DANLERS CEFLA PIRSD Installation guide

Type
Installation guide
Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1andBSEN55015.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.a10ampcircuitbreakerandvoltagesurgeprotection.
Pleaseensurethatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
 CeilingushPIRabsenceswitch/dimcontrol
 CEFLAPIRSD
DANLERSceilingushpassiveinfra-redabsenceswitch/dimcontrols
(CEFLAPIRSD)canbeushmountedintosuspendedandplasterboard
ceilings(diagramA).Theyincludea2metreconnectingextomake
installationquickerandeasier.
CEFLAPIRSDcontrolsincorporateapassiveinfra-redquadsensorto
detectmovementofawarmbodywithintheirdetectionzone(diagram
B)andaphotocelltomonitortheambientlightlevel.
Whenenteringtheroom,iftheambientlightisdarkenough,thelightscan
beactivatedbyusingamomentarylightswitch.Theambientthreshold
canbesetbytheusertobetweenapproximately 30 lux and 1000 lux
and maximum (photocell inactive) at the PIR via the LUX adjuster
(diagram C). Ifnomoremovementisdetectedwithinapre-selected
time,thentheCEFLAPIRSDwillswitchtheloadoff.Thistimelagcan
besetviatheTIMEadjusterto10seconds,20s,40s,80s,2m30s,5m,
10m, 20m or 40 minutes (diagram C).
Pressingthemomentaryswitchagain (while CEFLAPIRSD isinits
ONstate)willoperatetheSWITCHANDDIMfunctionoftheballast.
Pleaserefertoballastmanufacturer’sdatasheetsforoperationand
synchronisationoftheballast.
Loading
CEFLAPIRSDcanswitchupto:
6amps(1500W)ofresistiveloads.
6amps(1500W)ofuorescentloads.
3amps(750W)ofelectronicandwirewoundtransformerloads.
2amps(500W)ofCFL,2Dlamps,LEDDriversandLEDlamps
andttings.
1amp(250W)offans.
Minimumload2Wresistive,suitableformostenergysavinglamps,
LEDsandemergencyttings.
15/12/15 INS224 CEFLAPIRSD
Troubleshooting
Theloadwillnotswitchon:
• TheLUXadjusterissettoolowandisinhibitingtheswitch.
• ThemovingbodyisnotemittingmoreIRthanthebackground.
  (Personwearinginsulatingclothinginawarmenvironment)
• PersonistoofarfromthePIRswitch,seedetectiondiagram.
• Personismovingunusuallyslowly(perhapswhentesting).
• PleasecontactDANLERSforfurthertechnicalsupport.
Momentaryswitches
DANLERScansupplyarangeofMomentary/Retractiveswitches-
push to make or break:
MOMSWMP-PlatedgreymetalnishwithPRESSpreprintedonswitch.
MOMSWM-Platedgreymetalnishwithblankswitch.
MOMSWWHP-PlatedwhitenishwithPRESSpreprintedonswitch
MOMSWWH-Platedwhitenishwithblankswitch.
MOMSWPMOD-GridmodulesuitableforMKGridPluswithPRESS
preprintedonswitch.
MOMSWMOD-GridmodulesuitableforMKGridPluswithblankswitch.
Installationprocedure
1.Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
2.
POSITIONING: The CEFLAPIRSD should be installed to achieve
correct
coverageofthearea,seediagramA.
Ifthephotocelloverride
facilityisrequired,theswitchmustbelocatedaboveanareawhere
daylightcangivegreaterilluminationthanthearticiallight.Avoid
locatingthisproductwhereitisexposedtowindyordraftyconditions
(exposed lobbies, open ceiling voids or near ventilation fans) or
nearheatsources.TocoverlargeareasCEFLAPIRSDsshouldbe
spacedina5metregridformation.
3.
The greatest energy savings will be made if each
CEFLAPIRSD
controls
anindependentsetoflamps.Theycanbewiredinparallel
but this should ideally be limited to three, see diagram E.
4.Makesurethepowerisisolatedfromthecircuit.
The
CEFLAPIRSD
shouldbeconnectedasshownindiagramsD&E:
L-Livein.N-Neutralin.SW1 /AB-Switchinput.SL-SwitchedLineout.
 Terminatethemainscablewiththesuppliedterminalblock(terminal
blocksmustcomplywithEN60998-1orEN60998-2-1andbesuitable
for0.75-1.5mm2conductors).Inordertocomplywithwiringregulations,
theterminalblockmustbeenclosedinasuitablewiringbox(Thisshould
complywithEN60670-1orEN60670-22).
Start-upmode
WhentheCEFLAPIRSDispoweredup,itwillswitchontheloadfor1
minute,theloadwillthenswitchoffandtheCEFLAPIRSDwillenter
itsOperatingMode.
TimeandLuxset-up
Forconvenience,ensurethattheTIMEissettotheminimumwhen
settinguptheLUXlevel.AfterwardssettheTIMEtoavaluesuitable
fortheapplication,makingreferencetodiagramC.
TheLUXisbestsetupwhenthelocalambientlightisatapproximately
theminimumdesiredworkinglightlevel.WiththeLUXsetfullyclockwise
waitforthe
CEFLAPIRSD
toswitchoff.SteptheLUXadjusterslowly
anticlockwise(-to+),ateachpositionoperatethemomentarywall
switchandcontinuinguntilthelampsswitchon.
Clearance hole
63 or 64mm (2.5") diameter
Springs can either be left closed (down
the side of the product) or opened out.
TIME
minmax
LUX
maxmin
Typical settings
30 LUX
1000 LUX
PHOTOCELL
INACTIVE 40m
20m
10m
5m
2.5m
80s
10s
20s
40s
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR
Secondary detection zone
i.e. person walking
perpendicular to PIR
For optimum coverage
recommended mounting
height: 2.4 to 5m
A:Mountingdiagram
B:Detectiondiagram
D:Wiringdiagram,singleCEFLAPIRSD E:Wiringdiagram,multipleCEFLAPIRSD’s
C:Adjustingtimeandlux
L
N
load
CEFLAPIRSD
230 VAC
L
SL
Mains rated
retractive wall
switch
L
N
Switch / DIm
ballast input
SW
1
/AB
L
Nload
A few
CEFLAPIRSD
230 VAC
Mains rated
retractive wall
switch
L
SW
1
/AB
SL
Switch / DIm
ballast input
  • Page 1 1
  • Page 2 2

DANLERS CEFLA PIRSD Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI