1 of 1 08/227150-0124
RESPONSIBILITY
DOOR AND FRAME MANUFACTURERS ARE
RESPONSIBLE FOR PROVIDING ADEQUATE
CONSTRUCTION OR REINFORCEMENTS FOR
PROPER INSTALLATION OF HARDWARE SHOWN.
ALL ARCHITECTURAL BUILDERS HARDWARE MUST
BE INSTALLED ON PROPERLY REINFORCED
DOORS AND FRAMES, REGARDLESS OF TYPE,
MATERIAL, OR METHOD OF CONSTRUCTION.
Experience a safer and more open world
Copyright © 2022, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
YPL Series Indicator Lock
2-3/8" and 2-3/4" Backsets
HM or WD Doors
1-800-438-1951
www.yalecommercial.com
BEVELED EDGE
Door
Thickness
SQUARE EDGE
5/32
(4)
±.005
Strike/Lock/Door
1
(25.4) Min
1-1/4
(31.8) Min
Plaster Guard by
Frame Manufacturer
1-1/4
(31.8) (See Note 4)
Strike/Lock
Lock/Door
3/32
(2.4)
5/8
(15.9)
3-3/8
(85.7)
2-1/4
(57.2)
+.015
-.000
+.015
-.000 3/4
(19)
3/8
(9.5)
1-1/4
(31.8)
+.015
-.000
3-1/2
(88.9)
Min
1-13/16
(46)
1-1/4
(31.8)
5/16
(7.9)
Max
4-1/8
(104.8)
±.005
1/2
(13) Min
9/16
(14.3)
Min
4-7/8
(123.8)
+.015
-.000
4-7/8
(123.8)
+.015
-.000
Strike/
Lock/
Prep
#12-24 Tap for
Combination Screw
(2 Places)
#8-32 Tap for
Combination Screw
(2 Places)
+.015
-.000
1-1/8
(28.6)
DOOR DETAIL
1" (25.4) Dia. or
1" (25.4) Square
to prep hole
1-5/8
(41.3)
±.005
5/32
(4)
Lock/Prep
2-15/32
(62.7)
2-1/8
(54) Dia. thru
Dia. thru
(2 Places)
1-3/8
(35)2-3/4
(70)
5/16
(8)
BEVEL
1/8" in 2"
(3.2) (50.8)
A
Backset
(See Note 1)
5/32
(4)
±.005
Notes:
1. Backset is measured from centerline of bevel which is
centerpoint of door thickness.
2. Door prep with 2-3/4" (70) backset meets ANSI/BHMA
A156.115 for steel doors and A156.115W for wood
doors plus through bolt holes shown.
3. Dimensions given in inches and (mm).
4. 1-1/4" strike lip suits frame for 1-3/4" thick door.
CAUTION: DOOR AND FRAME MANUFACTURER
When door gasketing or silencers are used, proper
allowances must be made for strike location to
maintain a common centerline with lock and door
as shown so that bolt will freely enter strike.
TEMPLATE CROSS REFERENCE
DESCRIPTION TEMPLATE
371 T Strike
70S Full Lip Strike
BACKSET “A”
Regular
Optional
TOLERANCES
Inches (mm)
.005 (.127)
.015 (.381)
FRAME DETAIL
ANSI Strike
(Regularly Furnished)