Hawke 114 is a certified industrial-grade cable gland suitable for a wide range of applications. It offers an ingress protection rating of IP66, ensuring protection against dust, solid objects, and water. The gland's operating temperature range of -60°C to +100°C makes it suitable for use in harsh environments. Hawke 114 is designed to provide a secure connection between cables and enclosures, preventing the ingress of contaminants and maintaining the integrity of the electrical system.

Hawke 114 is a certified industrial-grade cable gland suitable for a wide range of applications. It offers an ingress protection rating of IP66, ensuring protection against dust, solid objects, and water. The gland's operating temperature range of -60°C to +100°C makes it suitable for use in harsh environments. Hawke 114 is designed to provide a secure connection between cables and enclosures, preventing the ingress of contaminants and maintaining the integrity of the electrical system.

Operating temperature range -60°C +100°C Certification Details
IMPORTANT: Prior to installation, it may be
necessary to release conduit from its clamping
mechanism to allow sucient movement.
1. Backnut
2. Running Coupler
3. Spring Clip
4. Seal
5. Entry
Sub-Assembly
Gland Type: 114 IP66 Industrial
EN 62444
Certicate of Assessment: CML 15CA932-2
Assembly Instructions for cable gland:
114 Industrial General Purpose
AI 394 / Issue F
Cable Preparation Gland Preparation
A
Pull sucient length 'I' of cable through conduit/
cable gland to suit equipment. Screw backnut
onto pre-threaded conduit/cable gland and
tighten with spanner/wrench.
B
Pass the cable through the entry
and seal
which may have previously been tted into the
equipment.
C
Locate the running coupler
onto the entry
and tighten using a wrench/spanner until resistance
is felt between the seal and cable, then turn the
running coupler through a further half to one full
turn to complete the inner seal, ensuring that entry
is prevented from turning and backnut
remains
tight on the conduit. This procedure compresses the
seal
into contact with the cable outer sheath.
I
5mm minimum
Conduit
or Cable Gland
Conduit or
Cable Gland
15mm minimum
thread length
2
1
3
5
4
2
1
11
2
5
3
2
1
2
5
www.ehawke.com
UK Oce
Oxford Street West,
Ashton-Under-Lyne,
Lancashire. OL7 0NA. UK
Sales: +44 (0) 161 830 6698
Technical: +44 (0) 161 830 6697
Fax: +44 (0) 161 830 6648
Connection Solutions
AI 394 - Issue F / Page 1 of 2
A member of the Hubbell Group of Companies
Hawke International is a division of Hubbell Ltd.
Registered No. 669157 in England. Registered Oce:
Cannon Place, 78 Cannon Street, London EC4N 6AF.
INSTALLATION GUIDELINES:
A seal must be formed between the equipment and the cable gland to
maintain the appropriate degree of protection against ingress of dust,
solid objects and water.
AI 394 - Issue F / Page 2 of 2
ACCESSORIES:
Before cable gland assembly or stripping of the cable gland assembly,
consideration should be given to any cable gland accessories that may be
required, such as: -
Shroud, to oer additional corrosion protection.
Locknut, to secure cable glands into position.
Sealing washer, to oer additional ingress protection of the enclosure
at the cable gland entry.
Earthtag, to provide an external armour/braid bonding point.
Serrated washer, to dampen any vibrations that may loosen the
locknut or cable gland assembly.
Declaration of Conformity in accordance with European Directive
2006/95/EC (until 19th April 2016) and
EU Declaration of Conformity in accordance with European Directive
2014/35/EU (from 20th April 2016)
Manufacturer: Hawke International
Address: Oxford Street West, Ashton-under-Lyne, OL7 0NA, United Kingdom.
Equipment Type: 114 Industrial Gland
On behalf of the above named company, I declare that, on the date the
equipment accompanied by this declaration is placed on the market, the
equipment conforms with all technical and regulatory requirements of the
above listed directives.
Standards used: EN 62444 : 2013
………………………………….
A. Reid
Technical Manager
CABLE GLAND CLASSIFICATION
Cable
Gland
Type
114
Material
Non-Metallic
Metal
Composite
Without Cable
Anchorage
With Cable
Anchorage
Impact Category
Cable Retention
(Armoured Cable)
Equipotential
Bonding
Connection to
Metallic Layers
Protective Connection
to Earth
Insulation
Characteristics
Ingress Protection
Temperatire Range
Resistance to Salt and
Sulpher Dioxide Laden
Atmospheres
Single Orice Seal
Multi-Orice Seal
Mechanical Properties Electrical Properties External Inuences Sealing
System
Type Category Class Category IP66 -60° to
100°
YXA8XYXXXYYYYX
CONDUIT CABLE GLAND SELECTION TABLE
Male Entry
Thread Size
Metric
Size
Ref.
NPT
Across
Flats
Across
Corners
Hexagon
Dimensions
Max
Length
A
B
C
M20
M25
M32
10.0
13.0
19.0
14.3
20.2
26.5
30.069
61
77
36.0
46.0
32.5
39.5
50.5
Outer Sheath
Min. Max.
Female Entry
Thread Size
Metric
NPT
Standard
Seal
Alternative
Seal (S)
9.0
9.5
15.5
13.4
15.4
21.2
Min. Max.
M20
M25
M32
½" - ¾"
¾" - 1"
1" - 1¼"
#
#
Os
O
M20
M20
8.0
11.9
3.0
6.5
24.069
69 24.0
27.7
27.7
---
---
---
---
M20
M20
½"
½"
#
#
#
C2 M32 25.0 32.5 79 55.0 60.622.0 28.0M401¼ - 1½" #
D M32 31.5 44.4/42.3 ¹ 105 65.0 70.827.5 34.8M501½" - 2" #
E M32 42.5 56.3/54.3 ¹ 105 80.0 88.039.0 46.5M632" - 2½" #
F M32 54.5 68.2/65.3 ¹ 107 95.0 104.048.5 58.3M752½" - 3" #
# Thread sizes specied with order.
¹ Smaller value is applicable when selecting reduced NPT male entry option.
Sizes Os and O are available with an M16 thread size. If M16 entry is used on O
size Cable Glands the maximum cable inner sheath diameter is limited to 10.9mm.
  • Page 1 1
  • Page 2 2

Hawke 114 Assembly Instructions

Category
Signal cables
Type
Assembly Instructions

Hawke 114 is a certified industrial-grade cable gland suitable for a wide range of applications. It offers an ingress protection rating of IP66, ensuring protection against dust, solid objects, and water. The gland's operating temperature range of -60°C to +100°C makes it suitable for use in harsh environments. Hawke 114 is designed to provide a secure connection between cables and enclosures, preventing the ingress of contaminants and maintaining the integrity of the electrical system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI