Chore-Time MT1805A CHORE-TRONICS® Expanded Backup Control Installation and Operators Instruction Manual

Type
Installation and Operators Instruction Manual
Expanded Backup Control
Installation & Operators Instruction Manual
MT1805AMarch 2004
CTB Inc. Warranty
CTB Inc. Warranty Expanded Backup Control
2
MT1805A
CTB Inc. warrants each new Chore-Tronics® product manufactured by it to be free from defects in material or
workmanship for one year from and after the date of initial installation by or for the original purchaser. If such
a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option,
(a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the
original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated
with the replacement or repair of the product are not covered by the Manufacturer.
Conditions and Limitations
1. The product must be installed by and operated in accordance with the instructions published by the
Manufacturer or Warranty will be void.
2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer.
3. This product must be purchased from and installed by an authorized distributor or certified representative
thereof or the Warranty will be void.
4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper
maintenance shall not be considered defects under the Warranty.
5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry
or commerce are not covered by this Warranty.
The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer
or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein
include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders,
lost income, increased overhead, labor and incidental costs and operational inefficiencies.
THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND
THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO
MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR
QUALITY OF THE PRODUCT FURNISHED HEREUNDER.
Chore-Tronics® Distributors are not authorized to modify or extend the terms and conditions of this Warranty in
any manner or to offer or grant any other warranties for Chore-Tronics® products in addition to those terms
expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The
Manufacturer reserves the right to change models and specifications at any time without notice or obligation to
improve previous models.
Effective: May 2004
CTB Inc.
P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (877) 730-8825
Email: [email protected] Internet: http//www.ctbinc.com
Thank You
The employees of CTB Inc. would like to thank your for your recent Chore-Tronics® purchase. If a problem
should arise, your Chore-Tronics® distributor can supply the necessary information to help you.
Contents
Topic Page User
MT1805A
* Legend: C = Customer (end user), D = Distributor (sales), I = Installer of equipment
3
CTB Inc. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 C
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C
Support Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C,I
Follow Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Decal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DANGER : Electrical Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction to Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 C
Thermostat functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Thermostat 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Thermostats 2, and 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Thermostats 4, and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Switch Stickers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Thermostat Temperature Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 C,I
Thermostats & Inlet Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Relay Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Internal Wiring #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Internal Wiring #2 (Thermostat and Toggle Switch). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
General
General Expanded Backup Control
4
MT1805A
Support Information
The Chore-Tronics® Expanded Backup Control is used to provide a backup system for an electronically
controlled livestock or poultry facility. Using this equipment for any other purpose or in a way not within the
operating recommendations specified in this manual will void the warranty and may cause personal injury. This
manual is designed to provide comprehensive planning, installation, safety, operation, and parts listing
information. The Table of Contents provides a convenient overview of the information in this manual. The Table
of Contents also specifies which pages contain information for the sales personnel, installer, and consumer (end
user).
Safety Information
Caution, Warning and Danger Decals have been placed on the equipment to warn
of potentially dangerous situations. Care should be taken to keep this information
intact and easy to read at all times. Replace missing or damaged safety decals
immediately.
Using the equipment for purposes other than specified in this manual may cause
personal injury and/or damage to the equipment.
Follow Safety Instructions
Carefully read all safety messages in this manual and on your equipment safety signs.
Follow recommended precautions and safe operating practices.
Keep safety signs in good condition. Replace missing or damaged safety signs.
Decal Descriptions
DANGER : Electrical Hazard
Disconnect electrical power before inspecting or servicing equipment unless
maintenance instructions specifically state otherwise.
Ground all electrical equipment for safety.
All electrical wiring must be done by a qualified electrician in accordance with local
and national electric codes.
Ground all non-current carrying metal parts to guard against electrical shock.
With the exception of motor overload protection, electrical disconnects and over
current protection are not supplied with the equipment.
Introduction to Control
Expanded Backup Control Introduction to Control
MT1805A
5
The Chore-Tronics®
Expanded Back-up Control
contains relays that are pre-wired
for use with Backup Thermostats (Not Supplied). These relays are sized to conduct
the actual motor current in one line of the power to the Fans being backed up. Each
Relay can have a maximum of two independent 1hp loads wired to it.
Each Output Relay is wired to a Toggle Switch (Item 1, Figure 1). The Toggle
Switch allows the user to determine whether or not a fan or fans should turn on when
the back up thermostat that the fan is connected to turns on. There is also a toggle
switch that allows the user to determine if the Tunnel Curtain or the Sidewall Air Inlet
Doors open when Thermostat 1 turns on (Item 2, Figure 1).
2
1
Item Description
1 Toggle Switch (Fans)
2 Toggle Switch (Tunnel Curtain, Sidewall Inlets)
Figure 1. Toggle Switches
Danger !
Introduction to Control Expanded Backup Control
6
MT1805A
Never place all of the Toggle Switches associated with any one Thermostat in the
"Not Active" position. This will result in no Fans or Heat Zones turning on when the
Backup Thermostat turns on.
Thermostat functions
The Expanded Backup Control can have a maximum of 5 Backup Thermostats
connected to it.
Thermostat 1
When Thermostat 1 turns on, or if
the
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
Open
Tunnel
Inlet
24Vdc (Volts direct current) of
the electronic climate control is lost,
a maximum of four independent 1
hp loads will turn on. Also,
depending on the position of the
Toggle Switch, (Item 2, Figure 1),
either the Tunnel Curtain or the
Sidewall Inlet Doors will be given a
continuous open signal while the
close signal from the climate
control will be blocked.
Thermostats 2, and 3
Thermostats 2 and 3 will each turn on up to six independent 1 hp loads.
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
Thermostats 4, and 5
Thermostats 4 and 5 are used to back up heat zones. Each Thermostat can turn on up
to 4 one HP independent heat zones each.
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
1 hp
Load
Expanded Backup Control Introduction to Control
MT1805A
7
Switch Stickers
Remove the appropriate Switch Stickers (Item 1 Figure 2) from the Sticker Sheet, and
stick them on the front of the Control in the space provided to identify what Fans or
Heat Zones are wired to each Relay.
TM
Chore-Tronics
INLET
OPEN INLET
OPEN TUNNEL
ACTIVE
ACTIVE
NOT ACTIVE
ACTIVEACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
NOT ACTIVE
NOT ACTIVE
DOORS
NOT ACTIVE
ACTIVEACTIVE
NOT ACTIVE
NOT ACTIVE
THERMOSTAT 2
THERMOSTAT 1
THERMOSTAT 4
THERMOSTAT 3
NOT ACTIVE
NOT ACTIVE
NOT ACTIVE
NOT ACTIVE
ACTIVEACTIVE
NOT ACTIVENOT ACTIVE
BACKUP
CONTROL
EXPANDED
CAUTION!
RESET THERMOSTATS WHENEVER
SET TEMPERATURE IS CHANGED
61014&
Exh Fan Tun Fan Ht Zone
2
15
15
15
16
16
16
Tun Fan
Tun Fan
Tun Fan
Tun Fan
Tun Fan
Tun Fan
Exh Fan
Exh Fan
Exh Fan
Exh Fan
Exh Fan
Exh Fan
812
Ht Zone
4
Ht Zone
Ht Zone
Ht Zone
Ht Zone
Ht Zone
7113
48
48
12
12
37
37
11
11
&
&
&
&
&
&
13
13
13
14
14
Tun Fan
Tun Fan
Tun Fan
Tun Fan
Tun Fan
Exh Fan
Exh Fan
Exh Fan
Exh Fan
Ht Zone
Ht Zone
Ht Zone
Ht Zone
Ht Zone
51
62
26
10
10
51
115
&
&
&
&
&
9
9
9
2529-793
ACTIVEACTIVE
NOT ACTIVENOT ACTIVE
Exh Fan Exh Fan
Item Description
1 Front of the Control
2 Switch Sticker Sheet
3 Switch Sticker
Figure 1. Switch Stickers
2
1
3
Thermostat Temperature Settings
As with all backup systems that depend on mechanical Thermostats, it is essential
that the temperature settings of the Thermostats be adjusted close enough to the set
temperature to protect the livestock or poultry. Every time the set temperature of the
electronic control is changed, the Backup Thermostats must be adjusted
appropriately.
Danger !
Do not cross phase. The other leg of the power to the motors goes directly to the
motors.
The 24 VDC Input of this Back-up Box is meant to be connected to the 24 VDC
output of the control being backed up.
Wiring Diagrams
Inlet OPEN
L1 To Sidewall
Inlet CLOSED
L1 To Sidewall
L2 To Sidewall
L1 To Tunnel Curtain
L1 To Tunnel Curtain
L2 To Tunnel Curtain
Breaker
Sidewall
Circuit
Inlet
L1
L2
Circuit
Breaker
L1
Curtain
Tunnel
L2
Circuit
Breaker
Box
Backup
L2L1
CLOSE
OPEN
Inlet
I/O Board
24V From Control's
Control
Inlet
Open Close
Sidewall
Curtain
Open Close
Tunnel
8
Thermostat
Thermostat
Thermostat
12
11
10
9
Heat
#4
Thermostat
Thermostat
From Control's I/O Board
Input Power
3
7
6
4
5
2
1
L2
L1
9
10
8
5
7
6
4
3
GND
24V
Heat
#4
Heat
#4
Heat
#4
Heat
#4
Figure 2. Thermostats and Inlet Wiring
Expanded Backup Control Wiring Diagrams
MT1805A
8
Thermostats & Inlet Wiring
Wiring Diagrams Expanded Backup Control
9
MT1805A
Relay Wiring
L1 To Fan 1 (Or Heat Zone 1)
L1 To Fan 1 (Or Heat Zone 1)
Relay Example
(or Heat Zone 1)
L1 From Circuit Brkr of Fan 1
(or Heat Zone 2)
L1 From Circuit Brkr of Fan 2
Thermostat #4 Relays
Thermostat #5 Relays
Thermostat #3 Relays
Thermostat #1 Relays
Thermostat #2 Relays
Figure 3. Relay Wiring
Wiring Diagrams Expanded Backup Control
10
MT1805A
Internal Wiring #1
Figure 4. External Wiring #1
Expanded Backup Control Wiring Diagrams
MT1805A
11
Internal Wiring #2 (Thermostat and Toggle Switch)
Figure 5. External Wiring #2
Wiring Diagrams Expanded Backup Control
12
MT1805A
Part Numbers
Item Description Part No.
1 14 x 16 Electric Box 42684
2 14 x 16 Electric Box Lid (Not Shown) 42683
3 Switch Decal 2529-793
4 12 Pole Terminal Strip 34925
5 3 Terminal T9A Relay 42509
6 220 VAC Relay 34702
7 Toggle Switch 6014
8 SPST Toggle Switch 48173
9 Expanded Backup Top Plate 48120
10 Bottom Plate 48121
1
4
3
6
5
7
3
8
9 10
Figure 6. Part Numbers
Expanded Backup Control Wiring Diagrams
MT1805A
13
This Page Left Blank for Notes:
Wiring Diagrams Expanded Backup Control
14
MT1805A
Revisions to this Manual
Page No. Description of Change
New Book
Contact your nearby Chore-Tronics® distributor or representative for additional parts and information.
CTB Inc.
P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (877) 730-8825
E-Mail: ctb@ctbinc.com • Internet: http//www.ctbinc.com
Printed in the U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Chore-Time MT1805A CHORE-TRONICS® Expanded Backup Control Installation and Operators Instruction Manual

Type
Installation and Operators Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI