Titan Controls Saturn 2 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Titan Controls Saturn 2 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Saturn 2
Day/Night Temperature, Humidity
& CO2 Integration Controller
Instruction Manual
www.titancontrols.net
www.titancontrols.net
Notes:
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
________________________________________________
1 Square = ____ Foot/Feet
®
VANCOUVER, WASHINGTON U.S.A.
VANCOUVER, WASHINGTON U.S.A.
Revision C – 4/23/2012 © Titan Controls®
Saturn 2
• Warnings&Cautions
• Saturn 2- Day/Night Temperature, Humidity & CO2 Integration Controller Overview
• InstructionsforOperation
• TroubleshootingTips
• ControllerSpecications
• InstallationExample
• WarrantyInformation
•ServiceandRepairProgram
Warnings & Cautions
• Readallinstructionsbeforeoperatingcontroller.
• Donotputyourcontrollerinanareawhereitcangetwetorsprayed.
• Mountyourcontrollersecurelytothewallusinghardwareprovided.
• Whenusing“bugbombs”inarea,covercontrollercompletelytoavoidcorrosion.
• Therearenoserviceablepartsincontroller.Donotattempttorepairtheunit.
• Breakingtamperproofsealwillvoidyourwarranty.
• Donotputpaperclips,tools,etc.intounit.Possibleelectrocutionmayoccur.
• Plugcontrollerintosurgeprotectortoavoidpotentialdamagetotheunit.
• Conrmthatyourpowersourceis120Volts/15Ampspriortopluggingcontrollerintooutlet.
• Checkthatallequipmentthatwillbeactivatedbythiscontrolleristhepropervoltage(s).
• Verifythattheequipmentyouarecontrollingdoesnotexceedatotalof15amps.
• Thiscontrollerisdesignedfor“insideuse”only.
• AvoidplacingthecontrollernearheatgeneratingsourcessuchasaCO2Generatororheater.
• Usecautionifoperatingcontrollerinextremelyhumidenvironments(90%andabove).
• Donotusecontrollerforpurposesotherthantheunitwasdesignedtofunction
• Usecontrollerwithindenedenvironmentalspecications.
• AskyourDealerfortipsandtechniquesregardingtheuseofthiscontroller.
• Beconscientiouswhendisposingofanyproducts.
• EnjoyyourTitanControlsenvironmentalcontrollerforyearstocome!
Saturn 2 Day/Night Temperature,
Humidity & CO2 Integration Controller Overview
TheSaturn2isintendedforuseinmaintainingthetemperature,humidityandtoprovideCO2
inyourgrowingenvironment.Boththetemperatureandhumiditycanbeadjustedbysetting
thedialsonthefrontofthecontrollertoyourpreferredsettings.Duringthedaytimehoursthe
WARRANTY SERVICE: Please read warranty information first
Ifafterreviewingthetroubleshootingtipstheunitwillstillnotwork,youshouldreturnittothe
Dealerwhereyoupurchasedit.Theymaybeabletofurtherevaluatetheunitandtestitsvarious
componentsandquitepossiblywillbeabletoidentifyand/orxanyproblems.IftheDealeris
unabletoxtheunit,theywillreturnittousforfactoryrepair.
IftherearenoDealersinyourarea,youmaycontactusdirectlyfortechnicalsupport.Ifwe
cannothelpyouresolvetheproblemoverthephone,wewillissueyouaReturnMerchandise
Authorization(RMA)numberauthorizingyoutoreturntheunittousforfactoryreconditioning
(ifthecontrolleriscurrentlyunderwarranty).ContactthenumberbelowforaRMAnumberand
shippingaddress.Pleasecompletetheformbelowandincludeitwithyourunit,andwritethe
RMAnumberclearlyontheoutsideofthebox.
Pleasepackagetheunitinitsoriginalpackaging.Ifitisdamagedinshipmentwecannotbeheld
responsible.Insuringtheparcelisrecommended.
Oncewereceivetheunitback,wewillrepairitwithin48hours(business)andreturnittoyou
freightprepaidviaUPSgroundshipment.
IncludethefollowingifreturningdirectlytoTitanControls®
•Proofofpurchase•Thiscompletedform•RMA#ontheoutsideofthebox
ReturnMerchandiseAuthorizationNumber(Required)____________________________________________
Dealer/Customer’sName:___________________________________________________________________________
Dealer/Customer’sContactName:___________________________________________________________________
ShippingAddress:___________________________________________________________________________________
_____________________________________________________________________________________________________
Phone#:____________________________________________________________________________________________
Emailaddress:_______________________________________________________________________________
What is the nature of the problem? Please provide as much information as possible. ________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
Sendtoyournearestlocation–shippingaddresswillbegivenwhentheRMA#isissued.
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
®
CUT HERE
controllerleavesthe‘CO2OUTLET’activeuntilthetemperaturesetpointisexceeded.When
thisoccurs,the‘CO2OUTLET’isdeactivatedandthenthe‘FANOUTLET’isactivated;and
yourexhaustfanwillrununtilthetemperatureislowerthanyourpreferredsetting.After
thetemperaturehasloweredbelowtheselectedtemperaturelevelthe‘FANOUTLET’is
defeatedandthe‘CO2OUTLET’isactivatedandcanbegindosingyourgardenwithCO2
again,ifrequired.Thisinnovativefunctionservestwopurposes:One,thisallowsmaximum
CO2coveragewithminimumCO2waste;Two,yourexhaustfanisworkingonlywhenitis
required-savingpowerandwear&tearonyourgear.Atanytimeifthehumiditysetpointis
exceeded,thecontrollerwillactivatethe‘HUMIDITYOUTLET’andreducethehumiditylevel
tobelowyourpreferredhumiditysetting.Duringthenighttimehoursthecontrollerdefeats
the‘CO2OUTLET’(NoneedforCO2atnight)andactivatesthe‘NIGHTOUTLET’.The
‘NIGHTOUTLET’maybeusedtooperateacirculationfan,CO2exhaustfanusingashort
cycletimer,gardenmaintenancenightlightoranyotherdevicethatyouwouldlikeonlyto
runduringthenighttimehours.Ifduringthenighttimehoursthetemperatureexceedsyour
preferredsetting,thenthe‘FANOUTLET’isactivatedtolowerthetemperaturetodesired
levels.Ifthehumiditysetpointisexceededduringthenighttimehours,thenthe‘HUMIDITY
OUTLET”isactivatedandwilllowerthegardenshumiditytodesiredlevels.Thisprovides
thegrowerwith24hourtemperatureandhumiditycontrol.TheSaturn2isbuiltwiththe
highestqualitycomponentstoprovidetheuserwithyearsoftroublefreeservice.Controllers
createdforourindustry,byourindustry!
Instructions for Operation
• SecurelymountyourSaturn2inyourgrowareaandawayfromanymoisture,spray,
pesticides,etc.usingthemountingbracketsandhardwareprovided.
• Plugtheexhaustfanintothe‘FANOUTLET’.
• Turnthefan‘ON’tothehighestsettingpossible,ifadjustable.
• PlugtheCO2Controller(Atlas®SeriesCO2Controller)orarepeatcycletimer(Apollo
seriestimers)intothe“CO2OUTLET’.Then,plugyourCO2GeneratororCO2Regulator/
TankintotheCO2controllerorrepeatcycletimer(SeeInstallationExamplesectionfor
moreinformation)
• TheintegratedphotocellensuresthattheCO2generatororCO2tankonlyactivatewhen
yourgardenisinthedaytimehours(lightsare‘ON’).ThisiswhenyourplantsuptakeCO2
andcangainthemostbenetsfromenrichingtheenvironmentwithCO2.Topreserve
yourCO2,the‘CO2OUTLET’isautomaticallydisabledwhenyour‘FANOUTLET’isactive
orinyourgarden’snighttimehours.
• Whenthe‘CO2OUTLET’isdisabledduringdaytimehoursbecauseofexcessive
temperature,theventilationprocessbeginsandcontinuesuntilthetemperaturelevelhas
loweredtobelowyourpreferredsettingonthetemperaturedial.Afterthetemperature
dropstobelowthepreferredtemperaturesetting,thenthe‘CO2OUTLET’isreactivated
andresumesnormalfunctioning.
• Plugyourcirculationfan,shortcycletimerforCO2exhaustfan,orgardenmaintenance
nightlightintothe“NIGHTOUTLET’.
• Plugthedehumidierintothe‘HUMIDITYOUTLET’
• Turnthedehumidier‘ON’tothelowestsetting.Thisallowsthecontrollertomaintain
precisecontrolofthehumidityinyourgarden.
• Setthe‘Temperature’and‘Humidity’dialsatthepreferredtemperatureandhumidity
levelsforyourgarden.
Warranty Information
•TitanControls®warrantstheoriginalpurchaseofthisproductagainstdefectsinmaterial
andworkmanshipundernormaluseforthree(3)yearsfromthedateofpurchase.
•Duringthewarrantyperiod,TitanControls®will,atouroption,andwithoutcharge,repairor
replacethisproductifthecontrolleroranyofitscomponentsfailormalfunction.
•AllreturnsorrepairsmustbeaccompaniedbyaReturnMerchandiseAuthorization(RMA)
numberpriortoanyserviceoftheproduct.
•Thiswarrantyisinlieuofallotherwarranties,expressedorimplied,includingthewarranties
ofmerchantabilityandtnessforuse,andofallotherobligationsorliabilitiesonthepartof
theseller.
•Thiswarrantyshallnotapplytothisproductoranypartthereofwhichhadbeendamaged
byaccident,abuse,misuse,modication,negligence,alterationormisapplication.
•Controllerswithserialnumbersordatetagsthathavebeenremoved,alteredorobliterated;
brokensealsthatshowevidenceoftampering;mismatchedboardserialnumbersor
nonconformingparts,areexcludedfromcoverage.
•TitanControls®makesnowarrantywhatsoeverinrespecttoaccessoriesorpartsnot
suppliedbyTitanControls®.
•Monetaryrefundsofthewarrantywillnotbegiven.
•TheBuyerassumesallresponsibilityregardingtheproperuse&installationofthis
controller.
•AllwarrantyserviceisprovidedthroughtheTitanControls®factory.
•ThiswarrantyshallapplyonlytotheUnitedStates,includingAlaska,Hawaiiandterritories
oftheUnitedStates.
•Defectivecontrollersarerequiredtobereturnedwiththe“proofofpurchase/receipt”for
warrantycoverage.
•Foradditionalwarrantyinformation,contacttheTitanControls®TechnicalService
RepresentativeoryourlocalDealer.
•NOTE:TitanControls®isaManufacturerofenvironmental,timing,lighting,ventilationand
CO2controls.Allsalesofferingstothepublicaredonethroughanationwidegroupof
Dealers.Nosalesofferingswillbemadedirectlytothegeneralpublic.
Service and Repair Program
• Forallserviceandrepairs,pleasecontactbyourTechnicalServiceRepresentativefor
troubleshootingyourgearandattainingaReturnMerchandiseAuthorization(RMA)number,
ifapplicable.
• Allfactoryservice&repairswillbecompletedwithin48hoursofreceiptofcontrolleratthe
factory.
• TitanControls®will,atitsdiscretion,repairorreplacethecontroller.
• FactorycalibrationservicesareavailableforallTitanControls®.
• ReturningUnits:Pleasecontactyourretailstoreforinformationregardingreturns.
• Finally,plugtheSaturn2intoadedicated120Volt–15Amppowersource.
• UseofasurgeprotectiondeviceisrecommendedtoprotectyourSaturn2frompotential
powerdamageinareaswherethismaybeanissue.
• YourSaturn2willnowcontrolyourequipmentatthedesiredsettings.
Troubleshooting Tips
IftheSaturn2isnotperformingasexpected,trythefollowing:
a.Conrmthatyourpowerinputsourceisactivebyusingavoltagetestmeter,andverifythat
thepowerinputsourceisproviding120VoltsofpowertotheSaturn 2.
b.ValidatethatthepoweroutletsoftheSaturn2areactivebysettingthetemperature
andhumiditydialstothelowestsettings.Thenuseavoltagetestmetertoverifypoweris
owingthroughthecontrollertothepoweroutlets.
c.Ensurethattheexhaustfananddehumidierare‘ON’andsettothelowesttemperature
andhumiditylevels.
d.VerifythattheSaturn2issetatthepropertemperatureandhumiditylevelstoactivate
anddeactivateequipment.
e.Ifyourventilationordehumidicationequipmentdoesnotturnoff,verifythatyourexhaust
fananddehumidierarethecorrectsizeforyourgrowarea.Increasesizeofexhaustfanor
dehumidier(ifnecessary)tocoolanddehumidifythegardenasquicklyaspossible.
f. IfyouarestillhavingproblemswithyourSaturn2,pleasecontactourTechnicalService
Representativeat888-808-4826toassistyoufurther.
Controller Specifications:
• Size=8”Hx6”Wx4”D
• Weight=3lbs.
• InputVoltage=120Volts/AC
• OutputVoltage=120Volts/AC
• MaximumAmperage=15Amps
• OperatingHertz=60Hz
• Minimum/MaximumHumidityControlLevels=20%to80%(non-condensing)
• HumidityAccuracy=±5%ofdesiredsetting
• Minimum/MaximumTemperatureControlLevels=40°to100°F(5°Cto38°C)
• TemperatureAccuracy=±3°Fofdesiredsetting
• Cordset=8feet-14/3SWJ
• StorageTemperature=32°to135°F(0to58°C)
• OperatingTemperature=45°to95°F(7to35°C)
Installation Example
/