The Lutron PAM-9212SD Pitot Tube Anemometer with SD Card Data Logger is a versatile and accurate instrument designed for measuring air velocity and pressure. With its advanced features and user-friendly interface, it's ideal for various applications in industrial, laboratory, and environmental settings. Key capabilities include:

  • Air Velocity Measurement: Measures air velocity in multiple units (m/s, km/h, FPM, mph, knots) with high accuracy and a wide measurement range (4.1 to 100 m/s).

  • Differential Pressure Measurement: Accurately measures differential pressure up to ±200 mbar with selectable display units (mbar, psi, Kg/cm2, mm Hg, inch Hg, meter H2O, hPa, kPa, inch H2O, and Atmosphere).

The Lutron PAM-9212SD Pitot Tube Anemometer with SD Card Data Logger is a versatile and accurate instrument designed for measuring air velocity and pressure. With its advanced features and user-friendly interface, it's ideal for various applications in industrial, laboratory, and environmental settings. Key capabilities include:

  • Air Velocity Measurement: Measures air velocity in multiple units (m/s, km/h, FPM, mph, knots) with high accuracy and a wide measurement range (4.1 to 100 m/s).

  • Differential Pressure Measurement: Accurately measures differential pressure up to ±200 mbar with selectable display units (mbar, psi, Kg/cm2, mm Hg, inch Hg, meter H2O, hPa, kPa, inch H2O, and Atmosphere).

SD card real time Data Recorder
200 mbar, differential manometer
PITOT TUBE ANEMOMETER
Model : PAM-9212SD
Your purchase of this
PITOT TUBE ANEMOMETER
with SD CARD DATA LOGGER
marks a step forward for you
into the field of
precision measurement.
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
TABLE OF CONTENTS
1. FEATURES......................................................................................................
1
2. SPECIFICATIONS...........................................................................................
2
2-1 General Specifications.........................................................................................
2
2-2 Electrical Specifications........................................................................
4
3. FRONT PANEL DESCRIPTION...........................................................................
7
4. MEASURING PROCEDURE.......................................................................
8
5. DATALOGGER...................................................................................................
12
5-1 Preparation before execute datalogger function........................................................
12
5-2 Auto Datalogger ( Set sampling time
1 second )........................................................
12
5-3 Manual Datalogger ( Set sampling time = 0 second )........................................................
13
5-4 To check the time and sampling time information........................................................
14
5-5 SD Card Data structure................................................................................................................
14
6. Saving data from the SD card to the
computer ( EXCEL software )……………………………………………………........................................................
……………………………....
16
7. ADVANCED SETTING...............................................................................
18
7-1 Set clock time ( Year/Month/Date,Hour/Minute/ Second )…………………
18
7-2 Set sampling time ( Hour/Minute/ Second )……………………………………………….
19
7-3 Auto power OFF management………………………………………………..
19
7-4 Set beeper sound ON/OFF……………………………………………………
20
7-5 Decimal point of SD card setting………………………………………….
20
7-6 SD memory card Format………………………………………………………
21
7-7 Air density……………………………………………………………………
21
8. POWER SUPPLY from DC ADAPTER.....................................................
22
9. BATTERY REPLACEMENT..........................................................................
22
10. SYSTEM RESET............................................................................................
22
11. RS232 PC SERIAL INTERFACE....................................................................
23
12. OPTIONAL ACCESSORIES...................................................................
25
13. PATENT.........................................................................................................
26
1 FEATURES
* Pitot tube Anemometer measurements for Air Velocity .
* Dual & differential input, ± 200 mbar max. range.
* Application : Industrial, laboratory, heating,
ventilation, medical hospital, used for air or not
corrosive and not ionized gas.
* Sensor is built inside the housing.
* Single plugs for pipe connection.
* Measurement units:
Air vilocity : m/s, km/h, FPM, mph, knots
Air pressure: 10 kind display units ( mbar, Kg/cm
2
, mm Hg, meter H2O
Atmosphere, psi, inch Hg, inch H2O, hpa , kpa ) select
by push button on the front panel
* Auto shut off saves battery life.
* Zero button on the front panel, easy to offset the
zero value.
* Microprocessor circuit assures maximum possible
accuracy, provides special functions and features.
* Super large LCD display
for best viewing angle.
*
No need setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card
into the computer, it can download the all the measured
value with the time information ( year/month/date/
hour/minute/second ) to the Excel directly, then user can
make the further data or graphic analysis by themselves.
*
SD card capacity : 1 GB to 16 GB.
*
LCD with green light backlight, easy reading.
*
It can default auto power off or manual power off.
*
Data hold, record max. and min. reading.
*
Microcomputer circuit, high accuracy.
*
Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
*
RS232/USB PC COMPUTER interface.
1
2. SPECIFICATIONS
2-1 General Specifications
Circuit
Custom one-chip of microprocessor LSI
circuit.
Display
LCD size : 51 mm x 37 mm
LCD with green backlight ( ON/OFF ).
Display units Air vilocity : m/s, km/h, FPM, mph, knots
Air pressure: psi , inch Hg , inch H2O , h PA , kPA
mbar, Kg/cm
2
, mm Hg , meter H2O
, Atmosphere.
Measurement
Air vilocity & Dual differential input, data hold,
Function
zero/relative, memory.
Zero adjust Push button on the front panel.
Sensor * Sensor is built inside the housing.
* Piezoelectric sensor.
*
Used for dry, non-corrosive and
non-ionic air and gas only.
Liquid is prohibited.
Datalogger
Auto
1 sec to 8 Hours 59 Minutes 59 sec.
Sampling Time
@ Sampling time can set to 1 second,
Setting range
but memory data may loss.
Manual
Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Data error no.
0.1 % no. Of total saved data typically.
Memory Card
SD memory card. 1 GB to 16 GB.
Advanced
* Set clock time (Year/Month/Date,Hour/Minute/ Second )
setting
* Set sampling time
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* SD memory card Format
* Air density setting
2
Data Hold
Freeze the display reading.
Memory Recall
Maximum & Minimum value.
Sampling Time
Approx. 1 second.
of Display
Data Output
RS 232/USB PC computer interface.
*
Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
*
Connect the optional USB cable
USB-01 will get the USB plug.
Operating
Meter
0 to 50
.
Temperature
Operating
Less than 85% R.H.
Humidity
Power Supply
* AC/DC power adapter is optional.
Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
* AC/DC power adapter is optional.
DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current
Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 7 mA.
When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 25 mA.
* AC/DC power adapter is optional.
If LCD backlight on, the power
consumption will increase approx.
10 mA.
Weight
265 g / 0.59 LB. (without battery)
Dimension
Meter
190 x 68 x 45 mm
(7.5 x 2.7x 1.8 inch)
Accessories
* Instruction manual...............................
...................
1 PC.
Included
* Plug for quick coupler................................. 2 PCs.
*
Pito tube 018..................................................................
1 PC.
*
Silicon Soft tube 01( 50 cm )..................................................................
2 PCs.
3
Optional
SD memory card
Accessories
AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
2-2 Electrical Specifications (23±5
)
Air velocity
Measurement Range Resolution Accuracy
m/s 4.1 to 100.0 m/s 0.1 m/s ±( 3% + a )
reading
Km/h 14.7 to 360.0 km/h 0.1 Km/h
or
Mile/h 9.1 to 223.7 mph 0.1 mph ±( 1% + a )
( mph ) full scale
Knot 7.9 to 194.3 knot 0.1 Knot
*Air density
Ft/min 81-19685 ft/min 1 Ft/min :1.200
@ a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min
Note:
m/s - meters per second km/h - kilometers per hour
ft/min - feet per minute knot - nautical miles per hour
mile/h - miles per hour (international knot)
4
Manometer
Unit Max. range Resolution
mbar ± 200 mbar 1 mbar
psi ± 2.9 psi 0.1 psi
Kg/cm
2 ± 0.2
Kg/cm
20.001
Kg/cm
2
mm Hg ± 150.0 mm Hg 1 mm Hg
inch Hg ± 5.91 inch Hg 0.01 inch Hg
meter H2O ± 2.040 meter H2O0.01 meter H2O
h PA ± 200 h PA1h PA
K PA ± 20 K PA 0.01 K PA
inch H2O ± 80.2 inch H2O0.05 inch H2O
Atmosphere ± 0.2 Atmosphere 0.001 Atmosphere
Unit Max. range Accuracy
mbar ± 200.0 mbar ± 2 % F. S.
psi ± 2.900 psi
Kg/cm
2 ± 0.204
Kg/cm
2Note :
mm Hg ± 150.0 mm Hg *23
± 5
.
inch Hg ± 5.905 inch Hg * F.S. : full scale
meter H2O ± 2.040 meter H2O* Included linearity,
h PA ± 200.0 h PAhysteresis and
K PA ± 20.00 K PA repeatability
inch H2O ± 80.20 inch H2O
Atmosphere ± 0.197 Atmosphere
5
Remark :
Measuring Display unit
unit
psi PSI
inch Hg In Hg
inch H2OIn H2O
h PA h PA
KPA _ PA
mbar - bAr
Kg/cm
2
_ g C2
mm Hg - - Hg
meter H
2
O
-
t
H2O
Atmosphere AtP
6
3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display 3-12 RS-232 Output Terminal
3-2 Power Button
3-13 Reset Button
3-3 Hold Button / Backlight Button
3-14 DC 9V Power Adapter Input Socket
3-4 REC Button 3-15 Battery Compartment/Cover
3-5 UNIT Button , Button 3-16 Battery Cover Screws
3-6 Function Button , Button 3-17 Stand
3-7 Set Button , Time Button 3-18 Tripod Fix Nut
3-8 Log Button , Enter Button 3-19 Plug/quick coupler
3-9 P1 Input Socket 3-20 Pitot Tube
3-10 P2 Input Socket 3-21 soft tube
3-11 SD card socket 3-22 soft tube
7
4. MEASURING PROCEDURE
A.Air vilocity
1)
Power ON the meter by pressing the " Power Button "
( 3-2, Fig. 1 ) for at least 1.5 seconds.
*
Pressing the " Power Button " ( 3-2, Fig. 1 ) continuously and
> 1.5 seconds again will turn off the meter.
2)
pressing and holding the " Function Button " ( 3-7, Fig. 1 ) to
Select to Air vilocity Function.
3)
pressing and holding the " Unit Button " ( 3-5, Fig. 1 ) to
Select the desired Air vilocity units (m/s, Ft/min, Km/h, Knot, Mile/h)
4)
Zero adjusting
pressing and holding the the "
Button " ( 3-5, Fig. 1 ) and
"
Button " ( 3-6, Fig. 1 ) for at least 1.5 seconds to
the display reading will show zero .
5)
Pitot tube, sensing soft tube ( 3-22, Fig. 1 ) Install to
P1 Input Socket ( 3-9, Fig. 1 ),and sensing soft tube ( 3-21, Fig. 1 )
Install to P2 Input Socket ( 3-10, Fig. 1 )
6)
The meter is build the two input socket ( P1 input socket,
P2 input socket) for accepting the Pitot tube sensing Air speed
input, The LCD will show the measuring Air vilocity value.
8
B. Manometer
1)
Power ON the meter by pressing the " Power Button "
( 3-2, Fig. 1 ) for at least 1.5 seconds.
*
Pressing the " Power Button " ( 3-2, Fig. 1 ) continuously and
> 1.5 seconds again will turn off the meter.
2)
pressing and holding the " Function Button " ( 3-7, Fig. 1 ) to
Select to manometer Function.
3)
pressing and holding the " Unit Button " ( 3-5, Fig. 1 ) to
Select the desired manometer units ( mbar, , Kg/cm^2 , mm Hg
meter H2O, Atmosphere, psi , inch Hg , inch H2O, hPA , kPA )
4)
Zero adjusting
pressing and holding the "
Button " ( 3-5, Fig. 1 ) and
"
Button " ( 3-6, Fig. 1 ) for at least 1.5 seconds to
the display reading will show zero .
5)
Install the measuring pipe to " Plug/quick coupler "
( 3-19, Fig. 1 ).
6)
The meter is build the two input socket ( P1 input socket,
P2 input socket) for accepting the differential pressure
input.
Connecting the pipe along the " Plug " ( 3-19, Fig. 1) to
a.
" P1 input socket " ( 3-9, Fig. 1 ) only
b.
" P2 input socket " ( 3-10, Fig. 1 ) only
c.
Both P1 & P2 input socket
The LCD will show the measuring pressure value.
Note :
*
If the P1 pressure > P2 pressure, the display will
get positive reading.
*
If the P1 pressure < P2 pressure, the display will
get negative reading.
9
REMARK:
Pressure quick connector use :
1)connect with the meter pressure quick connector, you can insert directly.
2)To disengage from the meter, the pressure quick connector has a slide device,
slide it to the last position, then Pull out.
7) Data Hold
During the measurement, press the " Hold Button " ( 3-3,
Fig. 1 ) once will hold the measured value & the LCD will
display a " HOLD " symbol.
Press the " Hold Button " once again will release the data
hold function.
8) Data Record ( Max., Min. reading )
1)
The data record function records the maximum and
minimum readings. Press the " REC Button " ( 3-4, Fig.
1 ) once to start the Data Record function and there
will be a " REC " symbol on the display.
2)
With the " REC " symbol on the display :
a)
Press the " REC Button " ( 3-4, Fig. 1 ) once, the
" REC MAX " symbol along with the maximum value
will appear on the display.
b)
Press the " REC Button " ( 3-4, Fig. 1 ) again, the
" REC MIN " symbol along with the minimum value
will appear on the display.
c)
To exit the memory record function, just press the
" REC " button for 2 seconds at least. The display will
revert to the current reading.
9) LCD Backlight ON/OFF
After power ON, the " LCD Backlight " will light
automatically. During the measurement, press the
" Backlight Button " ( 3-2, Fig. 1 ) once will turn OFF the
" LCD Backlight ".
Press the " Backlight Button " once again will turn ON the
" LCD Backlight " again.
10
10)
For quick measurement, follow the procedures
shown below :
Main procedures :
POWER ZERO ADJUST
ON
DETERMINE UNIT
Optional measuring procedures :
DATA HOLD MEMORY RECORD RS232 OUTPUT
Max., Min.
datalogger function
Auto datalogger function or Manual datalogger function
Power management
AUTO POWER OFF or MANUAL POWER OFF
(Not activated during
Memory Record Selection)
11
5. DATALOGGER
5-1 Preparation before execute datalogger function
a. Insert the SD card
Prepare a " SD memory card "( 1 GB to 16 GB, optional )
insert the SD card into the "SD card Socket" ( 3-11, Fig. 1 ).The front
panel of the SD card should face against the down case.
* It recommend use memory card capacity is
4 GB.
b. SD card Format
If SD card just the first time use into the meter, it recommend to
make the " SD card Format " at first,please refer chapter 7-6, page21.
* If the SD card exist the trouble during format by the meter,
use the computer to reformat again can fix the problem.
c. Time setting
If the meter is used at first time, it should to adjust the
clock time exactly, please refer chapter 7-1, page 18.
d. Decimal format setting
The numerical data structure of SD card is
default used the " . " as the decimal, for
example "20.6" "1000.53" . But in certain
countries ( Europe ...) is used the " , " as the
decimal point, for example " 20, 6 "
"1000,53". Under such situation, it should
change the Decimal character at first, details
of setting the Decimal point, refer to Chapter
7-5, page 20.
5-2 Auto Datalogger ( Set sampling time
1 second )
a. Start the datalogger
Press the " LOG Button ( 3-8, Fig. 1 ) > 1.5 seconds
continuously, the LCD will show the text of " DATALOGGER "
indicator and flashing per sampling time, at the same
time the measuring data along with the time information will
be saved into the memory circuit.
12
Remark :
*
How to set the sampling time, refer to Chapter 7-2 ,
page 19 .
*
How to set the beeper sound is enable, refer to
Chapter 7-4, page 20 .
b. Pause the datalogger
During execute the Datalogger function, if press the
" LOG Button " ( 3-8, Fig. 1 ) once will pause the
Datalogger function ( stop to save the measuring data
into the memory circuit temporally ). In the same time
the " DATALOGGER " symbol will stop flashing.
Remark :
If press the " LOG Button " ( 3-8, Fig. 1 ) once again
will execute the Datalogger again, the " DATALOGGER "
symbol will flashing.
c. Finish the Datalogger
During execute the Datalogger function, press the
" LOG Button ( 3-8, Fig. 1 ) > 1.5 seconds continuously
again will finish the Datalogger function, the " DATALOGGER "
text will be disappeared and finish the Datalogger function.
5-3 Manual Datalogger ( Set sampling time = 0 second )
a. Set sampling time is to 0 second
Press the " LOG Button ( 3-8, Fig. 1 )>1.5 seconds, the LCD
will show the indicator " DATALOGGER " and " Position no. " symbol
then press the " LOG Button " ( 3-8, Fig. 1 ) once , the
" DATALOGGER " symbol will flashing once and Beeper will sound
once at the same time the measuring data along with the time
information will be saved into the memory circuit .
13
Remark :
During execute the Manual Datalogger, it can use the "
Button " ( 3-5, Fig. 1) or "
Button " ( 3-6, Fig. 1 ) to
set the measuring position ( 1 to 99, for example room 1
to room 99 ) to identify the measurement location , the
lower Display will show P x ( x = 1 to 99 ).
b. Finish the Datalogger
During execute the Datalogger function, press the " LOG
Button ( 3-8, Fig. 1 ) > 1.5 seconds continuously again will
finish the Datalogger function, the Position no. " PXX " will
be disappeared and finish the Datalogger function.
the " DATALOGGER " indication will be disappeared and finish
the Datalogger.
5-4 To check the time and sampling time information
During the normal measurement , If press " Time " ( 3-7, Fig. 1 )
once , the LCD display will present the time information of
Year/Month/Date , Hour/Minute/Second
and the Sampling time information .
5-5 SD Card Data structure
1) When the SD card is used into the meter, the SD card
When the first time, the SD card is used into the meter,
the SD card will generate a route :
PMA01
2)
If the first time to execute the Datalogger,
under the route PMA01\, will generate a new
file name PMA01001.XLS.
After exist the Datalogger, then execute again,
the data will save to the PMA01001.XLS until
Data column reach to 30,000 columns, then
will generate a new file, for example PMA01002.XLS
14
3)
Under the folder PMA01\, if the total files more
than 99 files, will generate anew route, such as
PMA02\ ........
4)
The file's route structure :
PMA01\
PMA01001.XLS
PMA01002.XLS
.....................
PMA01099.XLS
PMA02\
PMA02001.XLS
PMA02002.XLS
.....................
PMA02099.XLS
PMAXX\
.....................
.....................
Remark :
XX : Max. value is 10.
15
6. Saving data from the SD card
to the computer ( EXCEL software )
1)
After execute the Data Logger function, take away the
SD card out from the " SD card socket " ( 3-11, Fig. 1 ).
2)
Plug in the SD card into the Computer's SD card slot
( if your computer build in this installation ) or
insert the SD card into the " SD card adapter ". then
connect the " SD card adapter " into the computer.
3)
Power ON the computer and run the " EXCEL software ".
Download the saving data file ( for example the file
name : PMA01001.XLS, PMA01002.XLS ) from the SD
card to the computer. The saving data will present into
the EXCEL software screen ( for example as following
EXCEL data screens ) , then user can use those EXCEL
data to make the further Data or Graphic analysis
usefully.
EXCEL data screen ( for example )
16
EXCEL graphic screen ( for example, graphic )
17
7. ADVANCED SETTING
Under do not execute the Datalogger function,
press the " SET Button " ( 3-7, Fig. 1 ) continuously at
least two seconds will enter the " Advanced Setting " mode.
then press the " SET Button " ( 3-7, Fig. 1 ) once a while
in sequence to select the six main function, the
display will show :
DAT
E.....
.................
Set clock time ( Year/Month/Date, Hour/Minute/
Second )
SP T
......
.......................
Set sampling time ( Hour/Minute/Second )
PO
FF......
....................
Auto power OFF management
BEEP.......................
Set beeper sound ON/OFF
DEC.........................
Set SD card Decimal character
SD
F.....
..............
SD memory card Format
dnSt
.....
..............
Air density
Remark :
During execute the " Advanced Setting " function,
if press " HOLD Button " ( 3-3, Fig. 1 ) will exit the
" Advanced Setting " function, the LCD will return
to normal screen.
7-1 Set clock time ( Year/Month/Date,Hour/Minute/ Second )
When the upper display show " dAtE "
1)
Use the "
▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to adjust the value ( Setting start from
Year value ). After the desired value is set, press the
" Enter Button " ( 3-8, Fig. 1 ) once will going to
next value adjustment ( for example, first setting
value is Year then next to adjust Month, Date, Hour,
Minute, Second value ).
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Lutron PAM-9212SD User manual

Category
Measuring, testing & control
Type
User manual

The Lutron PAM-9212SD Pitot Tube Anemometer with SD Card Data Logger is a versatile and accurate instrument designed for measuring air velocity and pressure. With its advanced features and user-friendly interface, it's ideal for various applications in industrial, laboratory, and environmental settings. Key capabilities include:

  • Air Velocity Measurement: Measures air velocity in multiple units (m/s, km/h, FPM, mph, knots) with high accuracy and a wide measurement range (4.1 to 100 m/s).

  • Differential Pressure Measurement: Accurately measures differential pressure up to ±200 mbar with selectable display units (mbar, psi, Kg/cm2, mm Hg, inch Hg, meter H2O, hPa, kPa, inch H2O, and Atmosphere).

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI