  • Hello! I am an AI chatbot trained to assist you with the Commax IDentry-T45-T Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
USER MANUAL
T45-T
www.commax.com
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and
follow instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
CONTENTS
COMMAX Access Control Solutions
Cautions
Product description
Includid items
Parts and their functions
Dimensions
Fingerprint registration
Verification mode
Functions key
Displays
Menu navigation buttons
Access to the system menu
Enroll
Delete
Amend
Set temp ID
User
Getting Started
Start
Operationg menu
Basic Time, Data, Language, Volume, Background Image
Verification Mode, ID Mask, Use Tamer Alarm
Use Touch Sensor, Calibrate Sensor, Lumidigm Spoof, Restore Factory
Advanced
Setting
AC Setting▶ Define Timezone, User Timezone, Lock Type(NC,NO), Lock Door,Release Time,
Door Open Warning, Instrsion Detection Sensor Mode, Reaccess Count,
Reaccess Limit Time, Wiegand Format, Anti-Passback, Setting Reader Of Outer Fingerprint
Communication▶Device ID, Baud Rate, TCP/IP Settings, Setting Wireless LAN,
Managing Computer IP Address, Communication Password
Schedule▶ Set Tmode, Ring Settings, Auto Door, Auto Funckey, None-Relay Funckey,
Day Light, Holiday, Funckey Alram, CD2 Auto Funckey, Idle Settings
Log Setting▶ Management Log Warning, General Log Warning
3.USB MEMORY
Dounload General Log/ Download All General Log/ Download Management Log/
Download All Management Log/ Download User Info/ Upload User Info/ Upgrade Firmware
4.SYSTEM INFO
Memory▶ User, Fingerprint, ID Card, General Log, Management Log, Number of photo
Device Info▶ Release Date, Serial Number, Manufacturer, Product Name,
Product Type, Engine Version, Firmware Version
Advanced▶ View General Log, View Management Log, View User Info
5.TEST
Test All/ Test Memory/ Test LCD/ Test Sound(AUTO)/ Test Sound(MANUAL)/ Test Sensor/ Test RTC/
Test cast status/ Test Card Reader
CONTENTS
COMMAX Access Control Solutions
Keep out of direct sunlight
and heat radiation sources
Shall not be exposed to dripping
or splashing and no objects filled
with liquids such as vases,
shall be placed on the products.
When cleaning, do not use liquid solvent or
wet cloth. Wipe with soft cloth.
Never disassemble or modify this device in any way.
(KJTECH Co., Ltd is not liable for porblems caused
by unauthorized modification or attempted repair )
Do not install this device
near by TV,monitor or magnetic
interference
If the product fails to operate
normally, contact the authorized
dealer or service senter
Before using this device, read and follow all instructions for safety.
Cautions
COMMAX Access Control Solutions
ARM926E_21bit
NAND Flash 8G + 256RAM
4.3TFT COLOR LCD
5K, 10K, 30K, 50K
Loading function
RS-485, TCP-IP
Loading function
Loading function
Loading function (inner skin way)
Micro SD, USB 2 Slot
500K, 100K
2 EA
VOIP function
125Khz (EM/HID/Prox)
13.56Mhz (Mi fare/I-calss SE/ Felice)
26/34/37/40 bit
4.3inches full touch
143x143x42(mm)
CPU
Memory
display
Fingerprint Capacity
Camera
Communication method
Wi-Fi
Fingerprint forgery prevention
USB
Event Data
Relay
Door phone function
OE(Power of Ethernet)
RF Card
Wie gand input / Output
KEY PAD
Product Size
Product Specification
Confirm the specifications.
COMMAX Access Control Solutions
Bracket
9PIN 6PIN 5PIN 4PIN
(Power, 485 CON)
Cable Screw / Program CD
For Bracket 4ea T3x20mm
For T-45-T 2ea M3x6mm
T-45-T
T-45-T
Includid Items
Wiring harness by the
'wiring manual' to see it.
This system comes with the following comeponents.
LED
Product statu.
CAMER
Face capture
Mike
Door phone function.
Fingerprint Sensor
User registration,
authentication,
On the fingerprint input
Be used.
Card Sensor
Is used for user
authentication.
Color TFT LCD
Displays time,
device status,
user list and UI
for operation
USB & micro SD
USB & micro SD memory devices
For connecting slot.
Connector
Cable for connection to
Connector.
LAN
CON12 CON2
CON1 CON4 CON13
Parts and Their Functions
COMMAX Access Control Solutions
W:143mm
H:143mm
W:143mm
42mm
Front View Bracket
Bracket
Side View
H:143mm
Dimensions
COMMAX Access Control Solutions
You have to register fingerprint in proper way to
enhance recognition rate. Recommended to use
finger which has no damage. Recommended to
register more than two fingerprint in case.
Notes on the fingerprint input
Proper way
Improper Way
Fingerprint Registration
Place the finger on the sensor as seen in below in the proper way. Place the entire area of your finger firmly to the sensor.
COMMAX Access Control Solutions
Card authentication method ID authentication method fingerprint authentication method
CD
CD&FD
ID&CD
ID&CD&FD
ID
ID&FD
OPEN
CLOSE
FP
T45-T supports various type of access mode : Combination of Fingerprint, Card and ID(PIN)
Verification mode can be setup in verification mode (Settings>Basic>Verification Mode)
Vertfication Mode
Setting of operating mode
in accordance with security
level refer to environment
setting > advanced setting >
operating mode
COMMAX Access Control Solutions
1. Press Function Key (F1~F4) only or press numbers after Function Key .
2. Present the card to enter.
CARD Authentication Scheme F1~F4 + 0~9
FD Authentication Scheme F1~F4 + Fingerprint
1. Press Function Key (F1~F4) only or Press numbers after Function Key .
2. Place Finger Print to enter.
ID Authentication Scheme F1~F4 + 0~9
1. Press Function Key (F1~F4) only or Press numbers after Function Key .
2. Input ID used to enter.
Functions Key
Function Key is usually used for Time & Attendance.
The admin is able to setup a certain definition to a function key in the program (F1 = Sing in) The admin is able to find out
the users attendance records.
COMMAX Access Control Solutions
Displays
These displays are primary screens.
COMMAX Access Control Solutions
Function key
Function key
Function key
Function key
Door phone function
Menu Navigation Buttons
COMMAX Access Control Solutions
1. Push menu in the touch screen
2. Input initial secret # 1234 and then push ok
3. Successful entry of system menu
Default condition and admin is not registered.
Access To The System Menu 1
COMMAX Access Control Solutions
1. Push menu in the touchsreen
2. Input manager register # ( ID ) and then push OK
3. Successful entry of system menu
Admin is registered already
Access To The System Menu 2
Only when admin is registered. Refer to “Admin Registration part” for admin registration.
When admin ID is incorrect, access to the system menu is denied. When admin ID is not registered anyone can be access to system menu.
So it is highly recommended to register admin More than one. Unless stated otherwise instructions in this manual stars from system menu.
COMMAX Access Control Solutions
www.commax.com
USER
COMMAX Access Control Solutions
1. Touch right down menu icon in the desktop
2. Input manager password ( initial secret # 1234 )
3. Click user icon
4. Click registration icon
5. Designation of number, input name & setting rights
6. Rights can be selected among user and manager
7. Push next button, enroll fingerprint, card photo
8. When light come to sensor, input 3 times of fingerprint.
9. After select card enroll, touch card automatically
read card value
10. After select photo enroll, shooting
11. After finishing all enrollment, push complete
button and return.
COMMAX Access Control Solutions
In the case registered manager, initial P/W vanish,
so preparing the absence or leaving of manager, we recommend registering one more manager.
In the middle of registration process, first fingerprint or second fingerprint or card, one or two doing, other process will be omit.
User>Registration
1. After entry of system manu > user and manager > delete
2. Delete card or fingerprint of registered management.
3. Return to initial screen
※ After delete all manager, automatically change initial # 1234
User>Delete
Same as registration process, it is able to delete 1st fingerprint, 2nd fingerprint and card in each,
If wish to delete all 3data, select ‘Delete All’ and corresponding ID is deleted
COMMAX Access Control Solutions
1. After entry system menu > user > enroll
2. After input ID of needing of amend #, and push OK.
3. After select fingerprint or card then amend
4. Return to initial screen
COMMAX Access Control Solutions
User>Amend
Function of amending user, it is possible to change manger to user or user to manager,
also amend registered fingerprint and card data.
1. After entry system menu > setting temporarily ID > input user info.
2. Input temporarily # ( ID ) ( it is possible 8 site ).
3. Input time of access by temporarily ID
4. Setting temporarily ID
5. Return to initial screen
COMMAX Access Control Solutions
User>Set Temp ID
Temp ID cannot be an Admin and not use fingerprint Admin can determine access times of Temp ID
(min.1~max.9) Access times are expired, Admin can revert it.
emp ID leaves log data Pre-registered ID is not used as a temp ID.
/