www.cls-led.com www.cls-led.com
65
PROGRAMMING
CH1
UsethisDMXchanneltosetaddressfrom001to
255.TheconfiguredDMXaddressiscalled“n”
CH2
UsethisDMXchanneltosetaddressfrom256to
508.TheconfiguredDMXaddressiscalled“n”
CH3 Static
behavior
IfnoDMXispresentthefixturewillrespondlike
setinthisfunction.
CH4 Softdim
SoftdimwillinterpolatebetweentheDMX
values.Thisfunctionmakesthedimcurve
CH5 Master
control
Ifmasterisfirstchannelisselectedthechannel
willbeDMXchannel“n”.Ifmasterislastchannel
isselectedthechannelwillbe“n+x”
(“x”iscalculatedintheoutputpatch).
CH6 Output1
patch
Eachoutputchannelcanbepatchedtorespond
tothedesiredDMXchannel.Thisenablesthe
usertomixupthecoloursaccordingtothe
controllerthatisused.
Example:alloutputsarepatchedas1
AlloutputswillbecontrolledbyDMXchannel
“n”.IfmasterisusedtotalDMXchannelswillbe2
otherwiseituses1channel(“x”=1).
Example:output1&2arepatchedas1and3&4
arepatchedas2
Output1&2willbecontrolledbyDMXchannel
“n”.
Output3&4willbecontrolledbyDMXchannel
“n+1”.
IfmasterisusedtotalDMXchannelswillbe3
otherwiseituses2channels(“x”=2).
CH7Output2
patch
CH8 Output3
patch
CH9Output4
patch
CH10Staticoutput
1
Eachoutputchannelcanbesettoanstatic
intensity.
IfnoDMXispresentandStaticbehaviorissetto
“loadstaticvalues”.Theoutputswillbesettothe
configuredintensityvalues.
CH11Staticoutput
2
CH12Staticoutput
3
CH13Staticoutput
4
CH14Loaddefault
settings
ThisfunctionresetsallsettingstotheFactory
setting.CheckFactorysettingtable.
X
LoadFactorysettings.Xisrow
numberfactorysettingtable.
PROGRAMMING TABLE
123
* If the LEDs ashes 10 times, something went wrong. Please try again. If the problem continues to occur, please contact your local sales distributor.
After 2 seconds
the LED will ash
3 times
conrming
storage*
Place magnet
at the bottom
of the Jade.
The LED will
light up
FACTORY SETTING TABLE
All settings can be configured via DMX. Settings can be configured at once or separately. When one or a couple settings needs to be
changed just leave all other setting values zero. This keeps those settings unchanged. Please check the table for more information.
Always use a DMX controller with digital interface. If not available, you can purchase the CLS D-ta DMX addresser unit (
#122200
).
First make sure to set the DATA on the DMX controller. To program the setting into the LED fixture follow the next steps.
Max. 20 pieces of Jade per DMX line on a rail.Max. 20 pieces of Jade can be connected in a group.
WIRELESS DMX
See the Manual of WIreless Solutions. The Manual can be found on our CLS website, in the Downloads section. Or use the link below
https://www.cls-led.com/wp-content/uploads/cls-files/W-DMX-manual.pdf
Unlink procedure
When the fixture does not receive a DMX signal (DMX controller off), place the magnet on the bottom of the fixture for 5 seconds.
Slow flash indicates that the fixture is unlinked.