CAME MI6010, MI6020, MI6110, MI6120 Installation guide

Type
Installation guide
Documentazione
Tecnica
M85
rev. 2.0
03/2003
©
CAME
CANCELLI
AUTOMATICI
119PM85-GB
AUTOMATIC DOORS
ANTIPANIC BREAKTHROUGH SYSTEM
ONLY FOR MOBILE DOORSCTRIC CONTROL PANELS
ARMOIRESARMOIRES
ARMOIRESARMOIRES
ARMOIRES
DEDE
DEDE
DE
COMMANDECOMMANDE
COMMANDECOMMANDE
COMMANDE
SCHALTTAFEL
CUADROSCUADROS
CUADROSCUADROS
CUADROS
DEDE
DEDE
DE
MANDOMANDO
MANDOMANDO
MANDO
MI
CANCELLI AUTOMATICI
10
20
MI6010 - 6110
MI6020 - 6120
COMPLETE MECHANICAL ENSEMBLE
to be applied on sliding opening frames.
In emergencies, it allows the OPENING of the ESCAPE EXIT
by BREAKING THROUGH THE DOORS.
Up to 120 kg per door
- pg. 2 -
pg. 3
pg. 4
pg. 5
pg. 8÷13
pg. 16÷19
pg. 20
pg. 21/22
pg. 23
pg. 24
- Operation and Use Limits
- Type of MI Antipanic System
- What the MI Package Contains
MI FOR COMMERCIAL SERIES
- Section types and special instructions for door construction
MI FOR CAME S40 SERIES
- Section Types
- MI Antipanic Bar Machining
- Mounting of MI Antipanic System
- Spiral cable application and mobile door mounting
- Power connections
TABLE OF CONTENTSTABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
TABLE OF CONTENTS
- pg. 3 -
Sliding door INTERNAL MOUNTING solution:
Antipanic breakthroughs are successful only IF THE DOOR
IS FULLY CLOSED, not during movement.
The sliding door's operation can be restarted simply by moving
the door/doors to the side.
Sliding door EXTERNAL MOUNTING solution:
Complete antipanic breakthrough can be achieved NO
MATTER WHAT POSITION THE SLIDING DOORS ARE
IN during movement;
This is the preferred solution to fully exploit the characteristics
of the antipanic breakthrough system.
Also in this case the sliding door's operation can be restarted
simply by moving the door/doors to the side.
INTERNO
locale da evacuare
ESTERNO
locale da evacuare
INTERNO
locale da evacuare
ESTERNO
locale da evacuare
EMPLOYMENT LIMITS
OPERATION and USE LIMITSOPERATION and USE LIMITS
OPERATION and USE LIMITSOPERATION and USE LIMITS
OPERATION and USE LIMITS
htdiW A
)mm(
ELGNIS
ROOD
)gk(thgiew.xaM
repdettimda
ROODELGNIS
htiW ASROC
citamotua
metsys
htiW OEDOR
citamotua
metsys
005 57 021
006 57 09
007 57 08
008 06 07
009 05 06
0001 54 05
0011 04 04
ehtfognitnuomehT 3714P sileehw
yrotadnamrevohtiw 0011 otpudna
0051 (mm 0216IM/0116IM .)
For MI6010 and MI6020 (door width of up to 1100 mm),
the maximum weight for each door indicated can be increased
by attaching a sliding wheel on the ground (part. P4173, pages
5 & 13).
WARNING: if the P4173 sliding wheel is added, the
adequate linearity of the plane on which it must turn must be
ensured.
- pg. 4 -
COMPLETE ANTIPANIC BREAKTHROUGH
SYSTEM FOR 2 SLIDING DOORS
with A up to 1100 mm = MI6010
with A up to 1500 mm = MI6110
A
AA
MOUNTING FROM
INSIDE THE
ROOM TO BE
EVACUATED
MOUNTING FROM
OUTSIDE THE
ROOM TO BE
EVACUATED
MOUNTING FROM
INSIDE THE
ROOM TO BE
EVACUATED
MOUNTING FROM
OUTSIDE THE
ROOM TO BE
EVACUATED with A up to 1100 mm = MI6020
with A up to 1500 mm = MI6120
Types of MI Antipanic SystemsTypes of MI Antipanic Systems
Types of MI Antipanic SystemsTypes of MI Antipanic Systems
Types of MI Antipanic Systems
COMPLETE ANTIPANIC BREAKTHROUGH
SYSTEM FOR 1 SLIDING DOOR
- pg. 5 -
Antipanic breakthrough kit componentsAntipanic breakthrough kit components
Antipanic breakthrough kit componentsAntipanic breakthrough kit components
Antipanic breakthrough kit components
LOWER HINGE FOR MOBILE DOOR
ANTIPANIC SYSTEM FOR MOBILE DOOR
UPPER JOINT
ANTIPANIC SPRING LATCH
FIXED UPPER SECTION
OPENABLE LOWER SECTION
HOOKING PLATES TO CARRIAGES
LOWER HINGE
MOBILE DOOR
FLOOR GUIDE
ANTE MOBILIANTE MOBILI
ANTE MOBILIANTE MOBILI
ANTE MOBILI
MI6010/6110 represented; in
MI6020/6120 the components are
doubled.
SLIDING WHEEL
CONTACT CAPS
Art. P4116
Art. P4117
Art. PM338A
Art. PM205
Art. PM207
Art. PM208
Art. PM209
Art. PM912
Art. PM911A
Art. P4173
Art. PL593
GUIDE STOP
Art. PM339A
Art. PM909
+PM910
+PM913
Art. C7039
Art. PL564
Art. PM576
Art. TB57
Art. PM923
Art. FN930
TERMINAL
COUPLING
SUPPORT
FIXING SUPPORT
SLIDING TUBE
SPIRAL CABLE
NYLON YARN
Art. PI405
RIP CORD 2X0,5
WARNING!It is a standard piece in all
set and it must be used in
applications in which the size of the
doors is not observed.
See pg. 3.
- pg. 6 -
This page left intentionally blank
- pg. 7 -
MI System
applied to
commercial series
of sections for
automatic sliding doors
The sections, sizes, weather strip and everything else
mentioned in the following pages as
commercial series
are
purely indicative and appear solely for the purpose of illustrating
the applicability of the MI system on sliding doors with frames
other than our series S40 type.
- pg. 8 -
istruzioni di montaggio per istruzioni di montaggio per
istruzioni di montaggio per istruzioni di montaggio per
istruzioni di montaggio per SERIE COMMERCIALISERIE COMMERCIALI
SERIE COMMERCIALISERIE COMMERCIALI
SERIE COMMERCIALI
Our MI antipanic breakthrough series have been designed to be applied even on
sliding doors built with any type of adequately adapted commercial series.To this
purpose, the following pages contain the necessary measurements and/or notes
to plan and resize the doors.
Preliminary Notes:
- The preparation of the doorframes must allow the insertion of the hinge pins; it is
recommended that the faced and fixed cross members be mounted with U-bolts;
- Upper and lower hinging alignment must be axial.
- Pay attention to how the hinge elements are attached to the structure. They should be fixed
rigidly in order to avoid that with time vibrations and movement limit efficiency and make the
system unsafe for users;
- If the structure is not strong enough, the assembler must reinforce it.
- Upper and lower hinges must be aligned axially.
- Only in case of mobile doors, it is recommended that the glass be firmly set with silicone
sealant in addition to any other types of weather strip.
- Only stratified or tempered glass should be used.
MOBILE DOORS:
- Resize the length of the upright and cross sections according to the size of the sections
used- follow indications on pages 9÷13;
- Fasten the elements that make up the antipanic system for mobile doors.
- If necessary, insert the "wheel" device (art. P4173). See pg. 3.
ANTIPANIC BAR
- Cut sections PM339A and PM338A and chamfer and bore holes in section PM338A as
indicated on page 20.
- Apply the bar on the mobile door, mount the spiral cable and finish mounting the doors on the
Corsa or Rodeo beam, adapting the instructions for the S40 series on pages 21-23.
- Carry out the power connections and checks as indicated on page 24.
MAKE SURE THE BREAKTHROUGH SIDE IS THE CORRECT ONE AND THAT THE ANTIPANIC SYSTEM FOR
MOBILE DOORS IS COMPLETE BEFORE PERFORMING ANY MACHINING WORK!
- pg. 9 -
Vertical section with COMMERCIAL SERIESVertical section with COMMERCIAL SERIES
Vertical section with COMMERCIAL SERIESVertical section with COMMERCIAL SERIES
Vertical section with COMMERCIAL SERIES
127
169
151
13
80
M
H
Y
15
29
9
40
±6
C
43
INSIDE THE ROOM TO BE EVACUATED
LC00
151
13
80
M
H
Y
15
29
9
135
195
40
±6
D
43
LD00
MOUNTING FROM OUTSIDE THE ROOM TO BE EVACUATED
LEGEND
H= wall opening heigh
Y= Corsa/Rodeo beam fixing height:
with LC00 = H + 18*
with LD00 = H + 44*
M= sliding door height** = Y -108
C/D = Height under beam box = H
* these measurements allow net light continuity at the
passage between indoors and outdoors (H = C/D);
**Other specific dimensions are not provided for the
mobile door. Please refer to the door supplier's
documentation.
The use of LC00 or LD00 does not affect the choice of
mounting solution (inside or outside); even the Y fixing
height can be adapted to individual needs, as long as
the other formulas are also adapted.
BREAKTHROUGH
DIRECTION
INSIDE THE ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
MOUNTING FROM INSIDE THE ROOM TO BE EVACUATED
- pg. 10 -
L
Vsf
A
6
min
29 ±6
LC00
LD00
LEGEND
L= wall opening width
Vsf = Width of passage created with breakthrough
A* = Sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE AVACUATED
L
Vsf
A
LC00
LD00
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION
MI6010 / MI6110
MI6020 / MI6120
Horizontal sections with the COMMERCIAL SERIESHorizontal sections with the COMMERCIAL SERIES
Horizontal sections with the COMMERCIAL SERIESHorizontal sections with the COMMERCIAL SERIES
Horizontal sections with the COMMERCIAL SERIES
MOUNTING FROM INSIDE THE ROOM TO BE EVACUATED
- pg. 11 -
Horizontal sections with the COMMERCIAL SERIESHorizontal sections with the COMMERCIAL SERIES
Horizontal sections with the COMMERCIAL SERIESHorizontal sections with the COMMERCIAL SERIES
Horizontal sections with the COMMERCIAL SERIES
LEGEND
L= wall opening witdth
Vsf = Width of passage created with breakthrough
A* = Sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
L
Vsf
A
29 ±6
LC00
LD00
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE AVACUATED
LC00
LD00
L
Vsf
A
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE AVACUATED
MI6010 / MI6110
MI6020 / MI6120
MOUNTING FROM OUTSIDE THE ROOM TO BE EVACUATED
- pg. 12 -
22
80 25 85 80
50
70 69 69 200 max
25 56
11
190
COMMERCIAL SERIES mounting instructionsCOMMERCIAL SERIES mounting instructions
COMMERCIAL SERIES mounting instructionsCOMMERCIAL SERIES mounting instructions
COMMERCIAL SERIES mounting instructions
Art. PM339A
Art. PM338A
Art. PM208
Art. PM207
Art. PM205
Art. PM306
Art. PM911A Art. PL593
Thickening and reinforcing
the frame to be sized and
positioned are care of the
constructor.
INSIDE MOUNTINGINSIDE MOUNTING
INSIDE MOUNTINGINSIDE MOUNTING
INSIDE MOUNTING
OUTSIDE MOUNTINGOUTSIDE MOUNTING
OUTSIDE MOUNTINGOUTSIDE MOUNTING
OUTSIDE MOUNTING
HINGING OF
MOBILE DOORS
69
*MAM002 is simply a finishing accessory
that may be replaced with any other type of
finish the constructor chooses, even if it
requires a larger section of the door's
upright.
Art. MAM002*
- pg. 13 -
COMMERCIAL SERIES mounting instructionsCOMMERCIAL SERIES mounting instructions
COMMERCIAL SERIES mounting instructionsCOMMERCIAL SERIES mounting instructions
COMMERCIAL SERIES mounting instructions
200 max
200 max
10
Art. PM339A
Art. PM338A
Art. PM909
+PM910
+PM913
Art. P4117
When sizing sections PM339A and PM338A, pay attention to
the type of finish for the door in order to correctly align all
components.
- MOBIL DOORS-
FRONTAL MATCH
SLIDING WHEEL - OPTIONAL
Place the wheel at a sufficient distance so as to avoid contact with the
ground during the sliding door's opening, but not too far as this would hinder
easy rehooking.
9
60
83
143
5
1 ÷ 3
Art. P4173
WARNING!!!
Sliding surfaces presenting
irregularities or furrows affect the
proper operation of this element.
- pg. 14 -
This page left intentionally blank
- pg. 15 -
MI System
Applied to our section series
for S40
automatic sliding doors
The following two pages have only some application examples
with our sections; for a complete series of the construction
types, heights and construction parts for the creation of these
doorframes, please refer to the technical documentation of
the S40 series.
- pg. 16 -
L
65
53
Vsf
A
H
M15
13
80
LC00
LEGEND
H= wall opening height
L= wall opening width
Vsf = Width of passage created with breakthrough
M= sliding door height
A* = sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
INDOOR ROOM TO BE AVACUATED
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION INDOOR ROOM TO BE AVACUATED
S40 series - sectionsS40 series - sections
S40 series - sectionsS40 series - sections
S40 series - sections
MOUNTING FROM INSIDE THE ROOM TO BE EVACUATED
- pg. 17 -
S40 series - sectionsS40 series - sections
S40 series - sectionsS40 series - sections
S40 series - sections
Vsf
L
A
4
H
M15
44
80
LD00
LEGEND
H= wall opening height
L= wall opening width
Vsf = Width of passage created with breakthrough
M= Mobile door height
A* = Sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION INDOOR ROOM TO BE AVACUATED
BREAKTHROUGH
DIRECTION
MOUNTING FROM INSIDE THE ROOM TO BE EVACUATED
- pg. 18 -
53
81
A
80
H
M15
13
L =Vsf
S40 series - sectionsS40 series - sections
S40 series - sectionsS40 series - sections
S40 series - sections
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
LC00
MOUNTING FROM OUTSIDE THE ROOM TO BE EVACUATED
LEGEND
H= wall opening height
L= wall opening width
Vsf = Width of passage created with breakthrough
M= Mobile door height
A* = Sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
- pg. 19 -
S40 series - sectionsS40 series - sections
S40 series - sectionsS40 series - sections
S40 series - sections
44
15 M
H
80
L = Vsf
A
LD00
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE EVACUATED
MOUNTING FROM OUTSIDE THE ROOM TO BE EVACUATED
LEGEND
H= wall opening height
L= wall opening width
Vsf = Width of passage created with breakthrough
M= Mobile door height
A* = Sliding door width
* Use MI6010 or MI6020 with A up to 1100;
use MI6110 or MI6120 with A up to 1500.
- pg. 20 -
- Take out the PM339A (1)
and PM338A (2) upper and lower
hooking sections from the
package and remove the parts
inserted into them.
- Cut them to the proper
length using the indicated formu-
la.
- Correctly evaluate the
breakthrough side of the doors and
work the lower section (2) as in
the illustration **. .
** The illustration shows the
work that must be performed on
the left door. The right door will
require mirror-image work.
ANTIPANIC BAR machiningANTIPANIC BAR machining
ANTIPANIC BAR machiningANTIPANIC BAR machining
ANTIPANIC BAR machining
DX
SX
45°
42
111
180
Wl + 50
1
2
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
INDOOR ROOM TO BE EVACUATED
BREAKTHROUGH
DIRECTION
2
bore a 7 hole with a 200 max pitch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

CAME MI6010, MI6020, MI6110, MI6120 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document