Titan Controls Saturn 2 is a Day/Night Temperature, Humidity & CO2 Integration Controller that is intended for use in maintaining the temperature, humidity and providing CO2 in your growing environment. Both the temperature and humidity can be adjusted by setting the dials on the front of the controller to your preferred settings. During the daytime hours the controller leaves the ‘CO2 OUTLET’ active until the temperature set point is exceeded.

Titan Controls Saturn 2 is a Day/Night Temperature, Humidity & CO2 Integration Controller that is intended for use in maintaining the temperature, humidity and providing CO2 in your growing environment. Both the temperature and humidity can be adjusted by setting the dials on the front of the controller to your preferred settings. During the daytime hours the controller leaves the ‘CO2 OUTLET’ active until the temperature set point is exceeded.

Saturn 2
Day/Night Temperature, Humidity
& CO2 Integration Controller
Instruction Manual
www.titancontrols.net
www.titancontrols.net
Notes:
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
_________________________________________________
________________________________________________
1 Square = ____ Foot/Feet
®
VANCOUVER, WASHINGTON U.S.A.
VANCOUVER, WASHINGTON U.S.A.
Revision C – 4/23/2012 © Titan Controls®
Saturn 2
• Warnings&Cautions
• Saturn 2- Day/Night Temperature, Humidity & CO2 Integration Controller Overview
• InstructionsforOperation
• TroubleshootingTips
• ControllerSpecications
• InstallationExample
• WarrantyInformation
•ServiceandRepairProgram
Warnings & Cautions
• Readallinstructionsbeforeoperatingcontroller.
• Donotputyourcontrollerinanareawhereitcangetwetorsprayed.
• Mountyourcontrollersecurelytothewallusinghardwareprovided.
• Whenusing“bugbombs”inarea,covercontrollercompletelytoavoidcorrosion.
• Therearenoserviceablepartsincontroller.Donotattempttorepairtheunit.
• Breakingtamperproofsealwillvoidyourwarranty.
• Donotputpaperclips,tools,etc.intounit.Possibleelectrocutionmayoccur.
• Plugcontrollerintosurgeprotectortoavoidpotentialdamagetotheunit.
• Conrmthatyourpowersourceis120Volts/15Ampspriortopluggingcontrollerintooutlet.
• Checkthatallequipmentthatwillbeactivatedbythiscontrolleristhepropervoltage(s).
• Verifythattheequipmentyouarecontrollingdoesnotexceedatotalof15amps.
• Thiscontrollerisdesignedfor“insideuse”only.
• AvoidplacingthecontrollernearheatgeneratingsourcessuchasaCO2Generatororheater.
• Usecautionifoperatingcontrollerinextremelyhumidenvironments(90%andabove).
• Donotusecontrollerforpurposesotherthantheunitwasdesignedtofunction
• Usecontrollerwithindenedenvironmentalspecications.
• AskyourDealerfortipsandtechniquesregardingtheuseofthiscontroller.
• Beconscientiouswhendisposingofanyproducts.
• EnjoyyourTitanControlsenvironmentalcontrollerforyearstocome!
Saturn 2 Day/Night Temperature,
Humidity & CO2 Integration Controller Overview
TheSaturn2isintendedforuseinmaintainingthetemperature,humidityandtoprovideCO2
inyourgrowingenvironment.Boththetemperatureandhumiditycanbeadjustedbysetting
thedialsonthefrontofthecontrollertoyourpreferredsettings.Duringthedaytimehoursthe
WARRANTY SERVICE: Please read warranty information first
Ifafterreviewingthetroubleshootingtipstheunitwillstillnotwork,youshouldreturnittothe
Dealerwhereyoupurchasedit.Theymaybeabletofurtherevaluatetheunitandtestitsvarious
componentsandquitepossiblywillbeabletoidentifyand/orxanyproblems.IftheDealeris
unabletoxtheunit,theywillreturnittousforfactoryrepair.
IftherearenoDealersinyourarea,youmaycontactusdirectlyfortechnicalsupport.Ifwe
cannothelpyouresolvetheproblemoverthephone,wewillissueyouaReturnMerchandise
Authorization(RMA)numberauthorizingyoutoreturntheunittousforfactoryreconditioning
(ifthecontrolleriscurrentlyunderwarranty).ContactthenumberbelowforaRMAnumberand
shippingaddress.Pleasecompletetheformbelowandincludeitwithyourunit,andwritethe
RMAnumberclearlyontheoutsideofthebox.
Pleasepackagetheunitinitsoriginalpackaging.Ifitisdamagedinshipmentwecannotbeheld
responsible.Insuringtheparcelisrecommended.
Oncewereceivetheunitback,wewillrepairitwithin48hours(business)andreturnittoyou
freightprepaidviaUPSgroundshipment.
IncludethefollowingifreturningdirectlytoTitanControls®
•Proofofpurchase•Thiscompletedform•RMA#ontheoutsideofthebox
ReturnMerchandiseAuthorizationNumber(Required)____________________________________________
Dealer/Customer’sName:___________________________________________________________________________
Dealer/Customer’sContactName:___________________________________________________________________
ShippingAddress:___________________________________________________________________________________
_____________________________________________________________________________________________________
Phone#:____________________________________________________________________________________________
Emailaddress:_______________________________________________________________________________
What is the nature of the problem? Please provide as much information as possible. ________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
Sendtoyournearestlocation–shippingaddresswillbegivenwhentheRMA#isissued.
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
®
CUT HERE
controllerleavesthe‘CO2OUTLET’activeuntilthetemperaturesetpointisexceeded.When
thisoccurs,the‘CO2OUTLET’isdeactivatedandthenthe‘FANOUTLET’isactivated;and
yourexhaustfanwillrununtilthetemperatureislowerthanyourpreferredsetting.After
thetemperaturehasloweredbelowtheselectedtemperaturelevelthe‘FANOUTLET’is
defeatedandthe‘CO2OUTLET’isactivatedandcanbegindosingyourgardenwithCO2
again,ifrequired.Thisinnovativefunctionservestwopurposes:One,thisallowsmaximum
CO2coveragewithminimumCO2waste;Two,yourexhaustfanisworkingonlywhenitis
required-savingpowerandwear&tearonyourgear.Atanytimeifthehumiditysetpointis
exceeded,thecontrollerwillactivatethe‘HUMIDITYOUTLET’andreducethehumiditylevel
tobelowyourpreferredhumiditysetting.Duringthenighttimehoursthecontrollerdefeats
the‘CO2OUTLET’(NoneedforCO2atnight)andactivatesthe‘NIGHTOUTLET’.The
‘NIGHTOUTLET’maybeusedtooperateacirculationfan,CO2exhaustfanusingashort
cycletimer,gardenmaintenancenightlightoranyotherdevicethatyouwouldlikeonlyto
runduringthenighttimehours.Ifduringthenighttimehoursthetemperatureexceedsyour
preferredsetting,thenthe‘FANOUTLET’isactivatedtolowerthetemperaturetodesired
levels.Ifthehumiditysetpointisexceededduringthenighttimehours,thenthe‘HUMIDITY
OUTLET”isactivatedandwilllowerthegardenshumiditytodesiredlevels.Thisprovides
thegrowerwith24hourtemperatureandhumiditycontrol.TheSaturn2isbuiltwiththe
highestqualitycomponentstoprovidetheuserwithyearsoftroublefreeservice.Controllers
createdforourindustry,byourindustry!
Instructions for Operation
• SecurelymountyourSaturn2inyourgrowareaandawayfromanymoisture,spray,
pesticides,etc.usingthemountingbracketsandhardwareprovided.
• Plugtheexhaustfanintothe‘FANOUTLET’.
• Turnthefan‘ON’tothehighestsettingpossible,ifadjustable.
• PlugtheCO2Controller(Atlas®SeriesCO2Controller)orarepeatcycletimer(Apollo
seriestimers)intothe“CO2OUTLET’.Then,plugyourCO2GeneratororCO2Regulator/
TankintotheCO2controllerorrepeatcycletimer(SeeInstallationExamplesectionfor
moreinformation)
• TheintegratedphotocellensuresthattheCO2generatororCO2tankonlyactivatewhen
yourgardenisinthedaytimehours(lightsare‘ON’).ThisiswhenyourplantsuptakeCO2
andcangainthemostbenetsfromenrichingtheenvironmentwithCO2.Topreserve
yourCO2,the‘CO2OUTLET’isautomaticallydisabledwhenyour‘FANOUTLET’isactive
orinyourgarden’snighttimehours.
• Whenthe‘CO2OUTLET’isdisabledduringdaytimehoursbecauseofexcessive
temperature,theventilationprocessbeginsandcontinuesuntilthetemperaturelevelhas
loweredtobelowyourpreferredsettingonthetemperaturedial.Afterthetemperature
dropstobelowthepreferredtemperaturesetting,thenthe‘CO2OUTLET’isreactivated
andresumesnormalfunctioning.
• Plugyourcirculationfan,shortcycletimerforCO2exhaustfan,orgardenmaintenance
nightlightintothe“NIGHTOUTLET’.
• Plugthedehumidierintothe‘HUMIDITYOUTLET’
• Turnthedehumidier‘ON’tothelowestsetting.Thisallowsthecontrollertomaintain
precisecontrolofthehumidityinyourgarden.
• Setthe‘Temperature’and‘Humidity’dialsatthepreferredtemperatureandhumidity
levelsforyourgarden.
Warranty Information
•TitanControls®warrantstheoriginalpurchaseofthisproductagainstdefectsinmaterial
andworkmanshipundernormaluseforthree(3)yearsfromthedateofpurchase.
•Duringthewarrantyperiod,TitanControls®will,atouroption,andwithoutcharge,repairor
replacethisproductifthecontrolleroranyofitscomponentsfailormalfunction.
•AllreturnsorrepairsmustbeaccompaniedbyaReturnMerchandiseAuthorization(RMA)
numberpriortoanyserviceoftheproduct.
•Thiswarrantyisinlieuofallotherwarranties,expressedorimplied,includingthewarranties
ofmerchantabilityandtnessforuse,andofallotherobligationsorliabilitiesonthepartof
theseller.
•Thiswarrantyshallnotapplytothisproductoranypartthereofwhichhadbeendamaged
byaccident,abuse,misuse,modication,negligence,alterationormisapplication.
•Controllerswithserialnumbersordatetagsthathavebeenremoved,alteredorobliterated;
brokensealsthatshowevidenceoftampering;mismatchedboardserialnumbersor
nonconformingparts,areexcludedfromcoverage.
•TitanControls®makesnowarrantywhatsoeverinrespecttoaccessoriesorpartsnot
suppliedbyTitanControls®.
•Monetaryrefundsofthewarrantywillnotbegiven.
•TheBuyerassumesallresponsibilityregardingtheproperuse&installationofthis
controller.
•AllwarrantyserviceisprovidedthroughtheTitanControls®factory.
•ThiswarrantyshallapplyonlytotheUnitedStates,includingAlaska,Hawaiiandterritories
oftheUnitedStates.
•Defectivecontrollersarerequiredtobereturnedwiththe“proofofpurchase/receipt”for
warrantycoverage.
•Foradditionalwarrantyinformation,contacttheTitanControls®TechnicalService
RepresentativeoryourlocalDealer.
•NOTE:TitanControls®isaManufacturerofenvironmental,timing,lighting,ventilationand
CO2controls.Allsalesofferingstothepublicaredonethroughanationwidegroupof
Dealers.Nosalesofferingswillbemadedirectlytothegeneralpublic.
Service and Repair Program
• Forallserviceandrepairs,pleasecontactbyourTechnicalServiceRepresentativefor
troubleshootingyourgearandattainingaReturnMerchandiseAuthorization(RMA)number,
ifapplicable.
• Allfactoryservice&repairswillbecompletedwithin48hoursofreceiptofcontrolleratthe
factory.
• TitanControls®will,atitsdiscretion,repairorreplacethecontroller.
• FactorycalibrationservicesareavailableforallTitanControls®.
• ReturningUnits:Pleasecontactyourretailstoreforinformationregardingreturns.
• Finally,plugtheSaturn2intoadedicated120Volt–15Amppowersource.
• UseofasurgeprotectiondeviceisrecommendedtoprotectyourSaturn2frompotential
powerdamageinareaswherethismaybeanissue.
• YourSaturn2willnowcontrolyourequipmentatthedesiredsettings.
Troubleshooting Tips
IftheSaturn2isnotperformingasexpected,trythefollowing:
a.Conrmthatyourpowerinputsourceisactivebyusingavoltagetestmeter,andverifythat
thepowerinputsourceisproviding120VoltsofpowertotheSaturn 2.
b.ValidatethatthepoweroutletsoftheSaturn2areactivebysettingthetemperature
andhumiditydialstothelowestsettings.Thenuseavoltagetestmetertoverifypoweris
owingthroughthecontrollertothepoweroutlets.
c.Ensurethattheexhaustfananddehumidierare‘ON’andsettothelowesttemperature
andhumiditylevels.
d.VerifythattheSaturn2issetatthepropertemperatureandhumiditylevelstoactivate
anddeactivateequipment.
e.Ifyourventilationordehumidicationequipmentdoesnotturnoff,verifythatyourexhaust
fananddehumidierarethecorrectsizeforyourgrowarea.Increasesizeofexhaustfanor
dehumidier(ifnecessary)tocoolanddehumidifythegardenasquicklyaspossible.
f. IfyouarestillhavingproblemswithyourSaturn2,pleasecontactourTechnicalService
Representativeat888-808-4826toassistyoufurther.
Controller Specifications:
• Size=8”Hx6”Wx4”D
• Weight=3lbs.
• InputVoltage=120Volts/AC
• OutputVoltage=120Volts/AC
• MaximumAmperage=15Amps
• OperatingHertz=60Hz
• Minimum/MaximumHumidityControlLevels=20%to80%(non-condensing)
• HumidityAccuracy=±5%ofdesiredsetting
• Minimum/MaximumTemperatureControlLevels=40°to100°F(5°Cto38°C)
• TemperatureAccuracy=±3°Fofdesiredsetting
• Cordset=8feet-14/3SWJ
• StorageTemperature=32°to135°F(0to58°C)
• OperatingTemperature=45°to95°F(7to35°C)
Installation Example
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Titan Controls Saturn 2 Operating instructions

Type
Operating instructions

Titan Controls Saturn 2 is a Day/Night Temperature, Humidity & CO2 Integration Controller that is intended for use in maintaining the temperature, humidity and providing CO2 in your growing environment. Both the temperature and humidity can be adjusted by setting the dials on the front of the controller to your preferred settings. During the daytime hours the controller leaves the ‘CO2 OUTLET’ active until the temperature set point is exceeded.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI