EFLOW4N

Altronix EFLOW4N Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Altronix EFLOW4N Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Input:
• 120VAC,60Hz,3.5amp.
• Inputfuse:5A/250V.
Output:
• 12VDCor24VDCselectableoutput.
•12VDCor24VDC@4.0ampsupplycurrent.
• Power-limitedoutput.
• Auxiliarypower-limitedoutput
rated@1amp(unswitched).
• OverVoltageProtection.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltypebatteries.
• Maximumchargecurrent1.54amp.
• Automaticswitchovertostand-bybatterywhen
ACfails.Transfertostand-bybatterypoweris
instantaneouswithnointerruption.
Supervision:
• ACfailsupervision(form“C”contacts).
• Batteryfail&presencesupervision
(form“C”contacts).
• Lowpowershutdown.ShutsdownDCoutputterminals
ifbatteryvoltagedropsbelow71-73%for12Vunits
and70-75%for24Vunits(dependingonthepower
supply).Preventsdeepbatterydischarge.
Fire Alarm Disconnect:
• SupervisedFireAlarmdisconnect(latchingor
non-latching)10KEOLresistor.Operatesona
normallyopen(NO)ornormallyclosed(NC)trigger.
Electrical:
• Operatingtemperature:0ºCto49ºCambient.
• BTU/Hr.:
12VDC:24.57BTU/Hr.
24VDC:49.15BTU/Hr.
• SystemACinputVArequirement:420VA.
Visual Indicators:
• GreenACPowerLEDindicates120VACpresent.
• ACinput,DCoutputandBatteryLEDindicators.
Additional Features:
• Shortcircuitandoverloadprotection.
• Unitiscompletewithpowersupply,enclosure,
batteryleadsandcamlock.
Mechanical:
• EnclosureDimensions(HxWxDapprox.):
13.5”x13”x3.25”(342.9mmx330.2mmx82.55mm)
- Accommodatesuptotwo(2)12VDC/7AHbatteries.
• Productweight(approx.):6.55lbs.(2.97kg).
• Shippingweight(approx.):7.45lbs.(3.38kg).
Specifications
eFlow4Nisapowersupply/chargerthatconvertsa115VAC,60Hzinputintoasingle
12VDCor24VDCpower-limitedoutput.
eFlow4N
Power Supply/Charger
Rev.DSeFlow4N_10242013
Overview
Agency Approvals
UL294 ULListedforAccessControl
SystemUnits.
UL603 ULListedforPowerSupplies
forUsewithBurglar-Alarms
Systems.
UL1481 ULListedforPowerSupplies
forFireProtectiveSignaling
Systems.
ULC-S318-96-PowerSuppliesfor
BurglarAlarmSystems.Alsosuitablefor
AccessControl.
CSFM-CaliforniaStateFire
MarshalApproved.
Altronix Corp.
140 58th St. Brooklyn, NY
CE-EuropeanConformity
eFlow4N
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
1.40
(36mm)
1.40”
(36mm)
4.85
(123mm)
4.85
(123mm)
1.40
(36mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
13.0”
(330mm)
5.10”
(130mm)
6.5625”
(167mm)
1.20
(31mm)
1.20”
(31mm)
1.20”
(31mm)
3.25
(83mm)
3.25”
(83mm)
3.25
(83mm)
3.25”
(83mm)
1.0”
(25mm)
1.0”
(
25mm
)
10.5
(
267mm
)
1.0”
(
25mm
)
1.0”
(25mm)
0.75
(19mm)
0.75”
(19mm)
0.9375”
(24mm)
0.9375”
(24mm)
11.0
(279mm)
12.5
(318mm)
Enclosure Dimensions (H x W x D approximate):
13.5”x13”x3.25”(342.9mmx330.2mmx82.55mm)
/