Titan Controls Saturn 2 Operating instructions

  • Hello! I've reviewed the Titan Controls Saturn 2 instruction manual and am here to assist you with any questions concerning this device. This manual details usage, troubleshooting, and specifications. It offers guidance on setting up the day/night temperature, humidity, and CO2 integration. Feel free to ask me anything about the controller's features or operation!
  • What is the warranty period for this controller?
    What should I do if my controller is not working properly?
    What is the maximum amperage this controller can handle?
    What is the range of the humidity control?
    What is the range of the temperature control?
Saturn 2
Day/Night Temperature, Humidity
& CO2 Integration Controller
Instruction Manual
www.titancontrols.net
www.titancontrols.net
Notes:
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
________________________________________________
1 Square = ____ Foot/Feet
®
VANCOUVER, WASHINGTON U.S.A.
VANCOUVER, WASHINGTON U.S.A.
Revision C – 4/23/2012 © Titan Controls®
Saturn 2
• Warnings&Cautions
• Saturn 2- Day/Night Temperature, Humidity & CO2 Integration Controller Overview
• InstructionsforOperation
• TroubleshootingTips
• ControllerSpecications
• InstallationExample
• WarrantyInformation
•ServiceandRepairProgram
Warnings & Cautions
• Readallinstructionsbeforeoperatingcontroller.
• Donotputyourcontrollerinanareawhereitcangetwetorsprayed.
• Mountyourcontrollersecurelytothewallusinghardwareprovided.
• Whenusing“bugbombs”inarea,covercontrollercompletelytoavoidcorrosion.
• Therearenoserviceablepartsincontroller.Donotattempttorepairtheunit.
• Breakingtamperproofsealwillvoidyourwarranty.
• Donotputpaperclips,tools,etc.intounit.Possibleelectrocutionmayoccur.
• Plugcontrollerintosurgeprotectortoavoidpotentialdamagetotheunit.
• Conrmthatyourpowersourceis120Volts/15Ampspriortopluggingcontrollerintooutlet.
• Checkthatallequipmentthatwillbeactivatedbythiscontrolleristhepropervoltage(s).
• Verifythattheequipmentyouarecontrollingdoesnotexceedatotalof15amps.
• Thiscontrollerisdesignedfor“insideuse”only.
• AvoidplacingthecontrollernearheatgeneratingsourcessuchasaCO2Generatororheater.
• Usecautionifoperatingcontrollerinextremelyhumidenvironments(90%andabove).
• Donotusecontrollerforpurposesotherthantheunitwasdesignedtofunction
• Usecontrollerwithindenedenvironmentalspecications.
• AskyourDealerfortipsandtechniquesregardingtheuseofthiscontroller.
• Beconscientiouswhendisposingofanyproducts.
• EnjoyyourTitanControlsenvironmentalcontrollerforyearstocome!
Saturn 2 Day/Night Temperature,
Humidity & CO2 Integration Controller Overview
TheSaturn2isintendedforuseinmaintainingthetemperature,humidityandtoprovideCO2
inyourgrowingenvironment.Boththetemperatureandhumiditycanbeadjustedbysetting
thedialsonthefrontofthecontrollertoyourpreferredsettings.Duringthedaytimehoursthe
WARRANTY SERVICE: Please read warranty information first
Ifafterreviewingthetroubleshootingtipstheunitwillstillnotwork,youshouldreturnittothe
Dealerwhereyoupurchasedit.Theymaybeabletofurtherevaluatetheunitandtestitsvarious
componentsandquitepossiblywillbeabletoidentifyand/orxanyproblems.IftheDealeris
unabletoxtheunit,theywillreturnittousforfactoryrepair.
IftherearenoDealersinyourarea,youmaycontactusdirectlyfortechnicalsupport.Ifwe
cannothelpyouresolvetheproblemoverthephone,wewillissueyouaReturnMerchandise
Authorization(RMA)numberauthorizingyoutoreturntheunittousforfactoryreconditioning
(ifthecontrolleriscurrentlyunderwarranty).ContactthenumberbelowforaRMAnumberand
shippingaddress.Pleasecompletetheformbelowandincludeitwithyourunit,andwritethe
RMAnumberclearlyontheoutsideofthebox.
Pleasepackagetheunitinitsoriginalpackaging.Ifitisdamagedinshipmentwecannotbeheld
responsible.Insuringtheparcelisrecommended.
Oncewereceivetheunitback,wewillrepairitwithin48hours(business)andreturnittoyou
freightprepaidviaUPSgroundshipment.
IncludethefollowingifreturningdirectlytoTitanControls®
•Proofofpurchase•Thiscompletedform•RMA#ontheoutsideofthebox
ReturnMerchandiseAuthorizationNumber(Required)____________________________________________
Dealer/Customer’sName:___________________________________________________________________________
Dealer/Customer’sContactName:___________________________________________________________________
ShippingAddress:___________________________________________________________________________________
_____________________________________________________________________________________________________
Phone#:____________________________________________________________________________________________
Emailaddress:_______________________________________________________________________________
What is the nature of the problem? Please provide as much information as possible. ________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
Sendtoyournearestlocation–shippingaddresswillbegivenwhentheRMA#isissued.
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
®
CUT HERE
controllerleavesthe‘CO2OUTLET’activeuntilthetemperaturesetpointisexceeded.When
thisoccurs,the‘CO2OUTLET’isdeactivatedandthenthe‘FANOUTLET’isactivated;and
yourexhaustfanwillrununtilthetemperatureislowerthanyourpreferredsetting.After
thetemperaturehasloweredbelowtheselectedtemperaturelevelthe‘FANOUTLET’is
defeatedandthe‘CO2OUTLET’isactivatedandcanbegindosingyourgardenwithCO2
again,ifrequired.Thisinnovativefunctionservestwopurposes:One,thisallowsmaximum
CO2coveragewithminimumCO2waste;Two,yourexhaustfanisworkingonlywhenitis
required-savingpowerandwear&tearonyourgear.Atanytimeifthehumiditysetpointis
exceeded,thecontrollerwillactivatethe‘HUMIDITYOUTLET’andreducethehumiditylevel
tobelowyourpreferredhumiditysetting.Duringthenighttimehoursthecontrollerdefeats
the‘CO2OUTLET’(NoneedforCO2atnight)andactivatesthe‘NIGHTOUTLET’.The
‘NIGHTOUTLET’maybeusedtooperateacirculationfan,CO2exhaustfanusingashort
cycletimer,gardenmaintenancenightlightoranyotherdevicethatyouwouldlikeonlyto
runduringthenighttimehours.Ifduringthenighttimehoursthetemperatureexceedsyour
preferredsetting,thenthe‘FANOUTLET’isactivatedtolowerthetemperaturetodesired
levels.Ifthehumiditysetpointisexceededduringthenighttimehours,thenthe‘HUMIDITY
OUTLET”isactivatedandwilllowerthegardenshumiditytodesiredlevels.Thisprovides
thegrowerwith24hourtemperatureandhumiditycontrol.TheSaturn2isbuiltwiththe
highestqualitycomponentstoprovidetheuserwithyearsoftroublefreeservice.Controllers
createdforourindustry,byourindustry!
Instructions for Operation
• SecurelymountyourSaturn2inyourgrowareaandawayfromanymoisture,spray,
pesticides,etc.usingthemountingbracketsandhardwareprovided.
• Plugtheexhaustfanintothe‘FANOUTLET’.
• Turnthefan‘ON’tothehighestsettingpossible,ifadjustable.
• PlugtheCO2Controller(Atlas®SeriesCO2Controller)orarepeatcycletimer(Apollo
seriestimers)intothe“CO2OUTLET’.Then,plugyourCO2GeneratororCO2Regulator/
TankintotheCO2controllerorrepeatcycletimer(SeeInstallationExamplesectionfor
moreinformation)
• TheintegratedphotocellensuresthattheCO2generatororCO2tankonlyactivatewhen
yourgardenisinthedaytimehours(lightsare‘ON’).ThisiswhenyourplantsuptakeCO2
andcangainthemostbenetsfromenrichingtheenvironmentwithCO2.Topreserve
yourCO2,the‘CO2OUTLET’isautomaticallydisabledwhenyour‘FANOUTLET’isactive
orinyourgarden’snighttimehours.
• Whenthe‘CO2OUTLET’isdisabledduringdaytimehoursbecauseofexcessive
temperature,theventilationprocessbeginsandcontinuesuntilthetemperaturelevelhas
loweredtobelowyourpreferredsettingonthetemperaturedial.Afterthetemperature
dropstobelowthepreferredtemperaturesetting,thenthe‘CO2OUTLET’isreactivated
andresumesnormalfunctioning.
• Plugyourcirculationfan,shortcycletimerforCO2exhaustfan,orgardenmaintenance
nightlightintothe“NIGHTOUTLET’.
• Plugthedehumidierintothe‘HUMIDITYOUTLET’
• Turnthedehumidier‘ON’tothelowestsetting.Thisallowsthecontrollertomaintain
precisecontrolofthehumidityinyourgarden.
• Setthe‘Temperature’and‘Humidity’dialsatthepreferredtemperatureandhumidity
levelsforyourgarden.
Warranty Information
•TitanControls®warrantstheoriginalpurchaseofthisproductagainstdefectsinmaterial
andworkmanshipundernormaluseforthree(3)yearsfromthedateofpurchase.
•Duringthewarrantyperiod,TitanControls®will,atouroption,andwithoutcharge,repairor
replacethisproductifthecontrolleroranyofitscomponentsfailormalfunction.
•AllreturnsorrepairsmustbeaccompaniedbyaReturnMerchandiseAuthorization(RMA)
numberpriortoanyserviceoftheproduct.
•Thiswarrantyisinlieuofallotherwarranties,expressedorimplied,includingthewarranties
ofmerchantabilityandtnessforuse,andofallotherobligationsorliabilitiesonthepartof
theseller.
•Thiswarrantyshallnotapplytothisproductoranypartthereofwhichhadbeendamaged
byaccident,abuse,misuse,modication,negligence,alterationormisapplication.
•Controllerswithserialnumbersordatetagsthathavebeenremoved,alteredorobliterated;
brokensealsthatshowevidenceoftampering;mismatchedboardserialnumbersor
nonconformingparts,areexcludedfromcoverage.
•TitanControls®makesnowarrantywhatsoeverinrespecttoaccessoriesorpartsnot
suppliedbyTitanControls®.
•Monetaryrefundsofthewarrantywillnotbegiven.
•TheBuyerassumesallresponsibilityregardingtheproperuse&installationofthis
controller.
•AllwarrantyserviceisprovidedthroughtheTitanControls®factory.
•ThiswarrantyshallapplyonlytotheUnitedStates,includingAlaska,Hawaiiandterritories
oftheUnitedStates.
•Defectivecontrollersarerequiredtobereturnedwiththe“proofofpurchase/receipt”for
warrantycoverage.
•Foradditionalwarrantyinformation,contacttheTitanControls®TechnicalService
RepresentativeoryourlocalDealer.
•NOTE:TitanControls®isaManufacturerofenvironmental,timing,lighting,ventilationand
CO2controls.Allsalesofferingstothepublicaredonethroughanationwidegroupof
Dealers.Nosalesofferingswillbemadedirectlytothegeneralpublic.
Service and Repair Program
• Forallserviceandrepairs,pleasecontactbyourTechnicalServiceRepresentativefor
troubleshootingyourgearandattainingaReturnMerchandiseAuthorization(RMA)number,
ifapplicable.
• Allfactoryservice&repairswillbecompletedwithin48hoursofreceiptofcontrolleratthe
factory.
• TitanControls®will,atitsdiscretion,repairorreplacethecontroller.
• FactorycalibrationservicesareavailableforallTitanControls®.
• ReturningUnits:Pleasecontactyourretailstoreforinformationregardingreturns.
• Finally,plugtheSaturn2intoadedicated120Volt–15Amppowersource.
• UseofasurgeprotectiondeviceisrecommendedtoprotectyourSaturn2frompotential
powerdamageinareaswherethismaybeanissue.
• YourSaturn2willnowcontrolyourequipmentatthedesiredsettings.
Troubleshooting Tips
IftheSaturn2isnotperformingasexpected,trythefollowing:
a.Conrmthatyourpowerinputsourceisactivebyusingavoltagetestmeter,andverifythat
thepowerinputsourceisproviding120VoltsofpowertotheSaturn 2.
b.ValidatethatthepoweroutletsoftheSaturn2areactivebysettingthetemperature
andhumiditydialstothelowestsettings.Thenuseavoltagetestmetertoverifypoweris
owingthroughthecontrollertothepoweroutlets.
c.Ensurethattheexhaustfananddehumidierare‘ON’andsettothelowesttemperature
andhumiditylevels.
d.VerifythattheSaturn2issetatthepropertemperatureandhumiditylevelstoactivate
anddeactivateequipment.
e.Ifyourventilationordehumidicationequipmentdoesnotturnoff,verifythatyourexhaust
fananddehumidierarethecorrectsizeforyourgrowarea.Increasesizeofexhaustfanor
dehumidier(ifnecessary)tocoolanddehumidifythegardenasquicklyaspossible.
f. IfyouarestillhavingproblemswithyourSaturn2,pleasecontactourTechnicalService
Representativeat888-808-4826toassistyoufurther.
Controller Specifications:
• Size=8”Hx6”Wx4”D
• Weight=3lbs.
• InputVoltage=120Volts/AC
• OutputVoltage=120Volts/AC
• MaximumAmperage=15Amps
• OperatingHertz=60Hz
• Minimum/MaximumHumidityControlLevels=20%to80%(non-condensing)
• HumidityAccuracy=±5%ofdesiredsetting
• Minimum/MaximumTemperatureControlLevels=40°to100°F(5°Cto38°C)
• TemperatureAccuracy=±3°Fofdesiredsetting
• Cordset=8feet-14/3SWJ
• StorageTemperature=32°to135°F(0to58°C)
• OperatingTemperature=45°to95°F(7to35°C)
Installation Example
/