CMA Dishmachines GL-X Quick Setup Instructions

Type
Quick Setup Instructions

CMA Dishmachines GL-X is a commercial-grade dishwasher designed for heavy-duty cleaning of dishes, glassware, and utensils in restaurants, hotels, and other foodservice establishments. It features a 1/2" water inlet, leveling legs for stability, and a drain hose that can be connected to a wall or floor drain. The GL-X requires a dedicated circuit breaker and should be hard-wired by a licensed electrician. It has a temperature display and adjustable thermostat, allowing you to set the desired water temperature for optimal cleaning results.

CMA Dishmachines GL-X is a commercial-grade dishwasher designed for heavy-duty cleaning of dishes, glassware, and utensils in restaurants, hotels, and other foodservice establishments. It features a 1/2" water inlet, leveling legs for stability, and a drain hose that can be connected to a wall or floor drain. The GL-X requires a dedicated circuit breaker and should be hard-wired by a licensed electrician. It has a temperature display and adjustable thermostat, allowing you to set the desired water temperature for optimal cleaning results.

GL-X REAR VIEW
1
STEP
WALL DRAIN
FLOOR DRAIN
1"AIR GAP
Connect the drain hose to wall or floor drain.
The floor drain must have a 1 inch air gap
between drain hose and floor drain.
HARD WIRE
POWER SUPPLY
2
LEVELING
LEGS
3
GL-X
Quick Setup
Instructions
DRAIN VALVE
DRAIN HOSE
1
1/2" WATER
INLET
4
Insert tube stiffener with chemical tubing into
corresponding chemical dispensers.
5
STEP
BLUE RED
WHITE
5
CHEMICAL
TUBING
5
TUBE
STIFFENER
11-2016
WARNING: Electrical and plumbing
connections need to be made by a
licensed service person and comply
with all Federal, State and Local
Health, Electrical, Plumbing and
Safety codes.
2
STEP
DO NOT USE POWER CORD OR GFI OUTLET.
This unit MUST BE hard-wired to a dedicated
appropriatley size circuit breaker.
GFI
GFI
Connect dishmachine to hot water source,
recommended 140
0
(120
0
minimum temperature
required) using a 1/2"connector.
4
STEP
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front and back to
ensure proper performance.
3
STEP
PN: 10130.04
OFF POWER ON
MIN TEMP 120
0
DRAIN
START
DISHMACHINES
PRIMER SWITCHES
GL-X FRONT VIEW
STEP
CHEMICAL PUMPS
THERMOSTAT
POWER
6
FILL/START
7
DRAIN
10
9
8
WASH
TEMPERATURE
DISPLAY
Push "DRAIN" switch to empty machine.
10
STEP
OFF POWER ON
DRAIN
FILL/START
FILL
Turn Power Switch to "ON" position.
OFF POWER ON
DRAIN
FILL/START
Press and hold down "SANI", "DETERGENT"and "RINSE"
switches to prime chemicals.This step must be repeated
each time chemical containers are changed.
9
STEP
6
STEP
LINE 1
LINE 2
GROUND
GL-X
Quick Setup
Instructions
WARNING: Electrical and
plumbing connections need
to be made by a licensed
service person and comply
with all Federal, State and
Local Health, Electrical,
Plumbing and Safety
codes.
11-2016
Reconnect thermostat wire. Set temperature at
120°F - 140°F.
8
STEP
NOTE: To prevent Heating
Element damage, the GL-X
heater must be filled with
water before the heating
element is energized. For
this reason the Thermostat
has intentionally been
disconnected at the factory
and will require
re-connection.
Hold down "FILL" Switch for approximately 10 - 15 seconds to allow water to flow
into the dishwasher. Water should reach “FILL LINE” which is located inside at the
back of the wash tank. Close door, then press “START” switch.
NOTE: The 4th cam of timer assembly has to be adjusted to maintain the same
water level during the cycle.
7
STEP
OFF POWER ON
DRAIN
FILL/START
FILL LINE
The Spirit of Excellence
an Ali Group Company
an Ali Group Company
8
  • Page 1 1
  • Page 2 2

CMA Dishmachines GL-X Quick Setup Instructions

Type
Quick Setup Instructions

CMA Dishmachines GL-X is a commercial-grade dishwasher designed for heavy-duty cleaning of dishes, glassware, and utensils in restaurants, hotels, and other foodservice establishments. It features a 1/2" water inlet, leveling legs for stability, and a drain hose that can be connected to a wall or floor drain. The GL-X requires a dedicated circuit breaker and should be hard-wired by a licensed electrician. It has a temperature display and adjustable thermostat, allowing you to set the desired water temperature for optimal cleaning results.