Configuration
The MicroPOD plugs into the utility
and UPS, and the UPS is plugged
into the MicroPOD. All protected
devices are connected to the
MicroPOD, allowing maintenance
bypass for the UPS.
MicroPOD
™
S
pecifications
R
eceptacle to Plug to MicroPOD
P
art Number Plug to Utility UPS Input UPS Output Output Receptacles
120V UL L
isted MicroPODs
MP2-115A
5-15P 5-15R 5-15P (8)5-15R
MP2-120C 5-20P 5-20R 5-20P (8)5-20R (T-Slot)
MP2-130C
L5-30P L5-30R L5-30P (8)5-20R (T-Slot)
MP2-130E L5-30P L5-30R L5-30P (2)5-15R, (4) 5-20R (T-Slot)
(1) L5-30R
MP2-130P
L5-30P L5-30R L5-30P (4) 5-15R, (2) L5-20R
MP2-115HW Hardwired 5-15R 5-15P Hardwired
MP2-120HW
Hardwired 5-20R 5-20P Hardwired
MP2-130HW Hardwired 5-30R 5-30P Hardwired
208V UL L
isted MicroPOD
L6-20P OR (2) L6-20R, (2) L6-15R,
Hardwire Connection OR Hardwire Connections
MP2-220N
(plug is removable for L6-20R L6-20P (receptacles are removable
h
ardwire applications) for hardwire applications)
230V CE M
arked MicroPODs
MP2-210K EN60320/C14 EN60320/C13 EN60320/C14 (4) EN60320/C13
MP2-220L EN60320/C20 EN60320/C19 EN60320/C20 (4) EN60320/C13, (1)EN60320/C19
OUTPUT
UPS
PUSH TO RESET
UPS
A
VAILABLE
UPS
UTILITY
MAINTENANCE BYP
ASS
AVAILABLE
CONNECT UPS
LINE CORD HERE
PUSH TO RESET
IF UTILITY LAMP IS IL
LUMINATED
MAINTENANCE BYPASS POSITION
MAY BE SELECTED
SWITCH TO UPS POSITION ONLY
WHEN UPS LAMP IS ILLUMINATED
CAUTION
OUTPUT
UTILITY
15
A
M
P
15
A
M
P
From Utility
Protected
Devices
MicroPOD
plugs into
UPS outlet
UPS plugs into
MicroPOD
Whi
l
e e
v
e
r
y pr
ec
aution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
r
e
s
ponsib
i
lity, and disclaims all liability for damages resulting
f
r
om u
s
e o
f this in
f
or
mation or for any errors or omissions.
© 2007 Liebert Corporation. All rights reserved throughout
the w
orld. Specifications subject to change without notice.
All n
ame
s referred to are trademarks or registered trademarks
of their respective owners.
® Li
ebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-23800 (R02/07) Printed in USA
B
usiness-Critical Continuity
, Eme
rson Network
P
o
w
e
r an
d the Eme
rson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2007 Emerson Electric Co.
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
™
.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via
Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong
Kong
852 25722201 Phone
852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)