Ada Phone Suite Installation guide

Category
Musical Equipment
Type
Installation guide

Ada Phone Suite is a convenient way to integrate a standard telephone line into the paging circuitry of ADA's multi-room systems. Here are some of its capabilities:

  • Paging: Page individual rooms or pre-programmed paging groups. System-wide paging is also possible.
  • Automatic System Muting: Mutes music in designated rooms when you receive an incoming call or take the phone off the hook.
  • Place Incoming Calls on Hold: Put callers on hold while paging, even if your telephone system doesn't have a hold feature.
  • Provides Internal Dial Tone: Generates a distinctive dial tone to indicate communication with the multi-room system.

Ada Phone Suite is a convenient way to integrate a standard telephone line into the paging circuitry of ADA's multi-room systems. Here are some of its capabilities:

  • Paging: Page individual rooms or pre-programmed paging groups. System-wide paging is also possible.
  • Automatic System Muting: Mutes music in designated rooms when you receive an incoming call or take the phone off the hook.
  • Place Incoming Calls on Hold: Put callers on hold while paging, even if your telephone system doesn't have a hold feature.
  • Provides Internal Dial Tone: Generates a distinctive dial tone to indicate communication with the multi-room system.
Phone Suite Installation Manual
www.ada-usa.com 1
P h o n e S u i t e
I n s t a l l a t i o n M a n u a l
2
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 3
Table of Contents
Phone Suite Diagram ---------------------------------------------------------------------------------- 3
Introduction------------------------------------------------------------------------------------------------ 6
Technical Support---------------------------------------------------------------------------------------- 7
Making Connections ADA Phone Suite ------------------------------------------------------------ 7
Connecting Your Incoming Telephone Line to the Phone Suite ------------------------------ 7
Connecting One of Your Telephones to the Phone Suite -------------------------------------- 7
ADA Bus® Connection --------------------------------------------------------------------------------- 7
Terminating Bus Wire with a Four Pin Connector to Make an ADA Bus Cable ---------- 8
Connecting the ADA Bus of the Phone Suite to the WH-2000 Wiring Harness---------- 8
Jumper Settings on the ADA Phone Suite--------------------------------------------------------- 9
Controls and Adjustments of the Phone Suite---------------------------------------------------- 10
Phone Suite Indicators --------------------------------------------------------------------------------- 11
Operating the Multi-Room System with the Phone Suite Installed -------------------------- 11
Setting the Primary Zone ------------------------------------------------------------------------------ 11
To Set the Zone for Control by the Phone Suite ------------------------------------------------- 11
Broadcasting Pages with a Touch Tone Telephone---------------------------------------------- 12
Making a System Wide Page ------------------------------------------------------------------------- 12
Paging a Specic Zone--------------------------------------------------------------------------------- 12
Paging Groups 1-6 -------------------------------------------------------------------------------------- 12
Music Control Keypad Emulation -------------------------------------------------------------------- 13
Control of Zone Muting Functions ------------------------------------------------------------------- 13
ASCII Codes and Quick Reference Guide -------------------------------------------------------- 14
Audio Design Associates 602-610 Mamaroneck Ave. White Plains, New York 10605 (800) HD-AUDIO (432-8346)
2
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 3
12VAC
500mA
LINE
IN
RING
SENSE
POWER
Bus XMIT
ADA
Bus
®
HOOK SENSE
LINE
EMULATION
NETWORK
BA
UD RATE
OFF ON
ON
OFF
NORM
LEVEL
TONE
19.2K
1200
HOLD
ON/OFF
LEVELS
PHONE
PAGE
MIX
IN
4
3
2
1
1 2 3 4 5 6
G
N
D
+
-
IN
G
N
D
+
-
OUT
AUDIO I/O
600
PHONE
OUT
Telephone Line Input
Connect Standard Phone Line
Phone Page Level Control
Adjusts the audio level from
the telephone system
into the paging input.
Tone Level Trimpot
Sets level to DTMF decoder
Increase level if Phone Suite
doesn't respond when pressing
buttons on the telephone
Line Emulation Jumper
When set to on position an inside
line is immediately established when
phone or spare line is activated
Hold On Jumper
Makes outside line busy when
inside line is active. Hold off setting lea
ves outside
line unchanged when inside line is active.
Baud Rate Jumper
Sets baud rate to match the system's baud rate
ADA bus connection Typically connected to
WH-2000 Wiring Harness
Transmission Indicator
flashes during bus communication
Hook Sense Indicator
lights when inside line is active
Audio Output Connection
Connect to Suite 16 or Suite 8 x 8 Paging Input
External 12 Vac Supply
Connect after making telephone
and line input connections
Telephone Line Output
Connect to primary telephone
to be used for paging
External Paging Level Mix Control
Set to match external audio source
with telephone system
Ring Sense Indicator
Flashes when phone rings
Audio Input Connection
Connect external source to input
ADA Phone Suite Connections, Settings, and Indicators
4
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 5
12VAC
500mA
LINE
IN
RING
SENSE
POWER
Bus XMIT
ADA
Bus
®
HOOK SENSE
LINE
EMULATION
NETWORK
BAUD RATE
OFF ON
ON
OFF
NORM
LEVEL
TONE
19.2K
1200
HOLD
ON/OFF
LEVELS
PHONE
PAGE
MIX
IN
4
3
2
1
1 2 3 4 5 6
G
N
D
+
-
IN
G
N
D
+
-
OUT
AUDIO I/O
600
PHONE
OUT
ADA Phone Suite Incoming Line, Telephone and ADA Bus Connections
WH-2000
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Standard Incoming
Phone Line
Connection to Standard
Touch Tone Telephone or
Spare Line of Phone System
Line
L
R
3
Tx
2
Rx
4
+15V
1
Gnd
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
+12VDC
Triggers
Gnd
In
8
Balanced
Replace
With Same
Value Fuse
Paging
Input/Trigger
Audio Page
Input (600
)
Trigge
r
5-24V
AC
DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1
In
2
TO DB-9 OR PTM 1225/1260
100 Watts Max Power
3/4 ASB
115V-
3/8 ASB
230V-
In
5
In
6
In
7
In
4
In 3
+12VDC
Triggers
Gnd
In 8
In 1
In 2
In 5
In
6
In
7
In
4
In 3
Suite 8
x
8
1 2 3 4
12VAC
500mA
LINE
IN
RING
SENSE
POWER
Bus XMIT
ADA
Bus
®
HOOK SENSE
LINE
EMULATION
NETWORK
BAUD RATE
OFF ON
ON
OFF
NORM
LEVEL
TONE
19.2K
1200
HOLD
ON/OFF
LEVELS
PHONE
PAGE
MIX
IN
4
3
2
1
1 2 3 4 5 6
G
N
D
+
-
IN
G
N
D
+
-
OUT
AUDIO I/O
600
PHONE
OUT
ADA Phone Suite Telephone, Audio Input, and Output Connections
Auxiliary Audio
Output Source
Secondary Audio Source Such as
Line Level Audio or Doorbell
Output (600)
1
Com
2
(+)
3
(-)
Connection to Standard
Touch Tone Telephone or
Spare Line of Phone System
Note Line Emulation Jumper
in the On Position
Line
L
R
3
Tx
2
Rx
4
+15V
1
Gnd
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
+12VDC
Triggers
Gnd
In
8
Balanced
Replace
With Same
Value Fuse
Paging
Input/Trigger
Audio Page
Input (600
)
Trigge
r
5-24V
AC
DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1
In
2
TO DB-9 OR PTM 1225/1260
100 Watts Max Power
3/4 ASB
115V-
3/8 ASB
230V-
In
5
In
6
In
7
In
4
In 3
+12VDC
Triggers
Gnd
In
8
In 1
In
2
In
5
In
6
In
7
In
4
In 3
Suite 8
x
8
4
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 5
12VAC
500mA
LINE
IN
RING
SENSE
POWER
Bus XMIT
ADA
Bus
®
HOOK SENSE
LINE
EMULATION
NETWORK
BAUD RATE
OFF ON
ON
OFF
NORM
LEVEL
TONE
19.2K
1200
HOLD
ON/OFF
LEVELS
PHONE
PAGE
MIX
IN
4
3
2
1
1 2 3 4 5 6
G
N
D
+
-
IN
G
N
D
+
-
OUT
AUDIO I/O
600
PHONE
OUT
ADA Phone Suite Telephone, Audio Input, and Output Connections
Auxiliary Audio
Output Source
Secondary Audio Source Such as
Line Level Audio or Doorbell
Output (600)
1
Com
2
(+)
3
(-)
Connection to Standard
Touch Tone Telephone or
Spare Line of Phone System
Note Line Emulation Jumper
in the On Position
Line
L
R
3
Tx
2
Rx
4
+15V
1
Gnd
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
+12VDC
Triggers
Gnd
In
8
Balanced
Replace
With Same
Value Fuse
Paging
Input/Trigger
Audio Page
Input (600
)
Trigge
r
5-24V
AC
DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1
In
2
TO DB-9 OR PTM 1225/1260
100 Watts Max Power
3/4 ASB
115V-
3/8 ASB
230V-
In
5
In
6
In
7
In
4
In 3
+12VDC
Triggers
Gnd
In
8
In 1
In
2
In
5
In
6
In
7
In
4
In 3
Suite 8
x
8
6
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 7
Introduction
The ADA Phone Suite vastly expands the paging capability of the Suite 16 or Suite 8 x 8 multi-room
system. The Phone Suite provides a convenient way to interface a standard telephone line into the
paging circuitry of ADAs multi-room systems. It is very easy to install and operates seamlessly with
most phone systems. The Phone Suite also lets you use any touch-tone phone for music control in any
zone in the system.
Paging Features
With the Phone Suite, you can page individual rooms or pre-programmed paging groups. You can also
perform a system wide page from any phone in the house. All paging functions can be performed with
any standard touch-tone telephone.
Automatic System Muting
The Phone Suite automatically mutes the music in designated room whenever you receive an incoming
call or the phone is taken off the hook. The system reverts to normal operation at the last volume level
ve seconds after the phone call has ended.
Place Incoming Calls On Hold
The Phone Suite allows you to place callers on hold while performing a page even if your telephone
system does not have a hold feature. You can also program the Phone Suite to keep the line busy while
making pages.
Provides Internal Dial Tone
The Phone Suite generates its own distinctive dial tone to let you know you are communicating with
the multi-room system. The line emulation feature even lets you control the paging functions with any
touch-tone phone completely independent of the main telephone system.
Music Control with any Telephone
The Phone Suite converts any touch-tone telephone into a music control keypad. You can perform the
following commands in any zone: Source Selection, Zone off and Volume Control.
Auxiliary Line Input
A separate balanced line input connector allows you to add an auxiliary line level source for system paging
such as a microphone or door chime. There is also a mixing level control for the auxiliary source.
Status Indicators
Several indicators on the Phone Suite let you know when there is an incoming call, if the phone is off
the hook or when there is communication between the Phone Suite and the ADA Bus.
6
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 7
Keeping Records for Future Reference
Record the serial number located on the back of your amplier in the section below. Also note your dealer’s
name, phone number, and date of purchase. We recommend that you keep your purchase receipt with this
manual you may need to refer to this information in the future.
Serial #: ______________________________ ADA Dealer: ___________________________
Phone Number________________________ Date of Purchase: ________________________
Technical Support
At Audio Design Associates, we realize that our dealer network is the best in the industry. We believe that
it is our responsibility to offer complete technical support for designing, installing, and conguring all our
products. ADA offers an unprecedented coast-to-coast support staff. You can contact us at any time during
the following hours:
Toll Free EST Hours 8:30AM-5:30PM EST (5:30 AM to 2:30 PM PST) Call: 1-800 HD-AUDIO
Toll Free PST Hours 8:30AM-5:30PM PST (11:30AM to 8:30PM EST) Call: 1-877-912-4232
ADAs expanded technical support hours allow our dealer network to contact us up to twelve hours
per day Monday through Friday for personalized service. You can also send us an email anytime to
TechnicalSupport@ADA-USA.com and we will do our best to answer your email as soon as possible,
even after those hours.
Making Connections ADA Phone Suite
Connecting Your Incoming Telephone Line to the Phone Suite
The ADA Phone Suite is designed for use with any standard telephone line or telephone system. Use a
standard telephone cable terminated with an RJ-11 connector from your incoming telephone line into the
Line In connector on the Phone Suite. In the Line Emulation mode, it is not required to connect a phone
line into the Line In Jack.
Connecting One of Your Telephones to the Phone Suite
Connect a telephone to the RJ-11 Line Out connection of the Phone Suite in order to have access to all
the functions and capabilities of the unit.
ADA Bus® Connection
The ADA Bus® allows the Phone Suite to communicate with the Suite 16 or Suite 8 x 8 in order to control
its paging functions.
Shielded three-conductor 18 AWG wire is utilized to make all ADA bus connections for the Suite 16 and
Suite 8 x 8. The pin conguration is as follows:
Pin 1=Ground Pin 2=Feedback Terminal (TX)
Pin 3=Control Terminal (RX) Pin 4= +15-24 Vdc supply voltage.
8
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 9
Terminating Bus Wire with a Four Pin Connector to Make an ADA Bus Cable
ADA Bus cable is used for all bus components such as the Phone Suite, ISO-CAT, CMB-1 system clock,
etc. These components are usually terminated at the WH-2000 wiring harness.
1. Cut a section of shielded three-conductor wire to the desired length for each ADA Bus cable you want
to terminate.
2. Strip the outer jacket to expose the shield and three separate conductors.
3. For each of the three conductors in the shielded wire, strip just enough insulation from the wire to
expose 1/4” of bare wire to t into the connector.
4. Unravel the shield and prepare it as a separate conductor by twisting it tightly clockwise.
5. Loosen each of the four set screws on each connector with a small at blade screwdriver (1/8” wide)
enough to insert the stripped bare speaker wire.
6. Before inserting the wire into the connector, twist all its strands tightly to prevent strays that could
cause a short circuit.
7. Follow the pin conguration listed above, but always use the shield for the ground (pin 1).
8. Insert the stripped bare wire into the connector and tighten the set screws rmly into the place with a
small at blade screwdriver. Do not over tighten.
Connecting the ADA Bus of the Phone Suite to the WH-2000 Wiring Harness
Once you have terminated an ADA Bus cable with the screw type terminals, connect one end of the cable
to the Phone Suite and the other end to one of the fuse protected ADA Bus connectors on the WH-2000:
1 ( J4), 2 ( J3), and 3 ( J2). If necessary, you can also use the LOOP OUT connector on the WH-2000 for
a fourth ADA Bus component but be aware it is not fuse protected.
Connecting the Output of the Phone Suite to the Multi-room System's Paging Input
Terminate the 600 ohm balanced output of the Phone Suite to the 600 ohm paging input of the Suite
16 or Suite 8 x 8 with a two conductor shielded microphone cable. The output terminals of the Phone
Suite connect to the Paging input of the Suite 16 or Suite 8 x 8 as follows:
Phone Suite Out Terminal Suite 16 and Suite 8 x8 Paging Input Terminal
Ground (Terminal 4) Ground (Terminal 1)
Positive (Terminal 5) Positive (Terminal 2)
Negative (Terminal 6) Negative (Terminal 3)
If you experience hum through the paging input with the termination described above, you can try connecting
the Phone Suite using the positive (+) and negative (-) terminals only.
8
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 9
Connecting an Additional Line Level Paging Source to the Phone Suite
If desired, you can connect a secondary line level source to the Audio Input of the Phone Suite. This
gives you an additional source to activate the paging circuitry such as a doorbell or other line level source.
Terminate the 600 ohm balanced output secondary paging source to the 600 ohm paging input of the
Suite 16 or Suite 8 x 8 with a two conductor shielded microphone cable. The output terminals of the
Phone Suite connect to the Paging input of the Suite 16 or Suite 8 x 8 as follows:
Phone Suite Out Terminal
Ground (Terminal 1)
Positive (Terminal 2)
Negative (Terminal 3)
If you experience hum through the paging input or if you are using an unbalanced paging source, connect
the signal across the positive (+) and negative (-) terminals only.
Connecting the Provided 12 VAC 500 mA Power Supply to the Phone Suite
Once you have made all the other connections to the Phone Suite, plug the barrel connector of the
external power supply to the Phone Suite and then plug in into the wall. The power LED will light
when the Phone Suite is powered on.
Jumper Settings on the ADA Phone Suite
Depending on the application of the ADA Phone Suite, you will need to properly position the three
jumpers as described below:
Baud Rate Jumper
The Suite 16 and Suite 8 x 8 leave the factory with an internal baud rate of 19,200 bps. However, some
systems may require a baud rated setting of 1,200. Be sure that the baud rate setting of the Phone Suite
matches the baud rate of the Suite 16 or Suite 8 x 8. The jumper is labeled for 1,200 and 19,200 bps.
Place the jumper in the upper position for 19,200 bps and place the jumper in the lower position for
1,200 bps.
Line Emulation Mode
The Line Emulator jumper sets the emulate mode for the Phone Suite so when any phone or spare line
in the phone system will immediately receive a distinctive tone for an “inside line” to directly control
the Phone Suite's functions.when the phone is picked up. When the Line Emulator jumper is set to
the on position, the Phone Suite operates independently of the rest of the phone system and the hold
feature of the Phone Suite is defeated. However, the ring mute and off hook mute features are still
functional. When in the line emulation mode, you do not need to press the pound (#) key to establish
an inside dial tone. All you need to do is pick up the phone. You cannot get an outside line when the
Phone Suite is set to the line emulation mode.
10
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 11
Line Emulator Mode Jumper
Set the jumper to the upper On position for Line Emulation mode or set the lower Off position for
Normal mode operation.
Normal Mode
In this mode, any phone or spare line from a phone system will operate normally. To obtain an inside
line for paging control. Press the pound (#) key three times within two seconds or hold continuously
for two seconds to get the inside dial tone.
Hold On/Off Mode Jumper
Set this jumper to the right On position for Hold On mode or set the left Off position for Hold Off
mode operation.
Hold Mode On
When the Hold Mode On jumper is set to the On position the outside line will be busy while the
paging circuitry is being controlled through the Phone Suite. This also allows you to place a caller on
hold while a page is being performed.
Hold Mode Off
When set to the Off position, the outside line will remain unaffected during a page so you can still
receive incoming calls.
Controls and Adjustments of the Phone Suite
Tone Level Adjustment
This control sets the internal level to the DTMF (dual tone multi frequency) decoder. In most cases
the default Norm level setting should be adequate for the Phone Suite to operate properly. However,
depending on the phone system it may be necessary to readjust this level. If the Phone Suite obtains
an inside line reliably when pressing the # key three times within two seconds or holding it for two
seconds, the level is set correctly. If the Phone Suite doesnt respond to commands from the telephone,
try readjusting the Tone Level control.
Phone Page Level Control
This control adjusts the audio level from the telephone system. The default setting should be adequate
in most situations especially since you can adjust the level with the Suite 16 software. However, if your
phone system has too low or high of a signal, you can readjust the level with the Phone Page level
control.
10
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 11
External Level Mix Control
If you have connected an external paging or audio source such as a doorbell, you can adjust the Mix
In level control so the external source matches the level of the telephone system. You can also use
this control to make the external source softer or louder than the telephone system if so desired.
Phone Suite Indicators
Power Indicator
This LED lights when the external 12 Vac supply is connected and plugged into a live AC outlet.
Hook Sense Indicator
This indicator lights up whenever the inside line is active.
Bus XMIT Indicator
This LED ashed whenever any serial communication is taking place on the ADA Bus.
Ring Sense Control
This indicator ashes whenever an incoming call is received at the line in connection of the Phone
Suite.
Operating the Multi-Room System with the Phone Suite Installed
Setting the Primary Zone
When rst setting up the Phone Suite for use with the Suite 16 or Suite 8 x 8 system, you need to
let the system know what zone the primary telephone is in. This allows the music to be muted in the
room when the phone rings or when the phone is picked up. It also mutes the page in the specied
room to prevent feedback. Finally, when congured for a specied room, the music control feature
allows you to control the zone with the telephone.
You can also defeat the room specic features of the Phone Suite by assigning the Phone Suite to
room 00. If you set it for non-room specic operation, music control, ring mute, off hook mute,
mute from inside dial tone, and exclude from paging group features are defeated so the phone is
used for paging only.
To Set the Zone for Control by the Phone Suite
1. Pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or
holding it continuously for two seconds.
3. Press the star (*) key and then dial the 2 digit room number from 00-99.
4. You will hear one acknowledgement beep in the receiver then a return to the inside dial tone.
5. Set the zone to 00 if you want to defeat the room specic functions of the Phone Suite and use
the phone for paging only.
12
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 13
Broadcasting Pages with a Touch Tone Telephone
Once you have congured the Phone Suite for use in a specied zone or general paging, you can
broadcast a page system wide, in a specic zone, in one of the paging groups set with the Suite 16
PC control software.
Making a System Wide Page
1. Pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or
holding it continuously for two seconds.
3. If the Line Emulation jumper is set to On, you will get the inside line automatically.
4. Dial 99 to page all zones. An acknowledgement beep will be heard in the receiver after a valid
number is dialed.
5. Make your announcement and hang up the phone when nished.
6. If the phone is left off the hook, the page times out and the system returns to normal after 10
minutes.
Paging a Specic Zone
1. Pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or
holding it continuously for two seconds.
3. If the Line Emulation jumper is set to On, you will get the inside line automatically.
4. Dial 01-90 to page an individual zone. An acknowledgement beep will be heard in the receiver
after a valid number is dialed.
5. Make your announcement and hang up the phone when nished.
6. If the phone is left off the hook, the page times out and the system returns to normal after 10
minutes.
Paging Groups 1-6
1. Pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or
holding it continuously for two seconds.
3. If the Line Emulation jumper is set to On, you will get the inside line automatically.
4. Dial 91-96 to page groups 1-6. An acknowledgement beep will be heard in the receiver after a
valid number is dialed.
5. Make your announcement and hang up the phone when nished.
6. If the phone is left off the hook, the page times out and the system returns to normal after 10
minutes.
Making a Page During an Incoming Phone Call
1. When the phone rings, pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or
holding it continuously for two seconds. This also places the caller on hold.
3. Dial the specic zone or group. An acknowledgement beep will be heard in the receiver after a
valid number is dialed.
5. Press the pound (#) key again to talk to the caller.
6. If the phone is left off the hook, the the system returns to normal after 10 minutes.
12
Audio Design Associates
www.ada-usa.com
Phone Suite Installation Manual
www.ada-usa.com 13
Notes:
If the Line Emulation jumper is set to On, you will get the inside line automatically and will not
be able to talk to the caller.
The zone will remain muted until the call is terminated.
Anytime the inside dial tone is acquired, after 20 seconds of inactivity, the circuit will time out.
Music Control Keypad Emulation
The Phone Suite allows you to use your touch-tone phone to control the system within the zone that
you have congured the Phone Suite to operate in as described above. In the Music Control mode, the
touch-tone phone emulates many of the functions of an ADA keypad including source selection, zone
or system off and volume up and down.
Controlling the Pre-programmed Zone with a Touch Tone phone
1. Pick up the telephone connected to the Phone Suite.
2. Acquire the inside dial tone and distinctive ring by pressing the pound (#) key three times within
two seconds or holding it continuously for two seconds.
3. If the Line Emulation jumper is set to On, you will get the inside line automatically.
4. Dial 00 to activate the music control mode. An acknowledgement beep will be heard in the receiver
and the zone will un-mute.
5. Choose source inputs 1-9 by pressing the corresponding number.
6. Turn zone off by pressing 0
7. Turn volume up incrementally by pressing the # button
8. Turn volume down incrementally by pressing the * button
9. Holding one of the volume buttons on phones with continuous touch-tone output will cause the
volume to ramp up or down.
Control of Zone Muting Functions
You can change the zone muting functions when the phone is taken off the hook or there is an incoming
call with simple toggle commands. This allows you to activate or defeat music muting when there is an
incoming call or if the phone is taken off the hook.
Turning Incoming Ring Mute On and Off
1. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or holding
it continuously for two seconds. If the Line Emulation jumper is set to On, you will get the inside
line automatically.
2. Press 97 to toggle Ring Mute on or off. One acknowledgement beep will be heard in the receiver
when ring mute is active. Two acknowledgement beeps will be heard in the receiver when the ring
mute is off.
Turning Incoming Phone Off Hook Mute On and Off
1. Acquire the inside dial tone by pressing the pound (#) key three times within two seconds or holding
it continuously for two seconds. If the Line Emulation jumper is set to On, you will get the inside
line automatically.
2. Press 98 to toggle Phone Off Hook mute on or off. One acknowledgement beep will be heard in
the receiver when ring mute is active. Two acknowledgement beeps will be heard in the receiver
when the ring mute is off.
ASCII Command Paging Codes
` S PDON G## Page Direct
` S P1ON G00 Group 1
` S P2ON G00 Group 2
` S P3ON G00 Group 3
` S P4ON G00 Group 4
` S P5ON G00 Group 5
` S P6ON G00 Group 6
` S PGOF G00 Page Off
Quick Reference Commands
TO OBTAIN INSIDE DIAL TONE:
PRESS THE # THREE TIMES WITHIN
TWO SECONDS OR HOLD # FOR TWO SECONDS
PAGING SPECIFIC ZONES
PRESS 01-90
SYSTEM WIDE PAGE
PRESS 99
PAGE GROUPS
PRESS 91-96
MUSIC CONTROL
PRESS 00
SOURCES PRESS 1-9
ZONE OFF PRESS 0
VOL UP PRESS #
VOL DOWN PRESS *
CHANGE ZONE
PRESS * THEN 00-99
RING MUTE TOGGLE
PRESS 97
OFF-HOOK MUTE TOGGLE
PRESS 98
Clip out and locate near phone
Quick Reference Commands
TO OBTAIN INSIDE DIAL TONE:
PRESS THE # THREE TIMES WITHIN
TWO SECONDS OR HOLD # FOR TWO SECONDS
PAGING SPECIFIC ZONES
PRESS 01-90
SYSTEM WIDE PAGE
PRESS 99
PAGE GROUPS
PRESS 91-96
MUSIC CONTROL
PRESS 00
SOURCES PRESS 1-9
ZONE OFF PRESS 0
VOL UP PRESS #
VOL DOWN PRESS *
CHANGE ZONE
PRESS * THEN 00-99
RING MUTE TOGGLE
PRESS 97
OFF-HOOK MUTE TOGGLE
PRESS 98
Clip out and locate near phone
Copyright 2003- Audio Design Associates-Revision 1.0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Ada Phone Suite Installation guide

Category
Musical Equipment
Type
Installation guide

Ada Phone Suite is a convenient way to integrate a standard telephone line into the paging circuitry of ADA's multi-room systems. Here are some of its capabilities:

  • Paging: Page individual rooms or pre-programmed paging groups. System-wide paging is also possible.
  • Automatic System Muting: Mutes music in designated rooms when you receive an incoming call or take the phone off the hook.
  • Place Incoming Calls on Hold: Put callers on hold while paging, even if your telephone system doesn't have a hold feature.
  • Provides Internal Dial Tone: Generates a distinctive dial tone to indicate communication with the multi-room system.