,theothersidehasbeencoatedtohavea
non-reflectivewhitemattesurface.Boardscanbeinstalledwitheitherthesilverorwhitesideout.Foradditionalradiantbarrierproperties,installsilver
sideagainstairspaceifoneexists.
COMPLIANCES
APPLICATIONS
Studwalls;cavitywalls;masonrywalls;exteriorstucco;re-siding;vaultedceilings;atticsandcrawlspaces;limitedroofingapplications
THERMAL PROPERTIES / PRODUCT DATA
“R”meansresistancetoheatflow.ThehighertheR-value,thegreaterthe
insulatingpower.
NominalThickness ThermalR-Value
1
Inches °F•ft
2
•hr/Btu
0.50 3.2
0.75 5.0
1.00 6.0
1.10 6.7
1.25 7.8
1.50 9.6
1.75 11.4
2.00 13.1
2.10 13.9
2.30 15.3
2.50 16.7
2.90 19.6
3.00 20.3
3.50 23.9
3.70 25.3
4.00 27.4
4.50 31.0
1
ThermalvaluesaredeterminedbyusingASTMC518testmethodat75°Fmean
temperatureonmaterialconditionedaccordingtoPIMATechnicalBulletinNo.101.
2
IncludestheASHRAEassigned2.77R-valueofa¾”dead-airspaceagainstthe
reflectivefoilsideofR-Matte
®
Plus-3inatypicalwallassembly.
R-Matte
®
Plus-3 is shipped in bundles that are approximately 48” high and wrapped in plastic for easy
handling.Visitwww.rmax.comforacompletelistofthicknessesandpackaginginformation.
TYPICAL PHYSICAL PROPERTIES
Physical properties shown are based on data obtained under controlled
conditionsandaresubjecttonormalmanufacturingtolerances.
Property TestMethod Results
Density,Overall,Nominal ASTMD1622 2.0pcf
CompressiveStrength ASTMD1621 20psi
1
FlexuralStrength ASTMC203 60psi
FlameSpread,Core
2
ASTME84 75orLess
SmokeDeveloped,Core
2
ASTME84 <450
AirBarrier ASTME2178 <0.02L/(s.m
2
)
WaterVaporTransmission ASTME96 <0.03perm
WaterAbsorption ASTMC209 <0.2%Vol.
DimensionalStability,
LengthandWidth
ASTMD2126 <1%LinearChange
MoldResistance ASTMD3273 10,nodefacement
ServiceTemperatures 250°Fmax
1
Lessthan1”isstandardat16psi.
2
Flamespreadandsmokenumbersareshownforcomparisonpurposesonlyand
arenotintendedtorepresenttheperformanceofR-Matte
®
Plus-3andrelated
componentsunderactualfireconditions.
APPLICATION / INSTALLATION
General–R-Matte
®
Plus-3shallbeinstalledverticallyorhorizontallywithalledgestightlybutted.Verticaljointsmustbebackedbyframingor
structuralsheathing.Tapingthejointsisacceptable,althoughnotrequired.RmaxrecommendsusingapressuresensitivetapesuchasR-SEAL
ConstructionTape,R-SEAL3000,orequivalent.
Securement–Rmaxrecommendsaminimumofeightfastenersper4’x8’board.Additionalfastenersmayberequiredinlocationsexpectedto
experienceadditionalloading(heavywinddrafts/gusts,acceleratedwearandtear,etc.)priortoattachmentofcoveringmaterial(cladding,furring,
thermalbarrier,etc.)orwhennotbeingcovered.Exactnumberoffastenersalsodependsonthetypebeingusedandthecapacity,consultfastener
manufacturer.Fastentowoodframingusingroofingnails,bugleheadscrews,capnails,orstaples.Thefastenersshallbelongenoughtopenetrate
woodframingaminimumof1”.Fastentometalframingusingself-tapingscrewsandplasticwashers.Thefastenersshallbelongenoughtopenetrate
metalframingaminimumoffourthreads.Securetoconcretesurfacesusingplasticmasonryfastenerswithwasheroraqualitygradeconstruction
adhesive.Rodenhousefasteners,soldbyRmax,areagreatoptionforfasteningR-Matte
®
Plus-3towood,steelandconcretesubstrates.Referto
theRmax/RodenhouseFastenerListandInstallationGuideformoredetails.
LIMITATIONS
R-Matte
®
Plus-3isnotrecommended,norwarranted,foruseasacommercialroofinsulationdirectlyundermembranesystems.ConsultRmaxSalesforsuitablecommercialroofinsulationproducts.
R-Matte
®
Plus-3isnotastructuralpanel.Itmustnotbeusedasanailingbaseforanyotherbuildingproducts.Furthermore,studwallsinsulatedwithR-Matte
®
Plus-3mustbeproperlybracedforlateralloads
accordingtotherequirementsoflocalBuildingCodes.
WARNING
InstallationsutilizingR-Matte
®
Plus-3mustbefullyprotectedontheinhabitedsideofthebuildingbyathermalbarriersuchasaminimumof1/2”gypsumwallboard,orequivalent.ConsultlocalBuildingCodesand
insuranceauthoritiesregardingspecialapplicationsordetailsrequiredwhenusingR-Matte
®
Plus-3asanexposedproduct.
Thecodealsohasprovisionsregardingvaporretarders,typeandlocation,basedontheassembly,climatezoneandtheamountofcontinuousinsulation.Itisuptothedesignprofessionaltospecifyanassembly
thatwillperformadequatelyandmeettheserequirements.PertheIBCandIRC,aWRBisrequiredbehindtheexteriorwallveneer.
WARRANTY
SeeRmax“SalesPolicy”forwarrantyconditions.RmaxdoesnotassumeanyresponsibilityorliabilityfortheperformanceofanyproductsotherthanthosemanufacturedbyRmax.NOTE: All Rmax products must
be tarped, placed on skids and kept dry before and throughout construction.
www.rmax.com (800) 527-0890
E-mailusat[email protected]orvisitourwebsitewww.rmax.com
Rmax Sales Ofces and Plant Locations
Central:
13524WelchRoad
Dallas,Texas75244
Phone:972-387-4500
Fax:972-387-4673
TollFree:1-800-527-0890
East:
1649SouthBatesvilleRoad
Greer,SouthCarolina29650
Phone:864-297-1382
Fax:864-234-7548
TollFree:1-800-845-4455
West:
210LyonDrive
Fernley,Nevada89408
Phone:775-575-4849
Fax:775-575-5035
TollFree:1-800-762-9462
2018-04
Proudly Made and
Engineered in the U.S.A.
/