Legrand Power Strip Module, Full Width, IS-0084 Installation guide

Type
Installation guide
1. Introduction
The OnQ Power Strip Module is for supplying 120 VAC to OnQ Service Center Enclosures. Figure 1 shows the
Power Strip Module. The Power Strip meets UL requirements of UL 1363, Standard for Relocatable Power
Taps, reference File Number E213024. The Power Strip Module can be mounted in OnQ Service Center
Enclosures.
2. Description
The OnQ Power Strip Module has four power outlets. The outlets are vertically mounted to allow room for OnQ
power modules. It comes with a lighted on/off switch for visual confirmation of power. The power strip is a full
width module.
A. Mounting in Enclosure - Figure 2
1) Align tabs on the modules with slots in
enclosure.
2) Insert tabs by angling module away from the
back of enclosure.
3) Rotate the module and insert fasteners on
module into corresponding holes on rail of
enclosure. (Plunger must be in a pulled position
for fastener to engage hole.)
4) Push plunger in to lock module in place. Pull on
module to ensure module is locked properly in
place.
B. Applying Power
1) Plug power strip into standard 120 VAC outlet.
It is most convenient to have a UL approved
outlet installed in the bottom of the enclosure.
2) Turn on power switch and install power
modules.
NOTE: Outlet must be installed per local electric code.
OnQ Technologies, Inc.
P.O. Box 60907
Harrisburg, PA 17106-0907
800-321-2343
www.onqtech.com
Installation/Instruction Sheet
OnQ Power Strip
IS-0084 Rev. O
IS-0084 Rev. O Page 1 of 1
Ref. P/N 363605-84
Figure 1 - 364266-01
Figure 2