Acroprint ES1000 User manual

Category
Wall clocks
Type
User manual

This manual is also suitable for

USER'S MANUAL
1
The details of this User's Manual are subject to change without previous notification.
This User's Manual has been prepared with the utmost care to cover all aspects of the time
recorder's use.
If you feel, however, that some explanations are inadequate, unclear, or difficult to
understand, please do not hesitate to contact Acroprint.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, mechanical, photocopying, recording or otherwise without
the written consent of Acroprint Time Recorder.
Place the time recorder at the position close to the wall outlet so that it is easily
accessible to disconnect.
1.
2.
3.
2
ALL RIGHTS RESERVED
©2004 ACROPRINT TIME RECORDER
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his or her own expense.
Caution: Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.
THIS DIGITAL APPARATUS DOES NOT EXCEED THE CLASS A LIMITS FOR RADIO NOISE EMISSIONS
FROM DIGITAL APPARATUS AS SET OUT IN THE RADIO INTERFERENCE REGULATIONS OF THE
CANADIAN DEPARTMENT OF COMMUNICATIONS.
LE PRÉSENT APPAREIL NUMÉRIQUE N'ÉMET PAS DE BRUITS RADIOÉLECTRIQUES DÉPASSANT LES
LIMITES APPLICABLES AUX APPAREILS NUMÉRIQUES DE CLASSE A PRESCRITES DANS LE
RÈGLEMENT SUR LE BROUILLAGE RADIOÉLECTRIQUE ÉDICTÉ PAR LE MINISTÈRE DES
COMMUNICATIONS DU CANADA.
WARNING
Precautions
This user's manual is prepared for safe and proper use of the unit.
Please follow all the instructions to avoid possible danger to yourself or
others and damage to the unit.
Signs
Various warnings and cautions are provided throughout this manual along with signs.
Remember each sign and its explanation listed below for your safety and proper
operation of the unit.
Caution
Warning
Improper handling may cause electric
shock DANGER.
DO NOT disassemble the unit.
"Don't" sign.
"Must-Do" sign.
Be sure to remove the line cord plug
from the outlet.
Do not disassemble the unit. There is a high voltage present inside, possibly leading to an
electric shock.
Do not use any voltage of the power source other than designated.
Do not share a single outlet with another plug. These may lead to fire or shock hazards.
Do not damage, break, or modify the power cord. Do not put a heavy object on, pull, or
forcefully bend the cord, either. These may damage the cord, possibly resulting in a fire or
electric shock.
If any anomaly occurs, for example, heat or smoke is generated or an odor is emitted, unplug
the unit immediately and contact your dealer for servicing. There is a danger that further use
may cause a fire or electric shock.
Do not modify the unit. Modifications may cause a fire and/or electric shock.
Warning
Improper handling may cause bodily accidents including
death and serious injury.
Improper handling may harm the human body or material.
3
1
1
If foreign matter should get in the unit (including a piece of metal, water, or liquid), disconnect
the plug from the outlet immediately and contact your dealer for servicing. There is a danger
that further use may cause a fire or electric shock.
Do not place the unit on an uneven or tilted surface. This may result in injuries due to the unit
dropping or falling off.
Do not put a water-filled container or a metal object on top of the unit. If water is spilled or the
metallic object slips inside, a fire or shock hazard may occur.
Do not place the unit near kitchen counter or humidifier. Oil, smoke, or steam generating from
them may cause fire or shock hazards.
Do not yank the power cord to disconnect from the outlet. Hold the plug with your hand to do
so, or the cord may be damaged, possibly leading to a fire or electric shock.
Remove the line cord plug from the outlet before transferring the unit, or it may damage the
cord, possibly leading to a fire or electric shock.
Make sure to insert the power plug as far as it will go. Improper insertion of the plug may
develop fire or shock hazards.
Do not insert or drop any other time card than specified into the slot. Such misuse may cause a
fire or electric shock.
If the unit should be dropped or the case be broken, unplug the unit and contact your dealer for
servicing. Further use may lead to a fire or shock hazard.
Be careful not to contact the print head, as you may get hurt or burned.
Do not install the unit in a humid or dusty environment. It may cause a fire or electric shock.
Do not plug or unplug the unit with a wet hand. You may get an electric shock.
Caution
4
2
2
Table of Contents
Introduction and Features of the ES1000
Getting Started
Unpacking the ES1000
Overview
Installing the Ribbon Cassette
Wall Mounting the ES1000
Where to Install the ES1000
Overview of Operation
What You Can Do with the ES1000
Settings
Preparation for Setting
Overview of Function Buttons
Setting the Hour Display Format
Setting the Time
Setting the Date
Setting Pay Period and Pay Period Ending Date
Monthly
Weekly
Bi-Weekly
Semi-monthly
Setting the Day Advance Time
Selecting the Print Format
Enabling Override and Transfer Functions
Selecting Rounding Rules
Schedule (Setting Calculation Rules)
Setting the Schedule
Free Zone or Open Shift (easy and most popular)
Time Zone or Fixed Shift
(ideal when everyone is on the same schedule)
Overtime Calculation
Round and Grace Time for Start/End Time (ST/ET)
Setting the Weekly Program for External Time Signal
Setting the Auto Daylight Saving Change
Selecting the Language
Setting the Password
1.
2.
3.
4.
1
2
2
2
3
5
5
6
7
11
11
12
13
14
15
16
16
17
18
19
20
21
22
23
25
26
26
30
37
42
45
48
52
53
5
Printing Hours Summary
Printing List of Active Card Numbers
Printing List of Program Settings
Additional Features
Override Printing
Card Transfer
Card Resetting
All Cards Resetting
Resetting
Installing the Optional Battery Backup
Connecting External Signal Control
Troubleshooting
Specifications
5
6.
7.
8.
9.
10.
11.
12.
13.
57
58
59
60
60
61
63
63
64
65
66
68
69
For accessories, visit Acroprint on-line
at www.acroprint.com or
call 800.334.7190 or (919) 872.5800 (outside the USA)
6
1. Introduction and Features of the ES1000
The ES1000 Totalizing Time Recorder provides fast, easy and accurate
calculations of your employee hours worked. The ES1000 can handle a
Weekly, a Bi-Weekly, a Semi-Monthly or a Monthly pay period for up to 100
employees. The recorder can be programmed to print late in or early out
punches in "RED". This state-of-the-art totalizing recorder offers a program for
an external signal (Bell/Horn, not included) and an optional full operational
battery back up for punching without AC power.
The ES1000 allows for the selection of two sets of calculating rules:
Free Zone or "Open Shift" rules permits employees to punch IN and OUT
without being assigned to a fixed schedule. Employee's times are calculated
using elapsed time or punched IN time subtracted from punched OUT time.
Using this selection is the easiest and most popular form of totalizing
employee's hours worked.
Free Zone allows for Auto Lunch deduction and permits you to select the
length of the break. You may also choose the number of regular hours worked
before overtime is calculated. You may also select the maximum hours an
employee is on the clock when it would be considered a "forgotten" out punch.
Using the Free Zone calculating rules will permit easy, accurate totalizing of
your payroll hours.
Time Zone or Fixed Schedule rules are designed for companies that have all
employees on one assigned shift. Time Zone rules allows for assignment of
"start" and "stop" times of the shift with GRACE times with early or late
punches printing in RED. Time Zone permits three break periods.
Time Zone rules may also be used with Free Zone rules under certain
circumstances. Taking advantage of all these advance features will require
additional programming time but will offer an advance time and attendance
system.
7
1
Overview
<Front view> <Back view>
2. Getting Started
Unpacking the ES1000
Operation Manual
Wall Mount Screws, Brackets
and Template
Ribbon Cassette
Keys
8
Wall-mounting holes
Front cover
Display
Function buttons
Key hole
Card slot
External signal and full
operation battery (optional)
compartment
2
Installing the Ribbon Cassette
1
Unlock cover and pull up the top
side of the card insertion slot and
pull it towards you.
2
Turn the knob on the cassette in the
arrow-indicated direction to make the
ribbon taut.
3
To insert the ribbon cassette inside
the unit, thread the ribbon between the
ribbon mask and the print head (See
drawing next page). Slide the clasps
on the lower side of the cassette into
projections on the unit.
Keep on pushing in the ribbon cassette
until the clasps at both sides catch and
the cassette snaps into position. If it is
difficult to insert the ribbon cassette,
try it while turning the knob.
Knob
Clasp
Clasp
Print head
Make sure the power is on before installing.
9
Front Cover
Projection
3
Take the following precautions when inserting a new ribbon cassette.
Install the ribbon cassette so that the ribbon is between the
print head and the
ribbon mask (see the figure on the left). Printing failure may occur if the ribbon is
placed behind the ribbon mask (see the figure below).
4
Precautions to take when replacing the ribbon
65
Replace the cover by fitting the tabs at
the bottom of the cover into the holes
located on the clock.
Then close the cover letting it snap
into place.
Turn the knob of the ribbon cassette in
the counter clockwise to tighten the
ribbon.
Print head
Ribbon mask
Ribbon
Print head
Ribbon mask
Ribbon
10
4
Correct Incorrect
Wall Mounting the ES1000
The ES1000 may be platform or wall mounted using the wall mount screws supplied.
To mount unit on wall, take the following steps:
The supplied screws
are intended for use
on a thick wooden
wall or wooden
column. Do not use
them on any other
materials. There is
a danger that the
unit may come off if
used on other
materials.
Install wall mount screws (supplied) into a wall 3.94 inches (10 cm) apart.
Be sure to keep about 0.12 inch ( 3 mm) of the screw head out of the wall.
You can use a supplied template to fix position of two screws.
Where to Install the ES1000
Avoid placing the unit in environments that are:
• humid or dusty
• exposed to direct sunshine
• subject to frequent or continuous vibrations
• outside the temperature range between -5˚ and 45˚ C (23˚ to 113˚F)
• affected by chemicals or ozone
Mount the wall mount
brackets as shown on the
right.
1
2
11
5
0.12"(3mm)
3.94" (10cm)
Wall Mount Template
Wall
Screws
Once the AC line cord is plugged into the outlet, the unit can be used immediately. Basic
operations, including the time and ending dates, are preset.
The ES1000 is designed to work only with the ES1010 Time Cards. The clock will not
function correctly using other style time cards, and using other cards may cause damage to
sensors.
Do not let any metallic object get into the slot, including paper clips. Do not
forcefully push in a card, either. These may cause the unit to malfunction.
3. Overview of Operation
It is easy to operate the unit. Just insert a time card. To start a time card, make sure the
"number" on the card faces outward (towards operation). The card is then automatically
pulled in, printed and then ejected.
When a new card is inserted, the card will automatically be registered, and will print the
"IN" print on the first line. The month will be printed on the first line also or on the line
when the month and printing line change.
You can print "IN" and "OUT" as many times as you want per day. Concerning the printing
line, it will slide one line down each time you insert the card for "IN" print.
The recorder will record the last imprint and automatically switch the "IN" and "OUT".
You may also manually switch the column position of imprint by pushing the "IN" button
or "OUT" button.
The number of cards that can be automatically registered is a maximum of 100 cards.
Card numbers 001 through 100 using duplicate numbers can cause incorrect totals.
See "2. Getting Started".
Even if the "IN" is printed, when the present time passes the "Day Advance Time", it will
consider that the "OUT" print was forgotten and will print the "IN" print on the next line.
12
6
Schedule [Time Zone Rule]
You can select days of the week which your desired schedule is applied to. All other days of
the week will be regarded as "weekend or non-scheduled work days", which you can set
threshold hours and duration of auto break deduction.
Based on the programmed schedule, you can regulate the day's working rules. The day's
partition that is the schedule's standard is the "Day advance time", and this time is selectable.
[Applicable days of the week]
Example: From Monday to Friday
What You Can Do With the ES1000
13
7
IN
Day
advance
time
red red red
7:30 a.m.
START
8:00 a.m. 1:00 p.m.12:00 p.m. 3:15 p.m.3:00 p.m.
END
5:00 p.m.
02 Start time for
irregular printing
(black red)
Break time 1 Break time 2
Day
advance
time
Printed
in black
* Any punch during "break time" will be printed in black regardless of settings.
* Break time will be deducted from worked hours automatically.
Printed
in black
(If you set the Break #3, set 14 and 15 also.)
* All punches are printed in black.
Note: Numbers in square mean program numb
er.
[Non-selected days of the week]
Example: Saturday and Sunday
16 Threshold hours for auto
break deduction
17 Duration of
break time
Worked more
than 4 hours
Break time
(= 30 min.)
Worked hours
( = 4 hours)
Worked hours
03 End time for
irregular printing
(red black)
OUT
5:05 p.m.
IN
8:30 a.m.
OUT
3:30 p.m.
12 Start time
of Break #2
10 Start time
of Break #1
13 Duration in
minutes,
Break #2
11 Duration in
minutes,
Break #1
In addition to the start time and duration for the maximum settings of three "break times",
the following settings are available to fulfill your needs.
Start and End Time for Irregular (Red) Printing
Once you set the schedule for irregular printing, printing color automatically changes
according to the start/end time you've set. Color change makes it possible to easily see an
employee's late in or early out.
* Note: Any punch during break time will be printed in black regardless of the above setting.
Regular Hours and Overtime
You can select calculation type from the following four choices according to how to divide
and calculate "regular hours" and "overtime" when you selected "time zone" rule.
Semi-monthly and Monthly pay period overtime calculations are based on daily overtime
only. To assure accurate calculations for these pay periods, please select daily regular hours
limit as desired, and select " " as the limit for weekly regular hours. This will "disable"
the weekly OT function so that the clock will calculate properly.
[Type 1]
Basically all worked hours are accumulated as regular hours.
14
8
IN OUT RH OT OTRH
Au Mo 9:00A Mo 6:00P
Tu 8:00P
8:00
Tu 9:00A
8:00
We 6:00P
We 9:00A
8:00
Th 7:00P
Th 9:00A
8:00
Daily Total
8:00
16:00
24:00
32:00
2:002:00
2:00
3:001:00
IN OUT RH OT OTRH
Au Mo 9:00A Mo 6:00P
Tu 8:00P
8:00
Tu 9:00A
10:00
We 10:00P
We 9:00A
12:00
Th 6:00P
Th 9:00A
8:00
Daily Total
8:00
18:00
30:00
38:00
Fr 7:00P
Fr 9:00A
9:00
47:00
[Type 2]
Example: Daily regular hours: 8 hours/day, Break time: start =12:00 & 60 min./day
You must set limit of regular working hours per day (e.g. 8 hours per day).
All worked hours, which exceed the limit, will be accumulated as overtime.
In this case, "regular hours" and "overtime" will be accumulated separately.
[Type 3]
Example: Pay Period: Weekly, Total regular hours: 40 hours/week
Break time: start =12:00 & 60 min./day
15
9
You must set limit of regular hours per week (e.g. 40 hours per week).
All worked hours shall be accumulated as regular hours until it reaches the limit. Once it
goes over the limit, then, the rest of worked hours shall be accumulated as "overtime".
[Type 4]
Example: Pay Period: Weekly, Daily regular hours: 8 hours/day, Total regular
hours: 40 hours/week, Break time: start =12:00 & 60 min./day
If you set limits for both "Daily regular hours" (Daily OT) and "Total regular hours"
(Weekly OT), then daily worked hours shall be calculated based on the rules for "Daily
regular hours", and will take precedence over the weekly setting. If you want "Total
regular hours" to be the deciding calculation for OT, then set Daily limits to " ".
If you set neither the limit for "Daily regular hours" nor "Total regular hours", all
worked hours shall be accumulated as regular hours.
IN OUT RH OT OTRH
Au Mo 9:00A Mo 6:00P
Tu 8:00P
8:00
Tu 9:00A
8:00
We 10:00P
We 9:00A
8:00
Th 6:00P
Th 9:00A
8:00
Daily Total
8:00
16:00
24:00
32:00
2:002:00
6:00
6:00
4:00
Fr 7:00P
Fr 9:00A
8:00
40:00 7:001:00
IN OUT RH OT OTRH
Au Mo 9:00A Mo 6:00P
Tu 8:00P
8:00
Tu 9:00A
10:00
We 10:00P
We 9:00A
12:00
Th 6:00P
Th 9:00A
8:00
Daily Total
8:00
18:00
30:00
38:00
Fr 7:00P
Fr 9:00A
9:00
40:00 7:00
Priority Rule to the Days Not Scheduled in the Time Zone
Schedule
By selecting "calculation priority" setting, weekend or non-scheduled work days' worked
hours can be always regarded and accumulated as "Overtime" prior to other rules. If you
don't select this setting, weekend or non-scheduled work days' worked hours will be
accumulated in accordance with setting for the calculation type.
Example: Pay Period: Weekly, Total regular hours: 40 hours/week
Break time: start =12:00 & 60 min./day, Calculation priority = Selected
16
10
Round and Grace Time for Start and End Time
Under time zone rules of calculation, you can set round and grace time for Start Time (ST)
and End Time (ET). Once you set Round Time for ST and ET, the time for calculation will
be rounded forward to ST even if a person arrives earlier than ST and back to ET even if
he/she leaves the office later than ET.
By setting of Grace Time for ST and ET, the time for calculation will be rounded back to ST
even if a person arrives later than ST and forward to ET even if he/she leaves the office
earlier than ET. You can set up to 99 minutes at maximum for round/grace time.
IN and OUT punches during the grace period are printed in black but, you can also set red
printing for any punch during this period in black or red.
Grace Back
Time Zone
Grace Forward
Time Zone
Calculated Worked Hours
ST ET
Round Forward
Time Zone
Round Back
Time Zone
Calculated Worked Hours
ST ET
IN OUT
IN OUT
IN OUT RH OT OTRH
Au Mo 9:00A Mo 6:00P
Tu 7:00P
8:00
Tu 9:00A
9:00
We 12:00P
We 9:00A
3:00
Th 6:00P
Th 9:00A
8:00
Daily Total
8:00
17:00
20:00
28:00
Fr 7:00P
Fr 9:00A
9:00
37:00
Sa 5:00P
Sa 13:00A
4:004:00
Preparation for Setting
Caution: If time cards were punched prior to original settings or if you wish to change Pay
Periods or when the Day Advances or change the Minute print format you will need to reset
ALL Time Cards. Please refer to the ALL Cards Resetting section under Additional Features.
Removing and replacing front cover.
Make sure the power is on before making setting.
1 Unlock the cover.
Hold the sides of the cover with both
hands and pull it toward you.
2
Once you push the [SETTING
START/END] button, display will be
as shown in the following figure.
Then, push the control button for two
seconds and you can go into the
setting mode.
3 Make settings using the control button
while watching the display.
Please refer to the following pages for
the details of each setting.
4
After setting has been completed, fit
the tabs at the lower sides of the cover
into the holes of the unit. Then, fit
another set of tabs at the top sides of
the cover into the holes of the unit.
4. Settings
Tabs
Holes
Holes
17
11
Function
buttons
button
Display
Front Cover
SETTING START/END
Key
With the front cover off, you will be able to access program buttons.
[SETTING START/END] button
Push this button when you go into/get out of the setting mode.
[DATE/TIME] button
Use the [DATE/TIME] button when you want to change the date and/or time. You can select
the desired setting mode by pushing this button. (Make sure to push it for 2 seconds before
going into the setting mode.)
[FUNCTION] button
Use the [FUNCTION] button when you want to change the pay period, print format, and so
on. You can select the desired setting mode by pushing this button. (Make sure to push it for
2 seconds before going into the setting mode.)
[+] or [-] button
When you push the [+] or [-] button, you can change the set value.
[SET] button
You can set the value selected on the display by pushing the [SET] button.
Over View of Function Buttons
18
12
[SETTING START/END] Button
Function Buttons
Push the [SETTING START/END] button before you start setting. At that moment,
" " is shown on a display and you go into setting mode.
Setting the Hour Display Format
1
Push the [DATE/TIME] button for 2
seconds.
3
Push the [+] or [-] button to select
either "AM/PM" or "24 hour". For
example, set 1 if "AM/PM" is desired.
4
Push the [SET] button to finish the
setting. At that moment, the display
will change from flashing to steady,
and the setting is now completed.
5
Push the [SETTING START/END]
button to get out of setting mode. Or
press the [DATE/TIME] function
button to set the time.
Make sure "date" and "time" are
indicated on the display and the
colon is flashing. Then replace the
cover and lock.
2
Once a number on the display starts
flashing, make sure the " " mark
is located under the "DISPLAY
HOURS" mark.
DISPLAY
HOURS
19
13
SET
DATE/TIME
1 AM/PM
2 24hour
DISPLAY
HOURS
SET
DATE/TIME
AM
Colon
Date
Push the [SETTING START/END] button before you start setting. At that moment,
" " is indicated on a display and you go into setting mode.
Example Change the time from 10:08 to 10:09.
Setting the Time
1
Push the [DATE/TIME] button for 2
seconds.
3
In case of the example, push the
[SET] button because the hour is
not to be changed. Now the hour of
10 o'clock has been set. At that
moment, the flashing of the display
will change from "Hour" to
"Minute".
4
Push the [+] or [-] button to change
"minute". In case of the example,
push [+] button to change the
minute from 08 to 09.
5
Push the [SET] button to finish the
setting. At that moment, the display
will change from flashing to steady,
and the setting is now completed.
6
Push the [SETTING START/END]
button to get out of setting mode. Or
press the [DATE/TIME] function
button to set the date.
Make sure "date" and "time" are
indicated on the display and the
colon is flashing. Then replace the
cover and lock.
2
Once a number on the display starts
flashing, position the " " mark
under the "TIME" mark by pressing
the [DATE/TIME] button.
A flashing number can be changed.
20
14
SET
DATE/TIME
TIME
SET
DATE/TIME
TIME
SET
DATE/TIME
TIME
SET
DATE/TIME
AM
AM
AM
AM
AM
TIME
Minute
Second
Hour
Date
Colon
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Acroprint ES1000 User manual

Category
Wall clocks
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI