Altronix VB6 is a limited power supply designed to power PoE-related products like the eBridge4PCRX receiver and the eBridge4SK transceiver. It provides two sets of 56VDC outputs with up to 30W of total power, making it suitable for powering multiple devices simultaneously. The VB6 features input and output LEDs for easy monitoring, a compact insulated housing for safe installation, and built-in overload protection for added safety. It operates within a wide range of environmental conditions, making it suitable for various indoor applications.

Altronix VB6 is a limited power supply designed to power PoE-related products like the eBridge4PCRX receiver and the eBridge4SK transceiver. It provides two sets of 56VDC outputs with up to 30W of total power, making it suitable for powering multiple devices simultaneously. The VB6 features input and output LEDs for easy monitoring, a compact insulated housing for safe installation, and built-in overload protection for added safety. It operates within a wide range of environmental conditions, making it suitable for various indoor applications.

Overview:
Altronix VB6 is a cost-effective 56VDC/30W UL Listed limited power supply. It is intended to power PoE related
products such as the CAT5 to Coax cable Managed Ethernet Midspan receiver eBridge4PCRX and the transceiver
with integral managed PoE/PoE+ switch eBridge4SK. VB6 provides two sets of output terminals to facilitate
connection for up to two devices. It is powered by a 24VDC/24VAC Class 2 rated transformer/power supply.
Specifications:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes
and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
Unit is intended to be used with a UL Listed Class 2 or LPS (limited power supply). VB6 is not intended to be con-
nected to outside plant leads and should be installed indoors within the protected premises.
1. Mount VB6 in desired location utilizing the mounting hole (Fig. 1a). Use a proper fastener and/or wall
anchor when securing VB6 with screw through its mounting hole to the wall.
2. Connect 24VAC/24VDC to the terminals marked [24VAC/VDC Input] (Fig. 1b). Use 22AWG - 16AWG
wire for this connection. Input power should be a Class 2 rated transformer/power supply (for UL60950-1
applications). Power In LED will illuminate.
3. Measure output voltage and check polarity before connecting devices, in order to avoid potential damage.
4. Connect device(s) to the terminals marked [56VDC/30W], carefully observing polarity (Fig. 1b).
Two devices can be connected simultaneously, with VB6 providing up to 30W of total power.
5. Power Out LED will illuminate indicating normal operation (Fig. 1b).
Technical Specifications:
Parameter Description
Input power requirements 24VAC @ 1.5A or 24VDC @ 1.5A.
Indicators Power Input LED, Power Out LED.
Environmental Conditions
Operating Ambient Temperature: 0ºC to 49ºC (32ºF to 120ºF).
Relative humidity: 85%, +/ – 5%
Storage Temperature: – 20ºC to 70ºC (– 4ºF to 158ºF).
Operating Altitude: – 1,000 to 10,000 ft. (– 304.8 to 3,048m).
Weight (approx.) Product: 0.25 lb. (0.11 kg) | Shipping: 0.3 lb. (0.14 kg)
Agency Listings:
UL/CUL Listed for Information
Technology Equipment
(UL 60950-1).
CUL Listed - CSA Standard C22.2
No.205-M1983, Signal Equipment.
CE European Conformity.
Input:
24VAC @ 1.5A or 24VDC @ 1.5A.
Output:
Two (2) 56VDC outputs with up to 30W
combined total power.
Electronically filtered and regulated outputs.
Built-in overload protection.
Features:
Input and Output LEDs.
Compact insulated housing.
Dimensions (W x L x H approx.):
3.5” x 3.5” x 1” (88.89mm x 88.89mm x 25.4mm).
VB6
Power Supply
Installation Guide
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIVB6 - Rev. 040914 F23U MEMBER
24VAC/
24VDC Input
Two (2) 56VDC outputs
30W total
Power In
LED
Power Out
LED
I.T.E. 43KC
www.altronix.com
VB6
Power Supply
Input: 24VAC/VDC, 1.5A
Output: 56VDC/30W total
24VAC/
24VDC
Input
56VDC
Output
+ ---
56VDC
Output
+ ---
Made in U.S.A.
Power
In
Power
Out
Fig. 1 Fig. 1a
Fig. 1b
  • Page 1 1
  • Page 2 2

Altronix VB6 Installation guide

Type
Installation guide

Altronix VB6 is a limited power supply designed to power PoE-related products like the eBridge4PCRX receiver and the eBridge4SK transceiver. It provides two sets of 56VDC outputs with up to 30W of total power, making it suitable for powering multiple devices simultaneously. The VB6 features input and output LEDs for easy monitoring, a compact insulated housing for safe installation, and built-in overload protection for added safety. It operates within a wide range of environmental conditions, making it suitable for various indoor applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI