Emerson 539031G10 Datasheet

Category
Power cables
Type
Datasheet
AC Power
For Business-Critical Continuity™
Emerson Network Power Rack PDU Systems
Product Selection Guide - North American Models
i
TABLE OF CONTENTS
1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.1 Safety and Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION . . . . . . . . . . . . . . . . . . .2
3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS. . . . . . . . . . . . . . . . .3
3.1 Overview - Basic Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Basic Rack PDU Optional Cord Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.3 Dimensional Drawings - Basic Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS . . . . . . . . . . . . . . .27
4.1 Overview - Managed Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.2 Specifications - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.3 Model Number Configuration - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints . . . . . . . . . . . . . . . . . . . . . . 30
4.5 Dimensional Drawings - Managed Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.0 LIEBERT MPX - ADAPTIVE RACK PDUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
5.1 Overview - Adaptive Rack PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.2 MPX PRC (Power Rail Chassis). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) . . . . . . . . . . . . . . . . . 36
5.4 MPX BRM (Branch Receptacle Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.5 Adaptive Rack PDU Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.5.1 Cord Sets and Cable Restraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.5.2 Liebert RPC
(RPC-1000) and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.5.3 Part Numbers for Liebert RPC and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5.5.4 Ports on the Liebert RPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5.5.5 Liebert RPC Capabilities and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.5.6 RPC BDM—Basic Display Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5.5.7 Temperature/Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
6.1 STEP 1 - Select an MPX PRC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
6.3 STEP 3 - Select an MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.4 STEP 4 - Select Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.5 System Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.6 Specifications for Liebert MPX Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
6.7 Dimensional Drawings - Adaptive Rack PDUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
ii
FIGURES
Figure 1 Knurr DI-STRIP 35351011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 2 Knurr DI-STRIP 35351021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 3 Knurr DI-STRIP 35351031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 Knurr DI-STRIP 35351041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 5 Knurr DI-STRIP 35351051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 6 Knurr DI-STRIP 35351061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 7 Knurr DI-STRIP 35351081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 8 Knurr DI-STRIP 35352011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 9 Knurr DI-STRIP 35352021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 10 Knurr DI-STRIP 35352031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 11 Knurr DI-STRIP 35352041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 12 Knurr DI-STRIP 35352051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 13 Knurr DI-STRIP 35352061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 14 Knurr DI-STRIP 35352078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 15 Knurr DI-STRIP 35353011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 16 Knurr DI-STRIP 35353021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 17 Knurr DI-STRIP 35353031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 18 Knurr DI-STRIP 35353041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 19 Knurr DI-STRIP 35353051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 20 Knurr DI-STRIP 35353061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 21 Knurr DI-STRIP 35353078 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 22 Knurr DI-STRIP 35353088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 23 Liebert MPH rack mount power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 24 Liebert MPH vertical power strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 25 Liebert MPX 1880 and 1035 models and components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 26 MPX PRC (Power Rail Chassis) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 27 Liebert RPC ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 28 RPC BDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 29 Temperature/humidity sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 30 Liebert MPX MPXPRC-1035mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 31 Liebert MPX MPXPRC-1880mm mixed modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
TABLES
Table 1 Specifications - Knurr DI-STRIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 2 Cord sets - Knurr DI-STRIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 3 Specifications - Liebert MPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 4 Cord sets and cable restraints - Liebert MPH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Table 9 Specifications - MPX BRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Emerson Network Power Rack PDU Systems
1
1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS
Emerson Network Power’s Rack PDU Systems is a family of products that delivers power and man-
agement to connected IT equipment through a global and comprehensive offering including Basic,
Managed and Adaptive Rack PDU systems.
Each PDU type offers simplified installation and easy operation. Each type is compatible with
standard rack enclosures. These Emerson Rack PDUs provide easy low-cost installation, simple
relocation, security and proven design and performance.
Emerson Rack PDUs can be set up with varying degrees of power-monitoring and management.
When power or management requirements grow, the adaptive PDUs are scalable, enabling them to
grow with the installation.
Emerson PDUs are available for the entire spectrum of power needs of every type of rack equipment.
Knurr
®
DI-STRIP
-
Basic Rack PDU systems, provide a broad range of power distribution capac-
ities and connectivity solutions in a robust package.
Liebert MPH
-
Managed Rack PDUs with single-phase or three-phase capability for fixed power
input/output with remote management support; one-piece unit with monitoring at the branch
level and control at the receptacle level; available in rack-mount and zero U configurations.
Liebert MPX
-
Adaptive Rack PDUs built with modular and scalable components that can be
installed and reconfigured on-site to meet changing input and output power connectivity needs;
with remote monitoring at the branch level and receptacle management and control at the recep-
tacle level.
1.1 Safety and Agency Compliance
Where a conflict arises between the following documents and statements made herein, the statements
in this specification will govern.
North American Units - 120V and 208V (Single-Phase and Three-Phase)
UL 60950-1 Information Technology Equipment
CAN/CSA-C22.2 No. 60950-1-03 Information Technology Equipment
FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C63.4
ISTA Procedure 1A and 2A
RoHS Compliant
Determining the Right Emerson PDU for Your Application
2
2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION
Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, high-
capacity, rack-mounted equipment. Determining which is best for a particular installation requires
knowing the basic power requirements of the equipment in the rack, deciding on the acceptable or
preferable level of monitoring and control and then balancing those considerations against site
requirements.
The Emerson Rack PDU product line includes models to fit all types of installations: new or estab-
lished; stable or rapidly changing; contracting or expanding. Each type of installation may require
any or all types of Emerson Rack PDUs.
After determining your requirements, refer to the data and specifications for each product.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
3
3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS
3.1 Overview - Basic Rack PDUs
The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capaci-
ties and connectivity solutions in a robust package.
The Knurr DI-STRIP includes an input power cord with appropriate input plug connection and
hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions
are also provided. Knurr DI-STRIP Rack PDUs are available in rack mount and vertical zero-U form
factors.
The Knurr DI-STRIP fits most standard 600mm width network equipment rack enclosures. Product
fit should be confirmed for each application.
Table 1 Specifications - Knurr DI-STRIP
Part
Number
INPUT OUTPUT
Form
FactorVoltage
Rated
Amps
Max
Continuous
Amps kW* Phase Plug
Receptacle/Socket
Configuration
035351011 120 15 12 1.4 1 NEMA 5-15P (9) NEMA 5-15R
Rack mount
or Vertical
035351021 120 15 12 1.4 1 NEMA 5-15P (12) NEMA 5-15R Vertical
035351031 120 15 12 1.4 1 NEMA 5-15P (18) NEMA 5-15R Vertical
035351041 120 20 16 1.9 1 NEMA L5-20P (9) NEMA 5-20 T-Slot Vertical
035351051 120 20 16 1.9 1 NEMA 5-20P (12) NEMA 5-20 T-Slot Vertical
035351061 120 20 16 1.9 1 NEMA L5-20P (12) NEMA 5-20 T-Slot Vertical
035351081 120 30 24 2.8 1 NEMA L5-30P (24) NEMA 5-20 T-Slot Vertical
035352011 208-240 20 16 3.3 1 NEMA L6-20P (9) IEC-C13 sockets Vertical
035352021** 208-240 20 16 3.3 1 IEC-C20 inlet (9) IEC-C13 sockets
Rack mount
or Vertical
035352031 208-240 20 16 3.3 1 NEMA L6-20P (12) IEC-C13 sockets Vertical
035352041** 208-240 20 16 3.3 1 IEC-C20 inlet (12) IEC-C13 sockets Vertical
035352051 208-240 30 24 4.9 1 NEMA L6-30P (4) IEC-C19 sockets Vertical
035352061 208-240 30 24 4.9 1 NEMA L6-30P (24) IEC-C13 sockets Vertical
035352078 208-240 30 24 4.9 1 NEMA L6-30P
(20) IEC-C13 +
(4) IEC-C19 sockets
Vertical
035353021 120/208 20 16 5.7 3 NEMA L21-20P
(18) IEC-C13 +
(6) IEC-C19 sockets
Vertical
035353031 120/208 20 16 5.7 3 NEMA L21-20P
(27) IEC-C13 +
(6) IEC-C19 sockets
Vertical
035353041 120/208 20 16 5.7 3 NEMA L21-20P (27) 5-20 T-Slot Vertical
035353011 120/208 30 24 8.6 3 NEMA L21-30P (6) IEC-C19 sockets Vertical
035353051 120/208 30 24 8.6 3 NEMA L21-30P
(18) IEC-C13 +
(6) IEC-C19 sockets
Vertical
035353061 120/208 30 24 8.6 3 NEMA L21-30P
(27) IEC-C13 +
(6) IEC-C19 sockets
Vertical
035353078 208-240 60 48 17.3 3
IEC60309
(3 pole, 4 wire,
250VAC, blue)
(42) IEC-C13 +
(6) IEC-C19 sockets
Vertical
035353088 208-240 42 34 24.4 3
(2) IEC60309
(3 pole, 4 wire,
250VAC, blue)
(42) IEC-C13 +
(6) IEC-C19 sockets
Vertical
All input cords are 10 ft. (3m) in length.
* Formulas used to calculate the kW:
For single-phase: input voltage x max continuous amps = watts
For three-phase: input voltage x max continuous amps x 1.73 = watts
** Knurr DI-STRIP output expansion modules require the use of a cord set for input power.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
4
3.2 Basic Rack PDU Optional Cord Sets
Output Cord Sets
Output cord sets are available to support conversion of Rack PDU power output receptacles to alter-
native power output connections and to support Rack PDU output expansion capabilities.
Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles.
The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle,
a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include:
IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment
plugs.
Knurr DI-STRIP output expansion modules are powered via an IEC-C20 input connection. These
systems provide output expansion capabilities when connected to a receptacle on a separate Rack
PDU. The output cord set for these systems includes an IEC-C19 receptacle to connect to the IEC-C20
plug on the output expansion Knurr DI-STRIP, a 3 ft. (1m) power cord and plug to connect to the
Rack PDU receptacle providing power. Available plugs include: IEC-C20 to connect to an IEC-C19
Rack PDU receptacle.
Input Cord Sets
Input cord sets are available to support conversion of Rack PDU power input connections to
alternative power input connections. Conversion of power input can be provided on Rack PDUs with
L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P
Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug.
Table 2 Cord sets - Knurr DI-STRIP
Cord Sets
Output Cord Sets - Power Output Conversion
539031G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m)
539031G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m)
539031G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m)
539031G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m)
Output Cord Sets - Power Output Expansion
539031G7 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 3 ft. (1m)
539031G8 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 10 ft. (3m)
539031G3 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 3 ft. (1m)
539031G4 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 10 ft. (3m)
Input Cord Sets - Power Input Conversion
539031G12 Input Cord Set - Power Input Conversion - L5-20R to 5-20P, 1 ft. (0.3m)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
5
3.3 Dimensional Drawings - Basic Rack PDUs
Figure 1 Knurr DI-STRIP 35351011
03.535.101.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
12.2" (311mm)
2.9"
(73mm)
2.5"
(63mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
35351011
Rev. 3
Input
Cord
Input
Plug Phase
Rated
Amps
Voltage
(VAC)
5-15P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
5-15P 120 15112
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
OUTPUT POWER
1 5-15R (9) 120 12112
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 2.5 lb. (1.1kg)
3. Shipping dimensions:
18.9" (480mm) L x 2.8" (71mm) W x 3.3" (84mm) D
4. Shipping weight: 2.8 lb. (1.3kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
17.6" (447mm)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
6
Figure 2 Knurr DI-STRIP 35351021
03.535.102.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
19.6" (497mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
12.2" (311mm)
4.8"
(123mm)
2.5"
(63mm)
35351021
Rev. 3
Input
Cord Phase
Rated
Amps
5-15P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
5-15P 120 15112
OUTPUT POWER
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 5-15R (9) 120 12112
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 2.7 lb. (1.2kg)
3. Shipping dimensions:
22.2" (565mm) L x 2.8" (70mm) W x 3.3" (85mm) D
4. Shipping weight: 3.1 lb. (1.4kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Input
Plug
Voltage
(VAC)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
7
Figure 3 Knurr DI-STRIP 35351031
03.535.103.1
00/00 000000
www.knuerr .com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
27.4" (697mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
5-15P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
5-15P 120 15112
OUTPUT POWER
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 5-15R (18) 120 12112
35351031
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
27.4" (697mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3.3 lb. (1.5kg)
3. Shipping dimensions:
42" (1065mm) L x 2.4" (60mm) W x 3" (75mm) D
4. Shipping weight: 3.8 lb. (1.72kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Input
Plug
Voltage
(VAC)
12.2" (311mm)12.7" (323mm)
2.5"
(63mm)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
8
Figure 4 Knurr DI-STRIP 35351041
03.535.104.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
17.6" (447mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
L5-20P
(2 pole, 3 wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
L5-20P 120 20116
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
OUTPUT POWER
1 5-20R (9) 120 16116
35351041
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3 lb. (1.35kg)
3. Shipping dimensions:
26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D
4. Shipping weight: 3.4 lb. (1.54kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Input
Plug
Voltage
(VAC)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
9
Figure 5 Knurr DI-STRIP 35351051
03.535.105.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
19.6" (497mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
5-20P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
5-20P 120 20116
OUTPUT POWER
12.2" (311mm)
4.8"
(123mm)
2.5"
(63mm)
Input
Plug
Voltage
(VAC)
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 5-20R (9) 120 16116
35351051
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3.5 lb. (1.57kg)
3. Shipping dimensions:
26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D
4. Shipping weight: 3.9 lb. (1.76kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
10
Figure 6 Knurr DI-STRIP 35351061
03.535.106.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
19.6" (497mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
L5-20P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
L5-20P 120 20116
OUTPUT POWER
12.2" (311mm)
4.8"
(123mm)
2.5"
(63mm)
Input
Plug
Voltage
(VAC)
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 5-20R (12) 120 16116
35351061
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3.2 lb. (1.47kg)
3. Shipping dimensions:
24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D
4. Shipping weight: 3.5 lb. (1.6kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
11
Figure 7 Knurr DI-STRIP 35351081
03.535.108.1
00/00 000000
www.knuerr. com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STR IP
24.5" (622mm)16.6" (422mm)
2.1"
(53mm)
Branch
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BranchVoltage (VAC)
Max. Cont. Amps
1 5-20R (12) 120 16120
2 5-20R (12) 120 16120
35351081
Rev. 4
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
43.2" (447mm) L x 1.7" (44mm) W x 3.3" (85mm) D
2. Unit weight: 7.51 lb. (3.4kg)
3. Shipping dimensions:
44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (160mm) D
4. Shipping weight: 8.4 lb. (3.8kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
43.2" (1097mm)
FRONT VIEW
20A branch circuit breakers
Branch 2Branch 1
20A branch
circuit breakers
REAR VIEW
SIDE VIEW
1.7"
(44mm)
1.8"
(46mm)
3.3"
(85mm)
Input
Cord Phase
Rated
Amps
L5-30P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
L5-30P 120 30124
OUTPUT POWER
Input
Plug
Voltage
(VAC)
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
12
Figure 8 Knurr DI-STRIP 35352011
03.535.201.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
17.6" (447mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
L6-20P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
L6-20P 208-240 20116
OUTPUT POWER
Input
Plug
Voltage
(VAC)
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 IEC-C13 (9) 208-240 12116
35352011
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3.2 lb. (1.4kg)
3. Shipping dimensions:
24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D
4. Shipping weight: 3.4 lb. (1.5kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
13
Figure 9 Knurr DI-STRIP 35352021
03.535.202.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BAS IC
DI STRIP
17.6" (447mm)
2.5" (63mm) 12.2" (311mm) 2.9" (73mm)
IEC-C20 inlet
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Input Phase
Rated
Amps
Voltage
(VAC)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
208-240 20116
OUTPUT POWER
* Requires a cordset
IEC-C20
Inlet *
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1 IEC-C13 (9) 208-240 12116
35352021
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 1.5 lb. (0.7kg)
3. Shipping dimensions:
19" (483mm) L x 3" (75mm) W x 2.4" (60mm) D
4. Shipping weight: 1.7 lb. (0.8kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
14
Figure 10 Knurr DI-STRIP 35352031
03.535.203.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
19.6" (497mm)
2.5" (63mm)12.2" (311mm)4.8" (123mm)
FRONT VIEW
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
L6-20P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
L6-20P 208-240 20116
OUTPUT POWER
Input
Plug
Voltage
(VAC)
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1
IEC-C13 (12)
208-240 12116
35352031
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 3.4 lb. (1.5kg)
3. Shipping dimensions:
26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D
4. Shipping weight: 3.7 lb. (1.68kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
15
Figure 11 Knurr DI-STRIP 35352041
03.535.204.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
Input
Plug
Voltage
(VAC)
Bank
Receptacle
Type (Qty)
Receptacle Type
Phase Per Receptacle Per BankVoltage (VAC)
Max. Cont. Amps
1
IEC-C13 (12)
208-240 12116
35352041
Rev. 3
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit dimensions:
19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D
2. Unit weight: 1.8 lb. (0.8kg)
3. Shipping dimensions:
22.6" (575mm) L x 2.4" (60mm) W x 3" (75mm) D
4. Shipping weight: 2.1 lb. (0.9kg)
5. All wiring is to be in compliance with national
and local electric codes.
6. Mounting provisions provided.
19.6" (497mm)
12.2" (311mm) 2.5" (63mm)4.8" (123mm)
FRONT VIEW
IEC-C20 INLET
REAR VIEW
SIDE VIEW
1.7"
(44mm)
2"
(50mm)
Input
Cord Phase
Rated
Amps
Max. Cont.
Amps
INPUT POWER
10 ft.
(3m)
IEC-C20
inlet *
208-240 20116
OUTPUT POWER
* Requires a cordset
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs
16
Figure 12 Knurr DI-STRIP 35352051
03.535.205.1
00/00 000000
www.knuerr.com
120 VAC, 60Hz
Input: max. 15A
Outlets: max. 15A
NA BASIC
DI STRIP
17.6" (447mm)
FRONT VIEW
20A branch circuit breaker
Branch 2
Branch 1
20A branch
circuit breaker
REAR VIEW
SIDE VIEW
1.7"
(44mm)
1.8"
(46mm)
3.3"
(85mm)
35352051
Rev. 3
Input
Cord
Input
Plug
Phase
Rated
AmpsVoltage
Voltage (VAC)
L6-30P
(2-pole, 3-wire)
Max. Cont.
Amps
INPUT POWER
10 ft. (3m)
L6-30P 208-240 30124
Receptacle Type
(Quantity)
Per Receptacle Type
Per Receptacle
Per Branch
Phase
Branch
Max. Continuous Amps
OUTPUT POWER
IEC-C19 (2)
208-240
208-240
1
1
1
2
16
16
20
20
AGENCY:
CSA tested to UL 60950-1
RoHS compliant (reduction of hazardous substances)
ENVIRONMENTAL:
Operating: 32°F to 131°F (0°C to 55°C), 5% - 95% RH
non-condensing, non-corrosive
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
NOTES:
1. Unit Dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2.0" (50mm) D
2. Unit Weight: 4.8lb. (2.2kg)
3. Shipping Dimensions: 29.0" (740mm) L x 6.3" (160mm) W x 2.7" (70mm) D
4. Shipping Weight: 5.5lbs (2.5kg)
5. All wiring is to be in compliance with national and local
electric codes.
6. Mounting provisions provided.
IEC-C19 (2)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51