CMP PX780 Compound Barrier Union Installation guide

Type
Installation guide

CMP PX780 Compound Barrier Union

CMP PX780 Compound Barrier Union is intended to be used with threaded or non-threaded entries to connect conduits to enclosures or to connect conduits to each other in explosive atmospheres. It ensures ingress protection ratings of up to IP68. The union has been independently tested to comply with Category B rating specified in IEC 62444. The union utilizes a two-part epoxy compound to seal the connection, making it suitable for use in hazardous areas.

Here's a summary of its capabilities:

  • Used to connect conduits to enclosures or conduits to each other.

CMP PX780 Compound Barrier Union

CMP PX780 Compound Barrier Union is intended to be used with threaded or non-threaded entries to connect conduits to enclosures or to connect conduits to each other in explosive atmospheres. It ensures ingress protection ratings of up to IP68. The union has been independently tested to comply with Category B rating specified in IEC 62444. The union utilizes a two-part epoxy compound to seal the connection, making it suitable for use in hazardous areas.

Here's a summary of its capabilities:

  • Used to connect conduits to enclosures or conduits to each other.
www.cmp-products.com
UNION TYPE PX FOR CONNECTING CONDUITS TO ENCLOSURES OR CONDUITS TO
EACH OTHER USING BARRIER COMPOUND IN EXPLOSIVE ATMOSPHERES.
TECHNICAL DATA
EXPLOSIVE ATMOSPHERES CLASSIFICATION
INSTALLATION INSTRUCTIONS
ACCESSORIES
INSTALLATION INSTRUCTIONS
FOR UNION TYPE PX780
SPECIAL CONDITIONS FOR SAFE USE
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS
Tel: +44 191 265 7411 • Fax: +44 1670 715 646
E-Mail: customerservices@cmp-products.co.uk • Web: www.cmp-products.com
SCAN FOR INSTALLATION VIDEOS
Product Selection Table
METRIC NPT
Diameter
Over
Cores
Max.
Number
of
Cores
Protrusion
Length
Across
Flats
Hex
Across
Corners
Ø “D”
Installation
Torque
(Nm)
Ordering
Reference
(Brass, Metric)
Male
Forward
Thread
Size
Minimum
Thread
Length
Female
Rear
Thread
Size
Ordering
Reference
(Brass, NPT)
Male
Forward
NPT Thread
Size
Minimum
NPT Thread
Length
(in)
Female Rear
Thread Size
PX780DM2M2 M20 X 1.5 15.0 M20 X 1.5 PX780DT1T1 1/2” 0.79 1/2” 12.6 21 36.0 46.0 50.6 7
PX780DM3M3 M25 X 1.5 15.0 M25 X 1.5 PX780DT2T2 3/4” 0.80 3/4” 17.5 30 36.0 50.0 55.0 10
PX780DM4M4 M32 X 1.5 15.0 M32 X 1.5 PX780DT3T3 1” 0.98 1” 23.6 38 36.0 60.0 66.0 15
PX780DM5M5 M40 X 1.5 15.0 M40 X 1.5 PX780DT4T4 1-1/4” 1.01 1-1/430.0 59 36.0 65.0 71.5 25
PX780DM6M6 M50 X 1.5 15.0 M50 X 1.5 PX780DT5T5 1-1/2” 1.03 1-1/241.0 115 36.0 75.0 82.5 30
PX780DM7M7 M63 X 1.5 15.0 M63 X 1.5 PX780DT6T6 2” 1.06 2” 53.7 115 36.0 90.2 99.2 45
PX780DM8M8 M75 X 1.5 15.0 M75 X 1.5 PX780DT7T7 2-1/2” 1.57 2-1/264.3 140 39.0 99.3 109.2 45
PX780DM9M9 M90 X 2.0 24.0 M90 X 2.0 PX780DT8T8 3” 1.63 3” 75.3 140 42.0 120.0 132.0 45
All dimensions shown are in millimetres unless otherwise stated
For material options please add the following suffix to the Ordering Reference; Brass (no suffix required), Nickel Plated Brass “5”, 316 Grade Stainless Steel “4”, Copper Free Aluminium “1”
FI468
Certicate Revision Date
UKEX 0 04/21
IFS 10 10/21
ATEX / IECEx 8 04/19
CSA / cCSAus
CMP Earth Tag Size Short Circuit Ratings Symmetrical Fault Current
(kA) for 1 second
20 3.06
25 4.06
32 5.40
40 7.20
50 10.40
63 10.40
75 10.40
2776
INCORPORATING EU DECLARATION OF CONFORMITY TO DIRECTIVE 2014/34/EU AND UK STATUTORY
REQUIREMENTS SI 2016 No. 1107 (AS AMENDED)
ADAPTOR TYPE : PX780
INGRESS PROTECTION : IP66 when used with CMP sealing accessories
PROCESS CONTROL SYSTEM : ISO 9001
: ISO/IEC 80079-34:2011
ATEX CERTIFICATION No : CML 18ATEX1327X
ATEX CERTIFICATION CODE : ^II 2G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da IP6X
: ^IM2 Ex db I Mb / Ex eb I Mb
UKEX CERTIFICATION No : CML 21UKEX1240X
UKEX CERTIFICATION CODE : ^II 2G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da IP6X
: ^IM2 Ex db I Mb / Ex eb I Mb
IECEx CERTIFICATION No : IECEx CML 18.0190X
IECEx CERTIFICATION CODE : Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da IP6X, Ex db I Mb, Ex eb I Mb
cCSAus CERTIFICATION No : 1055233
CODE OF PROTECTION : Class I Div 1 & 2, Groups A,B,C,D ; Class I Zone 1, AEx de II; Ex de II
1. Installation should only be performed by a competent person using the correct tools. Spanners should be used for tightening. Read all instructions before beginning installation.
2. The interface between a cable entry device and its associated enclosure / cable entry will require additional sealing to achieve ingress protection (IP) ratings higher than IP54. The minimum protection level is
IP54 for explosive gas atmospheres and IP6X for explosive dust atmospheres. Parallel threads (and tapered threads when using a non-threaded entry) require a CMP sealing washer or integral O-ring face seal
(where available) to maintain IP66, 67 and 68 (when applicable). It is the installer’s responsibility to ensure the IP rating is maintained at the interface.
Note: When fitted to a threaded entry, all tapered threads will automatically provide an ingress protection rating of IP66.
3. A CMP earth tag should be used when it is necessary to provide an earth bond connection. CMP earth tags have been independently tested to comply with Category B rating specified in IEC 62444 (there are
no ratings stated in IEC 60079-0). Ratings are shown in the associated table. CMP earth tags slip over the cable gland or accessory entry thread from inside/outside the enclosure and must be secured with a
locknut (if fitted internally).
Only one union is to be used with any single cable entry on the associated equipment.
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing :-
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer
CMP Products Limited on its sole responsibility declares that the equipment referred to herein conforms to the requirements of the ATEX Directive 2014/34/EU and UK statutory
requirements SI 2016 No. 1107 (as amended). This is shown in the following harmonised/designated standards;
EN IEC 60079-0:2018, EN 60079-1:2014, EN IEC 60079-7:2015 + A1:2018, EN 60079-31:2014
Jonathan Hichens - Lead Certification Engineer - (Authorised Person)
CMP Products Limited, Cramlington, NE23 1WH, UK
EU Economic Operator: CMP Products Germany GmbH. Address: Lukasstraße 25a, 52070 Aachen
17th March 2020
2503
Notified Body: CML B.V., Koopvaardijweg 32, 4906CV Oosterhout, The Netherlands
Approved Body: Eurofins E&E CML Limited, Newport Business Park, New Port Road, Ellesmere Port, CH65 4LZ
www.cmp-products.comwww.cmp-products.com
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND TYPES PX780
UNION COMPONENTS - It is not necessary to dismantle the cable gland any further than illustrated below
1. Entry Item
2. Serrated Flamepath
3. Nut
4. Conduit Connector
5. Washer
6. Compound Tube
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION
2. Prepare the cable by removing the outer sheath from the cores so that they are exposed within
the Compound Tube when finally assembled.
1. 2. 3. 4.
NOTE: THERE IS NO NEED TO DISSASSEMBLE THE UNION
6. Bring the cores together again and pack more compound around them to a length and diameter sufficient to fill the
Compound Tube (6) (ensuring compound is packed between each of the cable cores) before ending in a taper.
5.
6.
3. Feed the cables/cores through the conduit connector (4), nut (3)
and washer (5), tighten the conduit connector onto the conduit.
4. Wearing the protective gloves supplied, mix all of the two-part
epoxy compound until it is pliable and an even colour is achieved
(Min. mixing temperature 10° / 50° F
8. Attach the Entry Item (1) by screwing it into place, making sure the compound is not disturbed, and loosely tighten the
Nut (3). Leave until the compound has cured.
1. Slacken and remove the nut (3) to disassemble the union.
5. Separate the cable cores and apply the compound to the crutch of the
cable for a distance of about 6mm and pack into place. If the cable has
individual or overall foil screens then these should be removed.
If a drain wire is present then it should be sleeved with
some heat shrink tubing which is pushed into the
compound before shrinking with the application of some
heat. If braid screens have been twisted together they
should be treated as a drain wire and sleeved.
PACK THIS END
TRIM EXCESS
1
2
9. When the compound has cured the Entry Item (1) should be removed from the assembly and fully tightened into the
apparatus. The Union can then be refitted to it and the Nut (3) fully tightened to complete the installation.
7. Pass the Compound Tube (6) over the conductors until the stepped end is fully located with the Washer (5). Pack more
compound into place until the Compound Tube is fully fitted and trim off any excess.
  • Page 1 1
  • Page 2 2

CMP PX780 Compound Barrier Union Installation guide

Type
Installation guide

CMP PX780 Compound Barrier Union

CMP PX780 Compound Barrier Union is intended to be used with threaded or non-threaded entries to connect conduits to enclosures or to connect conduits to each other in explosive atmospheres. It ensures ingress protection ratings of up to IP68. The union has been independently tested to comply with Category B rating specified in IEC 62444. The union utilizes a two-part epoxy compound to seal the connection, making it suitable for use in hazardous areas.

Here's a summary of its capabilities:

  • Used to connect conduits to enclosures or conduits to each other.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI