BEA KEYSWITCHES User guide

Type
User guide

BEA KEYSWITCHES are momentary or ON-OFF SPDT keyswitches designed for various access control applications. They feature a durable construction with a mortise cylinder and a switch, both sold separately. The switches are rated for 6A at 125VAC and 3A at 250VAC, making them suitable for a wide range of electrical devices. With their versatile mounting options and adjustable switch height, BEA KEYSWITCHES offer easy installation and precise operation.

BEA KEYSWITCHES are momentary or ON-OFF SPDT keyswitches designed for various access control applications. They feature a durable construction with a mortise cylinder and a switch, both sold separately. The switches are rated for 6A at 125VAC and 3A at 250VAC, making them suitable for a wide range of electrical devices. With their versatile mounting options and adjustable switch height, BEA KEYSWITCHES offer easy installation and precise operation.

©BEA | Original Instructions
75.1020.09 KEYSWITCH MOM AND ON OFF 20230413 Page 1 of 2
(NO)
(COM)
(NC)
2
1
3
A B
12
KEYSWITCH (SINGLE-GANG)
(NO)
(COM)
(NC)
3
Momentary / ON-OFF SPDT keyswitch
(10KEYSWITCHMOM / 10KEYSWITCHONF)
ENGLISH
BEA Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA Inc.
does not guarantee any use of the sensor/device outside its intended purpose.
BEA Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/
device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the system shall be performed and documented per the manufacturer’s
recommendations or industry guidelines. Examples of compliance may apply to ANSI 156.10, ANSI 156.19, ANSI/DASMA 102, ANSI/DASMA 107,
UL294, UL325, and International Building Code.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
SEE OTHER SIDE FOR JAMB
1. Face plate
2. Mortise cylinder1
3. Switch2
6 A @ 125 VAC
3 A @ 250 VAC
MOUNTING
NOTES:
1. Sold separately.
2. If two are required for the application, the second switch must be
purchased separately.
Select cam shape for keyswitches.
Mortise cylinder and second switch
sold separately.
Adjust switch height on bracket
until the cam triggers positively
when rotated.
Wire accordingly.
PRECAUTIONS
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body’s
ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly
or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
Tech Support & Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
A:
Corbin Russwin® #ML2200
Schlage® #B520-233
(or equiv.)
B:
Schlage® #B520-256
Yale® #2160
Arrow® #004
Sargent® #13-0660
(or equiv.)
!
CAUTION
10KEYSWITCHMOM 10KEYSWITCHONF
N.O. white N.O. green
COM black COM black
N.C. red N.C. red
Visit website for available
languages of this document.
©BEA | Original Instructions
75.1020.09 KEYSWITCH MOM AND ON OFF 20230413 Page 2 of 2
2
1
5
3
4
KEYSWITCH (JAMB)
A B
(NO)
(COM)
(NC)
12
(NO)
(COM)
(NC)
3
Momentary / ON-OFF SPDT keyswitch
(10JAMBSWITCHMOM / 10JAMBSWITCHONF)
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body’s
ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly
or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
ENGLISH
Adjust switch height on bracket
until the cam triggers positively
when rotated.
Visit website for available
languages of this document.
SEE OTHER SIDE FOR SINGLE-GANG
1. Face plate
2. Mortise cylinder1
3. Switch bracket
4. Cylinder lock
5. Switch2
6 A @ 125 VAC
3 A @ 250 VAC
MOUNTING
PRECAUTIONS
NOTES:
1. Sold separately.
2. If two are required for the application, the second switch must be
purchased separately.
Tech Support & Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
A:
Corbin Russwin® #ML2200
Schlage® #B520-233
(or equiv.)
B:
Schlage® #B520-256
Yale® #2160
Arrow® #004
Sargent® #13-0660
(or equiv.)
!
CAUTION
Select cam shape for keyswitches.
Mortise cylinder and second switch
sold separately.
Wire accordingly.
10JAMBSWITCHMOM 10JAMBSWITCHONF
N.O. white N.O. green
COM black COM black
N.C. red N.C. red
BEA Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA Inc.
does not guarantee any use of the sensor/device outside its intended purpose.
BEA Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/
device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the system shall be performed and documented per the manufacturer’s
recommendations or industry guidelines. Examples of compliance may apply to ANSI 156.10, ANSI 156.19, ANSI/DASMA 102, ANSI/DASMA 107,
UL294, UL325, and International Building Code.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
  • Page 1 1
  • Page 2 2

BEA KEYSWITCHES User guide

Type
User guide

BEA KEYSWITCHES are momentary or ON-OFF SPDT keyswitches designed for various access control applications. They feature a durable construction with a mortise cylinder and a switch, both sold separately. The switches are rated for 6A at 125VAC and 3A at 250VAC, making them suitable for a wide range of electrical devices. With their versatile mounting options and adjustable switch height, BEA KEYSWITCHES offer easy installation and precise operation.

Ask a question and I''ll find the answer in the document