B-K lighting Delta Star - MR16 Installation guide

Type
Installation guide

B-K lighting Delta Star - MR16 is a highly functional device that provides ample lighting in any outdoor area. Boasting a durable construction and a range of mounting options, the Delta Star can be installed on walls, ceilings, or even the ground to provide optimal illumination. With its adjustable head and glare-reducing lens, you can direct light precisely where it's needed while minimizing light pollution and enhancing visual comfort.

B-K lighting Delta Star - MR16 is a highly functional device that provides ample lighting in any outdoor area. Boasting a durable construction and a range of mounting options, the Delta Star can be installed on walls, ceilings, or even the ground to provide optimal illumination. With its adjustable head and glare-reducing lens, you can direct light precisely where it's needed while minimizing light pollution and enhancing visual comfort.

REFERENCE NUMBER
INS000999
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
TECHNOLOGY
with TECHNOLOGY
TOOLS
NEEDED:
By Others
5/32” Allen Wrench
Phillips Screwdriver
Waterproof Wire Connectors
Stability Flange
Power Pipe
18 Gauge Wire
Transformer
Housing
With B-Cap
Mounting Option
RELEASE DATE
11-30-16
Warning Flammable Hot Surface
This set of instructions works for:
SF-B - Staff Star™ Style “B”
SF-C - Staff Star™ Style “C”
SF-L - Staff Star™ Style “L”
SF-MN-B - Micro Nite™ Pathlight Style “B”
SF-MN-C - Micro Nite™ Pathlight Style “C”
SF-MN-L - Micro Nite™ Pathlight Style “L”
TF-B - Twin Staff Star™ Style “B”
TF-C - Twin Staff Star™ Style “C”
TF-MN-B - Micro Nite Twin Pathlight Style “B”
TF-MN-C - Micro Nite Twin Pathlight Style “C”
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping of
this product.
Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use
a clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when
turning on.
Do not touch hot lens, guard, or enclosure (see diagram/
picture).
Keep lamp away from materials that may burn.
Do no touch the lamp at any time. Use a soft cloth. Oil
from skin may damage lamp.
Do not operate the luminaire fitting with a missing or
damaged shield.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations • Suitable for mounting within 4 ft. of the ground.
IMPORTANT LISTINGS AND CERTIFICATIONS
Please refer to the low voltage design guide at www.bklighting.com/lvguide before installation for proper wire selection.
SF-MN-B TF-B
SF-L
SF-MN-C
SF-MN-L
SF-C
TF-MN-B
TF-C
TF-MN-C
SF-B
Standard Installation Instructions
& Low Voltage STAFF STAR™ & TWIN STAFF STAR™
PROJECT:
TYPE:
REFERENCE NUMBER
INS000999
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
4. Pull low voltage wiring from remote 12V
transformer (By Others) to Power Pipe™. Allow for
additional cable to make connections to fixture
lead and future service. Place Power Pipe™ in hole.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
2. Slide optional Stability Flange onto Power
Pipe™. Use optional Stability Flange to aid in
installation of Power Pipe™.
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 24” deep and 10”
wide to accommodate Power Pipe™ at desired
fixture locations.
POWER PIPE INSTALLATION
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
5. Back fill with pea gravel or sand prior to pour.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
6. Pour concrete (By Others).
Label on Power Pipe™ indicates installation
depth with finished grade.
RELEASE DATE
11-30-16
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
TECHNOLOGY
with TECHNOLOGY
Standard Installation Instructions
& Low Voltage STAFF STAR™ & TWIN STAFF STAR™
3. Loop 12” of low voltage wire inside Power Pipe™.
Do not remove temporary cover.
NOTE: Leave sufficient wire length in the
Power Pipe™ for future service. Do not cut
PVC.
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE II™ IS LABELED AT GRADE LEVEL.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY
Soil Prep
Conduit
trench
B. Dig hole 10” wide and 24” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
A. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.
RELEASE DATE
11-30-16
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
4 3/4"
(120mm)
5"
(127mm)
2 1/4"
(57mm)
1 3/8"
(35mm)
18" Power Pipe™
Stake (457mm)
18" Power Pipe™
Stake (457mm)
1" Dia.
(25mm)
Available up to 48" Overall
Heights (RemoteTransformer)
Available up to 48" Overall
Heights (Integral Transformer)
Available up to 72" Overall
Heights (Remote Transformer)
Optional
Stability Flange Optional
Stability Flange
5 7/8" Dia.
(149mm)
Specify Length
72" Maximum
(1829mm) Patent Pending
Adjust-e-Lume®
Specify Length
48" Maximum
(1219mm)
Specify Length
48" Maximum
(1219mm)
REFERENCE NUMBER
INS000999
TECHNOLOGY
with TECHNOLOGY
8. Place wires, connectors and transformer into
transformer housing and attach to Power
Pipe™. Tighten three (3) #8-32 stainless steel
round head Phillips screws at transformer
housing base to secure.
120V 12V
FIXTURE
COM
GROUND
WIRING DIAGRAM
Transformer
COM
GROUND IN T-HOUSING
120V 12V
LAMP
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
120V 12V
FIXTURE
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
6. Make watertight connections from branch
circuit wiring to transformer primary leads
using waterproof wire connectors (By Others).
See wiring diagram.
7. Attach ground from branch circuit to ground
screw in transformer housing.
9. Use 5/32” Allen wrench to loosen #10-32 stainless
steel black oxide socket head cap screw at the
knuckle. Aim fixture to desired vertical location.
Tighten to secure aiming position.
POWER PIPE WITH TRANSFORMER HOUSING BASE MOUNTING OPTION
Standard Installation Instructions
& Low Voltage STAFF STAR™ & TWIN STAFF STAR™
7. Place fixture on Power Pipe™. Tighten three (3)
#8-32 stainless steel round head Phillips screws
to secure to installed Power Pipe™.
LINE 12V
FIXTURE
COM
WIRING DIAGRAM
Remote
Magnetic
Transformer
COM
6. Make watertight connections from remote 12V
transformer to lamp leads (18 gauge wire) using
waterproof wire connectors (By Others). See
wiring diagram.
8. Use 5/32” Allen wrench to loosen #10-32 stainless
steel black oxide socket head cap screw at the
knuckle. Aim fixture to desired vertical location.
Tighten to secure aiming position.
POWER PIPE WITH B CAP FIXTURE MOUNTING OPTION
WIRING DIAGRAM
LED - For use with 12VAC remote
transformer or magnetic transformers only.
B-K Lighting cannot guarantee performance
with third party manufacturers’
transformers.
Low Voltage - For use with 12VAC remote
transformer.
REFERENCE NUMBER
INS000999.1
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
4 3/4"
(120mm)
5"
(127mm)
2 1/4"
(57mm)
1 3/8"
(35mm)
18" Power Pipe™
Stake (457mm)
18" Power Pipe™
Stake (457mm)
1" Dia.
(25mm)
Available up to 48" Overall
Heights (RemoteTransformer)
Available up to 48" Overall
Heights (Integral Transformer)
Available up to 72" Overall
Heights (Remote Transformer)
Optional
Stability Flange Optional
Stability Flange
5 7/8" Dia.
(149mm)
Specify Length
72" Maximum
(1829mm) Patent Pending
Adjust-e-Lume®
Specify Length
48" Maximum
(1219mm)
Specify Length
48" Maximum
(1219mm)
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
This set of instructions works for:
SF-B - Staff Star™ Style “B”
SF-C - Staff Star™ Style “C”
SF-L - Staff Star™ Style “L”
SF-MN-B - Micro Nite™ Pathlight Style “B”
SF-MN-C - Micro Nite™ Pathlight Style “C”
SF-MN-L - Micro Nite™ Pathlight Style “L”
TF-B - Twin Staff Star™ Style “B”
TF-C - Twin Staff Star™ Style “C”
TF-MN-B - Micro Nite Twin Pathlight Style “B”
TF-MN-C - Micro Nite Twin Pathlight Style “C”
SF-B
Warning Flammable Hot Surface
TOOLS
NEEDED:
By Others
5/32” Allen Wrench
Standard Screwdriver
Waterproof Wire Connectors
RELEASE DATE
11-30-16
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping of
this product.
Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
Do not block light emanating from product in whole or part,
as this may cause an unsafe condition.
Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use
a clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure
(see diagram/picture).
Keep lamp away from materials that may burn.
Do no touch the lamp at any time. Use a soft cloth.
Oil from skin may damage lamp.
Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
• Suitable for wet locations • Suitable for mounting within 4 ft. of the ground.
IMPORTANT LISTINGS AND CERTIFICATIONS
TECHNOLOGY
with TECHNOLOGY
Anchor Base Installation Instructions
& Low Voltage
Please refer to the low voltage design guide at www.bklighting.com/lvguide before installation for proper wire selection.
SF-MN-B TF-B
SF-L
SF-MN-C
SF-MN-L
SF-C
TF-MN-B
TF-C
TF-MN-C
STAFF STAR™ & TWIN STAFF STAR™
RELEASE DATE
11-30-16
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PROJECT:
TYPE:
4 3/4"
(120mm)
5"
(127mm)
2 1/4"
(57mm)
1 3/8"
(35mm)
18" Power Pipe™
Stake (457mm)
18" Power Pipe™
Stake (457mm)
1" Dia.
(25mm)
Available up to 48" Overall
Heights (RemoteTransformer)
Available up to 48" Overall
Heights (Integral Transformer)
Available up to 72" Overall
Heights (Remote Transformer)
Optional
Stability Flange Optional
Stability Flange
5 7/8" Dia.
(149mm)
Specify Length
72" Maximum
(1829mm) Patent Pending
Adjust-e-Lume®
Specify Length
48" Maximum
(1219mm)
Specify Length
48" Maximum
(1219mm)
REFERENCE NUMBER
INS000999.1
3. Pull low voltage wiring from remote 12V
transformer (By Others) to junction box on
anchor base. Allow for additional cable to make
connections to fixture lead and future service.
Place anchor base in hole.
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 18” deep and 10”
wide to accommodate anchor base at desired
fixture locations.
ANCHOR BASE MOUNTING OPTION
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
4. Back fill with pea gravel or sand prior to pour.
Junction box can be installed above or below
grade level.
7. Make watertight connections from remote 12V
transformer to fixture leads using waterproof wire
connectors (By Others). See wiring diagram.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
6. For below ground installation. Pour concrete
(By Others) to grade and flush with junction
box.
8. Attach box cover to junction box by tightening
two (2) #6-32 stainless steel slotted screws to
secure.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
5. For above ground installation. Pour concrete
(By Others) below junction box.
2. Connect 1/2” conduit connector through
female threaded conduit entry.
9. Use 5/32” Allen wrench to loosen #10-32 stainless
steel black oxide socket head cap screw at the
knuckle. Aim fixture to desired vertical location.
Tighten to secure aiming position.
TECHNOLOGY
with TECHNOLOGY
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
WIRING DIAGRAM
Integral
Transformer
COM
GROUND
Anchor Base Installation Instructions
& Low Voltage STAFF STAR™ & TWIN STAFF STAR™
WIRING DIAGRAM
LED - For use with 12VAC remote
transformer or magnetic transformers only.
B-K Lighting cannot guarantee performance
with third party manufacturers’ transformers.
Low Voltage - For use with 12VAC remote
transformer.
RELEASED
10-31-13
REFERENCE NUMBER
INS000004
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
LED / Low Voltage Halogen
2-1/4” Size
RE-PLACING LED BOARD/DRIVER AND OPTICS
1. Use 5/64” Allen wrench to loosen #8-32
stainless set screw and remove cap.
4. Disengage LED board and driver assembly.
Replace with new board and driver assembly.
5. Reverse install LED board and driver.
6. With flat head screw driver rotate dial to
desired lumen output. Replace cap.
2. Space three fingers evenly around the optic
and gently rock optic to remove.
3. Use 5/64” Allen wrench to remove two (2)
#2-56 socket head cap screws on LED board,
grasp LED board and gently pull up to expose
quick disconnect.
TO CHANGE LUMEN OUTPUT (WHEN REQUIRED)
1. Use 5/64” Allen wrench to loosen #8-32
stainless set screw and remove cap.
3. Place cap on fixture and tighten set screw.
Tighten screw to 1/2 inch pounds. Top of
screw should sit flush with fixture cap.
2. With flat head screw driver rotate dial to
desired lumen output.
This product is available with Adjust-e-Lume® (Patent Pend.) for DynamicLLumen Output Control
Warning! The light output of this product may be dynamically adjusted as desired to raise and lower light levels. Please ensure the xture is set
to the appropriate light level desired during installation.
Warning: Do not over tighten set screw.
Doing so will compromise O Ring seal and
will void warranty.
TECHNOLOGY
with
TECHNOLOGY
LAMP INSTALLATION OR RE-LAMPING IF REQUIRED FOR LOW VOLTAGE HALOGEN LAMPS
1. Use 5/64” Allen wrench to loosen #8-32
stainless set screw and remove cap.
1A. Or unscrew lens assembly and install lamp
per step 2.
3. Place cap on fixture and tighten set screw.
Tighten screw to 1/2 inch pounds. Top of
screw should sit flush with fixture cap.
Warning: Do not over tighten set screw.
Doing so will compromise O Ring seal and
will void warranty.
2. Firmly insert lamp pins into socket to make
connection. Rocking motion may be required.
Do not exceed the maximum wattage listed
on the fixture label before installing.
Replacement / Installation Instructions
1. Use 5/64” Allen wrench to loosen #8-32 stainless set
screw and remove cap.
2. Space three fingers evenly around the optic and
gently rock optic to remove.
4. Disengage LED board and driver assembly. Replace
with new board and driver assembly.
5. Reverse install LED board and driver by carefully
wrapping 18 gauge wires around driver and
inserting into fixture body. Secure LED board in
place with stainless steel screws.
6. Snap optics in place. Place cap on fixture and
tighten set screw.
3. Use 5/64” Allen wrench to remove two
(2) #2-56 socket head cap screws on LED
board, grasp LED board and gently pull up to
expose quick disconnect.
REPLACING LED BOARD/DRIVER AND OPTICS
REPLACING LOW VOLTAGE HALOGEN LAMPS
1. Use 5/64” Allen wrench to loosen #8-32 stainless
set screw and remove cap.
3. Place cap on fixture and tighten set screw. Tighten
screw to 1/2 inch pounds. Top of screw should sit
flush with fixture cap.
Warning: Do not over tighten set screw.
Doing so will compromise O Ring seal and will
void warranty.
2. Firmly insert lamp pins into socket to make
connection. Rocking motion maybe required.
Do not exceed the maximum wattage listed
on the fixture label before installing.
LED / Low Voltage Halogen
1-5/8” Size
Replacement / Installation Instructions
RELEASED
11-18-14
REFERENCE NUMBER
INS000010
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
RELEASED
6-19-14
REFERENCE NUMBER
INS-2164-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
Warning Hot Surface
TOOLS
NEEDED:
By Others
5/32” Allen Wrench
L.O.C.K.™ Knuckle System
Standard Adjustment
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
NationalElectricalCode,CanadianElectricalCode,andallLocal
andProvincialCodes.
• Followproductlabelinformationandinstructions.
• QualifiedPersonnel mustperform allservicingorrelampingof
thisproduct.
• Beforewiringtopowersupplyandduringservicingorrelamping,
turnoffpoweratfuseorcircuitbreakerbeforeservice.
• The use of accessory equipment not recommended by the
manufacturerorinstalledcontrarytoinstructionsmaycausean
unsafecondition.Theuseofdamagedcomponentsmaycause
anunsafeconditionandvoidproductwarranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Donotblocklightemanatingfromproductinwholeorpart,
asthismaycauseanunsafecondition.
• Never operate the fixture with missing or damaged lens.
Lensmustbecleanedonregularbasis.
• Entire fixture may become extremely hot. Do not touch hot
lensorfixturebody.Donottouchthelampatanytime.Use
aclean,dry,softclothtohandlethelamp.Oilfromskinmay
damagethelampandcauseittorupture.
• Replace lamp only with correct wattage and type of lamp
markedonfixturelabel.
• All gaskets, O-rings and sealing surfaces must be kept clean
duringinstallationandservice;failuretodothismaycausean
unsafeconditionandvoidproductwarranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
LightedlampisHOT!
WARNING-ToreducetheriskofFIREORINJURYTOPERSONS:
Turnoff/unplugandallowtocoolbeforereplacinglamp.
LampgetsHOTquickly!Contactonlyswitch/plugwhen
turningon.
Donottouchhotlens,guard,orenclosure(seediagram/
picture).
Keeplampawayfrommaterialsthatmayburn.
Donotouchthelampatanytime.Useasoftcloth.Oil
fromskinmaydamagelamp.
Donotoperatetheluminairefittingwithamissingor
damagedshield.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
IMPORTANT LISTINGS AND CERTIFICATIONS
L.O.C.K.™ Knuckle - (Locking ‘O’ Ring Compression Knuckle)
2. Aimfixturetodesiredangle.1. Use 5/32” Allen wrench to slightly loosen #10-32
stainlesssteelsetscrewonthestemfor180°aiming
purpose.
3. Tighten#10-32stainlesssteelsetscrewusinga5/32”
Allenwrenchtosecureaimingposition.
Warning: Do not over tighten set screw. Doing
so will compromise O-ring seal and will void
warranty.
RELEASED
1-31-14
REFERENCE NUMBER
INS-2097-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
Warning Hot Surface
TOOLS
NEEDED:
By Others
5/32” & 5/64” Allen wrench
360SL™ Mounting System
Standard Adjustment
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
NationalElectricalCode,CanadianElectricalCode,andallLocal
andProvincialCodes.
• Followproductlabelinformationandinstructions.
• QualifiedPersonnel mustperform allservicingorrelampingof
thisproduct.
• Beforewiringtopowersupplyandduringservicingorrelamping,
turnoffpoweratfuseorcircuitbreakerbeforeservice.
• The use of accessory equipment not recommended by the
manufacturerorinstalledcontrarytoinstructionsmaycausean
unsafecondition.Theuseofdamagedcomponentsmaycause
anunsafeconditionandvoidproductwarranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Donotblocklightemanatingfromproductinwholeorpart,
asthismaycauseanunsafecondition.
• Never operate the fixture with missing or damaged lens.
Lensmustbecleanedonregularbasis.
• Entire fixture may become extremely hot. Do not touch hot
lensorfixturebody.Donottouchthelampatanytime.Use
aclean,dry,softclothtohandlethelamp.Oilfromskinmay
damagethelampandcauseittorupture.
• Replace lamp only with correct wattage and type of lamp
markedonfixturelabel.
• All gaskets, O-rings and sealing surfaces must be kept clean
duringinstallationandservice;failuretodothismaycausean
unsafeconditionandvoidproductwarranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
LightedlampisHOT!
WARNING-ToreducetheriskofFIREORINJURYTOPERSONS:
Turnoff/unplugandallowtocoolbeforereplacinglamp.
LampgetsHOTquickly!Contactonlyswitch/plugwhen
turningon.
Donottouchhotlens,guard,orenclosure(seediagram/
picture).
Keeplampawayfrommaterialsthatmayburn.
Donotouchthelampatanytime.Useasoftcloth.Oil
fromskinmaydamagelamp.
Donotoperatetheluminairefittingwithamissingor
damagedshield.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
IMPORTANT LISTINGS AND CERTIFICATIONS
360SL™ Knuckle
2. Rotate fixture at base and aim fixture to desired
horizontallocation.
3. Use 5/32” Allen wrench to loosen #10-32 stainless
steel black oxide socket head cap screw at the
knuckleforverticalaimingpurpose.
1. Use 5/64” Allen wrench to slightly loosen two (2)
#8-32stainlesssteelsetscrewsonthestemfor360°
aimingpurpose.
4. Tighten two (2) #8-32 stainless steel set screws on
stemtosecurehorizontalaimingposition.
Tighten #10-32 stainless steel black oxide socket
head cap screw to 15” minimum to 30” maximum
poundstosecureverticalaimingposition.
Warning: Do not over tighten set screw. Doing
so will compromise O-ring seal and will void
warranty.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

B-K lighting Delta Star - MR16 Installation guide

Type
Installation guide

B-K lighting Delta Star - MR16 is a highly functional device that provides ample lighting in any outdoor area. Boasting a durable construction and a range of mounting options, the Delta Star can be installed on walls, ceilings, or even the ground to provide optimal illumination. With its adjustable head and glare-reducing lens, you can direct light precisely where it's needed while minimizing light pollution and enhancing visual comfort.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI