Waeco ST-8810 Owner's manual

Type
Owner's manual

This manual is also suitable for

DE 2 Infrarot-Thermometer
Bedienungsanleitung
EN 11 Infrared Thermometer
Operating manual
FR 19 Thermomètre infrarouge
Manuel d’utilisation
ES 28 Termómetro de infrarrojos
Instrucciones de uso
IT 37 Termometro a infrarossi
Istruzioni per l’uso
NL 46 Infrarood thermometer
Gebruiksaanwijzing
DA 54 Infrarødt termometer
Betjeningsvejledning
SV 62 Infraröd temperaturmätare
Bruiksanvisning
NO 71 Infrarødt termometer
Bruiksanvisning
FI 79 Infrapuna-lämpömittari
Käyttöohje
ST-8810
_ST-8810.book Seite 1 Donnerstag, 2. Februar 2006 11:24 11
ST-8810 Safety instructions
11
Contents
1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Measurement Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Battery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1 Safety instructions
z Use extreme caution when the laser beam is powered on.
z Do not point the laser beam into your eyes, another person’s
eye or the eye of an animal.
z Make sure that the laser beam pointed on a reflective surface
don’t strike your eye.
z Do not allow the laser beam pointed on any gas which can
explode.
2 Technical description
Features
z Precise non-contact measurements
z Built-in laser pointer
z Selection of °C/°F indication
z Automatic data hold
z Auto power off
z Backlight LCD display
_ST-8810.book Seite 11 Donnerstag, 2. Februar 2006 11:24 11
Technical description ST-8810
12
z At a distance of 200 mm the meter can measure targets with a diameter
of 25 mm (at a distance of 400 mm: target diameter 50 mm, etc.; see
Fig. 1).
Wide range application
Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt, Ma-
rine and screen printing, measure ink and dryer temperature, Diesel and
Fleet maintenance.
2.1 Front panel
1
IR sensor
2
Laser pointer beam
3
LCD Display
4
“°F” key
5
“°C” key
6
“Backlight” key
7
“Laser” key
8
“On/Hold” key (Measuring)
9
Battery compartment
16 mm
Ø 25 mm
Ø 50 mm
Ø 100 mm
Ø 200 mm
0 200 400 800 1600 mm
Laser marker
Infrared
Fig. 1
1
2
3
4
6
5
7
8
9
Fig. 2
_ST-8810.book Seite 12 Donnerstag, 2. Februar 2006 11:24 11
ST-8810 Measurement Operation
13
2.2 Indicator
3 Measurement Operation
3.1 Power ON/OFF
The meter automatically powers up when the key is pressed. Pull the “On/
Hold” key to read the display. Read the measured temperature on the LCD
(Fig. 4). The meter automatically powers off approximately 7 s after releasing
the “On/Hold” key.
1
Digital read-out
2
Temperature °C (Celsius)
3
Temperature °F (Fahrenheit)
4
Measuring indication
5
Data Hold
6
Low battery indicator
7
Laser Pointer
8
Fixed emissivity (0.95)
9
Backlight
1
2
3
6
5
4
78
9
Fig. 3
Fig. 4
_ST-8810.book Seite 13 Donnerstag, 2. Februar 2006 11:24 11
Measurement Operation ST-8810
14
3.2 Selecting temperature unit (°C/°F)
Select the temperature unit (degrees °C or degrees °F) by first pressing the
“On/Hold” key and then pressing the “°C” or “°F” key. The actual unit will be
indicated on the LCD.
Press the “°C” key to set the unit to “degrees °C”. (Fig. 5).
Press the “°F” key to set the unit to “degrees °F” (Fig. 6).
3.3 Data hold
The meter automatically maintains the last temperature reading on the LCD
for 7 s after releasing the “On/Hold” key. No additional keys are required to
freeze the displayed reading (Fig. 7).
3.4 Backlight LCD
Turn on the backlight by first pressing the “On/Hold” key and then pressing
the “Backlight” key.
Repeat the procedure to turn the backlight off (Fig. 8).
Fig. 5 Fig. 6
Fig. 7
Fig. 8
_ST-8810.book Seite 14 Donnerstag, 2. Februar 2006 11:24 11
ST-8810 Battery replacement
15
3.5 Laser pointer
To turn on the laser pointer, press the “Laser” key while pressing the “On/
Hold” key (Fig. 9).
Press the “Laser” key again to turn off the laser (Fig. 10).
3.6 Measurement considerations
Hold the meter by its handle, point the IR sensor towards the object whose
temperature is to be measured. The meter automatically compensates for
temperature deviations from ambient temperature.
Keep in mind that it will take up to 30 minutes to adjust if wide ambient
temperatures have been measured. After measuring low temperatures and
before measuring high temperature, allow some time (at least several
minutes) for the cooling process of the IR sensor.
4 Battery replacement
If the battery power is not sufficient, the LCD will display a battery symbol to
indicate that a new 9 V battery is required (Fig. 11).
Open the battery cover. Remove the battery from the meter and replace it
with a new 9 Volt battery. Close the battery cover.
Fig. 9 Fig 10
Fig. 11
_ST-8810.book Seite 15 Donnerstag, 2. Februar 2006 11:24 11
Notes ST-8810
16
5Notes
How it works
Infrared thermometers measure the surface temperature of an object. The
meter’s optics sense emitted, reflected and transmitted energy, which is
collected and focused onto a detector. The meter’s electronics translate the
information into a temperature reading which is indicated on the display. In
meters with a laser, the laser is used for aiming purposes only.
Field of view
Make sure that the target is larger than the unit’s spot size. The smaller the
target, the closer you should be to it. If accuracy is critical, make sure the tar-
get is at least twice as large as the spot size.
Distance and spot size
When the distance from the object increases, the spot size of the area
measured by the meter becomes larger (Fig. 1).
Locating a hot spot
To find a hot spot aim the thermometer outside the area of interest, then scan
across the area of interest with an up and down motion until you locate the
hot spot.
Reminders
z The meter is not recommended for measuring shiny or polished metal
surfaces such as stainless steel, aluminium, etc. (see “Emissivity”).
z The meter cannot measure through transparent surfaces such as glass.
It will measure the surface temperature of the glass instead.
z Steam, dust, smoke, etc., can prevent accurate measurement by ob-
structing the meter’s optics.
Emissivity
Most organic materials and painted or oxidized surfaces (90% of typical
applications) have an emissivity of 0.95 (pre-set in the unit). Inaccurate read-
ings will result from measuring shiny or polished metal surfaces. To compen-
sate cover the surface to be measured with masking tape or flat black paint.
Allow some time for the tape to reach the same temperature as the material
underneath it. Measure the temperature of the tape or painted surface.
_ST-8810.book Seite 16 Donnerstag, 2. Februar 2006 11:24 11
ST-8810 Notes
17
Emissivity values:
Substance
Thermal
emissivity
Substance
Thermal
emissivity
Asphalt 0.90 to 0.98
Cloth (black) 0.98
Concrete 0.94 Human skin 0.98
Cement 0.96
Lather 0.75 to 0.80
Sand 0.90 Charcoal (powder) 0.96
Earth 0.92 to 0.96
Lacquer 0.80 to 0.95
Water 0.92 to 0.96 Lacquer (matt) 0.97
Ice 0.96 to 0.98
Rubber (black) 0.94
Snow 0.83 Plastic 0.85 to 0.95
Glass 0.90 to 0.95
Timber 0.90
Ceramic 0.90 to 0.94 Paper 0.70 to 0.94
Marble 0.94
Chromium oxides 0.81
Plaster 0.80 to 0.90 Copper oxides 0.78
Mortar 0.89 to 0.91
Iron oxides 0.78 to 0.82
Brick 0.93 to 0.96 Textiles 0.90
_ST-8810.book Seite 17 Donnerstag, 2. Februar 2006 11:24 11
Technical data ST-8810
18
6 Technical data
Versions, technical modifications and delivery options reserved.
Item number ST-8810
Display 3-1/2 digit (1999 count) LCD with backlight
Measure range –20 °C to +270 °C (–4 °F to +518 °F)
Resolution 1 °C / 1 °F
Accuracy ±2 % of reading or ±2 °C / ±4 °F
z Accuracy is given at 18 °C to 28 °C (64 °F to
85 °F), less than 80 % RH
z Specified accuracy is valid for an emissivity of
0.95
Emissivity settings 0.95 fixed
Distance factor distance:spot = approx. 8 : 1
Sample rate approx. 1 s
Spectral response 6 – 14 µm
Power off automatic shut off after 7 seconds inactivity
Operating temperature 0 °C to +50 °C (+32 °F to +122 °F)
Operating RH% max. 80 % RH
Power supply 9 V battery
Weight 180 g
Size 159 x 76 x 57 mm
_ST-8810.book Seite 18 Donnerstag, 2. Februar 2006 11:24 11
Europe
WAECO Schweiz AG
Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)
Fon: +41 44 8187171
Fax: +41 44 8187191
WAECO Danmark A/S
Tværvej 2
DK-6640 Lunderskov
Fon: +45 75585966
Fax: +45 75586307
WAECO Ibérica S.A.
Camí del Mig, 106
Poligono Industrial Les Corts
E-08349 Cabrera de Mar
(Barcelona)
Fon: +34 93 7502277
Fax: +34 93 7500552
WAECO Distribution SARL
ZAC 2 · Les Portes de L‘Oise
Rue Isaac Newton – BP 59
F-60230 Chambly (France)
Fon: +33 1 30282020
Fax: +33 1 30282010
WAECO Finland OY
Mestarintie 4
FIN-01730 Vantaa
Fon: +358 20 7413220
Fax: +358 9 7593700
E-Mail: waeco@waeco.fi
WAECO Italcold SRL
Via dell’Industria 4/0
I-40012 Calderara di Reno (BO)
Fon: +39 051 727094
Fax: +39 051 727687
WAECO Norge AS
Leif Weldingsvei 16
N-3208 Sandefjord
Fon: +47 33428450
Fax: +47 33428459
E-Mail: firmapo[email protected]
WAECO Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
Fon: +31 76 5029000
Fax: +31 76 5029090
E-Mail: verkoop@waeco.nl
WAECO Svenska AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
(Göteborg)
Fon: +46 31 7341100
Fax: +46 31 7341101
WAECO UK Ltd.
Dorset DT2 8LY · Unit G
Roman Hill Business Park
UK-Broadmayne
Fon: +44 1305 854000
Fax: +44 1305 854288
CH
DK
E
F
FIN
I
N
NL
S
UK
Overseas + Middle East
WAECO Pacific Pty. Ltd.
1 John Duncan Court
Varsity Lakes QLD 4227
Fon: +61 7 55076000
Fax: +61 7 55221003
WAECO Impex Ltd.
Headquarters
Suites 3210-12 · 32/F · Tower 2
The Gateway · 25 Canton Road
Tsim Sha Tsui · Kowloon
Hong Kong
Fon: +852 2 4632750
Fax: +8 52 24639067
E-Mail: info@waeco.com.hk
WAECO Impex Ltd.
Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan
Fon: +886 2 27014090
Fax: +886 2 27060119
E-Mail: marketing@waeco.com.tw
WAECO Middle East FZCO
R/A 8, SD 6
Jebel Ali, Dubai
Fon: +971 4 8833858
Fax: +971 4 8833868
E-Mail: waeco@emirates.net.ae
WAECO USA, Inc.
8 Heritage Park Road
Clinton, CT 06413
Fon: +1 860 6644911
Fax: +1 860 6644912
E-Mail: customercare@waecousa.com
AUS
HK
ROC
UAE
USA
Headquarters
WAECO International GmbH · Hollefeldstraße 63 · D-48282 Emsdetten
Fon: +49 2572 879-195 · Fax: +49 2572 879-322 · E-Mail: info@waeco.de · Internet: www.waeco.de
D
www.waeco.com
3.01.06.01497 02/2006
_ST-8810.book Seite 88 Donnerstag, 2. Februar 2006 11:24 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Waeco ST-8810 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI