ADTRAN Total Access 1500 Installation and Maintenance

  • Hello! I am an AI chatbot trained to assist you with the ADTRAN Total Access 1500 Installation and Maintenance. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
installation guide
Total Access 1500
Total Reach DDS-DP
Installation and Maintenance Guide
Document Number: 61180105L1-5C
CLEI: VAL2JG0A_ _
July 2010
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
ii 61180105L1-5C
Front Matter
Trademarks
Brandnamesandproductnamesincludedinthisdocumentaretrademarks,registeredtrade
marks,ortradenamesoftheirrespectiveholders.
To the Holder of this Document
Thecontentsofthisdocumentarecurrentasofthedateofpublication.ADTRAN
®
reserves
therighttochangethecontentswithoutpriornotice.
InnoeventwillADTRANbeliableforanyspecial,incidental,orconsequentialdamagesor
forcommerciallossesevenifADTRANhasbeenadvisedthereofasaresultofissueofthis
document.
About this Document
ThisdocumentprovidesinstructionsfortheinstallationandmaintenanceoftheTotalReach
DDSDP.Theintendedaudienceforthisinformationisthecraftpersonresponsibleforthe
installationandmaintenanceoftheequipment.Theseins truct ionsassumefamiliaritywiththe
intendeduseoftheequipment,basicrequiredinstallationskills,andknowledgeof
localand
acceptedsafetypractices.
Additionally,thisdocumentprovidesprovisioninginformationspecifictotheUserInterface
oftheTotalReachDDSDP.Theintendedaudienceforthisinformationissystem
managementpersonnelresponsiblefortheconfigurationofthesoftwareapplications.User
Interfaceprovisioningassumesfamiliaritywiththeintend eduseofthe
equipment ,concepts
peculiartothisproduct,andacomputeroperationsskillset.
RelatedinformationcanbeobtainedbyreferringtotheapplicableJobAid,andSystem
documentation.
901ExplorerBoulevard
P.O. Box140000
Huntsville,AL358144000
UnitedStates
(256)9638000
©2010ADTRAN,Inc.
AllRightsReserved.
®
Revision History
61180105L1-5C iii
Revision History
Conventions
Thefollowingtypographicalconventionsareusedinthisdocument:
Thisfontindicatesacrossreferencelink.
This fontindicatesscreenmenus,fields,andparameters.
THIS FONTindicateskeyboardkeys(ENTER,ESC,ALT).Keysthataretobepressedsimultaneously
areshownwithaplussign(
ALT+X indicatesthattheALT keyandX keyshouldbepressedatthe
sametime
).
Thisfontindicatesreferencestootherdocumentationandisalsousedforemphasis.
This fontindicatesonscreenmessagesandprompts.
This fontindicatestexttobetypedexactlyasshown.
This fontindicatessilkscreenlabelsorothersystemlabelitems.
Thisfontisusedforstrongemphasis.
Revision Date Description
AOctober2001 Initialrelease.
B September2002 Clarifiestestingandinstallation,andaddsoptionmenuscreens.
CJune2010 Correctdipswitchfunction.
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
iv 61180105L1-5C
Hazard Classifications
Thefollowinghazardclassificationsareusedinthisdocument:
DANGER
!
DANGERind i catesahazardwithahighlevelofriskwhich,ifnotavoided,
willresultindeathorseriousinjury.
WARNING
!
WARNI NGindicatesahazardwithamediumlevelofriskwhich,ifnot
avoided,couldresultindeathorseriousinjury.
CAUTION
!
CAUTIONindicatesahazardwithalowlevelofriskwhich,ifnotavoided,
couldresultinminorormoderateinjury.CAUTION canalsobeusedtoalert
againstunsafepracticesassociatedwitheventsthatcouldleadtopersonal
injury.
NOTICE
Noticecalloutsind icateapotentiallyhazardoussituationnotrelatedto
personalinjury,su chasmessagesrelatedtopropertydamageonly.
NOTE
Notesinformtheuserofadditional,butessential,informationorfeatures.
Metric Conversion
TheTotalAccess 1500isdesignedtofitstandard19inchand23inchracks,occupying2Uof
verticalspace.1Uequals1rack unitofverticalheight,whichequals1.75inchesor44.5milli
meters.Thefollowingmetricconversionsapply:
•Height:3.125inches=79.375millimeters
•Width:0.62inches=15.748
millimeters
•2U(3.5inches)=89millimeters
How to Navigate this Document
61180105L1-5C v
How to Navigate this Document
MenusfoundatthesamelevelintheUserInterfaceappearatthesameheadinglevelinthis
document,withthesubmenusarrangedtofollowsequentiallyatlowerheadinglevels.
Toassistinnavigation,aPathHeadingappearsbeloweachtopicheadinginthesesections,
displayingthemenupathto
thatfeature.Forexample:
NOTE
WhenviewingthisdocumentinPDFform,theheadingsshowninblueare
linkstothehighermenulevels.
Network Management
Main Menu\System Controller\Provisioning\Network Management\
Product Name Installation and Maintenance Guide
Current
Menu/Screen
One Level
Above Current
Two Levels
Above Current
Top Level
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
vi 61180105L1-5C
Icons
ThefollowingiconsareusedthroughouttheADTRANdocumentsuite:
Training
ADTRANofferstrainingcoursesonourproducts.Thesecoursesincludeoverviewson
productfeaturesandfunctionswhilecoveringapplicationsofADTRANproductlines.
ADTRANprovidesavarietyoftrainingoptions,includingcustomizedtrainingandcourses
taughtatourfacilitiesoratcustomersites.
Forinquiriesconcerningtraining,contactADTRAN:
TrainingPhone:800
6151176,ext.6303
TrainingFax:2569636217
TrainingEmail:training@adtran.com
deployment guide
installation guide
jobAid
reference guide
diagnostic guide
safety and regulatory
engineering guide
application guide
release notes
upgrade guide
user guide
61180105L1-5C vii
Contents
Scope of this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety and Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Shipping Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Instructions for Installing the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Remote Unit Span Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
False Loopback Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Latching Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Control Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Provisioning and Status DS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Time Slot Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AP-Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
REM Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Out-of-Band Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Protected Loopback (PLB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
A/B Signaling (A/B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Quality Monitor (QM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Total Reach DDS Trouble Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Total Reach DDS-DP Bidirectional Loopback Support . . . . . . . . . . . . . . . . . . . . . . 11
Loopback Pushbutton (Remote Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
viii 61180105L1-5C
Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
General Keyboard Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Remote Provisioning and Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Control Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Provisioning and Status DS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electronic Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Logging on to the Total Access 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Main Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Provisioning Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Data Rate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Loopback Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DDS-DP Time and Date Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DEPLOYMENT GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Appendix A
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Warranty and Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Repair/CAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Repair and Return Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Figures
61180105L1-5C ix
Figures
Figure 1. Total Reach DDS-DP Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2. Option and Rate Selection Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 3. DDS Trouble Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4. DS0 Loopback at the Total Reach DDS-DP . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 5. Total Reach DDS-DP Bidirectional Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 6. Total Reach DDS-DP Response to DDS-R ACE LBK Button . . . . . . . . . . . . . . 12
Figure 7. Total Access 1500 System Logon Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 8. Total Access 1500 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 9. Access Module Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 10. Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 11. Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 12. Provisioning Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 13. Provisioning Menu Showing Invalid Configuration . . . . . . . . . . . . . . . . . . . . . . 20
Figure 14. Data Rate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 15. Status Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 16. Loopback Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 17. DDS-DP Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
x 61180105L1-5C
Tables
Table 1. Topic List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table 2. Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Table 3. Configuration Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 4. Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Table 5. Total Reach Pair Location for Total Access 1500 . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 6. Protected Loopback Mode Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 7. General Keyboard Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 8. Cable Type and Temperature Loss Data @ 13.3 kHz . . . . . . . . . . . . . . . . . . . 25
Table 9. Total Reach DDS Insertion Loss Measurements . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
61180105L1-5C 1
Total Access 1500
Total Reach DDS-DP
Scope of this Guide
ThisdocumentprovidesinstructionsfortheinstallationandmaintenanceoftheTotalAccess
1500TotalReachDDSDP.
Furthermore,thisguideprovidesprovisioningdefaults,UserInterfacefundamentals,and
descriptionsoftheTotalAccess1500TotalReachDDSDPmenus.
ThisguidecontainsthetopicslistedinTable1.
Table 1. Topic List
Topic See Page
Introduction 2
SafetyandRegulatoryCompliance 3
Installation 4
Provisioning 6
GeneralKeyboardCommands 14
MainMenu 16
Maintenance 24
Specifications 25
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
2 61180105L1-5C
Related Documentation
RefertoTable2foradditional,detailedinformati onconcerningtheTotalAccess1500Total
ReachDDSDP.
Table 2. Related Documentation
Title Part Number
TotalAccess1500ComponentlevelDocumentation
TotalAccess1500TotalReachDDSDPJobAid 61180105L122
TotalAccess1500SystemlevelDocumentation
TotalAccess1500SystemManual 61180105L11
Introduction
61180105L1-5C 3
Introduction
ThispracticeprovidesinstallationandmaintenanceproceduresfortheADTRANTotalAccess
1500TotalReachDDSDP(TRDDSDP).Thefigureontheleft,illustratesthefrontpanelofthe
TRDDSDP(P/N61180105L1).
Description
TheTRDDS DPdeliversdataatratesupto64kbpsusingasinglecopperpair.Usedincombi
nationwiththeTotalReachDDSRterminationunit,theTotalReachDDSDPcanaccom
modateextendedlooplengths,eliminatingtheneedforDDSrepeaters.
•TheTRDDSDPspan
powerstheremoteDDSRlocatedatthe customerpremises.
•TheDDSRconvertsthe2wiresignaltothetraditional4wireAlternateMarkInversion
(AMI)signalforpresentationtothecustomer.
TheTRDDSDPoccupiesasinglechannelpositionintheTotalAccess1500chassis.It
providesthe
interfacebetweenaDS0timeslotoftheTcarrierdatastreamandthe2wire
metallicloopextendingtothecustomerpremises.TheTRDDSDPwillinteroperateoverthe
carriersystemwithanotherTRDDSDP,OCUDP,DS0DP,1/0DCS,orswitchandcanbe
located
inanendoffice,huboffice,intermediateoffice,orDigitalLoopCarrier(seeFigure1).
The2wireloopisconnectedusingtheTip(pin15)andtheRing(pin35)ontheTotalAccess
1500backplane.
Figure 1. Total Reach DDS-DP Circuit Diagram
Features
•Allstandardratesto56kbpswithorwithoutsecondarychannel
•64kbpsclearchannel
•2wiredeployment
Repeaterlessoperation
•Bridgedtaptolerant
•SpanpowerforremoteDDSRterminationunit
•UtilizationinallTotalAccess1500rem ote terminalapplications
•Logicleveltestaccess;nonintrusivereceivemonitoringcapability
LoopQualityMonitorandA/Bsignalingoptions
•EmbeddedDigitalSystem6capabilitiesforremoteprovisioning,configuration,and
performancemonitoring
ProvisioningviaDB9craftinterfaceonTotalAccess1500SystemControllerUnit(SCU).
BidirectionalloopbackduringlocalDS0latchingloopback
Total Access 1500
TR
DDS-
DP
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
4 61180105L1-5C
•Protectedloopbackeliminatesfalselatchingloopbackoccurrences
SupportsDDSlatchingloopbackstandardT1E1.2/99007R1
Safety and Regulatory Compliance
CAUTION
!
ElectrostaticDischarge (ESD) candamage electronicmodules. When
handlingmodules,wea r an ant istaticdischargewriststraptoprevent
damagetoelectron iccomponents.Place mod ulesinantistaticpacking
materialwhentransportingorstoring.Whenworkingonmodules,always
placethemonanapprovedantistaticmatthatiselectricallygrounded.
Table3showstheconfigurationcodesfortheTRDDSDP.TheTRDDSDPisNRTLlis tedto
theapplicableULstandards.TheTRDDSDPistobeinstalledinarestrictedaccesslocation
only.
Thisdevicecomplies
withPart15oftheFCCrules.Operationissubjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRANcouldvoidtheusers
authoritytooperatethis
equipment.
Table 3. Configuration Codes
Configuration Code Input Output
PowerCode(PC) F C
TelecommunicationCode(TC) X
InstallationCode(IC) A
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Installation
61180105L1-5C 5
Installation
Afterunpackingtheunit,inspectitfordamage.Ifdamageisdiscovered,fileaclaimwiththe
carrier,thencontactADTRAN.RefertoWarrantyandCustomerService.
Shipping Contents
Thecontentsincludethefollowingitems:
•TotalReachDDSDP
TotalAccess1500TotalReachDDSDPJobAid(P/N61180105L122)
Instructions for Installing the Module
TheTRDDSDPplugsdirectlyintoaTotalAccess1500shelf.Nospecialwiringisrequired.
The2wireloopusestheT/R(Tipand Ring)pair,pins15and35,oftheTotalAccess1500
backplane.
Remote Unit Span Power
TheTRDDSDPspanpowerstheremoteunitbyproviding‐130VDCmeasuredfromTipto
Ring.VoltagemeasuredfromTiptoGNDshouldbe‐130VDCorlessdependingonvoltmeter
impedance.VoltagefromRingtoGNDshouldindicateapproximately0V.
Front Panel LEDs
TheTRDDSDPprovidesfrontpanelLEDstodisplaystatusinformation.TheTRDDSDP
LEDsandstatusdescriptionsareshowninTable4.
Table 4. Front Panel LEDs
LED Condition Description
STATUS
{
z
2
z
z
2
Off
Green
YellowFlashing
Yellow
Red
FlashingRed
Nopowerormalfunction
Normalsynchronizedoperatingcondition
Loopbackactiveatremoteunit
LoopbackactiveatDDSDP
Indicatesoneofthethreeconditions:
1. Lossofsealingcurrent
2. Lossof,ornosynchronization
3. PoorsignalqualitywhenQMenabled(SW15ON)
CRCerrorsnearorfar
REM
{
z
2
Off
Green
FlashingGreen
Nopowerormalfunction
Remoteprovisioningineffect
DS6controllinkestablished
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
6 61180105L1-5C
Synchronization
TheTRDDSDPandDDSRtypicallyrequire30to90secondstosynchronize.Oncesynchro
nized,theStatusLEDwillturnONgreen.Ifsynchronizationcannotbeachieved,checktheT/
Rpairforopencircuitorshortcircuitconditionsorloadcoils.
Connections
Allconnectionsaremadethroughthe50pinAmphenolconnectoronthebackplaneofthe
TotalAccess1500.SeeTable5.
Table 5. Total Reach Pair Location for Total Access 1500
Total
Access
1500 Slot
Port 1
T/R (P1)
Total
Access
1500 Slot
Port 1
T/R (P1)
1
26/1 13 38/13
227/2 14 39/14
328/3 15 40/15
429/4 16 41/16
530/5 17 42/17
631/6 18 43/18
732/7 19 44/19
833/8 20 45/20
934/9 21 46/21
10 35/10 22 47/22
11 36/11 23 48/23
12 37/12 24 49/24
Provisioning
61180105L1-5C 7
Provisioning
Oninitialinstallation,theTRDDSDPisprovisionedaccordingtothefactorydefaultsettings.
False Loopback Immunity
ADTRAN’s ProtectedLoopbackfamilyofchannelunitsincludesanalgorithmcompatible
withSARTS,Hekimian,TPI,andothertestsystemsthatvirtuallyeliminatefalselatching
loopbacks.Immunityisautomaticallyenabledat64kbps.
Inaddition,ADTRAN’sProtectedLoopbackfamilyfeaturesaprotectedloopbackmodefor
furtherfalselatchingloopbackprotection.
Latching Loopback
Latchingloopbacksarealwaysenabledexceptwhentemporarilydisabledviatheprotect
loopbackfeatures.When64kbpsisenabled,placing
SW1-3 (PLB)toOFFwillpermittheTR
DDSDPtorespondtothelegacylatchingloopbacksequenceasdescribedinTR62310and
ANSIT1.107.At64kbps,placing
SW1-3toON,theTRDDSDPwillenableADTRAN’s
ProtectedLoopbackmode.
Control Protocol
RemoteaccesstoprovisioningandstatusinformationisaccomplishedusingeitherADTRAN
DigitalSystem6MessageprotocoldefinedinControlandDiagnosticProceduresPractice,
Section60329916,orthroughthecraftinterfaceontheTotalAccess1500SCU.DigitalSystem
6issupportedbytheTPI108/109and105portabletest
setsandissupportedbyHekimian
React2001Revision1900remotetestsystem.
TheTRDDSDPnetworkelementscomplywithANSIT1.1071995,“DigitalHierarchyFormat
SpecificationsAnnexG”whichallowsremoteprovisioning,querying,andperformance
monitoringviainbandcontrolofnetworkelements.
NOTE
TheREACT2001GUIsoftwareRelease1.900supportsANSIT1.1071995.
RemoteaccessisaccomplishedusingadefinedsetofinbandDS0bytesequencessimilarto
thelatchingloopbacksequence.Commandsissuedviathetestsystemarerecognizedbythe
individualchannelunitwhichrespondswiththeappropriatebytesequences.
Theseinband
commandscanbeusedtoverifyoptionsviadialogswithREACT 2001,TPI108/109andTPI
105testsets.UnitCLEI,serialnumber,provisioning,andperformanceinformationcanbe
retrievedremotelyusingtheDigitalSystem6protocol.
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
8 61180105L1-5C
Provisioning and Status DS6
AllconfigurationoptionscanberemotelyviewedorprovisionedviaDS6.Thefrontpanel
remote(
REM)LEDindicatorflashesduringDS6controllinkestablishmentandremainsON
afterthechannelunithasbeenremotelyprovisioned.Thenewestprovisioningwilloverwrite
anyexistingprovisioningcontainedontheTRDDSDP.
Time Slot Assignment
TheTotalAccess1500platformcanhavemultipletimeslotsintheT1datastreamassignedto
eachphysicalslotinthechannelbank.TheTotalAccess1500allowscraftselectabletimeslots
usingtheelectronicprovisioninginterface.
AP-Switch
Ifthechannelunithasbeenremotelyprovisioned,theoperatorcanalternatebetweenremote
configurationandmanualswitchsettingsbypressingthemomentaryAlternateProvisioning
(
AP)switchlocatedonthefrontpanel.Ifthechannelunitisremovedfromthesystem,the
TotalAccess1500bankslotretainsthelastremoteprovisioninginformation.AsimilarTR
DDSDPplacedinthatslotwillassumethesameremoteprovisioning.
REM Indicator
TheREMindicatorremainsONwhenthechannelunitisoperatingbasedonremoteprovi
sioning,andisOFFwhenoperatingonmanualswitches.Ifthechannelunithasneverbeen
remotelyprovisioned,the
APswitchhasnoeffectandtheREMindicatorremainsOFF.See
Table 4onpage 5forLEDindication.
Out-of-Band Diagnostics
InadditiontoinbandaccesstoTRDDSDPperformancediagnostics andprovisioningvia
DigitalSystem6,accessisalsoavailableoutofba nd(nonintrusively)viathecraftinterface
locatedontheTotalReachDDSR.
TheTRDDSDPdisplaysprovisioninginformation,TotalReachsystemstatus,performance
monitoring
informationstoredin15minuteand24hourregistersforboththeTotalReach
DDSDPandTotalReachDDSR,andaneventlogwhichtimestampssystemperformance
anomaliesandthresholdviolations.
PhysicalaccesstotheterminalinterfaceontheTotalReachDDSRismadebya
serialinterface
connectiontoadumbterminalordumbterminalemulation.ProvisioningoftheTRDDSDP
maybeviewedbutnotchangedfromtheterminalinterfaceontheTotalReachDDSR.
FurtherinformationabouttheTotalReachterminalinterfaceandperformancemonitoring
maybefoundintheTotalReach
OCURFrameIQwithCraftInterfaceAllRateDDSTermination
UnitInstallationandMaintenancePracticeP/N61291023L25.
Provisioning
61180105L1-5C 9
Options
Selectthe appropriateOp tionandRateusingcircuitboardswitchesSW1andSW4asillustratedin
Figure2.Selectoptionspriortoboardinsertion.
Figure 2. Option and Rate Selection Switches
Protected Loopback (PLB)
ADTRAN’s ProtectedLoopbacksupportsthenewproposed DDSlatchingloopbackstandard
inT1E1.2/99007R1.WhenProtectedLoopbackisenabled,theTRDDSDPwillrespondto
latchingloopbackwhentheidlecodepreambleissentprior tothelatchingloopbacksequence
specifiedinTR62310andANSIT1.107.
ProtectedLoopbackpreventsfalse
latchingloopbackswhentheloopbacksequenceis
embeddedincustomerpayloaddata.TestequipmentshouldsupportT1E1.2/99007R1to
performtestingat64kbpswhenprotectedloopbackisenabled.
SeeTable6forthelatchingloopbacksequencerequirementwhenProtectedLoopbackis
enabled.
Table 6. Protected Loopback Mode Requirement
Sequence Function Byte Code # of Received Bytes
ExitDataProtocol Idle‐11111110 Minimumof35Idlebytes
Clearexistingloopbacks Transitionin
progress(TIP)
X0111010
Minimumof35TIPbytes
Identifydevicetobelooped Loopbackselectcode(LSC)
X0000101‐DS0
X1010101‐OCU
X0110001‐CSU
X1000001‐NIE
Minimumof35LSCbytes
Preparetoloop;sendMAPcode
after30bytes
Loopbackenabled(LBE)
X1010110
Minimumof100LBE
bytes
Activateloopback FarEndvoice(FEV)
X1011010
Minimumof32FEVbytes
1
1
1
O
N
O
N
O
N
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
1
1
1
O
N
O
N
O
N
2
2
2
3
3
3
4
4
4
5
5
5
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
10 61180105L1-5C
NOTE
A minimumof 35 TIPbytes is re quiredtodisableestablished latching
loopback.X=DonʹtCarebit.
A/B Signaling (A/B)
WhenA/BSignaling(SW1-4)isOFF,theunitderivessignalingfromtheincomingdatastream.
WhenA/BSignalingisON,theunitdeterminesthestateoftheAandBSignalingbitsusing
signalspresentonthebackplaneofthechannelbank.Thismethodassumesthatproper
signalinghasbeenmaintainedthroughoutnetworktandems
andcrossconnectsystems.
NOTE
A/BSignalingop tio n isonlyapplicablewhenSW56isselected;otherwiseitisa
“don’tcare.”
Quality Monitor (QM)
WhenQualityMonitor(SW1-5)isON,theTRDDSDPmonitorstheincoming2wireloopand
4wirecustomerinterfacedataforerrors.Ifexcessiveerrorsaredetected,theunitblocksthe
customersdatatransmissionandtransmitsanalternatingMOS(9Ah)/ASC(9Eh)troublecode
tothenetwork.Customerdatatransmissionisautomaticallyrestoredwhen
thetrouble
conditioniscleared.
Rate Selection
Selectratewithdipswitch(SW4)bypositioningtheselectedswitchtowardtheinscribedrate.
NOTE
Selectonlyonerate.Moreth anone,ornone,defaultsto56kbpswithout
secondarychannel.
NOTE
IfeitherSW56or64kbpsisse lected,thesecondarychannel(SC)switch
shouldnotbeselected.
1/40