  • Hello! I am an AI chatbot trained to assist you with the Mettler Toledo Multi-parameter Transmitter M200 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Operation Manual
Multi-parameter
Transmitter M200
Transmitter M200 2
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
Transmitter M200 3
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
Operation Manual
Multi-parameter
Transmitter M200
Transmitter M200 4
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
Content
1 Introduction ___________________________________________________________________________________________ 7
2 Safety instructions ______________________________________________________________________________________ 7
2.1 DenitionofEquipmentandDocumentationSymbolsandDesignations _______________________________________ 7
2.2 CorrectDisposaloftheUnit __________________________________________________________________________ 8
3 Unit Overview __________________________________________________________________________________________ 9
3.1 Overview 1/4DIN __________________________________________________________________________________ 9
3.2 Overview 1/2DIN __________________________________________________________________________________ 9
3.3 Control/NavigationKeys ___________________________________________________________________________ 10
3.3.1 MenuStructure ___________________________________________________________________________ 10
3.3.2 NavigationKeys __________________________________________________________________________ 10
3.3.2.1 NavigatingtheMenuTree _________________________________________________________ 10
3.3.2.2 Escape _______________________________________________________________________ 11
3.3.2.3 Enter _________________________________________________________________________ 11
3.3.2.4 Menu _________________________________________________________________________ 11
3.3.2.5 Calibration Mode ________________________________________________________________ 11
3.3.2.6 Info Mode _____________________________________________________________________ 11
3.3.3 NavigationofDataEntryFields ______________________________________________________________ 11
3.3.4 EntryofDataValues,SelectionofDataEntryOptions _____________________________________________ 11
3.3.5 NavigationwithuinDisplay ________________________________________________________________ 12
3.3.6 ”Savechanges”Dialog ____________________________________________________________________ 12
3.3.7 SecurityPasswords _______________________________________________________________________ 12
3.4 Display ________________________________________________________________________________________ 12
4 Installation instruction __________________________________________________________________________________ 13
4.1 UnpackingandInspectionofEquipment _______________________________________________________________ 13
4.2 Installation – 1/4DIN Models _______________________________________________________________________ 13
4.2.1 1/4DINVersion–DimensionDrawings ________________________________________________________ 13
4.2.2 InstallationProcedure–1/4DINModels _______________________________________________________ 14
4.3 Installation – 1/2DIN Models _______________________________________________________________________ 15
4.3.1 1/2DINVersion–DimensionDrawings ________________________________________________________ 15
4.3.2 1/2DINVersion–PipeMounting _____________________________________________________________ 15
4.3.3 InstallationProcedure–1/2DINModels _______________________________________________________ 16
4.4 ConnectionofPowerSupply ________________________________________________________________________ 18
4.4.1 1/4DINHousing(PanelMount) ______________________________________________________________ 18
4.4.2 1/2DINHousing(WallMount)_______________________________________________________________ 19
4.5 ConnectorTerminalDenition _______________________________________________________________________ 20
4.5.1 TB1andTB2for1/2DINand1/4DINVersions __________________________________________________ 20
4.5.2 TB3/TB4*–pH,ORP,DissolvedOxygen,Ozoneand4-ElectrodeConductivitySensor ____________________ 20
4.5.3 TB3/TB4–2-electrodeConductivitySensor _____________________________________________________ 21
4.6 AssemblingofSensorandCable ____________________________________________________________________ 22
4.6.1 ConnectionofSensorsforpH,ORP,DissolvedOxygen,Ozoneand4-electrodeConductivity _______________ 22
4.6.2 AK9CableAssignment ____________________________________________________________________ 22
5 Placing transmitter in, or Out of Service ____________________________________________________________________ 23
5.1 PlacingTransmitterinService _______________________________________________________________________ 23
5.2 PlacingTransmitterOutofService ___________________________________________________________________ 23
6 Quick Setup __________________________________________________________________________________________ 24
7 Sensor Calibration _____________________________________________________________________________________ 25
7.1 EnterCalibrationMode ____________________________________________________________________________ 25
7.2 Conductivity/ResistivityCalibration ___________________________________________________________________ 25
7.2.1 One-point Sensor Calibration _______________________________________________________________ 26
7.2.2 Two-pointSensorCalibration(4-electrodeSensorsonly) __________________________________________ 26
7.2.3 ProcessCalibration _______________________________________________________________________ 27
7.3 OxygenCalibration _______________________________________________________________________________ 28
7.3.1 One-Point Sensor Calibration ________________________________________________________________ 28
7.3.2 ProcessCalibration _______________________________________________________________________ 28
7.4 pH Calibration ___________________________________________________________________________________ 29
7.4.1 One-Point Calibration _____________________________________________________________________ 29
7.4.1.1 Auto Mode _____________________________________________________________________ 29
7.4.1.2 Manual mode __________________________________________________________________ 30
7.4.2 Two-Point Calibration _____________________________________________________________________ 30
7.4.2.1 Auto Mode _____________________________________________________________________ 30
7.4.2.2 Manual Mode __________________________________________________________________ 31
7.4.3 ProcessCalibration _______________________________________________________________________ 31
7.5 ORP Calibration _________________________________________________________________________________ 32
7.5.1 One-Point Calibration ______________________________________________________________________ 32
Transmitter M200 5
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
7.6 Ozone Calibration ________________________________________________________________________________ 32
7.6.1 One-Point ZeroPt Calibration ________________________________________________________________ 32
7.6.2 ProcessCalibration _______________________________________________________________________ 33
7.7 SensorVerication ________________________________________________________________________________ 33
8 Conguration _________________________________________________________________________________________ 34
8.1 EnterCongurationMode __________________________________________________________________________ 34
8.2 Measurement ___________________________________________________________________________________ 34
8.2.1 ChannelSetup ___________________________________________________________________________ 34
8.2.2 Derived Measurements ____________________________________________________________________ 35
8.2.2.1 %Rejectionmeasurement ________________________________________________________ 35
8.2.2.2 CalculatedpH(PowerPlantApplicationsonly) ________________________________________ 36
8.2.2.3 CalculatedCO
2
(PowerPlantApplicationsonly) ________________________________________ 36
8.2.3 ParameterRelatedSettings _________________________________________________________________ 36
8.2.3.1 Conductivity/TemperatureCompensation _____________________________________________ 37
8.2.3.2 pH Parameters _________________________________________________________________ 38
8.2.3.3 DissolvedOxygenParameters _____________________________________________________ 38
8.2.4 SetAveraging ____________________________________________________________________________ 39
8.3 AnalogOutputs __________________________________________________________________________________ 40
8.4 Setpoints ______________________________________________________________________________________ 41
8.5 Alarm/Clean ____________________________________________________________________________________ 42
8.5.1 Alarm __________________________________________________________________________________ 42
8.5.2 Clean __________________________________________________________________________________ 43
8.6 Display ________________________________________________________________________________________ 43
8.6.1 Measurement ____________________________________________________________________________ 43
8.6.2 Resolution ______________________________________________________________________________ 44
8.6.3 Backlight _______________________________________________________________________________ 44
8.6.4 Name __________________________________________________________________________________ 44
8.7 HoldAnalogOutputs ______________________________________________________________________________ 45
9 System ______________________________________________________________________________________________ 46
9.1 SetLanguage ___________________________________________________________________________________ 46
9.2 USB ___________________________________________________________________________________________ 46
9.3 Passwords _____________________________________________________________________________________ 47
9.3.1 ChangingPasswords ______________________________________________________________________ 47
9.3.2 ConguringMenuAccessforOperator _________________________________________________________ 47
9.4 Set/ClearLockout ________________________________________________________________________________ 48
9.5 Reset __________________________________________________________________________________________ 48
9.5.1 ResetSystem ____________________________________________________________________________ 48
9.5.2 ResetAnalogCalibration ___________________________________________________________________ 48
10 Service ______________________________________________________________________________________________ 49
10.1 Diagnostics _____________________________________________________________________________________ 49
10.1.1 Model/Software Revision ___________________________________________________________________ 49
10.1.2 DigitalInput _____________________________________________________________________________ 49
10.1.3 Display ________________________________________________________________________________ 50
10.1.4 Keypad ________________________________________________________________________________ 50
10.1.5 Memory ________________________________________________________________________________ 50
10.1.6 SetRelay _______________________________________________________________________________ 50
10.1.7 ReadRelays _____________________________________________________________________________ 51
10.1.8 SetAnalogOutputs _______________________________________________________________________ 51
10.1.9 ReadAnalogOutputs ______________________________________________________________________ 51
10.2 Calibrate _______________________________________________________________________________________ 51
10.2.1 CalibrateAnalog _________________________________________________________________________ 52
10.2.2 CalibrateUnlock __________________________________________________________________________ 52
10.3 TechService ____________________________________________________________________________________ 52
11 Info _________________________________________________________________________________________________ 53
11.1 Messages ______________________________________________________________________________________ 53
11.2 Calibration Data _________________________________________________________________________________ 53
11.3 Model/Software Revision ___________________________________________________________________________ 54
11.4 Sensor Info _____________________________________________________________________________________ 54
12 Maintenance __________________________________________________________________________________________ 55
12.1 FrontPanelCleaning ______________________________________________________________________________ 55
13 Troubleshooting _______________________________________________________________________________________ 56
13.1 Cond(Resistivity)ErrorMessages/Warning-andAlarmList ______________________________________________ 57
13.2 OxygenErrorMessages/Warning-andAlarmList _______________________________________________________ 57
13.3 pHErrorMessages/Warning-andAlarmList __________________________________________________________ 57
13.4 ORPErrorMessages/Warning-andAlarmList _________________________________________________________ 58
Transmitter M200 6
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
13.5 Warning-andAlarmIndicationontheDisplay __________________________________________________________ 58
13.5.1 WarningIndication________________________________________________________________________ 58
13.5.2 AlarmIndication __________________________________________________________________________ 58
14 Accessories and Spare Parts _____________________________________________________________________________ 59
15 Specications _________________________________________________________________________________________ 60
15.1 GeneralSpecications _____________________________________________________________________________ 60
15.2 ElectricalSpecications ____________________________________________________________________________ 62
15.3 MechanicalSpecications __________________________________________________________________________ 62
15.3.1 MechanicalSpecicationsfor1/2DINVersion ___________________________________________________ 62
15.3.2 MechanicalSpecicationsfor1/4DINVersion ___________________________________________________ 63
15.4 EnvironmentalSpecications _______________________________________________________________________ 63
16 Default Tables _________________________________________________________________________________________ 64
16.1 M200(1-channelVersion) _________________________________________________________________________ 64
16.2 M200(2-channelVersion) _________________________________________________________________________ 65
16.3 ParameterRelatedValues __________________________________________________________________________ 67
16.3.1 Conductivity _____________________________________________________________________________ 67
16.3.2 Oxygen ________________________________________________________________________________ 68
16.3.3 pH ____________________________________________________________________________________ 69
16.3.4 ORP ___________________________________________________________________________________ 70
16.3.5 Ozone _________________________________________________________________________________ 70
17 Warranty _____________________________________________________________________________________________ 71
18 Certicate ____________________________________________________________________________________________ 72
19 Buffer Tables __________________________________________________________________________________________ 73
19.1 Mettler-9 _______________________________________________________________________________________ 73
19.2 Mettler-10 ______________________________________________________________________________________ 73
19.3 NISTTechnicalBuffers _____________________________________________________________________________ 74
19.4 NISTStandardBuffers(DIN19266:2000–01) _________________________________________________________ 74
19.5 HachBuffers ___________________________________________________________________________________ 75
19.6 Ciba(94)Buffers ________________________________________________________________________________ 75
19.7 MerckTitrisole,Riedel-de-HaënFixanale ______________________________________________________________ 76
19.8 WTWBuffers ____________________________________________________________________________________ 76
Transmitter M200 7
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
1 Introduction
StatementofIntendedUse–TheM200multi-parametertransmitterisa1-or2-channelonline
processinstrumentformeasuringvariouspropertiesofuids.TheseincludeConductivity/
Resistivity,DissolvedOxygen,pH,ORPandOzone.Itwillinterfacewithavarietyofdifferent
Mettler-Toledosensors,whichconnecttothetransmitterusingcablesofvariedlengths.
AlargefourlinebacklitLiquidCrystalDisplayconveysmeasuringdataandsetupinformation.
Themenustructureallowstheoperatortomodifyalloperationalparametersbyusingkeyson
thefrontpanel.Amenu-lockoutfeature,withpasswordprotection,isavailabletopreventthe
unauthorizeduseofthemeter.TheM200multi-parametertransmittercanbeconguredtouse
its2(4on2-channelversion)analogand/or2relayoutputsforprocesscontrol.
TheM200multi-parametertransmitterisequippedwithaUSBcommunicationinterface.This
interfaceprovidesreal-timedataoutputandcompleteinstrumentcongurationcapabilitiesfor
centralmonitoringviaPersonalComputer(PC).
ThismanualappliesforallavailableM200transmittersasfollows:
– Multi-parameter2-channelversion
– Multi-parameter1-channelversion
Theprintscreenimagesinthismanualhaveageneralexplainingcharacterandcandifferfrom
therealdisplayinyourtransmitter.
2 Safety instructions
Thismanualincludessafetyinformationwiththefollowingdesignationsandformats.
2.1 DenitionofEquipmentandDocumentationSymbols
and Designations
a
WARNING:POTENTIALFORPERSONALINJURY.
a
CAUTION:possibleinstrumentdamageormalfunction.
h
NOTE:Importantoperatinginformation.
a
On the transmitter or in this manual text indicates:Cautionand/orotherpossiblehazard
includingriskofelectricshock(refertoaccompanyingdocuments).
Transmitter M200 8
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
Thefollowingisalistofgeneralsafetyinstructionsandwarnings.Failuretoadheretothese
instructionscanresultindamagetotheequipmentand/orpersonalinjurytotheoperator.
– TheM200transmittershouldbeinstalledandoperatedonlybypersonnelfamiliarwith
thetransmitterandwhoarequaliedforsuchwork.
– TheM200transmittermustonlybeoperatedunderthespeciedoperatingconditions
(seesection15“Specications”).
– RepairoftheM200transmittermustbeperformedbyauthorized,trainedpersonnelonly.
– Withtheexceptionofroutinemaintenance,cleaningproceduresorfusereplacement,as
describedinthismanual,theM200transmittermustnotbetamperedwithoralteredin
anymanner.
– Mettler-Toledoacceptsnoresponsibilityfordamagecausedbyunauthorizedmodications
tothetransmitter.
– Followallwarnings,cautions,andinstructionsindicatedonandsuppliedwiththisproduct.
– Installequipmentasspeciedinthisinstructionmanual.Followappropriatelocaland
nationalcodes.
– Protectivecoversmustbeinplaceatalltimesduringnormaloperation.
– Ifthisequipmentisusedinamannernotspeciedbythemanufacturer,theprotection
providedbyitagainsthazardsmaybeimpaired.
WARNINGS:
Installationofcableconnectionsandservicingofthisproductrequireaccesstoshockhazard
voltagelevels.
Mainpowerandrelaycontactswiredtoseparatepowersourcemustbedisconnectedbefore
servicing.
Switchorcircuitbreakershallbeincloseproximitytotheequipmentandwithineasyreachof
theOPERATOR;itshallbemarkedasthedisconnectingdevicefortheequipment.
Mainpowermustemployaswitchorcircuitbreakerasthedisconnectingdeviceforthe
equipment.
ElectricalinstallationmustbeinaccordancewiththeNationalElectricalCodeand/oranyother
applicablenationalorlocalcodes.
h
NOTE:RELAYCONTROLACTION:theM200transmitterrelayswillalwaysde-energizeonloss
ofpower,equivalenttonormalstate,regardlessofrelaystatesettingforpoweredoperation.
Congureanycontrolsystemusingtheserelayswithfail-safelogicaccordingly.
h
NOTE:PROCESSUPSETS:Becauseprocessandsafetyconditionsmaydependonconsistent
operationofthistransmitter,provideappropriatemeanstomaintainoperationduringsensor
cleaning,replacementorsensororinstrumentcalibration.
2.2 Correct Disposal of the Unit
Whenthetransmitterisnallyremovedfromservice,observealllocalenvironmental
regulationsforproperdisposal.
Transmitter M200 9
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
3 Unit Overview
M200modelsareavailableinbotha1/4DINand1/2DINcasesize.The1/4DINisapanel-
mountonlydesignandthe1/2DINmodelsprovideanintegralIP65housingforwall-,orpipe-
mount.
3.1 Overview 1/4DIN
4.01"
102 mm
4.01"
102 mm
EnterInfo
METTLER TOLEDO
ESC
Menu Cal
M200
1
2
3
4
5
6
7
8
1–HardPolycarbonatecase
2–FiveTactile-FeedbackNavigationKeys
3–Four-lineLCDisplay
4–PowerSupplyTerminals
5–USBInterfacePort
6–RelayOutputTerminals
7–AnalogOutput/DigitalInputTerminals
8 – Sensor Input Terminals
3.2 Overview 1/2DIN
EnterInfo
CalMenu
M200
1
2
3
ESC
5.90"
150 mm
5.90"
150 mm
4
5
6
7
8
1–HardPolycarbonatecase
2–FiveTactile-FeedbackNavigationKeys
3–Four-lineLCDisplay
4–PowerSupplyTerminals
5–USBInterfacePort
6–RelayOutputTerminals
7–AnalogOutput/DigitalInputTerminals
8 – Sensor Input Terminals
Transmitter M200 10
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
3.3 Control/Navigation Keys
3.3.1 Menu Structure
BelowisthestructureoftheM200menutree:
Measurement
Mode M200
CalMenu Info
Quick Setup Configure System Service
Measurement
Analog Outputs
Set Points
Alarm/Clean
Display
Calibrate
Tech Service
Diagnostics
Hold Outputs
Set Language
USB
Passwords
Set/Clear
Lockout
Reset
Messages
Sensor Info
Calibration Data
Model/Software
Revision
Channel Setup
Analog Outputs
Set Points
3.3.2 Navigation Keys
Menu Cal
Info
Enter
ESC
3.3.2.1 Navigating the Menu Tree
EnterthedesiredmainMenubranchwiththe c or .keys.Usethe and .keysto
navigatethroughtheselectedMenubranch.
h
N O T E : Inordertobackuponemenupage,withoutescapingtothemeasurementmode,
movethecursorundertheUPArrowcharacter(u) atthebottomrightofthedisplayscreenand
press[Enter].
Transmitter M200 11
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
3.3.2.2 Escape
Pressthe and ckeysimultaneously(escape)toreturntotheMeasurementmode.
3.3.2.3 Enter
Usetheekeytoconrmactionorselections.
3.3.2.4 Menu
PressthekeytoaccessthemainMenu.
3.3.2.5 Calibration Mode
PresstheckeytoenterCalibrationMode.
3.3.2.6 Info Mode
Pressthe.keytoenterInfoMode
3.3.3 NavigationofDataEntryFields
Usetheckeytonavigateforwardorthekeytonavigatebackwardswithinthechangeable
dataentryeldsofthedisplay.
3.3.4 EntryofDataValues,SelectionofDataEntryOptions
Usethekeytoincreaseorthe.keytodecreaseadigit.Usethesamekeystonavigate
withinaselectionofvaluesoroptionsofadataentryeld.
h
N O T E : Somescreensrequireconguringmultiplevaluesviathesamedataeld(ex:conguring
multiplesetpoints).Besuretousethec or keytoreturntotheprimaryeldandthe or
.keytotogglebetweenallcongurationoptionsbeforeenteringtothenextdisplayscreen.
Transmitter M200 12
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
3.3.5 Navigation with u in Display
If a uisdisplayedonthebottomrighthandcornerofthedisplay,youcanusethecorthe
keytonavigatetoit.Ifyouclick[ENTER]youwillnavigatebackwardsthroughthemenu
(gobackonescreen).Thiscanbeaveryusefuloptiontomovebackupthemenutreewithout
havingtoexitintothemeasuringmodeandre-enterthemenu.
3.3.6 ”Save changes” Dialog
Threeoptionsarepossibleforthe”Savechanges”dialog:Yes&Exit(Savechangesandexitto
measuringmode),”Yes&u”(Savechangesandgobackonescreen)and”No&Exit”(Don’t
savechangesandexittomeasuringmode).The”Yes&u”optionisveryusefulifyouwantto
continueconguringwithouthavingtore-enterthemenu.
3.3.7 Security Passwords
TheM200transmitterallowsasecuritylock-outofvariousmenus.Ifthesecuritylock-out
featureofthetransmitterhasbeenenabled,asecuritypasswordmustbeenteredtoallow
accesstothemenu.Seesection9.3”System/Passwords”formoreinformation.
3.4 Display
h
N O T E : IntheeventofanalarmorothererrorconditiontheM200transmitterwilldisplaya
ashing intheupperrightcornerofthedisplay.Thissymbolwillremainuntilthecondition
thatcausedithasbeencleared.
h
N O T E : Duringcalibrations,clean,DigitalInwithAnalogOutput/Relay/USBinHoldstate,
aashingHwillappearintheupperleftcornerofthedisplay.Thissymbolwillremainfor
20secondsuntilafterthecalibrationorcleaniscompleted.Thissymbolwillalsodisappear
whenDigitalInisdeactivated.
Transmitter M200 13
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4 Installation instruction
4.1 UnpackingandInspectionofEquipment
Inspecttheshippingcontainer.Ifitisdamaged,contacttheshipperimmediatelyforinstructions.
Donotdiscardthebox.
Ifthereisnoapparentdamage,unpackthecontainer.Besureallitemsshownonthepacking
list are present.
Ifitemsaremissing,notifyyourMETTLERTOLEDOrepresentativeimmediately.
4.2 Installation – 1/4DIN Models
4.2.1 1/4DINVersion–DimensionDrawings
110 mm / 4.33"
102 mm / 4.02"
90 mm / 3.54"
102 mm / 4.02"
Power
102 mm / 4.02"
126 mm / 4.96"
125 mm / 4.92"
90 mm / 3.54"
110 mm / 4.33"
TB1A
TB1B
USB
TB2
TB4 TB3
Fuse
1 2
45 mm / 1.77"
max. 3 mm
0.118"
2
3
92 mm
3.62"
+0.02"
+0.5 mm
92 mm
3.62"
+0.02"
+0.5 mm
1
4
1–Dimensionsforpanelcutout
2–Mountingscrews,2pieces
3–Flatgasket,1piece
4–Mountingbracket,2pieces
Transmitter M200 14
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.2.2 Installation Procedure – 1/4DIN Models
1/4DINModeltransmittersaredesignedforpanel-mountinstallationonly.Eachtransmitteris
suppliedwithmountinghardwaretoprovidefastandsimpleinstallationtoaatpanelorat
enclosuredoor.ToinsureagoodsealandmaintainIP65integrityofinstallation,thepanelor
doormustbeatandhaveasmoothnish.
Thesuppliedhardwareconsistsof:
Twopiecessnap-onmountingbrackets
Onepiecemountinggasketseal
– Makecutoutinpanel.Fordimensionsreferto4.2.1“1/4DINVersion–DimensionDrawings”.
– Besuresurfacesurroundingcutoutisclean,smoothandfreeofburrs.
– Slidefacegasketaroundtransmitterfromthebackoftheunit.
– Placetransmitterintocutouthole.Besuretherearenogapsbetweenthetransmitter
andpanelsurface.
– Placethetwomountingbracketsoneithersideofthetransmitterasshown.
– Whileholdingtransmitterrmlyintothecutouthole,pushthemountingbrackets
towardthebacksideofpanel.
– Oncesecure,useascrewdrivertotightenthebracketsagainstthepanel.Inordertoprovide
IP65environmentalenclosurerating,thetwoclampsprovidedshallbesecurelytightenedto
createanadequatesealbetweenthepanelenclosureandM200frontface.
– Facegasketwillcompressbetweentransmitterandpanel.
a
CAUTION:Donotovertightenbrackets.
Transmitter M200 15
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.3 Installation – 1/2DIN Models
4.3.1 1/2DINVersion–DimensionDrawings
136 mm/5.35"
116 mm/4.57"
29 mm
1.14"
29 mm
1.14"
84 mm
3.31"
42 mm
1.65"
150 mm/5.9"
6.5 mm
0.256"
150 mm/5.9"
M200
90 mm/3.54"
80 mm/3.15"
75 mm/2.95"
35 mm/
1.38"
6 mm/
0.236"
90 mm/3.54"
137 mm
5.39"
+0.02"
+0.5 mm
137 mm
5.39"
+0.02"
+0.5 mm
1
1–Dimensionsforpanelcutout
4.3.2 1/2DINVersion–PipeMounting
40 ... 60 mm
1.57... 2.36"
Transmitter M200 16
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.3.3 Installation Procedure – 1/2DIN Models
1/2DINModeltransmittersaredesignedforthefollowinginstallationversions:panalmount,
wallmountorpipemount.Forwallmounttheintegralrearcoverisused.
Optionalhardwareaccessoriesareavailablethatallowforpanel-orpipe-mount.
Refertosection14“AccessoriesandSpareParts”.
Assembly:
1
2
3
1 3piecesM20cableglands
2 2piecesplasticplugs
3 4piecesscrews
General:
– Orientthetransmittersothatthecablegripsfacedownward.
– Wiringroutedthroughthecablegripsshallbesuitableforuseinwetlocations.
– InordertoprovideIP65enclosureratings,allcableglandsmustbeinplace.Eachcable
glandmustbelledusingacable,orsuitablecableglandholeseal.
ForPanelMount:
Toinsureagoodseal,thepanelordoormustbeatandhaveasmoothnish.Texturedor
roughsurfacesarenotrecommendedandmaylimittheeffectivenessofthegasketseal
provided.
– Makecutoutinpanel.Fordimensionsreferto4.3.1“1/2DINVersion–DimensionDrawings”.
– Besuresurfacesurroundingcutoutisclean,smoothandfreeofburrs.
– Slidefacegasketaroundtransmitterfromthebackoftheunit.
– Placetransmitterintocutouthole.Besuretherearenogapsbetweenthetransmitter
andpanelsurface.
– Placethetwomountingbracketsoneithersideofthetransmitterasshown.
– Whileholdingtransmitterrmlyintothecutouthole,pushthemountingbrackets
towardthebacksideofpanel.
– Oncesecure,useascrewdrivertotightenthebracketsagainstthepanel.Inordertoprovide
IP65environmentalenclosurerating,thetwoclampsprovidedshallbesecurelytightenedto
createanadequatesealbetweenthepanelenclosureandM200frontface.
– Facegasketwillcompressbetweentransmitterandpanel.
Transmitter M200 17
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
ForWallMount:
– Removerearcoverfromfronthousing.
– Startbyunscrewingthefourscrewslocatedonthefaceofthetransmitter,ineachcorner.
Thisallowsthefrontcovertoswingawayfromtherearhousing.
– Removethehinge-pinbysqueezingthepinfromeachend.
Thisallowsthefronthousingtoberemovedfromtherearhousing.
– Mountrearhousingtowallusingonlymanufacturer-suppliedmountingkit.Securemounting
kittotheM200accordingtothesuppliedinstructions.Attachtowallusingappropriate
mountinghardwareforwallsurface.Besureitislevelandsecurelyfastenedandthe
installationadherestoanyandallclearancedimensionsrequiredfortransmitterserviceand
maintenance.Orientthetransmittersothatthecablegripsarefacingdownward.
– Replacethefronthousingtotherearhousing.Securelytightentherear-coverscrewsto
ensurethatIP65enclosureenvironmentalratingisprovided.Theunitisreadytobewired.
ForPipeMount:
– Useonlymanufacturer-suppliedcomponentsforpipe-mountingtheM200transmitterand
installperthesuppliedinstructions.Seesection14“AccessoriesandSpareParts” for
orderinginformation.
Transmitter M200 18
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.4 Connection of Power Supply
Allconnectionstothetransmitteraremadeontherearpanelofallmodels.
a
Besurepowertoallwiresisturnedoffbeforeproceedingwiththeinstallation.Highvoltage
maybepresentontheinputpowerwiresandrelaywires.
Atwo-terminalconnectorontherearpanelofallM200modelsisprovidedforpower
connection.AllM200modelsaredesignedtooperatefroma20–30VDCora100to240VAC
powersource.Refertospecicationsforpowerrequirementsandratingsandsizepowerwiring
accordingly.
Theterminalblockforpowerconnectionsislabeled”Power”ontherearpanelofthe
transmitter. One terminal is labeled – NfortheNeutralwireandtheother+ L fortheLine(or
Load)wire.Thereisnoearthgroundterminalonthetransmitter.Forthisreasontheinternal
powerwiringwithinthetransmitterisdoubleinsulatedandtheproductlabeldesignatesthis
usingthedsymbol.
4.4.1 1/4DIN Housing (Panel Mount)
1
2
1: Connectionofpowersupply
2: Terminalforsensors
Transmitter M200 19
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.4.2 1/2DIN Housing (Wall Mount)
1
2
1: Connectionofpowersupply
2: Terminalforsensors
Transmitter M200 20
© 03/2016 Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Transmitter Multi-parameter M200
Printed in Switzerland 30 300 227
4.5 ConnectorTerminalDenition
4.5.1 TB1andTB2for1/2DINand1/4DINVersions
Power connections are labeled –N for Neutral and +L for Line, for 100 to 240 VAC or 20 30 VDC.
1
4
DIN
1
2
DIN
* Dual channel only
TB1A for
1
4
DIN
1 NO2
2 COM2
3 NC2
4–
5–
6–
7–
TB1B for
1
4
DIN
1 NO1
2 COM1
3 NC1
4–
5–
6–
7–
TB2 for
1
4
DIN
1 AO1+
2 AO1–/AO2–
3 AO2+
4 AO3+*
5 AO3–/AO4–*
6 AO4+*
7 DI1+
8 DI1–/DI2–*
9 DI2+*
TB2 for
1
2
DIN
1 AO1+
2 AO1–/AO2–
3 AO2+
4 AO3+*
5AO3–/AO4–*
6 AO4+*
7DI1+
8DI1–/DI2–*
9DI2+*
1 NO1
2 COM1
3 NC1
4 NO2
5 COM2
6 NC2
7–
8–
9–
10
11
12
13
14
TB4
TB2
TB3
TB1A
TB1B
17
17
9
1
9
1
9
1
TB2TB3
TB4
TB1
114
191919
TB1 for
1
2
DIN
NO: normallyopen(contactopenifun-actuated) AO:AnalogOutput
NC: normallyclosed(contactclosedifun-actuated) DI:DigitalInput
4.5.2 TB3/TB4* – pH, ORP, Dissolved Oxygen, Ozone and
4-ElectrodeConductivitySensor
ThewiringofthesensorsforpH,oxygen,ozoneand4-electrodeconductivitytoTB3resp.TB4
is:
Terminal Sensor wire color Function
1
2
3 Cablecore(transparent) 1-Wire
4 Shield(red) GND(5VDC)
5
6 GND(5VDC)
7 RS485–B
8 RS485–A
9 5VDC
*Onlyon2-channelversion.
/