Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
ii 61180105L1-5C
Front Matter
Trademarks
Brandnamesandproductnamesincludedinthisdocumentaretrademarks,registeredtrade
marks,ortradenamesoftheirrespectiveholders.
To the Holder of this Document
Thecontentsofthisdocumentarecurrentasofthedateofpublication.ADTRAN
®
reserves
therighttochangethecontentswithoutpriornotice.
InnoeventwillADTRANbeliableforanyspecial,incidental,orconsequentialdamagesor
forcommerciallossesevenifADTRANhasbeenadvisedthereofasaresultofissueofthis
document.
About this Document
ThisdocumentprovidesinstructionsfortheinstallationandmaintenanceoftheTotalReach
DDSDP.Theintendedaudienceforthisinformationisthecraftpersonresponsibleforthe
installationandmaintenanceoftheequipment.Theseins truct ionsassumefamiliaritywiththe
intendeduseoftheequipment,basicrequiredinstallationskills,andknowledgeof
localand
acceptedsafetypractices.
Additionally,thisdocumentprovidesprovisioninginformationspecifictotheUserInterface
oftheTotalReachDDSDP.Theintendedaudienceforthisinformationissystem
managementpersonnelresponsiblefortheconfigurationofthesoftwareapplications.User
Interfaceprovisioningassumesfamiliaritywiththeintend eduseofthe
equipment ,concepts
peculiartothisproduct,andacomputeroperationsskillset.
RelatedinformationcanbeobtainedbyreferringtotheapplicableJobAid,andSystem
documentation.
901ExplorerBoulevard
P.O. Box140000
Huntsville,AL358144000
UnitedStates
(256)9638000
©2010ADTRAN,Inc.
AllRightsReserved.
®
Revision History
61180105L1-5C iii
Revision History
Conventions
Thefollowingtypographicalconventionsareusedinthisdocument:
Thisfontindicatesacrossreferencelink.
This fontindicatesscreenmenus,fields,andparameters.
THIS FONTindicateskeyboardkeys(ENTER,ESC,ALT).Keysthataretobepressedsimultaneously
areshownwithaplussign(
ALT+X indicatesthattheALT keyandX keyshouldbepressedatthe
sametime
).
Thisfontindicatesreferencestootherdocumentationandisalsousedforemphasis.
This fontindicatesonscreenmessagesandprompts.
This fontindicatestexttobetypedexactlyasshown.
This fontindicatessilkscreenlabelsorothersystemlabelitems.
Thisfontisusedforstrongemphasis.
Revision Date Description
AOctober2001 Initialrelease.
B September2002 Clarifiestestingandinstallation,andaddsoptionmenuscreens.
CJune2010 Correctdipswitchfunction.
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
iv 61180105L1-5C
Hazard Classifications
Thefollowinghazardclassificationsareusedinthisdocument:
DANGER
!
DANGERind i catesahazardwithahighlevelofriskwhich,ifnotavoided,
willresultindeathorseriousinjury.
WARNING
!
WARNI NGindicatesahazardwithamediumlevelofriskwhich,ifnot
avoided,couldresultindeathorseriousinjury.
CAUTION
!
CAUTIONindicatesahazardwithalowlevelofriskwhich,ifnotavoided,
couldresultinminorormoderateinjury.CAUTION canalsobeusedtoalert
againstunsafepracticesassociatedwitheventsthatcouldleadtopersonal
injury.
NOTICE
Noticecalloutsind icateapotentiallyhazardoussituationnotrelatedto
personalinjury,su chasmessagesrelatedtopropertydamageonly.
NOTE
Notesinformtheuserofadditional,butessential,informationorfeatures.
Metric Conversion
TheTotalAccess 1500isdesignedtofitstandard19inchand23inchracks,occupying2Uof
verticalspace.1Uequals1rack unitofverticalheight,whichequals1.75inchesor44.5milli
meters.Thefollowingmetricconversionsapply:
•Height:3.125inches=79.375millimeters
•Width:0.62inches=15.748
millimeters
•2U(3.5inches)=89millimeters
How to Navigate this Document
61180105L1-5C v
How to Navigate this Document
MenusfoundatthesamelevelintheUserInterfaceappearatthesameheadinglevelinthis
document,withthesubmenusarrangedtofollowsequentiallyatlowerheadinglevels.
Toassistinnavigation,aPathHeadingappearsbeloweachtopicheadinginthesesections,
displayingthemenupathto
thatfeature.Forexample:
NOTE
WhenviewingthisdocumentinPDFform,theheadingsshowninblueare
linkstothehighermenulevels.
Network Management
Main Menu\System Controller\Provisioning\Network Management\
Product Name Installation and Maintenance Guide
Current
Menu/Screen
One Level
Above Current
Two Levels
Above Current
Top Level
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
vi 61180105L1-5C
Icons
ThefollowingiconsareusedthroughouttheADTRANdocumentsuite:
Training
ADTRANofferstrainingcoursesonourproducts.Thesecoursesincludeoverviewson
productfeaturesandfunctionswhilecoveringapplicationsofADTRANproductlines.
ADTRANprovidesavarietyoftrainingoptions,includingcustomizedtrainingandcourses
taughtatourfacilitiesoratcustomersites.
Forinquiriesconcerningtraining,contactADTRAN:
TrainingPhone:800
6151176,ext.6303
TrainingFax:2569636217
TrainingEmail:[email protected]
deployment guide
installation guide
jobAid
reference guide
diagnostic guide
safety and regulatory
engineering guide
application guide
release notes
upgrade guide
user guide
61180105L1-5C vii
Contents
Scope of this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety and Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Shipping Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Instructions for Installing the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Remote Unit Span Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
False Loopback Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Latching Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Control Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Provisioning and Status DS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Time Slot Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AP-Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
REM Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Out-of-Band Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Protected Loopback (PLB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
A/B Signaling (A/B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Quality Monitor (QM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Total Reach DDS Trouble Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Total Reach DDS-DP Bidirectional Loopback Support . . . . . . . . . . . . . . . . . . . . . . 11
Loopback Pushbutton (Remote Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
viii 61180105L1-5C
Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
General Keyboard Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Remote Provisioning and Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Control Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Provisioning and Status DS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electronic Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Logging on to the Total Access 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Main Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Provisioning Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Data Rate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Loopback Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DDS-DP Time and Date Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DEPLOYMENT GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Appendix A
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Warranty and Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Customer Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Sales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
ADTRAN Repair/CAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Repair and Return Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Figures
61180105L1-5C ix
Figures
Figure 1. Total Reach DDS-DP Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2. Option and Rate Selection Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 3. DDS Trouble Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4. DS0 Loopback at the Total Reach DDS-DP . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 5. Total Reach DDS-DP Bidirectional Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 6. Total Reach DDS-DP Response to DDS-R ACE LBK Button . . . . . . . . . . . . . . 12
Figure 7. Total Access 1500 System Logon Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 8. Total Access 1500 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 9. Access Module Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 10. Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 11. Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 12. Provisioning Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 13. Provisioning Menu Showing Invalid Configuration . . . . . . . . . . . . . . . . . . . . . . 20
Figure 14. Data Rate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 15. Status Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 16. Loopback Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 17. DDS-DP Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
x 61180105L1-5C
Tables
Table 1. Topic List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table 2. Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Table 3. Configuration Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 4. Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Table 5. Total Reach Pair Location for Total Access 1500 . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 6. Protected Loopback Mode Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 7. General Keyboard Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 8. Cable Type and Temperature Loss Data @ 13.3 kHz . . . . . . . . . . . . . . . . . . . 25
Table 9. Total Reach DDS Insertion Loss Measurements . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
61180105L1-5C 1
Total Access 1500
Total Reach DDS-DP
Scope of this Guide
ThisdocumentprovidesinstructionsfortheinstallationandmaintenanceoftheTotalAccess
1500TotalReachDDSDP.
Furthermore,thisguideprovidesprovisioningdefaults,UserInterfacefundamentals,and
descriptionsoftheTotalAccess1500TotalReachDDSDPmenus.
ThisguidecontainsthetopicslistedinTable1.
Table 1. Topic List
Topic See Page
Introduction 2
SafetyandRegulatoryCompliance 3
Installation 4
Provisioning 6
GeneralKeyboardCommands 14
MainMenu 16
Maintenance 24
Specifications 25
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
2 61180105L1-5C
Related Documentation
RefertoTable2foradditional,detailedinformati onconcerningtheTotalAccess1500Total
ReachDDSDP.
Table 2. Related Documentation
Title Part Number
TotalAccess1500ComponentlevelDocumentation
TotalAccess1500TotalReachDDSDPJobAid 61180105L122
TotalAccess1500SystemlevelDocumentation
TotalAccess1500SystemManual 61180105L11
Introduction
61180105L1-5C 3
Introduction
ThispracticeprovidesinstallationandmaintenanceproceduresfortheADTRANTotalAccess
1500TotalReachDDSDP(TRDDSDP).Thefigureontheleft,illustratesthefrontpanelofthe
TRDDSDP(P/N61180105L1).
Description
TheTRDDS DPdeliversdataatratesupto64kbpsusingasinglecopperpair.Usedincombi
nationwiththeTotalReachDDSRterminationunit,theTotalReachDDSDPcanaccom
modateextendedlooplengths,eliminatingtheneedforDDSrepeaters.
•TheTRDDSDPspan
powerstheremoteDDSRlocatedatthe customerpremises.
•TheDDSRconvertsthe2wiresignaltothetraditional4wireAlternateMarkInversion
(AMI)signalforpresentationtothecustomer.
TheTRDDSDPoccupiesasinglechannelpositionintheTotalAccess1500chassis.It
providesthe
interfacebetweenaDS0timeslotoftheTcarrierdatastreamandthe2wire
metallicloopextendingtothecustomerpremises.TheTRDDSDPwillinteroperateoverthe
carriersystemwithanotherTRDDSDP,OCUDP,DS0DP,1/0DCS,orswitchandcanbe
located
inanendoffice,huboffice,intermediateoffice,orDigitalLoopCarrier(seeFigure1).
The2wireloopisconnectedusingtheTip(pin15)andtheRing(pin35)ontheTotalAccess
1500backplane.
Figure 1. Total Reach DDS-DP Circuit Diagram
Features
•Allstandardratesto56kbpswithorwithoutsecondarychannel
•64kbpsclearchannel
•2wiredeployment
Repeaterlessoperation
•Bridgedtaptolerant
•SpanpowerforremoteDDSRterminationunit
•UtilizationinallTotalAccess1500rem ote terminalapplications
•Logicleveltestaccess;nonintrusivereceivemonitoringcapability
LoopQualityMonitorandA/Bsignalingoptions
•EmbeddedDigitalSystem6capabilitiesforremoteprovisioning,configuration,and
performancemonitoring
ProvisioningviaDB9craftinterfaceonTotalAccess1500SystemControllerUnit(SCU).
BidirectionalloopbackduringlocalDS0latchingloopback
Total Access 1500
TR
DDS-
DP
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
4 61180105L1-5C
•Protectedloopbackeliminatesfalselatchingloopbackoccurrences
SupportsDDSlatchingloopbackstandardT1E1.2/99007R1
Safety and Regulatory Compliance
CAUTION
!
ElectrostaticDischarge (ESD) candamage electronicmodules. When
handlingmodules,wea r an ant istaticdischargewriststraptoprevent
damagetoelectron iccomponents.Place mod ulesinantistaticpacking
materialwhentransportingorstoring.Whenworkingonmodules,always
placethemonanapprovedantistaticmatthatiselectricallygrounded.
Table3showstheconfigurationcodesfortheTRDDSDP.TheTRDDSDPisNRTLlis tedto
theapplicableULstandards.TheTRDDSDPistobeinstalledinarestrictedaccesslocation
only.
Thisdevicecomplies
withPart15oftheFCCrules.Operationissubjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRANcouldvoidtheusers
authoritytooperatethis
equipment.
Table 3. Configuration Codes
Configuration Code Input Output
PowerCode(PC) F C
TelecommunicationCode(TC) X
InstallationCode(IC) A
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Installation
61180105L1-5C 5
Installation
Afterunpackingtheunit,inspectitfordamage.Ifdamageisdiscovered,fileaclaimwiththe
carrier,thencontactADTRAN.RefertoWarrantyandCustomerService.
Shipping Contents
Thecontentsincludethefollowingitems:
•TotalReachDDSDP
TotalAccess1500TotalReachDDSDPJobAid(P/N61180105L122)
Instructions for Installing the Module
TheTRDDSDPplugsdirectlyintoaTotalAccess1500shelf.Nospecialwiringisrequired.
The2wireloopusestheT/R(Tipand Ring)pair,pins15and35,oftheTotalAccess1500
backplane.
Remote Unit Span Power
TheTRDDSDPspanpowerstheremoteunitbyproviding‐130VDCmeasuredfromTipto
Ring.VoltagemeasuredfromTiptoGNDshouldbe‐130VDCorlessdependingonvoltmeter
impedance.VoltagefromRingtoGNDshouldindicateapproximately0V.
Front Panel LEDs
TheTRDDSDPprovidesfrontpanelLEDstodisplaystatusinformation.TheTRDDSDP
LEDsandstatusdescriptionsareshowninTable4.
Table 4. Front Panel LEDs
LED Condition Description
STATUS
{
z
2
z
z
2
Off
Green
YellowFlashing
Yellow
Red
FlashingRed
Nopowerormalfunction
Normalsynchronizedoperatingcondition
Loopbackactiveatremoteunit
LoopbackactiveatDDSDP
Indicatesoneofthethreeconditions:
1. Lossofsealingcurrent
2. Lossof,ornosynchronization
3. PoorsignalqualitywhenQMenabled(SW15ON)
CRCerrorsnearorfar
REM
{
z
2
Off
Green
FlashingGreen
Nopowerormalfunction
Remoteprovisioningineffect
DS6controllinkestablished
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
6 61180105L1-5C
Synchronization
TheTRDDSDPandDDSRtypicallyrequire30to90secondstosynchronize.Oncesynchro
nized,theStatusLEDwillturnONgreen.Ifsynchronizationcannotbeachieved,checktheT/
Rpairforopencircuitorshortcircuitconditionsorloadcoils.
Connections
Allconnectionsaremadethroughthe50pinAmphenolconnectoronthebackplaneofthe
TotalAccess1500.SeeTable5.
Table 5. Total Reach Pair Location for Total Access 1500
Total
Access
1500 Slot
Port 1
T/R (P1)
Total
Access
1500 Slot
Port 1
T/R (P1)
1
26/1 13 38/13
227/2 14 39/14
328/3 15 40/15
429/4 16 41/16
530/5 17 42/17
631/6 18 43/18
732/7 19 44/19
833/8 20 45/20
934/9 21 46/21
10 35/10 22 47/22
11 36/11 23 48/23
12 37/12 24 49/24
Provisioning
61180105L1-5C 7
Provisioning
Oninitialinstallation,theTRDDSDPisprovisionedaccordingtothefactorydefaultsettings.
False Loopback Immunity
ADTRAN’s ProtectedLoopbackfamilyofchannelunitsincludesanalgorithmcompatible
withSARTS,Hekimian,TPI,andothertestsystemsthatvirtuallyeliminatefalselatching
loopbacks.Immunityisautomaticallyenabledat64kbps.
Inaddition,ADTRAN’sProtectedLoopbackfamilyfeaturesaprotectedloopbackmodefor
furtherfalselatchingloopbackprotection.
Latching Loopback
Latchingloopbacksarealwaysenabledexceptwhentemporarilydisabledviatheprotect
loopbackfeatures.When64kbpsisenabled,placing
SW1-3 (PLB)toOFFwillpermittheTR
DDSDPtorespondtothelegacylatchingloopbacksequenceasdescribedinTR62310and
ANSIT1.107.At64kbps,placing
SW1-3toON,theTRDDSDPwillenableADTRAN’s
ProtectedLoopbackmode.
Control Protocol
RemoteaccesstoprovisioningandstatusinformationisaccomplishedusingeitherADTRAN
DigitalSystem6MessageprotocoldefinedinControlandDiagnosticProceduresPractice,
Section60329916,orthroughthecraftinterfaceontheTotalAccess1500SCU.DigitalSystem
6issupportedbytheTPI108/109and105portabletest
setsandissupportedbyHekimian
React2001Revision1900remotetestsystem.
TheTRDDSDPnetworkelementscomplywithANSIT1.1071995,“DigitalHierarchyFormat
SpecificationsAnnexG”whichallowsremoteprovisioning,querying,andperformance
monitoringviainbandcontrolofnetworkelements.
NOTE
TheREACT2001GUIsoftwareRelease1.900supportsANSIT1.1071995.
RemoteaccessisaccomplishedusingadefinedsetofinbandDS0bytesequencessimilarto
thelatchingloopbacksequence.Commandsissuedviathetestsystemarerecognizedbythe
individualchannelunitwhichrespondswiththeappropriatebytesequences.
Theseinband
commandscanbeusedtoverifyoptionsviadialogswithREACT 2001,TPI108/109andTPI
105testsets.UnitCLEI,serialnumber,provisioning,andperformanceinformationcanbe
retrievedremotelyusingtheDigitalSystem6protocol.
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
8 61180105L1-5C
Provisioning and Status DS6
AllconfigurationoptionscanberemotelyviewedorprovisionedviaDS6.Thefrontpanel
remote(
REM)LEDindicatorflashesduringDS6controllinkestablishmentandremainsON
afterthechannelunithasbeenremotelyprovisioned.Thenewestprovisioningwilloverwrite
anyexistingprovisioningcontainedontheTRDDSDP.
Time Slot Assignment
TheTotalAccess1500platformcanhavemultipletimeslotsintheT1datastreamassignedto
eachphysicalslotinthechannelbank.TheTotalAccess1500allowscraftselectabletimeslots
usingtheelectronicprovisioninginterface.
AP-Switch
Ifthechannelunithasbeenremotelyprovisioned,theoperatorcanalternatebetweenremote
configurationandmanualswitchsettingsbypressingthemomentaryAlternateProvisioning
(
AP)switchlocatedonthefrontpanel.Ifthechannelunitisremovedfromthesystem,the
TotalAccess1500bankslotretainsthelastremoteprovisioninginformation.AsimilarTR
DDSDPplacedinthatslotwillassumethesameremoteprovisioning.
REM Indicator
TheREMindicatorremainsONwhenthechannelunitisoperatingbasedonremoteprovi
sioning,andisOFFwhenoperatingonmanualswitches.Ifthechannelunithasneverbeen
remotelyprovisioned,the
APswitchhasnoeffectandtheREMindicatorremainsOFF.See
Table 4onpage 5forLEDindication.
Out-of-Band Diagnostics
InadditiontoinbandaccesstoTRDDSDPperformancediagnostics andprovisioningvia
DigitalSystem6,accessisalsoavailableoutofba nd(nonintrusively)viathecraftinterface
locatedontheTotalReachDDSR.
TheTRDDSDPdisplaysprovisioninginformation,TotalReachsystemstatus,performance
monitoring
informationstoredin15minuteand24hourregistersforboththeTotalReach
DDSDPandTotalReachDDSR,andaneventlogwhichtimestampssystemperformance
anomaliesandthresholdviolations.
PhysicalaccesstotheterminalinterfaceontheTotalReachDDSRismadebya
serialinterface
connectiontoadumbterminalordumbterminalemulation.ProvisioningoftheTRDDSDP
maybeviewedbutnotchangedfromtheterminalinterfaceontheTotalReachDDSR.
FurtherinformationabouttheTotalReachterminalinterfaceandperformancemonitoring
maybefoundintheTotalReach
OCURFrameIQwithCraftInterfaceAllRateDDSTermination
UnitInstallationandMaintenancePracticeP/N61291023L25.
Provisioning
61180105L1-5C 9
Options
Selectthe appropriateOp tionandRateusingcircuitboardswitchesSW1andSW4asillustratedin
Figure2.Selectoptionspriortoboardinsertion.
Figure 2. Option and Rate Selection Switches
Protected Loopback (PLB)
ADTRAN’s ProtectedLoopbacksupportsthenewproposed DDSlatchingloopbackstandard
inT1E1.2/99007R1.WhenProtectedLoopbackisenabled,theTRDDSDPwillrespondto
latchingloopbackwhentheidlecodepreambleissentprior tothelatchingloopbacksequence
specifiedinTR62310andANSIT1.107.
ProtectedLoopbackpreventsfalse
latchingloopbackswhentheloopbacksequenceis
embeddedincustomerpayloaddata.TestequipmentshouldsupportT1E1.2/99007R1to
performtestingat64kbpswhenprotectedloopbackisenabled.
SeeTable6forthelatchingloopbacksequencerequirementwhenProtectedLoopbackis
enabled.
Table 6. Protected Loopback Mode Requirement
Sequence Function Byte Code # of Received Bytes
ExitDataProtocol Idle‐11111110 Minimumof35Idlebytes
Clearexistingloopbacks Transitionin
progress(TIP)
X0111010
Minimumof35TIPbytes
Identifydevicetobelooped Loopbackselectcode(LSC)
X0000101‐DS0
X1010101‐OCU
X0110001‐CSU
X1000001‐NIE
Minimumof35LSCbytes
Preparetoloop;sendMAPcode
after30bytes
Loopbackenabled(LBE)
X1010110
Minimumof100LBE
bytes
Activateloopback FarEndvoice(FEV)
X1011010
Minimumof32FEVbytes
1
1
1
O
N
O
N
O
N
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
1
1
1
O
N
O
N
O
N
2
2
2
3
3
3
4
4
4
5
5
5
Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
10 61180105L1-5C
NOTE
A minimumof 35 TIPbytes is re quiredtodisableestablished latching
loopback.X=DonʹtCarebit.
A/B Signaling (A/B)
WhenA/BSignaling(SW1-4)isOFF,theunitderivessignalingfromtheincomingdatastream.
WhenA/BSignalingisON,theunitdeterminesthestateoftheAandBSignalingbitsusing
signalspresentonthebackplaneofthechannelbank.Thismethodassumesthatproper
signalinghasbeenmaintainedthroughoutnetworktandems
andcrossconnectsystems.
NOTE
A/BSignalingop tio n isonlyapplicablewhenSW56isselected;otherwiseitisa
“don’tcare.”
Quality Monitor (QM)
WhenQualityMonitor(SW1-5)isON,theTRDDSDPmonitorstheincoming2wireloopand
4wirecustomerinterfacedataforerrors.Ifexcessiveerrorsaredetected,theunitblocksthe
customersdatatransmissionandtransmitsanalternatingMOS(9Ah)/ASC(9Eh)troublecode
tothenetwork.Customerdatatransmissionisautomaticallyrestoredwhen
thetrouble
conditioniscleared.
Rate Selection
Selectratewithdipswitch(SW4)bypositioningtheselectedswitchtowardtheinscribedrate.
NOTE
Selectonlyonerate.Moreth anone,ornone,defaultsto56kbpswithout
secondarychannel.
NOTE
IfeitherSW56or64kbpsisse lected,thesecondarychannel(SC)switch
shouldnotbeselected.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

ADTRAN Total Access 1500 Installation and Maintenance

Type
Installation and Maintenance

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI