3com 3C16850 Installation guide

Category
Network switches
Type
Installation guide

This manual is also suitable for

http://www.3com.com/
Switch 7700
Installation Guide
Version 3.0
3C16850 7-slot Starter Kit
3C16852 8-slot Starter Kit
3C16870 4-slot Starter Kit
and associated modules
Part No. 10014180
Document Number: DUA1685-0AA02
Published November 2004
3Com Corporation
350 Campus Drive
Marlborough, MA
01752-3064
Copyright © 2004, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced
in any form or by any means or used to make any derivative work (such as translation, transformation, or
adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time
to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either
implied or expressed, including, but not limited to, the implied warranties, terms or conditions of
merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or
changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy,
please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the software described herein
are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense.
Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995)
or
as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are
provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited
rights only as provided in DFAR 252.227-7015 (Nov
1995) or FAR 52.227-14 (June 1987), whichever is
applicable. You agree not to remove or deface any portion of any legend provided on any licensed program
or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com and the 3Com logo are registered trademarks of 3Com Corporation.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and
Windows NT are registered trademarks of Microsoft
Corporation. UNIX is a registered trademark in the
United States and other countries, licensed exclusively through X/Open Company, Ltd.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
All other company and product names may be trademarks of the respective companies with which they are
associated.
ENVIRONMENTAL STATEMENT
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy,
we are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized
environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is
fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly,
and the inks are vegetable-based with a low heavy-metal content.
CONTENTS
ABOUT THIS GUIDE
Conventions 7
Related Documentation 8
SWITCH 7700 COMPONENTS
Switch Chassis 9
Switch Backplane 9
Fabric Module 10
Submodule Slot 11
Reset Button 11
Fixed Ports 11
Module LEDs 12
Power LEDs 13
Fan LED 13
Fabric 32 Submodules 13
4-Port 1000BASE-X-GBIC Submodule 13
4-Port 10/100/1000BASE-T Submodule 14
I/O Modules 15
48-port 10/100BASE-T Auto-sensing FE Module 15
8-port 1000BASE-X GE Module 16
8-port 10/100/1000BASE-T GE Module 18
24-port 100BASE-FX MMF FE Module 19
20-Port 10/100/1000BASE-T Module 20
20-Port 1000BASE-X-SFP Module 22
1-Port 10GBASE-R-XENPAK Module 23
Power Module 24
Fan Assembly 25
Switch 7700 Specifications 26
Switch 7700 Software Features 27
INSTALLING THE SWITCH 7700
Preparing to Install 29
General Safety Recommendations 29
Electrical Safety 30
Moving the Switch 30
Laser Safety 30
General Site Requirements 30
Installation Space 31
Installation Checklist 31
Installing the Chassis 32
Installing in a Standard Cabinet 32
Installing on a Workbench 32
Installing the Cabling Rack 32
Installing a Module 33
Installing a Submodule 33
Connecting the Ground Wire 34
Connecting and Configuring Power 34
Connecting AC Power Cords 34
Connecting DC Power Cords 35
Configuring AC Power Sources 35
Installing the Fan Assembly 36
Installing Cables 36
Connecting the Console Cable 36
Connecting the AUX Cable 36
Connecting Module Cables 37
Installing Cabling 38
Bench-Mounted Switch 38
Rack-Mounted Switch 38
Cable Binding 38
Post-installation Checklist 39
CONFIGURING THE SWITCH 7700
Configuring the Switch 7700 and a Local Terminal 41
Setting Terminal Parameters 41
Booting the Switch 7700 44
Powering up and Booting 45
MAINTAINING SOFTWARE
Upgrading Software 47
Upgrading the Software Image 47
Upgrading an 8-Slot Chassis 47
Upgrading Software with FTP 48
Upgrading Software Using The BOOT Menu 49
Upgrading Software Using Xmodem 53
Upgrading Software Using TFTP 55
Lost Passwords 55
Using the BOOT Menu 55
MAINTAINING HARDWARE
Replacing a Power Module 57
Removing the AC Power Module 57
Installing the AC Power Module 57
Replacing a Power Supply 58
Replacing I/O Modules 59
Replacing the Fan Assembly 59
TROUBLESHOOTING
Troubleshooting the Configuration 61
No information is displayed on the terminal 61
The displayed characters are illegible 61
Troubleshooting Power 61
Troubleshooting the Fan 62
Troubleshooting the Modules 62
SWITCH 7700 CABLES
Console Cable 63
AUX Cable 63
Electrical Port Connector 64
Optical Fiber Cable Connectors 65
OBTAINING SUPPORT FOR YOUR SWITCH
Register Your Product to Gain Service Benefits 67
Purchase Value-Added Services 67
Troubleshoot Online 67
Access Software Downloads 67
Contact Us 68
Telephone Technical Support and Repair 68
ABOUT THIS GUIDE
This guide describes the 3Com
®
Switch 7700 and how to install hardware,
configure and boot software, and maintain software and hardware. This guide
also provides troubleshooting and support information for your switch.
This guide is intended for Qualified Service personnel who are responsible for
configuring, using, and managing the switches. It assumes a working knowledge
of local area network (LAN) operations and familiarity with communication
protocols that are used to interconnect LANs.
Always download the Release Notes for your product from the 3Com World Wide
Web site and check for the latest updates to software and product
documentation:
http://www.3com.com
Conventions Table 1 lists icon conventions that are used throughout this guide.
Table 2 lists text conventions that are used throughout this guide.
Table 1 Notice Icons
Icon Notice Type Description
Information note Information that describes important features or
instructions.
Caution Information that alerts you to potential loss of data
or potential damage to an application, system, or
device.
Warning Information that alerts you to potential personal
injury.
Tab le 2 Text Conventions
Convention Description
Screen displays This typeface represents information as it appears on the
screen.
Keyboard key names If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+), for example:
Press Ctrl+Alt+Del
The words “enter” and “type” When you see the word “enter” in this guide, you must type
something, and then press Return or Enter. Do not press
Return or Enter when an instruction simply says “type.”
8 ABOUT THIS GUIDE
Related
Documentation
The following manuals offer additional information necessary for managing your
Switch 7700:
Switch 7700 Command Reference Guide — Provides detailed descriptions of
command line interface (CLI) commands, that you require to manage your
Switch 7700.
Switch 7700 Configuration Guide— Describes how to configure your Switch
7700 using the supported protocols and CLI commands.
Switch 7700 Release Notes — Contains the latest information about your
product. If information in this guide differs from information in the release
notes, use the information in the Release Notes.
These documents are available in Adobe Acrobat Reader Portable Document
Format (PDF) on the CD-ROM that accompanies your router or on the 3Com
World Wide Web site:
http://www.3com.com/
Words in italics Italics are used to:
Emphasize a point.
Denote a new term at the place where it is defined in the
text.
Identify menu names, menu commands, and software
button names.
Examples:
From the Help menu, select Contents.
Click OK.
Words in bold Boldface type is used to highlight command names. For
example, “Use the display user-interface command
to...”
Table 2 Text Conventions
Convention Description
1
SWITCH 7700 COMPONENTS
The chapter describes the following Switch 7700 components:
Switch Chassis
Switch Backplane
Fabric Module
Fabric 32 Submodules
I/O Modules
Power Module
Fan Assembly
Switch 7700 Specifications
Switch 7700 Software Features
Switch Chassis There are three Switch 7700 Models, the 4-Slot, 7-Slot, and the 8-Slot. Table 3 lists
the hardware features of each model.
Switch Backplane The Switch 7700 backplane is part of the integrated chassis and delivers
high-speed data transfer between the Fabric and I/O modules. The backplane
bandwidth capacity is 120 Gbps.
The backplane supports the following functions:
Interconnection of signals between modules
Provides communication channels
Hot swapping for modules
Auto-recognition of slots
Distribution of power and management of the power supply for the system
Tab le 3 Hardware Features of the Switch 7700 Models
4-Slot Chassis 7-Slot Chassis 8-Slot Chassis
Fabric slots 1 1 2
I/O module slots 3 6 6
Fan slot 1 1 1
AC Power module
slots
2 3 3
10 CHAPTER 1: SWITCH 7700 COMPONENTS
Fabric Module There are two Fabric modules for the Switch 7700:
Fabric 64 (3C16857 or 3C16857R)
Fabric 32 (3C16872)
The Fabric 64 and Fabric 32 are not interchangeable. You can install the Fabric 32
only in a 4-slot chassis. You can install the Fabric 64 only in the 7- or 8-slot chassis
The Fabric module is the core of Switch 7700 system. It has the following
functions:
Connects the I/O modules through the backplane and forwards Layer 2 and
Layer 3 data
Manages and calculates routing
Performs the switch’s software upgrade and system reset functions
Monitors system power and the fan frame
Figure 1 illustrates the front panel of the Fabric 64.
Figure 1 Fabric 64
1 Reset button
2 Console port
3 Ethernet port
4 Ethernet port LEDs
5 Fan LEDs
6 Power module LEDs
7 I/O module LEDs
Figure 2 illustrates the front panel of the Fabric 32.
Figure 2 Fabric 32
1 Submodule slot
2 Console port
3 Ethernet port
4 Ethernet port LEDs
5 Fan LEDs
6 Power LEDs
7 I/O module LEDs
8 Reset button
3C16857
3C16857
1234
56
7
3C16872
3C16872
1234567
8
Fabric Module 11
Table 4 lists Fabric specifications.
Submodule Slot The submodule slot in the Fabric 32 offers extended Ethernet capacity using the
following submodules:
4-port 1000BASE-X-GBIC submodule
4-port 10/100/1000BASE-T submodule
For more information on these submodules, see “Fabric 32 Submodules”on
page 13.
Reset Button The reset button resets the entire system.
Fixed Ports The Switch 7700 Fabric module provides the following fixed ports:
Console Port
Ethernet Port
Console Port
The console port is connected to the configuration terminal using an RJ-45
connector. You can use the console port for system debugging, configuration,
maintenance, management, and loading application files.
The console port can also be connected to a modem for functions such as remote
system debugging, configuration, maintenance, and management. You can
configure the baud rate on the console port.
Table 5 lists console port specifications.
Tab le 4 Fabric Specifications
Item Fabric 64 (3C16857 or 3C16857R) Fabric 32 (3C16872)
Bandwidth 64 Gbps 32 Gbps
CPU MPC8260 200 Mhz
BootROM 1 MB
SDRAM 256 MB
Flash 16 MB
Submodule slot 1
Dimensions (L x W) 366.7 mm x 340 mm (14.5 x 13.5 in)
External ports One console port that supports local and remote dial-up configuration
management of the switch.
One 10BASE-T/100BASE-TX port for upgrade and network management
Maximum power
consumption
80 W 70 W (with submodule)
Tab le 5 Console Port Specifications
Specification Description
Port connector RJ-45
Port standard Asynchronous EIA/TIA-232
12 CHAPTER 1: SWITCH 7700 COMPONENTS
Ethernet Port
The Ethernet port on the Fabric is connected to a computer using an RJ-45
connector. You can use the Ethernet port for system application downloading and
debugging. The Ethernet port can also be connected to devices such as a network
management workstation to manage the system remotely.
Table 6 lists Ethernet port specifications.
See “Electrical Port Connector” on page 64 for an illustration of the RJ-45
connector and MDI/MDI-X pinout details.
Table 7 describes the LEDs of the Ethernet port.
Module LEDs The module LEDs show the status of the I/O modules, as described in Table 8.
Baud rate 9600 bps (by default)
Transmission distance 15 m (45 ft)
Services Connects with character terminal
Connects with local or remote PC serial port and runs terminal
emulation on a PC (a pair of modems are required for a
remote connection)
Tabl e 6 Ethernet Port Specifications
Specification Description
Port connector RJ-45
Number of port(s) 1
Port speed 10 Mbps, half/full duplex
100 Mbps, half/full duplex
MDIX
Cable and maximum transmission
distance
Category-5 twisted pair for transmission within 100 m
(300 ft)
Port function Switch software upgrade and network management
Tabl e 7 Ethernet Port LEDs
LED Description
LINK Off — The line is not connected.
Green — The line is connected.
ACTIVE Green — No data is being transmitted.
Green flashing — Data is being transmitted.
Table 5 Console Port Specifications (continued)
Specification Description
Tabl e 8 I/O Module LEDs
LED Status description
RUN Green or off — The module failed or has not been inserted.
Green flashing — The module is working normally.
ALM Off — The module is working normally or has not been
inserted.
Green or green flashing — The module failed or is not
working normally.
Fabric 32 Submodules 13
Power LEDs PWR1, PWR2, and PWR3 LEDs show the status of the power modules, as
described in
Table 9.
Fan LED Fan LEDs show the status of the fan frame, as described in Table 10.
Fabric 32 Submodules The Fabric 32 provides a slot for one submodule. The Fabric 32 supports the
following submodules:
4-Port 1000BASE-X-GBIC Submodule (3C16874)
4-Port 10/100/1000BASE-T Submodule (3C16873)
4-Port 1000BASE-X-GBIC
Submodule
The 4-port 1000BASE-X-GBIC submodule provides four GE full-duplex Ethernet
GBIC ports.
Figure 3 illustrates the 4-port 1000BASE-X-GBIC submodule.
Figure 3 4-Port 1000BASE-X-GBIC Submodule
Ethernet GBIC port
2 Ethernet GBIC port LED
Table 11 describes the 4-port 1000BASE-X-GBIC submodule LEDs.
Tab le 9 Power LEDs
LED Description
OK Green — The corresponding power module work is working
normally.
Off — The corresponding power module is not working or
has not been installed.
FAIL Green — The corresponding power module is not working.
Off — The corresponding power module works normally or
has not been installed.
Tab le 10 Fan LEDs
LED Description
OK Green — The fan is working normally.
Off — The fan is not working or has not been installed.
FAIL Green — The fan is not working.
Off — The fan is working normally or has not been installed.
Tab le 11 4-Port 1000BASE-X-GBIC Submodule LEDs
LED Description
LINK/ACT Green — The link is operating normally.
Off — The link is not operating.
Green flashing — Data is being transmitted.
3C16874
12
14 CHAPTER 1: SWITCH 7700 COMPONENTS
Table 12 lists the specifications for each of the 4-port 1000BASE-X-GBIC
submodule.
4-Port
10/100/1000BASE-T
Submodule
The 4-Port 10/100/1000BASE-T submodule provides four 10/100/1000 Mbps
auto-negotiation service ports.
Figure 4 illustrates the 4-port 10/100/1000BASE-T submodule.
Figure 4 4-Port 10/100/1000BASE-T Submodule
1 Ethernet port
2 Ethernet port LEDs
Table 13 describes the 4-port 10/100/1000BASE-T submodule LEDs.
Table 14 lists specifications of the 4-port 10/100/1000BASE-T submodule.
Tabl e 12 4-Port 1000BASE-X-GBIC Submodule Specifications
Optional GBIC
Module
Central
Wavelength
Connector
Type
Interface Fiber
Specifications
Max.
Transmission
Distance
1000BASE-SX-MM
(3CGBIC91)
850 nm SC 50/125 µm
multi-mode fiber
62.5/125 µm
Multi-mode fiber
500 m (1640 ft)
220 m (722 ft)
1000BASE-LX-SM-IR
(3CGBIC92)
1310 nm SC 9/125 µm
Single-mode fiber
10 km (6 mi)
1000BASE-LX-SM
(3CGBIC97)
1550 nm SC 9/125 µm
Single-mode fiber
40 km (25 mi)
70 km (43.5 mi)
Tabl e 13 4-Port 10/100/1000BASE-T Submodule LEDs
LED Description
LINK Off — The link is not operating.
On — The link is operating normally.
ACT Off — No data is being transmitted.
Green flashing — Data is being transmitted.
Tabl e 14 4-Port 10/100/1000BASE-T Submodule Specifications
Specification Description
Connector type RJ-45
Number of ports 4
Port speed 1000 Mbps full duplex
100 Mbps half/full duplex
10 Mbps half/full duplex
MDI/MDI-X auto-sensing
Cable and maximum
transmission distance
Category 5 twisted pair up to 100 m (328 ft)
3C16873
3C16873
12
I/O Modules 15
See “Electrical Port Connector” on page 64 for an illustration of the RJ-45
connector and MDI/MDI-X pinout details.
I/O Modules The Switch 7700 provides slots for three or six modules below the Fabric slots. The
following I/O modules are supported:
48-port 10/100BASE-T Auto-sensing FE Module (3C16860)
8-port 1000BASE-X GE Module (3C16858)
8-port 10/100/1000BASE-T GE Module (3C16859)
24-port 100BASE-FX MMF FE Module (3C16861)
20-Port 10/100/1000BASE-T Module (3C16863)
20-Port 1000BASE-X-SFP Module (3C16862)
1-Port 10GBASE-R-XENPAK Module (3C16875)
Consider the following when selecting I/O modules:
You can configure several I/O modules of the same type
All I/O module slots are the same and any combination of I/O modules can be
inserted
You must select I/O module port cables that are compatible with each installed
I/O module
48-port 10/100BASE-T
Auto-sensing FE Module
The 48-port 10/100BASE-T Auto-sensing FE module provides 48 external
100Mbps Ethernet electrical ports.
Figure 5 illustrates the 48-port 10/100BASE-T Auto-sensing FE module.
Figure 5 48-port 10/100BASE-T Auto-sensing FE Module
Figure 6 illustrates the front panel and LEDs of the 48-port 10/100BASE-T
Auto-sensing FE module.
Figure 6 Front Panel of the 48-Port 10/100BASE-T Auto-sensing FE module
12
16 CHAPTER 1: SWITCH 7700 COMPONENTS
1 Ethernet port
2 Ethernet port LED
Each 100 Mbps Ethernet port has a green LED, indicating LINK/ACTIVE status.
Table 15 describes the 48-port 10/100BASE-T Auto-sensing FE module LED.
Table 16 describes the specifications of the 48-port 10/100BASE-T Auto-sensing FE
module.
See “Electrical Port Connector” on page 64 for an illustration of the RJ-45
connector and MDI/MDI-X pinout details.
8-port 1000BASE-X GE
Module
The 8-port 1000BASE-X GE module provides 8 external GBIC module ports. A
GBIC module is used for each data receiving/transmitting channel. The following
modules are available:
3CGBIC91
3CGBIC92
3CGBIC97
Figure 7 illustrates the 8-port 1000BASE-X GE module.
Tabl e 15 48-Port 10/100BASE-T Auto-sensing FE module LED
LED Description
LINK/ACT Green — The port is connected
Off — The port is not connected
Green flashing — Data is being transmitted
Tabl e 16 Specifications for the 48-Port 10/100BASE-T Auto-sensing FE Module
Specification Description
CPU MPC850
BootROM 512 KB
SDRAM 64 MB
Dimensions (L X W) 366.7 x 340 mm (14.5 x 13.4 in)
Maximum power
consumption
55 W
Connector RJ-45
Number of ports 48
Port transmission
speed
10 Mbps half/full duplex
100 Mbps half/full duplex
MDI/MDIX auto-sensing
Cables and maximum
transmission distance
Cables are 2 100-ohm Category-5 twisted pairs up to 100 m (300 ft).
Compliance IEEE802.3
IEEE802.3u
IEEE802.3x
I/O Modules 17
Figure 7 8-Port 1000BASE-X GE Module
Every GBIC port has a LED, as shown in Figure 8.
Figure 8 Front Panel of the 8-Port 1000BASE-X GE Module
1 GBIC port
2 GBIC port LED
Table 17 describes the 8-Port 1000BASE-X (GBIC) GE module LED.
The cables for each of the supported 8GBIC modules are described inTable 18.
Table 19 describes the specifications of the 8-port 1000BASE-X GE module.
Tab le 17 8-Port 1000BASE-X (GBIC) GE Module LED
LED Description
LINK Off — The link is not connected
Green — The link is connected
ACT Off — No data is being transmitted
Green flashing — Data is being transmitted or received
Tab le 18 GBIC Module Port Cables
GBIC Module Type Central Wave Length
3CGBIC91 850 nm
3CGBIC92 1550 nm
3CGBIC97 1550 nm
Tab le 19 Specifications for the 8-Port 1000BASE-X GE Module
Specification Description
CPU MPC850
3C16858
12
18 CHAPTER 1: SWITCH 7700 COMPONENTS
8-port
10/100/1000BASE-T GE
Module
The 8-port 10/100/1000BASE-T GE module provides 8 external 10/100/1000
Mbps auto-sensing Ethernet electrical ports.
Figure 9 illustrates the 8-port 10/100/1000BASE-T GE module.
Figure 9 8-Port 10/100/1000BASE-T GE Module
Each port on the 8-port 10/100/1000BASE-T GE module has 2 LEDs, as shown in
Figure 10.
Figure 10 Front Panel of the 8-Port 10/100/1000BASE-T GE Module
1 Ethernet port
2 Ethernet port LEDs
BootROM 512 KB
SDRAM 64 MB
Dimensions (L x W) 366.7 x 340 mm (14.5 x 13.4 in)
Maximum power
consumption
50 W
Number of ports 8
Optional GBIC module
types
3CGBIC 91
3CGBIC 92
3CGBIC 97
Port transmission speed 1000 Mbps, full duplex
Compliance IEEE 802.3z
IEEE 802.3x
Table 19 Specifications for the 8-Port 1000BASE-X GE Module (continued)
Specification Description
12
I/O Modules 19
Table 20 describes the LEDs on the 8-port 10/100/1000BASE-T GE module.
Specifications of the 8-port 10/100/1000BASE-T GE module are described in
Table 21.
24-port 100BASE-FX
MMF FE Module
The 24-port 100BASE-FX MMF FE module provides 24 100 Mbps multi-mode
Ethernet optical port service channels.
Figure 11 illustrates the 24-port 100BASE-FX MMF FE module.
Figure 11 24-Port 100BASE-FX MMF FE Module
Tab le 20 8-Port 10/100/1000BASE-T GE Module LEDs
LED Description
LINK Off — The link is not connected
Green — The link is connected
ACT Off — No data is being transmitted
Green flashing — Data is being transmitted or received
Tab le 21 Specifications for the 8-Port 10/100/1000BASE-T GE Module
Specification Description
CPU MPC850
BootROM 512 Kb
SDRAM 64 MB
Dimensions (L x W) 366.7 x 340 mm (14.5 x 13.4 in)
Maximum power consumption 50 W
Connector type RJ-45
Number of ports 8
Port transmission speed 10 Mbps, half/full duplex
100 Mbps, half/full duplex
1000 Mbps, full duplex
Cables and maximum
transmission distance
4 100-ohm Category-5 non-shielded twisted pairs up to 100
m (300 ft).
Compliance IEEE 802.3ab
IEEE802.3
IEEE802.3u
IEEE802.3x
20 CHAPTER 1: SWITCH 7700 COMPONENTS
Each 100 Mbps optical port has a green LED, as shown in Figure 12.
Figure 12 Front Panel of the 24-Port 100BASE-FX MMF FE Module
1 Ethernet port
2 Ethernet port LED
Table 22 describes the status of the 24-port 100BASE-FX MMF FE module LEDs.
The 24-port 100BASE-FX MMF FE module requires a 62.5/125 µm multi-mode
optical fiber cable with an MT-RJ connector and a central wavelength of 1300 nm.
Table 23 describes the specifications of the 24-port 100BASE-FX MMF FE module.
20-Port
10/100/1000BASE-T
Module
The 20-Port 10/100/1000BASE-T module provides 20 10/100/1000BASE-T
auto-sensing Ethernet ports.
Figure 13 illustrates the 20-Port 10/100/1000BASE-T Module.
Tabl e 22 24-Port 100BASE-FX MMF FE Module LEDs
LED Description
LINK/ACT Green — The port is connected.
Off — The port is not connected.
Green flashing — Data is being transmitted or received.
Tabl e 23 Specifications for the 24-Port 100BASE-FX MMF FE Module
Specification Description
CPU MPC850
BootROM 512 KB
SDRAM 64 MB
Dimensions (L x W) 366.7 x 340 mm (14.5 x 13.4 in)
Maximum power
consumption
55 W
Connector type MT-RJ
Number of ports 24
Port transmission speed 100 Mbps, full-duplex
Cables and maximum
transmission distance
62.5/125 µm multi-mode optical fiber up to 2 km (1.3 mi)
Compliance IEEE 802.3
IEEE 802.3i
IEEE 802.3u
IEEE 802.3x
1
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

3com 3C16850 Installation guide

Category
Network switches
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI