  • Hello! I am an AI chatbot trained to assist you with the Raychem NGC-CMA2 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
NGC-CMA2
INSTALLATION MANUAL
2 | nVent.com
CONTENTS
1. Product Overview .................................................................................................................................4
1.1. nVentRAYCHEMNGC-CMA2congurationandmonitoringsoftware. ..................................................................... 4
1.2. NGC-CMA2ProgrammingGuide .................................................................................................................................. 5
1.3. nVentRAYCHEMNGC-20HANDHELDSoftware–LicenseAgreement .................................................................... 5
1.4. UserResponsibilities .................................................................................................................................................... 7
1.5. SafetyWarnings ............................................................................................................................................................ 7
2. How to Run the NGC-CMA2 Program .................................................................................................... 8
3. Initial Setup of the unit .........................................................................................................................8
4. Using the NGC-CMA2 in Standard Mode ...............................................................................................8
4.1. InitialSetupoftheunitinStandardMode .................................................................................................................. 8
5. Changing the Language of the user interface screens. .......................................................................... 8
6. Temperature units ................................................................................................................................9
7. Establishing a Bluetooth connection between the NGC-CMA2 and NGC-20 control units ...................... 9
8. Conguring NGC-20 control units .......................................................................................................11
8.1. ChangingtheNGC-20controllersettings .................................................................................................................. 11
8.2. ChangingtheTemperaturesetpointofaNGC-20controlunit ............................................................................. 12
8.3. ChangingtheSwitchcontrolmode ............................................................................................................................ 13
8.4. ChangingNGC-20devicetagname ........................................................................................................................... 15
8.5. ChangingtheNGC-20consoleunits. ........................................................................................................................ 15
8.6. LoadShed/TemperatureSourceCommunicationstimeout ................................................................................. 16
8.7. SettingtheAutoCycleInterval. ................................................................................................................................. 16
8.8. AlarmOutputMode ..................................................................................................................................................... 17
8.9. SettingupLoadShedding .......................................................................................................................................... 17
9. Changing NGC-20 Temperature Settings and Temperature Alarms ..................................................... 19
9.1. ChangingNGC-20TemperatureSensorType(Sensor1). ....................................................................................... 19
9.2. SettingHighandLowTemperatureAlarmSetPoints(Sensor1) ............................................................................ 19
9.3. HighandLowAlarmFilter(Sensor1) ........................................................................................................................ 20
9.4. Deningwhichtemperatureinputisusedforcontrol .............................................................................................. 21
9.5. AssigningTemperaturesensorTagname ................................................................................................................. 22
9.6. SettingupFailSafemodeandHighLimitCut-OutSetpoint .................................................................................. 22
9.7. SettingtheHighLimitCut-OutSetpoint .................................................................................................................... 23
9.8. ConguringtheNGC-20TemperatureSources ......................................................................................................... 23
9.9. TemperatureSensorConguration ............................................................................................................................ 24
10. Electrical Settings ............................................................................................................................... 25
11. SIL 2 Safety Temperature Limiter Settings .......................................................................................... 28
11.1. ResettingtheSafetyTemperatureLimiter ................................................................................................................. 30
11.2. TripLimiter-TestfunctionforSILapprovedSafetyTemperaturelimiter ............................................................... 31
12. Maintenance data ............................................................................................................................... 32
12.1. ForceUserCongurationDefaults. ................................................................................................................... ......... 34
13. Alarm Masks ...................................................................................................................................... 35
14. NGC-20 Monitoring screens ...............................................................................................................37
15. NGC-20 Alarm screens. .....................................................................................................................40
nVent.com | 3
16. Firmware / Settings (communication settings) ................................................................................... 41
16.1. UpgradingrmwareoftheNGC-20controlunit ........................................................................................................ 41
16.2. ChangingtheserialinterfacesettingsoftheNGC-20controlunit ......................................................................... 43
16.3. NGC-20DisplayTest. ............................................................................................................................................... 43
16.4. NGC-20Modesettings ............................................................................................................................................... 43
17. Using the NGC-CMA2 in Mixed Mode .................................................................................................. 44
17.1. InitialSetupoftheunitinMixedMode ...................................................................................................................... 44
18. Changing main settings of the user interface screens ......................................................................... 45
18.1. Languages ................................................................................................................................................................... 45
18.2. Temperatureunits ...................................................................................................................................................... 45
19. Establishing connection between the NGC-CMA2 and NGC-20 control units ....................................... 46
20. Conguring NGC-20 control units ....................................................................................................... 48
20.1. ChangingtheNGC-20controllersettings .................................................................................................................. 48
20.2. ChangingtheTemperaturesetpointofaNGC-20controlunit ................................................................................ 49
20.3. ChangingtheSwitchcontrolmode ........................................................................................................................... 49
20.4. ChangingNGC-20devicetagname ........................................................................................................................... 51
20.5. LoadShedding ............................................................................................................................................................ 51
21. NGC-20 Temperature settings and temperature alarms ...................................................................... 53
21.1. ChangingNGC-20Temperaturesensortype(Sensor1) .......................................................................................... 53
21.2. FailSafemodeandHighLimitCut-OutSetpoint ..................................................................................................... 54
22. Electrical Settings ............................................................................................................................... 55
23. SIL 2 Safety Temperature Limiter Settings. ....................................................................................... 57
23.1. SafetyLimiterSetPoint .............................................................................................................................................. 58
23.2. ResettingSafetyTemperatureLimiter ....................................................................................................................... 59
23.3. TripLimiter................................................................................................................................................................... 59
24. Maintenance data ............................................................................................................................... 60
25. NGC-20 Monitoring screens ...............................................................................................................62
26. NGC-20 Alarm screens .......................................................................................................................63
27. Upgrading rmware of the NGC-20 control unit................................................................................... 64
28. Upload & Download conguration and monitoring data to & from NGC-20 via conguration le .......... 66
28.1 DownloadNGC-20CongurationandMonitoringdatafromcontroller ................................................................. 66
28.2 UploadNGC-20congurationintocontroller ............................................................................................................ 66
28.3 FormatCongurationFileNGC-20Controller ........................................................................................................... 67
28.4 CongurationleXMLdataformat .......................................................................................................................... 67
29. Appendices and Indexes .....................................................................................................................76
4 | nVent.com
1. PRODUCT OVERVIEW
ThisdocumentdescribestheuseandthecapabilitiesofthenVentRAYCHEMNGC-CMA2handhelddeviceandsoftware.Formore
informationaboutthecorrectuseandhandlingofthedevicewerefertoNGC-CMA2GettingStarted(INSTALL-131)manual.
1.1. nVent RAYCHEM NGC-CMA2 configuration and monitoring software.
TheNGC-CMA2isdevelopedforWindowsMobile5.ThesoftwareenablesnVentRAYCHEMNGC-20controlunitstobeconfigured
andmonitoredviaaWirelessBluetoothinterface.Theexactuseofthissoftwareisdescribedinthismanual.
Note:Forhazardousarea(Zone1,21andZone2,22usetheNGC-CMA2-EXonly)
TheNGC-20canbeconfiguredineitherStandardmodeorMixedmode.TheMixedmodemeetssituationswhereNGC-20is
communicatingwithanVentRAYCHEMNGC-UIT,otherwisetheNGC-20willbeconfiguredinStandardmode.Inbothcircumstances
adifferentsetofparametersisavailableforconfiguration.
Standard Mode with optional nVent RAYCHEM
Supervisor Software used as central user
interface
Mixed Mode with optional nVent RAYCHEM NGC-UIT used as
central user interface
NGC-20aslocalcontrollerinthefield.Supervisor
software(DTS)ascentralUserInterface.
NGC-20aslocalcontrollerinthefield.NGC-UITascentralUserInterface.
MONI-RMMUnitsareoptional
Figure 1 1: nVent RAYCHEM NGC-20 system overview
Configuration and Monitoring
TheNGC-CMA2canbeusedtoconfiguretheNGC-20.Besidesitsfunctionasprogramminginterfacethe
NGC-CMA2canalsobeusedtomonitorNGC-20unitswhiletheyareinoperation.Whenusedinmonitoringmode
allprocessvariablesusedbytheNGC-20controlunitscanbevisualisedonthescreenoftheNGC-CMA2.
Communications
NGC-CMA2devicessupportvarioustypesofcommunicationsinterfaces.Refertoproductdatasheetforcompletedetailsaboutall
communicationoptions.
nVent.com | 5
1.2. NGC-CMA2 Programming Guide
Vital Information
ThismanualisaguideforthesetupandoperationoftheNGC-CMA2handheldprogrammingdevices.
Important:Allinformation,includingillustrations,isbelievedtobereliable.Users,however,shouldindependentlyevaluatethe
suitabilityofeachproductfortheirparticularapplication.
nVentmakesnowarrantiesastotheaccuracyorcompletenessoftheinformation,anddisclaimsanyliabilityregardingitsuse.
nVent’onlyobligationsarethoseinthenVentStandardTermsandConditionsofSaleforthisproduct,andinnocasewillnVentorits
distributorsbeliableforanyincidental,indirect,orconsequentialdamagesarisingfromthesale,resale,use,ormisuseoftheproduct.
Specificationsaresubjecttochangewithoutnotice.Inaddition,nVentreservestherighttomakechanges—withoutnotificationto
Buyer—toprocessingormaterialsthatdonotaffectcompliancewithanyapplicablespecification.
1.3. nVent RAYCHEM NGC-20 HANDHELD Software – License Agreement
Thisagreementisalegalagreementbetweenyou,“theenduser”,andnVent,LLC(“nVent”).BYINSTALLINGOROTHERWISE
ACCESSINGTHISPROGRAM,YOUAREAGREEINGTOBECOMEBOUNDBYTHETERMSOFTHISAGREEMENT.IFYOUDONOT
AGREETOTHETERMSOFTHISAGREEMENT,DONOTINSTALLORACCESSTHISPROGRAM.IFINSTALLINGOROTHERWISE
ACCESSINGTHISPROGRAMBYOPENINGASEALEDDISKPACKAGE,PROMPTLYRETURNTHEUNOPENEDDISKPACKAGEAND
THEOTHERITEMS(INCLUDINGWRITTENMATERIALSOROTHERCONTAINERS)TOTHEPLACEWHEREYOUOBTAINEDTHEM.
GRANT OF LICENSE
ThenVentRAYCHEMNGC-20handheldSoftware(the“Software”)islicensed,notsold,toyouforuseonlyunderthetermsofthis
Agreement,andnVentreservesanyrightsnotexpresslygrantedtoyou.SubjecttothetermsandconditionsofthisAgreement,
nVentgrantstoyouanon-exclusive,nontransferable,lim¬itedlicense(withouttherighttosublicenseothers)tousetheonecopy,
includingwrittenmaterialsifany,oftheSoftwareonasinglecomputeratthelocation(companyandaddress)towhichnVentissued
thiscopyoftheNGC-20handheldSoftware.TheSoftwareisownedbynVentLLCandisprotectedbyUnitedStatescopyrightlaws
andinternationaltreatyprovisions.AllcopiesmadebyyouaresubjecttothetermsandconditionsofthisAgreement.Thestructure,
organisationandcodeoftheSoftwarearevaluabletradesecretsandconfidentialinformationofnVent.Youagreenottomodify,
alter,merge,adapt,duplicate,distribute,translate,decompile,disassemble,reverseengineer,createderivativeworks,copyfor
useonanyothercomputeroratanyotherlocation,orotherwisemakethissoftwareavailabletoanypersonorentityoutsidethis
location.TheSoftwareislicensedonlytoyou.Innoeventmayyoutransfer,sell,sublicense,rent,assignortransferrights,lease,or
otherwisedisposeoftheSoftwareonatemporaryorpermanentbasiswithoutthepriorwrittenconsentofnVent.Youagreetouse
reasonableeffortstoprotectagainsttheunauthorisedcopyinganduseoftheSoftwarebyothers.Youagreenottoremove,disable
orcircumventanyproprietarynoticesorlabelscontainedonorwithintheSoftware.
OTHER RESTRICTIONS
Youmaynotsublicense,rentorleasetheNGC-20handheldSoftwaretoanyone.
YouagreetonotifynVentpromptlyif“bugs”orseeminglyincorrectoranomalousbehaviourisdiscoveredwhenusingtheSoftware.
YouagreethattheNGC-20handheldSoftware,includingwrittenmaterials(ifany)andallcopiesinwholeorinpart,willbedestroyed
orreturnedtonVentatthewrittenrequestofthenVentProductManager.
ByinstallingorotherwiseaccessingtheNGC-20handheldSoftwareyouacknowledgethatyouhavereadandunderstoodnVent’
DisclaimerofWarrantyandLimitationofLiability,setforthbelow.
YouagreetousereasonableeffortstoprotectagainsttheunauthorisedcopyingandusetheNGC-20handheldSoftwarebyothers.
DISCLAIMER OF WARRANTY
THENGC-20HANDHELDSOFTWAREANDACCOMPANYINGWRITTENMATERIALSAREPROVIDED“ASIS”WITHOUTWARRANTY
OFANYKIND.THEENTIRERISKASTOTHERESULTSANDPERFORMANCEOFTHENGC-20HANDHELDSOFTWAREISASSUMED
BYYOU.NVENT DOESNOTWARRANTTHATTHEFUNCTIONSCONTAINEDINTHESOFTWAREWILLMEETYOURREQUIREMENTS
ORTHATTHEOPERATIONOFTHESOFTWAREWILLBEUNINTERRUPTEDORERROR-FREE,ORTHATPROGRAMDEFECTSWILLBE
CORRECTED.
LIMITED WARRANTY – MEDIA
THEMEDIUMONWHICHTHEPROGRAMISENCODEDISWARRANTEDTOBEFREEFROMDEFECTSINMATERIALAND
WORKMANSHIPUNDERNORMALUSEFORAPERIODOFSIXTY(60)DAYSFROMTHEDATEOFDELIVERYTOYOUASEVIDENCED
BYACOPYOFYOURRECEIPT.ALTHOUGHNVENT BELIEVESTHEMEDIAANDTHEPROGRAMTOBEFREEOFVIRUSES,THE
MEDIUMANDTHEPROGRAMARENOTWARRANTEDTOBEVIRUSFREE.NVENT LIABILITYANDYOUREXCLUSIVEREMEDYIF
THEMEDIUMISDEFECTIVEORINCLUDESANYVIRUSSHALLBEPROMPTREPLACEMENTOFTHEMEDIUMWITHANEWNGC-20
HANDHELDSOFTWAREPRE-ENCODEDDISC.
EXCLUSION OF ALL OTHER WARRANTIES
EXCEPTASEXPRESSLYPROVIDEDABOVE,NVENT DISCLAIMSALLWARRANTIES,EITHEREXPRESS,IMPLIEDORSTATUTORY,
INCLUDINGBUTNOTLIMITEDTOANYWARRANTYOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE,EVEN
IFNVENT HASBEENADVISEDOFSUCHPURPOSE.THISAGREEMENTGIVESYOUSPECIFICLEGALRIGHTS.SOMESTATESOR
COUNTRIESDONOTALLOWTHEEXCLUSIONOFWARRANTIESSOTHEABOVEEXCLUSIONMAYNOTAPPLYTOYOU.
6 | nVent.com
LIMITATION OF LIABILITY
THEENTIRERISKASTOTHERESULTSANDPERFORMANCEOFTHESOFTWAREISASSUMEDBYYOU.INNOEVENTSHALLNVENT, ITS
AFFILIATES,DIRECTORS,OFFICERS,SHAREHOLDERS,EMPLOYEESOROTHERREPRESENTATIVESBELIABLEFORDAMAGESOFANYKIND,
INCLUDINGWITHOUTLIMITATION,ANYLOSS,DAMAGE,ORDELAY,ORFORANYLOSTPROFITS,
LOSSOFUSE,INTERRUPTIONOFBUSINESS,ORFORANYCOMPENSATORY,SPECIAL,INCIDENTAL,CONSEQUENTIAL,INDIRECTDAMAGES
(HOWEVERARISING,INCLUDINGNEGLIGENCE)OFANYKINDARISINGOUTOFORINCONNECTIONWITHTHEUSEOF,ORTHEINABILITY
TOUSE,THESOFTWAREORTHISAGREEMENT(EVENIFNVENT HASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES).FURTHER,
IN NO EVENT SHALL NVENT ,ITSAFFILIATES,DIRECTORS,OFFICERS,SHAREHOLDERS,EMPLOYEESOROTHERREPRESENTATIVESBE
LIABLETOYOUINANAMOUNTGREATERTHANTHEAMOUNTACTUALLYPAIDBYYOU,IFANY,FORTHESOFTWARE.
YOUFURTHERAGREETHATREGARDLESSOFANYSTATUTEORLAWTOTHECONTRARY,ANYCLAIMORCAUSEOFACTIONARISING
OUTOFORRELATEDTOUSEOFTHESOFTWAREORTHETERMSANDCONDITIONSMUSTBEFILEDWITHINONE(1)YEARAFTER
SUCHCLAIMORCAUSEOFACTIONAROSEORBEFOREVERBARRED.
INDEMNITY
Totheextentallowedunderfederalandstatelaw,youagreetoindemnifyandholdnVent,itsparents,subsidiaries,affiliates,
officers,employees,sponsorsandpartnersharmlessfromanyclaim,loss,cost,expense,demand,ordamage,includingreasonable
attorneys’fees,arisingdirectlyorindirectlyoutof(a)youruseof,orinabilitytouse,theSoftware,(b)youractivitiesinconnection
therewith,or(c)yourbreachofthisAgreementorviolationoftherightsofanyotherparty.
TERMINATION
ThelicensegrantedhereinwillautomaticallyterminatewithoutnoticefromnVentifyoufailtocomplywithanytermorcondition
ofthisAgreement.Youagree,uponsuchtermination,toremovetheNGC-20handheldSoftwarefromanymemoryand/orstorage
mediaordevice,andtoreturntheNGC-20handheldSoftware,includingallmediaandwrittenmaterials,ordestroythesameand
certifysuchdestructiontonVent,alongwithanybackuporothercopiesinyourpossession.
COMPLETE AGREEMENT – MODIFICATION IN WRITING
ThisAgreementconstitutesthesoleandcompleteunderstandingbetweenthepartieswithrespecttotheNGC-20handheld
Softwareanditsuse,andmaynotbevariedexceptbyawritingsignedbyanofficerofnVent.Youagreethatyoumaynotrelyonany
representationsconcerningtheNGC-20handheldSoftwaretotheextenttheyvaryfromthisAgreement,andsuchrepresentations,if
any,willneitheraddtonorvarythetermsofthisAgreement.
CHOICEOFLAWS.ThisAgreementisgovernedbythelawsoftheStateofCaliforniaandtheUnitedStates,includingU.S.Copyright
Laws.
EXPORT LAWS
TheNGC-20handheldSoftwaremayrequirealicensefromtheU.S.DepartmentofCommerceorothergovernmentalagencybefore
itmaybeexported.Theterm“export”includesmanyacts(suchastransferringtheNGC-20handheldSoftwaretoaforeigncitizen
withintheUnitedStates),inadditiontosendingortakingtheNGC-20handheldSoftwareoutsidetheUnitedStates.Youagreeto
ascertainthenecessarylicensingproceduresandobtainanyrequiredlicensesbeforeexportingtheNGC-20handheldSoftware.
YoualsoagreetoindemnifynVentandassumeallfinancialresponsibilityforanylossesitmaysufferifyoudonotcomplywiththis
paragraph.
GOVERNMENT RESTRICTED RIGHTS
UseracknowledgesthattheNGC-20handheldSoft¬warehasbeendevelopedatprivateexpenseandisprovidedwith“Restricted
Rights.”Use,duplicationordisclosurebytheGovernmentissubjecttorestrictionsassetforthinsubparagraph(b)(3)andparagraph
(c)oftheRightsinTechnicalDataclauseat48C.F.R.252.227-7013,orsubparagraphs(c)(1)and(2)oftheCommercialComputer
Software–RestrictedRightsclauseat48C.F.R.52.227-19,asapplicable.ThisprovisionappliestotheNGC-20handheldSoftware
acquireddirectlyorindirectlybyoronbehalfofanygovernment.TheNGC-20handheldSoftwareisacommercialproduct,licensed
ontheopenmarketatmarketprices,andwasdevelopedentirelyatprivateexpenseandwithouttheuseofanygovernment
funds.Anyuse,modification,reproduction,release,performance,display,ordisclosureoftheNGC-20handheldSoftwarebyany
governmentshallbegovernedsolelybythetermsofthisAgreementandshallbeprohibitedexcepttotheextentexpresslypermitted
bythetermsofthisAgreement,andnolicensetotheNGC-20handheldSoftwareisgrantedtoanygovernmentrequiringdifferent
terms.
ASSIGNMENT
YoumayneitherassignanyrightnordelegateanyobligationunderthisAgreementandattemptedassignmentordelegationshallbe
void.nVentmayfreelyassignthisagreementanditsrightsandobligationsthereundertoanythirdparty.
INVALID PROVISIONS
IfanyoftheprovisionsofthisprovisionsAgreementareinvalidunderanyapplicablestatuteorruleoflaw,theyaretothatextent
deemedomitted.
WAIVER
NofailureordelayofnVentinexercisingorenforcinganyrightorprovisionofthisAgreementshallconstituteawaiverofsuchright
orprovision,oranyotherrightorprovisionhereunder.Furthermore,anywaiverbynVentofanyrightorprovisionofthisAgreement
shallnotbeconstruedas,orconstitute,acontinuingwaiverofsuchrightorprovision,orwaiverofanyotherrightorprovisionofthis
Agreement.
nVent.com | 7
HEADINGS
ThesectiontitlesinthisAgreementareforconvenienceonly.
SURVIVABILITY
YouagreethatthetermsandconditionsofthisAgreementshallsurviveanyterminationofthisAgreementandyourrightstousethe
Software.
Should you have any questions concerning this Agreement, or if you want to contact
nVent for any reason, please write to:
HOUSTON
7433HarwinDrive
Houston,TX77036
Tel:+1.713.868.4800
Fax:+1.713.868.2333
nVent.com
1.4. User Responsibilities
Theperformance,reliabilityandsafetyofyourheat-tracingsystemdependonproperdesign,selection,andinstallation.TheNGC-
CMA2willhelpyoutoconfigureandmonitorasystemthatmeetsyourrequirements,butitisonlyatool.Itassumesthatyourinput
isaccurate,thatyouarefamiliarwithheat-tracingsystemdesignandconfiguration,andthatyouwillensurethatallcomponents
oftheheat-tracingsystemareinstalled,maintainedandusedasintended.TheconfigurationoftheNGC-20handheldshouldbe
reviewedbyaknowledgeableengineertoensureitisappropriateforyourapplication.Additionalinformationrelatingtosafety,
design,andinstallationiscontainedinDesignGuides,InstallationManuals,DataSheets,andotherliteratureavailablefromnVent.
Besuretoconsultthesedocumentsasneeded.
1.5. Safety Warnings
ThereareimportantsafetywarningswhichareshippedwithnVentproductsandthatarealsoprintedinnVentRAYCHEMNGC-30
InstallationManual(INSTALL-112)andNGC-20installationmanual(INSTALL-130).Besuretoread,understandandfollowthese
safetywarningstoreducetheriskoffire,shock,orpersonalinjury.Ifyouhaveanyquestions,contactyourlocalrepresentativeor
contactnVentdirectly.
Warning, Error, and Alarm Messages
Undercertainconditions,theNGC-CMA2willalerttheuserwithawarninganalarmoranerrormessage.Thesearetypicallyeither
becausetheprogramcannotfindanacceptableanswerbasedonuserinput,orbecausetheusermayneedtotakesomeadditional
actiontoensurethedesignrequirementsarecompletelymet.Thesewarningsanderrormessagesaredetailedinchapter9ofthis
manual.
Forquestions,pleasecontactnVent’TechnicalSupport.
Technical Support
For technical support, contact your local representative, or contact nVent directly:
HOUSTON
7433HarwinDrive
Houston,TX77036
Tel:+1.713.868.4800
Fax:+1.713.868.2333
nVent.com
BELGIUM
Romeinsestraat14
3001Leuven
Tel:+32.16.213.511
Fax:+32.16.213.604
nVent.com
8 | nVent.com
2. HOW TO RUN THE NGC-CMA2 PROGRAM
3. INITIAL SETUP OF THE UNIT
Aftertheprogramisstartedthestartupscreenwillbevisualised.Thestartupscreenallowsuserstoconfiguretheunittotheir
personalneedsandprocessrequirementsviathesettingsicon.
4. USING THE NGC-CMA2 IN STANDARD MODE
WhenoperatedintheStandardModethemaximumsetofparametersareavailableforconfigurationandmonitoring.Thefollowing
chapterswilldescribeindetailhowtheNGC-20canbeconfiguredandbemonitoredviatheNGC-CMA2.
4.1. Initial Setup of the unit in Standard Mode
Aftertheprogramisstartedthestartupscreenwillbevisualised.Thestartupscreenallowsuserstoconfiguretheunittotheir
personalneedsandprocessrequirements.
Configuration Utility Main screen
Figure 4 1: Startup screen
Afterstartupoftheprogram,thesoftwarewillstartscanningfor
NGC-20controllers.
theSettingsiconwillallowtheusertochangethelanguageand
theengineeringunitsfortemperatures.
ByselectingtheNGC-20inthelisttheusercanconfigurethe
NGC-20controller.
TorescanforNGC-20controllersclichonthemagnifyingglass
atthebottomofthescreen.
5. CHANGING THE LANGUAGE OF THE USER INTERFACE SCREENS.
Configuration Utility Main screen
Figure 5 1: Setup Screen
About:showsthesoftwareversionoftheConfigurationUtility
Software.
Languages:Allowsselectingaconvenientlanguageoftheuser
interfacesoftware.
Temperature Units:SetsthetemperatureunitsoftheNGC-
CMA2.Supportedare:DegreesCelsiusanddegreesFahrenheit.
ThedefaultvalueisdegreesCelsius.
Back:Bringsyoubacktothepreviousscreen
(Figure4.1)
TaponLanguagestocontinue
nVent.com | 9
Figure 5 1: Setup Screen
Supported languages are:
English(default)
French(Français)
German(Deutsch)
6. TEMPERATURE UNITS
Figure 6 1: Temperature Units Screen
FromtheSettingsScreentaponTemperature Unitstochange
thewayinwhichtemperatureswillbedisplayedontheNGC-
CMA2screens.Thefactorydefaultsettingis°C.
Tappingonthedesiredfieldwillselecttheunitsofmeasure
Celsius or Fahrenheit andwillreturnyoutothe
SettingsScreen
whilethenewunitsofmeasurewillbeselected.
Taponback arrowtoreturntotheStartupScreen.
7. ESTABLISHING A BLUETOOTH CONNECTION BETWEEN THE NGC-CMA2 AND NGC-
20 CONTROL UNITS
Configuration Utility Main Screen
Figure 7 1: Main Screen
SelecttheNGC-20tobeconfigured.AnewscanforNGC-20
controllerscanbeinitiatedbyclickingonthemagnifyingglass.
10 | nVent.com
Bluetooth Discovery Process
Figure 7 2: Bluetooth Discovery screen –
Searching for devices
InbackgroundthedevicewillscanforallNGC-20controllers
whicharewithinrangeoftheBluetoothcommunications.
EnsurethatallNGC-20unitsarepoweredup.
Bluetooth Discovery Process (building the device inventory list)
Figure 7 3: Bluetooth Discovery screen –
one device found
Whensearchingiscompletealldevicesinrangewillbelistedon
thescreen.
Example:Forthisexample,theonlydevicethatisfoundisNGC-
20-1.Ifmorethanone
NGC-20controlunitisinrangeallunitswillbelistedonthe
screenasisshownonFigure7-3.
Bluetooth Discovery Process (selecting device)
Figure 7 4: Bluetooth Discovery screen –
nding 2 devices
Selectthedeviceyouwanttoconnecttobytappingonthe
devicename.Apop-upmessagewillappeartoconfirmthat
youwanttoconfiguretheNGC-20controller.Press"yes"to
continue.
Ifdevicesarenotshowinguprepeatthedevicediscovery
processbysimplytappingonthe magnifying glass.
nVent.com | 11
8. CONFIGURING NGC-20 CONTROL UNITS
InordertoconfiguretheconnectedNGC-20controlunittaponcontinue
NGC-20 Main Configuration Screen
Figure 8 1: Main screen
Themainscreensupportsdifferentoptionsasisshownon
Figure81.
Tap Configure:toconfiguretheselectedunit.
Tap Monitortolookatallprocessvariablesascurrently
activeonthisunit.Allmeasuredsensortemperatures,control
temperature,loadcurrent,supplyvoltage,groundfaultcurrent
andthestatusoftheSafetyLimiter.
Tap View Alarmsinordertogetanoverviewofallactivealarms
andtoresetalarms.
Tap Firmware / Settingsinordertoinstallanewversionof
firmwareintheselectedcontroller.
Tap Back to go backtotheBluetoothdiscoveryscreenas
shownonFigure7-3.
8.1. Changing the NGC-20 controller settings
BydefaulttheNGC-20Configurationscreenwillbeshown.TheNGC-20configurationscreensupportsdifferentoptions:
NGC-20 Configuration Screen
Figure 8 2: NGC-20 Conguration screen
Tap Controller Settingstoalter;setpoints,controlmode,dead
band,thedevicetagandloadshedding.
Tap Temperature SettingstoalterHighandLowTemperature
alarmvalues,thetemperaturealarmfilter,failsafemodeandto
enableandpresetthehighlimitCut-Out
Tap Temp. Source Settingstodefinethetemperaturesources
usedbythisNGC-20unit.
Tap Electrical Settingsinordertosetthehighandlowload
currentandvoltagealarmvalues.Thesecondscreenoffersthe
possibilitytoloadtherelaycyclestimecounterandtoadjustthe
groundfaultalarmwarningandtriplevel.
Tap Temperature Limiter;usethisentryinordertocontrolthe
Safetytemperaturelimitersetpoint,tripandresettheSafety
temperaturelimiterafterithastripped.
Tap Maintenancetogetinformationabouttheminimum
andmaximumvalueseverseenbytheunit.Ofthefollowing
variablestheminimumandmaximumarestored;Control
temperature,ACVoltage,Groundfaultcurrent,Loadcurrent,
Relaycyclecount,HeaterhoursinuseTimeandtheSafety
Limitertemperatures.
Tap Alarm Maskstospecifyforwhichvariablesanalarmwillbe
generated
Tap BackbringsyoutotheConfigurationscreen
12 | nVent.com
8.2. Changing the Temperature set point of a NGC-20 control unit
TaponControllerSettings.ThiswillopenanextscreenshowingtheactualControllersettings.Inordertochangeanyofthevalues,
taponthefieldholdingtheactualvariable.
Controller Settings
Figure 8 3: Controller Settings – Settings 1 screen
Taponthefieldholdingtheactualvalue(32°C).Anumerickey
padasshowninFigure84willpopup.
Numeric Input Screen (Temperature Set Point)
Figure 8 4: Temp Set point Numeric Screen
Enterthedesiredtemperaturesetpointbytappingonthescreen
andpressEntertocomplete.
- For this example,wewillbeusingasetpointof35ºC.As
soonasyoutaptheenterbuttonyouwillbebroughtbackto
theControllerSettingsscreen.
REMARK:Thenumericscreenisusedatvariousplaces
throughoutthismanualeverywherewherenumericvaluesareto
bechangedorentered.
nVent.com | 13
8.3. Changing the Switch control mode
WhenreturnedtotheControllerSettingscreenofFigure83ontheinputfieldunderSwitch Control Mode.
Switch Control Mode
Figure 8 5: Control Mode settings Screen
Theswitchcontrolmodedefinesinwhichmannertheoutput
switchwillbeoperatedinordertomaintainthedesired
temperature.TaponthedesiredSwitchControlMode.The
NGC-20supportsanumberofdifferentcontrolmodesasshown
onFigure85
Thedifferentcontrolmodessupportedare:
On / Off
Prop. Ambient Contactor
PASC contactor
Force On
Force OFF
Cancel
Notethatdependingontheselectedcontrolmodetheinput
fieldsinthepreviousandnextscreenswillvary.
CancelwillbringyoubacktotheControllerSettingsscreen
(Figure83).
Controller Settings 1 (On/Off)
Figure 8 6: Controller Settings 1
On/Offisasimplesetpoint/on-offoperation.
SetintheDead bandFieldthedesireddeadband.
NotethattheDeadbandwillbeabovesetpoint.
Example;asetpointof40°Canddeadbandof5willturnthe
heatingoffat45°Candonat39°C.
Controller Settings 1 (Prop. Ambient Contactor)
Figure 8 7: Controller Settings
Prop. Ambient Contactor:seePASCbelow.
PASC Contactortakesadvantageofthefactthattheheat
lossfromapipeisproportionaltothetemperaturedifference
betweenthepipeandtheambientair.Thisistrueregardlessof
heatertype,insulationtype,orpipesize.Oncetheheattracing
andinsulationonapipehasbeendesignedtobalanceheat
inputwithheatlossandmaintainaparticulartemperature,the
mainvariableincontrollingthepipetemperaturebecomesthe
ambientairtemperature.TheNGC-20hasacontrolalgorithm
thatusesthemeasuredambienttemperature,desiredmaintain
temperature,minimumambienttemperatureassumptionused
duringthedesignstage,andsizeofthesmallestpipediameter
tocalculatehowlongtheheatershouldbeonorofftomaintain
anear-constantpipetemperature.
Proportional Band:isthedeltabetweenthedesiredtemperature
(setpoint)andtheminimumexpectedambienttemperature.
TheProp. Ambient Cycle Timedefinesthetotaltimecycle
(SumoftheON+OFFcycle)inminutes.Thecycletimecan
beadjustedbetweenminimum10andMaximum255minutes.
TheON/OFFratiowillbecalculatedbasedonthemeasured
ambienttemperature.
14 | nVent.com
Figure 8 8: Controller Settings
ThePower Adjustment factor(min10%toMax200%)The
Poweradjustmentfactorcanbeusedtoinfluenceoroverride
thecalculatedON/OFFrationvaluesinexcessof100%willlead
tomoreheat,valuesbelow100%willreducethetemperature.
TapApplytoconfirmyournewsettings
Controller Settings 1 (Force ON / Force OFF)
Figure 8 9: Controller Settings
Force OnTherelayoutputispermanentlyswitchedon(user
override),turnsonthepowertotheheaterandleavesiton.
Force OFFTherelayoutputispermanentlyswitchedoff(user
override),turnsoffthepowertotheheater,andleavesitoff.
Note:RemembertomonitorthepipetemperaturesforLow/
HightemperaturealarmswhenselectingForceONorForceOFF
controlmode.
TapApplyafterthedesiredcontrolmodehasbeenselected.
nVent.com | 15
8.4. Changing NGC-20 device tag name
TaponSettings 2onthebottomofthecontrollersettingsscreen(Figure8-6tillFigure8-9).
Controller Settings 2
Figure 8 10: Controller Settings – Settings 2 screen
ThisscreenallowsyoutochangetheNGC-20devicetag.Tags
canbe39charactersinlengthandmaycontainallnumeric
characters.EnterthedesiredTagfortheNGC-20deviceby
tappingintheactualdevicetagorelsewhereinthatfield.(NGC-
20-1)
ConsoleUnits:fieldallowschangingthewaytemperatureunits
areshownontheNGC-20controlunits’display.Temperature
canbeshownindegreesFahrenheitorCelsius
Load Shed / Temperature Source Communications Timeout
NGC-20 Tag
Figure 8 11: Temp Set point Numeric Screen
EnterthedesiredTagbyusingtheonscreenkeyboard.TapOK
whenfinished.
- For this example, thenewtagwillbe“Pipe#1”.
8.5. Changing the NGC-20 console units.
TaponthefieldConsoleunitstochangethereadoutoftheNGC-20Controlunitsdisplay.
Console Units
Figure 8 12: NGC-20 Console Units screen
Taponthedesiredconsoleunits.
16 | nVent.com
8.6. Load Shed / Temperature Source Communications time out
Loadsheddingisacontrolmodethatcanbeprogrammedandinitiatedonlybyanexternalcommunicatingdevice,whichoverrides
temperaturecontrolandforcestheoutputofthecontrollerOFFuntiltheoverrideisremoved.Whenusinganexternaldevice
(SupervisorSoftwareoraDCS),aloadsheddingcommandiscontinuallybroadcastoverthecommunicationsnetwork.
Whenpowerisapplied,thecontrollerdelaysenergisingitstraceby‘x’numberofseconds,where‘x’isequaltothelastdigitinits
networkaddress.Iftheloadshedfunctionisenabled,thecontrollerwillgointoloadshedmodebeforeitturnsitsoutputon.Itwill
thenlookforthebroadcastedloadshedcommand.Ifthecontrollerreceivestheloadshedcommandbeforeittimesout,itwill
remaininloadshedmode,andtheoutputwillremainoffaslongasthemodulereceivesaregularbroadcastofthecommand.If
thecontrollerdoesnotreceivetheloadshedcommandwithinthetimeoutperiod,itwillenergiseitsoutputandresumenormal
operation.Thetimingofthisbroadcast(andthetimeoutvalue)canvarybetween30secondsand10minutes.Atotalof16different
loadsheddingzonescanbedefined.
EnterconfirmsthenewsettingsandreturnstoFigure8-10ControllerSettings–Settings2screen.
Figure 8 13
8.7. Setting the Auto Cycle Interval.
TaponSettings3onthebottomofthecontrollersettingsscreenofFigure8-6tillFigure8-10
Controller Settings 3
Figure 8 14: Controller settings - Settings 3 screen
ThisscreenallowsyoutochangetheNGC-20devicetag.Tags
canbe39charactersinlengthandmaycontainallnumeric
characters.EnterthedesiredTagfortheNGC-20deviceby
tappingintheactualdevicetagorelsewhereinthatfield.
(NGC-20-1)
ConsoleUnits:fieldallowschangingthewaytemperatureunits
areshownontheNGC-20controlunits’display.Temperature
canbeshownindegreesFahrenheitorCelsius
Load Shed / Temperature Source Communications Timeout
nVent.com | 17
8.8. Alarm Output Mode
TheAlarmOutputModedefinesthewaythealarmrelaywillactincaseofalarms.Thedifferentoptionsare:NormalOperation,
Toggle,Flashorcancel.
Alarm Output Mode
Figure 8 15: Alarm Output Mode
Normal operation:Selectingthiswillresultinthealarmrelay
changingstateincaseofanalarm.(Generalalarm)Thismeans
theopencontactwillcloseandtheclosedcontactoftheSPDT
alarmrelaywillopen.
Toggle:selectingtogglewillcausetheAlarmrelaytochange
stateeachtimeanewalarmcomesup.
Flash:selectingtoFlashtheAlarmrelaywillalternativelyopen
andclosetheAlarmrelay.Theintervalitselfcanbeuserdefined
intheAlarmOutputToggleTime
Cancelwilltakeyoubacktothepreviousscreenwithoutanyof
thechangesmade.
8.9. Setting up Load Shedding
A total of 16 different load shedding zones can be defined.
Load Shedding 1
Figure 8 16:Controller Settings, Load Shedding 1
Ifaloadsheddingcommandispresent,thecontrollerwill
continuetoholdtheoutputOFF,untiloneoftwoconditions
occurs:
1.Thezonedefinitionflagsofanexternalcommunicating
devicewhichinitiatedloadsheddingclearsandthecommand
toterminateloadsheddingmodeisissued.
2.Communicationsareinterruptedbetweenthe
controlleranditscommunicatingdevice,asin
thecaseofadamagedcommunicationswire.If
c o m m u n i c a t i o n c e a s e s f o r a s p e c i f i e d t i m e o u t v a l u e , 
thecontrollerwillreturntonormaloperation.Thevalueforthis
timeoutisprogrammablewithinthecontroller(30secondsto
600seconds).
Note:Thecontrollerwillreturntonormaloperationif
communicationsbetweentheexternalcommunicatingdevice
andthecontrolleraredisruptedinanyway.Thiswillreturn
temperaturecontroltotheHTC.Also,theHTCdoesnotperform
aperiodicautocycletestwhileoperatinginloadshedmode.
18 | nVent.com
Load Shedding 2
Figure 8 17: Controller Settings, Load Shedding 2
Threeparametersmustbesetinthecontrollertoconfigureitfor
loadsheddingoperation:
1.Theloadsheddingfeaturemustbeenabled.
2.TheFAILSAFEMODEparametermustbeenabledordisabled
dependingontheapplicationrequirements.IfFAILSAFEMODE
isenabled,thenatleastoneLOWTSALARM(ofaTSusedinthe
TSCONTROLMODE)mustbeenabled.Ifthealarmtemperature
exceedstheCONTROLSETPOINTtemperature,fail-safemodewill
bedisabled.
3.Thezonedefinitionflagsofanexternalcommunicatingdevice
thataretobeassociatedwiththeloadsheddingactionforthe
controllermustbedefined.TheNGC40controllerwillsupportupto
16differentzones.
Theseparameterscanonlybeconfiguredusinganexternal
communicatingdeviceconnectedtothebridgeorUIT.
Notes:
•Fail-safemodeisalwaysdisabledifthe
 SWITCHCONTROLMODEissettoeitherofthe
 twoproportionalambientcontrolmodes,ortheTS
 CONTROLMODE=EXTINPUT,FAILOFF/ON
•TheHTCwillturnonitsoutputswitchwhenthe
 controltemperaturebecomeslessthanthehighest
 LOWTSALARMtemperatureifthefollowing
 conditionsaremet:
–Fail-safemodeisenabled
–Loadsheddingisactive
–TheTSCONTROLMODEusesbothTS1andTS2
BothTS1andTS2havetheirLOWTSALARMSenabled
•AFORCEONoverridesignalhashigherprioritythan
 aloadsheddingsignal.AnINHIBITsignalhashigher
 prioritythanfailsafemode.
TappingtheBackbuttonbringsyoubacktotheNGC-20
configurationscreen(Figure82:NGC-20Configurationscreen)
nVent.com | 19
9. CHANGING NGC-20 TEMPERATURE SETTINGS AND TEMPERATURE ALARMS
OntheNGC-20Configurationscreen(Figure91)taponTemperatureSettings.
Figure 9 1: NGC-20 Conguration screen
9.1. Changing NGC-20 Temperature Sensor Type (Sensor 1).
Thefirstscreenofthetemperaturesettingsscreenenablesconfigurationofthesensors.TheNGC-20controlunitsupportsonlyone
typeoftemperaturecontrolinput(Pt100-3-wire)
Temperature Settings Sensor 1
Figure 9 2:Temperature Settings: Sensor 1 screen
ThefirstfieldTemperature sensor 1 Typeoffersonlytwo
optionseither
“3wire100OhmPlatinum
or
“NotUsed”
onlyuse
Notused
whenthereisnotemperaturesensorconnectedtothis
input.
9.2. Setting High and Low Temperature Alarm Set Points (Sensor 1)
High / Low Alarm Set point Sensor 1
Figure 9 3:Temperature Settings: Sensor 1 screen
High Alarm Set Point
Enterinthisfieldthevalueatwhich-whenexceeded-you
wanttheNGC-20controlunittogenerateahightemperature
alarm.ThisHighTemperatureconditionwillbemonitoredby
TemperaturesensorT1only.
Low Alarm Set Point
Enterinthisfieldthevalueatwhich-whenexceeded-you
wanttheNGC-20controlunittogenerateaLowTemperature
Alarm.ThisLowTemperatureconditionwillbemonitoredby
TemperaturesensorT1only.
20 | nVent.com
9.3. High and Low Alarm Filter (Sensor 1)
High and Low Alarm Filter Sensor 1
Figure 9 4: Temperature Settings: Sensor 1 screen
Alarm filterscanbeseenasanalarmdelay.Thismeansthat
whenthetemperaturedropsbelowtheLowAlarmSetpointthe
NGC-20Controlunitwillonlytriggeranalarmwhenthevalue
enteredintheLowAlarmFilteristimedout.Thismeansthatif
immediateactionofthealarmoutputisrequired,theLowAlarm
Filtervalueshouldbesetat0sec.Anyothervaluewillresultin
adelay.TheoperationoftheHighAlarmFilteristhesame.Min
0toMax59940secondsforSensor2inordertoconfigurethe
secondtemperatureinputconnectedtotheNGC-20controlunit.
HitApplywhendone.TheBackbuttonwillbringyoubacktothe
NGC-20ConfigurationscreenofFigure82.
/