Mean Well SE-1500 is a reliable and efficient 1500W single output power supply with a wide range of applications, including industrial automation, medical equipment, and telecommunications systems. It features AC input active surge current limiting, protections against short circuits, overloads, over voltages, and over temperatures, and forced air cooling by a built-in DC ball bearing fan. Additionally, it offers DC OK signal output and built-in remote ON-OFF control and remote sense functions, making it easy to integrate into various systems.

Mean Well SE-1500 is a reliable and efficient 1500W single output power supply with a wide range of applications, including industrial automation, medical equipment, and telecommunications systems. It features AC input active surge current limiting, protections against short circuits, overloads, over voltages, and over temperatures, and forced air cooling by a built-in DC ball bearing fan. Additionally, it offers DC OK signal output and built-in remote ON-OFF control and remote sense functions, making it easy to integrate into various systems.

EMC IMMUNITY
EMC EMISSION
SPECIFICATION
SE-1500-5
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V
300A
0 ~ 300A
1500W
150mVp-p
3.3 ~ 5.5V
±2.0%
±2.0%
±0.5%
150ms, 12ms / 230VAC at full load
26ms / 230VAC at full load
180 ~ 264VAC 254 ~ 370VDC
47 ~ 63Hz
81%
17.5A / 230VAC
60A / 230VAC
<3.5mA / 240VAC
105 ~ 125% rated output power
5.75 ~ 6.75V 14.5 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 35V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL62368-1 BSMI CNS14336-1, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1
,
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ ℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
333.3K hrs min. Telcordia SR-332 (Bellcore) ; 134.5K hrs min. MIL-HDBK-217F (25 )
278*177.8*63.5mm (L*W*H)
3.3Kg; 4pcs/14.2Kg/1.14CUFT
85% 85% 87% 88% 89%
±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0% ±1.0%
150mVp-p
10.8 ~ 13.5V
150mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
150mVp-p
43.2 ~ 56V
12V
125A
0 ~ 125A
1500W
15V
100A
0 ~ 100A
1500W
24V
62.5A
0 ~ 62.5A
1500W
48V
31.3A
0 ~ 31.3A
1502.4W
SE-1500-12 SE-1500-15 SE-1500-24 SE-1500-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.720 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
6. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply
under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system
Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:SE-1500-SPEC 2021-08-27
AC input 180 ~ 264VAC
AC input active surge current limiting
Protections: Short circuit / Overload / Over voltage /
Over temperature
Forced air cooling by built-in DC ball bearing fan
High power density 7.8w/inch
3
With DC OK signal output
Built-in remote ON-OFF control
Built-in remote sense function
UL / CUL approved
Low cost
2 years warranty
Features :
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
PROTECTION
1500W Single Output Power Supply SE-1500 series
DC_OK SIGNAL
REMOTE CONTROL
FUNCTION
PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V
RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off
±0.5%
±0.5%
±1.0%
150mVp-p
25 ~ 30V
27V
55.6A
0 ~ 55.6A
1501.2W
SE-1500-27
R33100
RoHS
CNS14336-1
IEC62368-1TPTC004
UL62368-1
SAFETY &
EMC
(Note 4)
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
BS EN/ BS EN/
EN55024, EN61000-6-2
Standard
Standard
BS EN/
EN55032 (CISPR32)
BS EN/
EN55032 (CISPR32)
BS EN/
EN61000-3-2
BS EN/
EN61000-3-3
BS EN/
EN61000-4-2
BS EN/
EN61000-4-3
BS EN/
EN61000-4-4
BS EN/
EN61000-6-2
BS EN/
EN61000-4-6
BS EN/
EN61000-4-8
BS EN/
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class A
-----
-----
User’s Manual
Mechanical Specification
Terminal Pin No. Assignment :
Pin No.
1
3
I/P EMI
ACTIVE
RECTIFIERS
O.L.P. PWM
REMOTE
CONTROL
CONTROL
FAN LOCK
FAN
PROTECTION
O.T.P.
AUX
POWER
RECTIFIERS
&
FILTER
O.V.P.
+S
-S
+V
-V
DC_OK
RC
DETECTION
CIRCUIT
POWER
SWITCHING
INRUSH
CURRENT
LIMITING
FILTER
2
Assignment
AC/L
FG
AC/N
Case No.982A Unit:mm
Block Diagram
Control Pin (CN3) : JST B6B-XH or equivalent
Pin No.
1
2
3
Pin No.
4
5
6
Assignment
DC_OK Signal
DC_OK GND
-S
Assignment
+S
RC-
RC+
Mating Housing
JST XHP
or equivalent
Terminal
JST SXH-001T
or equivalent
fosc : 65KHz
Derating Curve Static Characteristics
LOAD (%)
INPUT VOLTAGE (VAC) 60Hz
180 190 200 230 264
90
100
80
70
60
50
40
AMBIENT TEMPERATURE ( )
LOAD (%)
20
40
60
80
100
-20010203040506070
(HORIZONTAL)
8-M4(Both Sides) L=8mm
40
63.5
38
12.5
20
4
27
236.3
278
27
236.3
LED
177.8
1013
16max.
ADJ
TB1
+V
-V
OUTPUT
1
6
123
+
7.9
162
direction
Air flow
CN3
4-M4 L=5mm
LN
1500W Single Output Power Supply SE-1500 series
File Name:SE-1500-SPEC 2021-08-27
2-M4
ψ8
.5
+
+
+
Between DC_OK(pin1) and GND(pin2)
3.3 ~ 5.6V
0 ~ 1V
Output Status
ON
OFF
DC_OK Signal is a TTL level signal. "High" when PSU turns on.
1.DC_OK Signal
Function Manual
Function Description of CN3
Pin No. Function Description
4
5
2
3
6
1
+S
RC-
GND
-S
RC+
DC_OK
Return for RC+ signal input.
This pin connects to the negative terminal (-V). Return for DC_OK signal output.
Turns the output on and off by electrical or dry contact between pin 6 ( RC+) and pin 5 (RC-). 0~0.8V: Power ON, 4~10V: Power OFF.
DC_OK signal is a TTL level signal, referenced to pin2(DC_OK GND). "High" when PSU turns on.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect.
Between RC+(pin6) and RC-(pin5)
SW OFF (0 ~ 0.8V)
SW ON (4 ~ 10V)
Output Status
ON
OFF
The PSU can be turned ON/OFF by using the "Remote Control" function.
2. Remote Control
3. Remote Sense
-V
-V
-V
+V
+V
+V
ADJ
ADJ
ADJ
CN3
CN3
CN3
RC+
External Power
Source
Connector for remote control
RC-
SW
I=6~20mA
I=10mA
max.
Sense lines should
be twisted in pairs
+S
(pin4) -S
(pin3)
1500W Single Output Power Supply SE-1500 series
File Name:SE-1500-SPEC 2021-08-27
-
-
-
+
+
+
-S
-S
GND
GND
L
L
L
N
N
N
+S
+S
RC-
RC-
RC+
RC+
DC
OK
DC
OK
DC_OK
LOAD
LOAD
LOAD
GND
-S GND+SRC-RC+ DC
OK
  • Page 1 1
  • Page 2 2
  • Page 3 3

Mean Well SE-1500 Operating instructions

Category
Power adapters & inverters
Type
Operating instructions

Mean Well SE-1500 is a reliable and efficient 1500W single output power supply with a wide range of applications, including industrial automation, medical equipment, and telecommunications systems. It features AC input active surge current limiting, protections against short circuits, overloads, over voltages, and over temperatures, and forced air cooling by a built-in DC ball bearing fan. Additionally, it offers DC OK signal output and built-in remote ON-OFF control and remote sense functions, making it easy to integrate into various systems.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI