Saturn 1
• Warnings&Cautions
• Saturn1-Temperature&HumidityControllerOverview
• InstructionsforOperation
• TroubleshootingTips
• ControllerSpecications
• InstallationExample
• WarrantyInformation
• ServiceandRepairProgram
Warnings & Cautions
• Readallinstructionsbeforeoperatingcontroller.
• Donotputyourcontrollerinanareawhereitcangetwetorsprayed.
• Mountyourcontrollersecurelytothewallusinghardwareprovided.
• Whenusing“bugbombs”inarea,covercontrollercompletelytoavoidcorrosion.
• Therearenoserviceablepartsincontroller.Donotattempttorepairtheunit.
• Breakingtamperproofsealwillvoidyourwarranty.
• Donotputpaperclips,tools,etc.intounit.Possibleelectrocutionmayoccur.
• Plugcontrollerintosurgeprotectortoavoidpotentialdamagetotheunit.
• Conrmthatyourpowersourceis120Volts/15Ampspriortopluggingcontrollerinto
outlet.
• Checkthatallequipmentthatwillbeactivatedbythiscontrolleristhepropervoltage(s).
• Verifythattheequipmentyouarecontrollingdoesnotexceedatotalof15amps.
• Thiscontrollerisdesignedfor“insideuse”only.
• AvoidplacingthecontrollernearheatgeneratingsourcessuchasaCO2Generatoror
heater.
• Usecautionifoperatingcontrollerinextremelyhumidenvironments(90%andabove).
• Donotusecontrollerforpurposesotherthantheunitwasdesignedtofunction
• Usecontrollerwithindenedenvironmentalspecications.
• AskyourDealerfortipsandtechniquesregardingtheuseofthiscontroller.
• Beconscientiouswhendisposingofanyproducts.
• EnjoyyourTitanControls®environmentalcontrollerforyearstocome!
WARRANTY SERVICE: Please read warranty information first
Ifafterreviewingthetroubleshootingtipstheunitwillstillnotwork,youshouldreturnittothe
Dealerwhereyoupurchasedit.Theymaybeabletofurtherevaluatetheunitandtestitsvarious
componentsandquitepossiblywillbeabletoidentifyand/orxanyproblems.IftheDealeris
unabletoxtheunit,theywillreturnittousforfactoryrepair.
IftherearenoDealersinyourarea,youmaycontactusdirectlyfortechnicalsupport.Ifwe
cannothelpyouresolvetheproblemoverthephone,wewillissueyouaReturnMerchandise
Authorization(RMA)numberauthorizingyoutoreturntheunittousforfactoryreconditioning
(ifthecontrolleriscurrentlyunderwarranty).ContactthenumberbelowforaRMAnumberand
shippingaddress.Pleasecompletetheformbelowandincludeitwithyourunit,andwritethe
RMAnumberclearlyontheoutsideofthebox.
Pleasepackagetheunitinitsoriginalpackaging.Ifitisdamagedinshipmentwecannotbeheld
responsible.Insuringtheparcelisrecommended.
Oncewereceivetheunitback,wewillrepairitwithin48hours(business)andreturnittoyou
freightprepaidviaUPSgroundshipment.
IncludethefollowingifreturningdirectlytoTitanControls®
•Proofofpurchase•Thiscompletedform•RMA#ontheoutsideofthebox
ReturnMerchandiseAuthorizationNumber(Required)____________________________________________
Dealer/Customer’sName:___________________________________________________________________________
Dealer/Customer’sContactName:___________________________________________________________________
ShippingAddress:___________________________________________________________________________________
_____________________________________________________________________________________________________
Phone#:____________________________________________________________________________________________
Emailaddress:_______________________________________________________________________________
What is the nature of the problem? Please provide as much information as possible. ________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
____________________________________________________
Sendtoyournearestlocation–shippingaddresswillbegivenwhentheRMA#isissued.
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
®
CUT HERE
Saturn 1 Temperature &
Humidity Controller Overview
TheSaturn1isusedtoindependentlymaintainthetemperatureandhumiditylevelsin
yourgrowingenvironment.Boththetemperatureandhumiditycanbeadjustedbysetting
thedialsonthefrontofthecontrollertoyourpreferredsettings.Ifthetemperatureexceeds
thepredeterminedsetting,thenthe‘FANOUTLET’isactivatedandwilloperatetheexhaust
fanuntilthetemperatureislowerthanthepreferredsetpoint.Ifthehumidityexceeds
thepredeterminedsetting,thenthe‘HUMIDITYOUTLET’isactivatedandwilloperatethe
dehumidieruntilthehumidityisunderthepreferredsetpoint.Afterthetemperatureor
humidityhasloweredbelowthepreferredtemperatureorhumiditylevels,theequipment
willturnoffandbeonstandbyuntilthenexttemperatureorhumidityeventoccurs.The
Saturn1operatesupto15ampsofmaximumcapacityonastandard120Voltcircuit.
Builtwiththehighestqualitycomponents,theSaturn1willprovidetheuserwithyearsof
troublefreeservice.Controllerscreatedforourindustry,byourindustry!
Instructions for Operation
•SecurelymountyourSaturn1inyourgrowareaandawayfromanymoisture,spray,
pesticides,etc.usingthemountingbracketsandhardwareprovided.
•Plugtheexhaustfanintothe‘FANOUTLET’.
•Turnthefan‘ON’tothefastestsettingpossible,ifadjustable.
•Plugthedehumidierintothe‘HUMIDITYOUTLET’
•Turnthedehumidier‘ON’tothelowestsetting.Thisallowsthecontrollertomaintain
precisecontrolofthehumidityinyourgarden.
•Setthe‘Temperature’and‘Humidity’dialsatthepreferredtemperatureandhumiditylevels
foryourgarden.
•Finally,plugtheSaturn1intoadedicated120Volt–15Amppowersource.
•UseofasurgeprotectiondeviceisrecommendedtoprotectyourSaturn1frompotential
powerdamageinareaswherethismaybeanissue.
•YourSaturn1willnowcontrolyourequipmentatthedesiredsettings.
Troubleshooting Tips
IftheSaturn1isnotperformingasexpected,trythefollowing:
a.Conrmthatyourpowerinputsourceisactivebyusingavoltagetestmeter,andverify
thatthepowerinputsourceisproviding120VoltsofpowertotheSaturn 1.
b.ValidatethatthepoweroutletsoftheSaturn1areactivebysettingthetemperature
andhumiditydialstothelowestsettings.Thenuseavoltagetestmetertoverifypoweris
owingthroughthecontrollertothepoweroutlets.
c.Ensurethattheexhaustfanis‘ON’andsetatthefastestspeed,ifadjustable.
•Controllerswithserialnumbersordatetagsthathavebeenremoved,alteredorobliterated;
brokensealsthatshowevidenceoftampering;mismatchedboardserialnumbersor
nonconformingparts,areexcludedfromcoverage.
•TitanControls®makesnowarrantywhatsoeverinrespecttoaccessoriesorpartsnot
suppliedbyTitanControls®.
•Monetaryrefundsofthewarrantywillnotbegiven.
•TheBuyerassumesallresponsibilityregardingtheproperuse&installationofthis
controller.
•AllwarrantyserviceisprovidedthroughtheTitanControls®factory.
•ThiswarrantyshallapplyonlytotheUnitedStates,includingAlaska,Hawaiiandterritories
oftheUnitedStates.
•Defectivecontrollersarerequiredtobereturnedwiththe“proofofpurchase/receipt”for
warrantycoverage.
•Foradditionalwarrantyinformation,contacttheTitanControls®TechnicalService
RepresentativeoryourlocalDealer.
•NOTE:TitanControls®isaManufacturerofenvironmental,timing,lighting,ventilationand
CO2controls.Allsalesofferingstothepublicaredonethroughanationwidegroupof
Dealers.Nosalesofferingswillbemadedirectlytothegeneralpublic.
Service and Repair Program
• Forallserviceandrepairs,pleasecontactbyourTechnicalServiceRepresentativefor
troubleshootingyourgearandattainingaReturnMerchandiseAuthorization(RMA)number,
ifapplicable.
• Allfactoryservice&repairswillbecompletedwithin48hoursofreceiptofcontrolleratthe
factory.
• TitanControls®will,atitsdiscretion,repairorreplacethecontroller.
• FactorycalibrationservicesareavailableforallTitanControls®.
• ReturningUnits:Pleasecontactyourretailstoreforinformationregardingreturns.
d.Checkthatthedehumidieris‘ON’andsettothelowesthumiditylevel.
e.VerifythattheSaturn1issetatthepropertemperatureandhumiditylevelstoactivate
anddeactivateequipment.
f. Ifyourventilationordehumidicationequipmentdoesnotturnoff,verifythatyourexhaust
fananddehumidierarethecorrectsizeforyourgrowarea.Increasethesizeofexhaust
fanordehumidier(ifnecessary)tocoolanddehumidifythegardenasquicklyaspossible.
g.IfyouarestillhavingproblemswithyourSaturn1,pleasecontactourTechnicalService
Representativeat888-808-4826toassistyoufurther.
Controller Specifications:
• Size=8”Hx6”Wx4”D
• Weight=3lbs.
• InputVoltage=120Volts/AC
• OutputVoltage=120Volts/AC
• MaximumAmperage=15Amps
• OperatingHertz=60Hz
• Minimum/MaximumHumidityControlLevels=20%to80%(non-condensing)
• HumidityAccuracy=±5%ofdesiredsetting
• Minimum/MaximumTemperatureControlLevels=40°to100°F(5°Cto38°C)
• TemperatureAccuracy=±3°Fofdesiredsetting
• Cordset=8feet-14/3SWJ
• StorageTemperature=32°to135°F(0to58°C)
• OperatingTemperature=45°to95°F(7to35°C)
Warranty Information
•TitanControls®warrantstheoriginalpurchaseofthisproductagainstdefectsinmaterial
andworkmanshipundernormaluseforthree(3)yearsfromthedateofpurchase.
•Duringthewarrantyperiod,TitanControls®will,atouroption,andwithoutcharge,repairor
replacethisproductifthecontrolleroranyofitscomponentsfailormalfunction.
•AllreturnsorrepairsmustbeaccompaniedbyaReturnMerchandiseAuthorization(RMA)
numberpriortoanyserviceoftheproduct.
•Thiswarrantyisinlieuofallotherwarranties,expressedorimplied,includingthewarranties
ofmerchantabilityandtnessforuse,andofallotherobligationsorliabilitiesonthepartof
theseller.
•Thiswarrantyshallnotapplytothisproductoranypartthereofwhichhadbeendamaged
byaccident,abuse,misuse,modication,negligence,alterationormisapplication.
Installation Example
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Titan Controls Saturn 1 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI