Sanyo VA-LANC100 User manual

Type
User manual

Sanyo VA-LANC100 is a Digital Recording Camera LAN Kit that enables users to connect their Sanyo digital recording camera to a computer network, allowing for backup recording, live action monitoring, and remote camera control. With the included hardware adapter and application software, you can update the camera's firmware, establish a network connection, and utilize your computer's extra capabilities for managing and storing recorded footage.

Sanyo VA-LANC100 is a Digital Recording Camera LAN Kit that enables users to connect their Sanyo digital recording camera to a computer network, allowing for backup recording, live action monitoring, and remote camera control. With the included hardware adapter and application software, you can update the camera's firmware, establish a network connection, and utilize your computer's extra capabilities for managing and storing recorded footage.

INSTRUCTION MANUAL
VA-LANC100
Digital Recording Camera LAN Kit
English GB
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
CONTENTS
INTRODUCTION..........................................1
INCLUDED ITEMS .......................................1
LAN KIT SETUP ...........................................2
Setup Instructions....................................... 2
MENU SETUP AFTER FIRMWARE
UPDATE.......................................................5
Flow of Setup Windows............................. 5
HARD DISK CAPACITY SETTINGS
(HDD SET) ................................................... 6
About FAT 32 .............................................. 6
Initializing the Hard Disk ........................... 6
Changing Alarm Capacity .......................... 7
PC CONTROL SETUP
(PC CONTROL SET) ..................................... 8
Set the recording speed............................. 8
Choose the network settings .................... 9
A
Set the IP Address, Subnet Mask and
Gateway ..................................................... 9
B
Set the User ID (up to 5 characters) ...... 10
C
Set the Password
(up to 8 characters) ................................. 11
Changing Set Entries................................ 13
INTRODUCTION
This product is a local area network (LAN)
connection kit for linking a Sanyo digital recording
camera to a computer network. It includes a
hardware adapter and a CD-ROM with both
updating software for the camera and an
application program for the computer.
By updating the camera firmware and establishing
the network, your existing computer will have extra
capabilities for backup recording, displaying a live
action window on your monitor and for remotely
controlling the camera’s recording functions.
Because the system uses the FAT 32 file system
data storage structure, data from the camera’s hard
disk can be read like a removable disk when linked
to the computer with a USB connection. Hard disk
capacity can be up to 137GB.
For instruction on controlling the camera from a
remote computer, see the manual titled Digital
Recording Camera Utility Software 1.6.
INCLUDED ITEMS
1
CompactFlash Ethernet Card
2
Application Software CD-ROM
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
1
English
LAN KIT SETUP
Setup Instructions
Please follow the steps below to use the digital recording camera on a network.
1 USB Driver and Software Installation
Use the included CD-ROM for installing the USB driver and software onto the computer to be connected. For
installation steps, see the manual titled Digital Recording Camera Utility Software 1.6.
2 Firmware Upload
Use the included CD-ROM to replace the firmware (permanent software) in the camera.
1
Insert the CD-ROM into the computer’s CD-ROM drive.
2
Turn on the camera, then connect the USB cable between the computer and the camera.
3
From the Windows Start menu, choose Run.
4
Type in “D:Uploader.exe”.
(“
D
” indicates the computer’s CD-ROM drive. If the drive is different, please enter the correct drive
letter.)
5
Click the OK button.
The “
SANYO Firmware Uploader
” window will appear.
6
Click the Upload button.
The “
Open
” window will appear.
7
Make sure the overwriting software file
SX19X76r.bin is selected, then press the
Open button.
The “
Upload
” window will appear.
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
2
LAN KIT SETUP
8
Click the Yes button.
Overwriting of the firmware will start.
9
After the firmware overwriting action has
been completed, turn off the camera’s
power.
3 PC Control Setup
The four setting adjustments listed below must be made directly on the camera with the camera’s menu
before the camera can be used on a network. These setting adjustments must be made before installing the
LAN adapter. For details, see “
PC CONTROL SETUP (PC CONTROL SET)
”. ( P. 8)
SET THE RECORDING SPEED (RECORDING SPEED SET)
CHOOSE THE NETWORK SETTINGS (NETWORK SET)
4 LAN Kit Installation
The following explains how to install the LAN kit and connect the network.
Use an Ethernet cable for the network cable.
Note:
Make sure the camera power is Off before installing the LAN kit.
1
Use a screwdriver to remove the set screw
A
, then slide the operation panel cover to
the left and remove it.
The removed cover is not used when the LAN
kit is in place.
A
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
3
English
LAN KIT SETUP
2
Insert the LAN card
B
into the camera’s
expansion slot.
Insert the LAN card so that the direction
arrow is on the top side and pointing in.
3
Slip the 2 retaining tabs
C
on the right
side of the LAN kit into place on the
camera body, then insert the adapter’s
cable
D
into the opening in the LAN card
while pulling the adapter down into place
against the side of the camera.
4
Secure the LAN kit into place with the set
screw
E
.
5
Connect the network cable
F
to the LAN
kit.
6
Connect the other end of the network
cable to your Ethernet hub.
B
C
D
1
2
E
F
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
4
MENU SETUP AFTER FIRMWARE
UPDATE
Flow of Setup Windows
The following menu window structure will be established by the firmware update.
Menus Requiring Action after Firmware
Update
Hard Disk Capacity Settings (HDD SET) ( P. 6)
PC Control Setup (PC CONTROL SET) ( P. 8)
Menus Requiring No Action after Firmware
Update
Please consult the digital recording camera’s
instruction manual for steps on setting the
following 4 items.
SETTING THE CLOCK (CLOCK SET)
SYSTEM SETTINGS (SYSTEM SET)
SUMMER TIME SETTINGS (SUMMER
TIME/DAYLIGHT SET)
KEY WORD SETTING (KEYWORD SET)
(MAIN MENU)
RECORD START
PLAYBACK
SETTINGS
CONDITION
MAIN MENU Screen
(SETTINGS)
CLOCK SET
SYSTEM SET
HDD SET
SUMMER TIME/DAYLIGHT SET
KEY WORD SET
PC CONTROL SET
[MENU] (MAIN MENU)
SETTINGS Screen
MENU SET
SET
(HDD SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 45MIN>
<PRE ALARM 0 H 15MIN>
<POST ALARM 0 H 30MIN>
SPACE SET
INITIALIZE
[MENU] (SETTINGS)
(SPACE SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
SETUP YES
(SPACE SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
SETUP YES
DO NOT POWER OFF!
SETTING NOW!
(HDD INITIALIZE)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
INITIALIZE YES
(HDD INITIALIZE)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
DO NOT POWER OFF!
INITIALIZING NOW!
b Hard Disk Capacity Settings
b PC Control Setup
(PC CONTROL SET)
RECORDING SPEED SET
NETWORK SET
[MENU] (SETTINGS)
(RECORDING SPEED SET)
PRE ALARM RATE --- 3 FPS
CAMERA RECORDING FRAMERATE
UNDER PC CONTROL
(NETWORK SET)
IP ADDRESS : 192.168. 0. 10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD :
(IP ADDRESS SET)
IP ADDRESS : 192.168. 0. 10
0123456789
END
(SUBNET MASK SET)
SUBNET MASK: 255.255.255. 0
0123456789
END
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(INITIALIZE)
PASSWORD:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(GATEWAY SET)
GATEWAY : 192.168. 0. 1
0123456789
END
(USER ID SET)
USER ID :ADMIN
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
5
English
HARD DISK CAPACITY SETTINGS (HDD SET)
The first screen for Hard Disk initialization Setting will look like Fig. 1. The following explains how to change
the hard disk capacity or initialize (reformat) the disk.
About FAT 32
The firmware of the LAN connection kit is based on
FAT 32 disk storage architecture. The FAT file
system used by the previous firmware could handle
hard disks with capacity up to 10GB, but FAT 32 file
system can be used on disks up to 137GB. To use
FAT 32, however, the hard disk must be initialized
after the firmware update.
Initializing the Hard Disk
Initializing the hard disk will erase all data for
previously stored images. Be sure to transfer the
stored image data to your computer before
initializing the camera’s hard disk.
As a safeguard for stored image data, a password
is required for initializing the hard disk. For more
information about passwords, see the digital
recording camera’s instruction manual.
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
2
Use the CURSOR (
j
or
l
) button to
select “HDD SET”, then press the SET
button.
The HDD SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “INITIALIZE”, then press the SET
button.
The INITIALIZE screen will appear, allowing
entry of the password.
4
Use the CURSOR button and the SET
button to enter the password from the
alphanumeric pallet.
The PASSWORD field will display asterisks for
entered letters and numbers.
5
Use the CURSOR (
j
or
l
) button to
select “END”, then press the SET button.
????????????????
6
Use the CURSOR (
j
or
l
) button to
select “YES”, then press the SET button.
?????????????????
7
Use the CURSOR button to the set the
capacity in the alarm area.
Example:
1
Set PRE ALARM for 30 minutes.
2
Set POST ALARM for 45 minutes.
Values for “
SUSPICION SHOTS
” and
ALARM TIME
” will be set automatically.
(HDD SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 45MIN>
<PRE ALARM 0 H 15MIN>
<POST ALARM 0 H 30MIN>
SPACE SET
INITIALIZE
[MENU] (SETTINGS)
(Fig. 1)
Alphanumeric
Pallet
(INITIALIZE)
PASSWORD :
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(INITIALIZE)
DO YOU FORMAT THE DISK?
YES
NO
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
6
HARD DISK CAPACITY SETTINGS (HDD SET)
8
Use the CURSOR (
j
or
l
) button to
select “INITIALIZE”, use the CURSOR (
d
or
c
) button to select “YES”, then press the
SET button.
The hard disk will be initialized and the display
will return to the SETTINGS screen.
Selecting “
NO
” will bring up the HDD SET
screen.
Changing Alarm Capacity
The SPACE SET screen will appear when the disk
has been initialized or when POST ALARM images
have not been recorded on the PRE ALARM area of
the hard disk.
Alarm capacity can be changed in the SPACE SET
screen. However, if images have already been
recorded on the POST ALARM area of the hard
disk, the alarm capacity cannot be changed. In this
case, if capacity adjustment is desired, delete the
alarm images or initialize the hard disk, then adjust
the alarm capacity.
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
2
Use the CURSOR (
j
or
l
) button to
select “HDD SET”, then press the SET
button.
The HDD SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “SPACE SET”, then press the SET
button.
The SPACE SET screen will appear.
4
Use the CURSOR button to reset the
capacity values in the alarm area.
Example:
1
Set PRE ALARM for 3 hours, 30 minutes.
2
Set POST ALARM for 2 hours, 45 minutes.
Values for “
SUSPICION SHOTS
” and
ALARM TIME
” will be set automatically.
Note:
If a value is already recorded in the suspicion
area, the alarm capacity set time will be
different.
5
Use the CURSOR (
j
or
l
) button to
select “SET UP”, use the CURSOR (
d
or
c
)
button to select “YES”, then press the SET
button.
The alarm capacity will be changed and the
display will return to the SPACE SET screen.
Selecting “
NO
” will bring up the HDD SET
screen.
(HDD INITIALIZE)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
INITIALIZE YES
(HDD INITIALIZE)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
DO NOT POWER OFF!
INITIALIZING NOW!
(SPACE SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 45MIN>
PRE ALARM 0 H 15 MIN
POST ALARM 0 H 30 MIN
SETUP NO
(HDD SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 0 H 45MIN>
<PRE ALARM 0 H 15MIN>
<POST ALARM 0 H 30MIN>
SPACE SET
INITIALIZE
[MENU] (SETTINGS)
(SPACE SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 4 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
SETUP YES
(SPACE SET)
<SUSPICION SHOTS: 10215PCS>
<ALARM TIME 1 H 15MIN>
PRE ALARM 0 H 30 MIN
POST ALARM 0 H 45 MIN
SETUP YES
DO NOT POWER OFF!
SETTING NOW!
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
7
English
PC CONTROL SETUP (PC CONTROL SET)
The setup steps explained below are necessary for connection of the digital recording camera to a network or
for control of the camera from a computer directly connected with USB.
1
Set the recording speed
2
Choose the network settings
Set the recording speed
Set the recording frame rate that will be used when
the camera is connected to a network or USB. By
lowering the frame rate from the regular setting,
the camera is able to record even when connected
to the computer.
The following frame rates can be set for this
purpose.
Pre Alarm recording rate (PRE ALARM RATE)
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
2
Use the CURSOR (
j
or
l
) button to
select “PC CONTROL SET”, then press the
SET button.
The PC CONTROL SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “RECORDING SPEED SET”, then
press the SET button.
The RECORDING SPEED SET screen will appear.
4
???Use the CURSOR (
j
or
l
) button to
select “PRE ALARM RATE”, then use the
CURSOR (
d
or
c
) button to select “1”.
3FPS:
Records 3 image every second.
1FPS:
Records 1 image every second.
5
After completion of the settings, press the
MENU button.
The PC CONTROL SET screen will reappear.
Keep pressing the MENU button until the
MAIN MENU screen appears.
SET
(RECORDING SPEED SET)
PRE ALARM RATE --- 3 FPS
CAMERA RECORDING FRAMERATE
UNDER PC CONTROL
(PC CONTROL SET)
RECORDING SPEED SET
NETWORK SET
PC CONTROL ----------- ON
RECORD STOP FROM PC -- OFF
[MENU] (SETTINGS)
(RECORDING SPEED SET)
PRE ALARM RATE --- 1 FPS
CAMERA RECORDING FRAMERATE
UNDER PC CONTROL
(RECORDING SPEED SET)
PRE ALARM RATE --- 3 FPS
CAMERA RECORDING FRAMERATE
UNDER PC CONTROL
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
8
PC CONTROL SETUP (PC CONTROL SET)
Choose the network settings
The following settings are necessary to use the
camera on a network.
Note:
Contact your network administrator to obtain
the appropriate IP address.
???????????????? ???????????????
??????????????? ???????????????
A Set the IP Address, Subnet Mask
and Gateway
Example: The initial IP address 192.168.000.010
will be changed to 130.141.110.204.
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
2
Use the CURSOR (
j
or
l
) button to
select “PC CONTROL SET”, then press the
SET button.
The PC CONTROL SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “NETWORK SET”, then press the SET
button.
The NETWORK SET screen will appear.
4
Use the CURSOR (
j
or
l
) button to
select “IP ADDRESS SET”, then press the
SET button.
The IP ADDRESS SET screen will appear.
5
Use the CURSOR button to select “1” from
the numeric pallet, then press the SET
button.
Use the same technique to select the
remaining numbers
30.141.110.204.
” After
12 digits are selected, the cursor will
automatically move to
END
”.
6
Press the SET button.
The display will return to the NETWORK SET
screen.
(NETWORK SET)
IP ADDRESS : 192.168. 0. 10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
(PC CONTROL SET)
RECORDING SPEED SET
NETWORK SET
[MENU] (SETTINGS)
SET
(NETWORK SET)
IP ADDRESS : 192.168. 0.10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
SET
(IP ADDRESS SET)
IP ADDRESS : 192.168. 0. 10
0123456789
END
(IP ADDRESS SET)
IP ADDRESS : 130.141.110. 10
0123456789
END
(IP ADDRESS SET)
IP ADDRESS : 130.141.110.204
0123456789
END
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
9
English
7
Use the same method to set the SUBNET
MASK and GATEWAY numbers.
8
After completion of the settings, press the
MENU button.
The PC CONTROL SET screen will reappear.
Keep pressing the MENU button until the
MAIN MENU screen appears.
B Set the User ID (up to 5 characters)
Example: The initial user ID “ADMIN” will be
changed to “USER1”.
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
2
Use the CURSOR (
j
or
l
) button to
select “PC CONTROL SET”, then press the
SET button.
The PC CONTROL SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “NETWORK SET”, then press the
SET button.
The NETWORK SET screen will appear.
4
Use the CURSOR (
j
or
l
) button to
select “USER ID”, then press the SET
button.
The USER ID SET screen will appear, allowing
entry of the password.
(NETWORK SET)
IP ADDRESS : 130.141.110.204
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
(NETWORK SET)
IP ADDRESS : 192.168. 0. 10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
(PC CONTROL SET)
RECORDING SPEED SET
NETWORK SET
[MENU] (SETTINGS)
SET
(NETWORK SET)
IP ADDRESS : 192.168. 0.10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
10
PC CONTROL SETUP (PC CONTROL SET)
5
Use the CURSOR button to select “U” from
the alphanumeric pallet, then press the
SET button.
Use the same technique to select the
remaining letters “
SER1
”. After 5 letters are
selected, the cursor will automatically move to
END
”.
6
Press the SET button.
The display will return to the NETWORK SET
screen.
7
After completion of the settings, press the
MENU button.
The PC CONTROL SET screen will reappear.
Keep pressing the MENU button until the
MAIN MENU screen appears.
C Set the Password
(up to 8 characters)
Example: The password will be set to
“CAMERA”.
1
Use the CURSOR (
j
or
l
) button to
select “SETTINGS”, then press the SET
button.
The SETTINGS screen will appear.
?????????????????
????????????????????????
2
Use the CURSOR (
j
or
l
) button to
select “PC CONTROL SET”, then press the
SET button.
The PC CONTROL SET screen will appear.
3
Use the CURSOR (
j
or
l
) button to
select “NETWORK SET”, then press the SET
button.
The NETWORK SET screen will appear.
4
Use the CURSOR (
j
or
l
) button to
select “PASSWORD”, then press the SET
button.
In the CHANGE PASSWORD-NETWORK screen,
the “
OLD PASSWORD
” field will be selected.
(USER ID SET)
USER ID :UDMIN
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(USER ID SET)
USER ID :USER1
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
SET
(NETWORK SET)
IP ADDRESS : 192.168. 0. 10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
(PC CONTROL SET)
RECORDING SPEED SET
NETWORK SET
[MENU] (SETTINGS)
SET
(NETWORK SET)
IP ADDRESS : 192.168. 0.10
SUBNET MASK: 255.255.255. 0
GATEWAY : 192.168. 0. 1
USER ID : ADMIN
PASSWORD : ********
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
SET
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
11
English
5
Use the CURSOR button to select “END”,
then press the SET button.
The selected field will move from
END
” to
NEW PASSWORD
”.
Note:
????? ????? ????? ????? ????? ?????
????? ????? ????? ????? ????? ?????
????? ????? ????? ????? ?????
6
Use the CURSOR button to select “C”,
then press the SET button.
An asterisk will be displayed for the entered
character. Use the same technique to select
the remaining letters
AMERA
”.
7
Use the CURSOR button to select “END”,
then press the SET button.
The “******” (CAMERA) password will be
set, and the selected field will move to
VERIFICATION
”.
Verification checks for proper entry of the
desired password.
8
Use the CURSOR button and the SET
button to enter “CAMERA” one more
time, and then select “END” again and
press the SET button.
CAMERA
” will be set as the password and
the NETWORK SET screen will reappear.
9
After completion of the settings, press the
MENU button.
The PC CONTROL SET screen will reappear.
Keep pressing the MENU button until the
MAIN MENU screen appears.
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
SET
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
SET
SET
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
SET
(CHANGE PASSWORD-NETWORK)
OLD PASSWORD:
NEW PASSWORD:
VERIFICATION:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
12
PC CONTROL SETUP (PC CONTROL SET)
Changing Set Entries
The 2 types of entry pallets are shown below.
Numeric Pallet (for addresses)
Alphanumeric Pallet (for User ID and Password)
Example 1: Changing the addresses from
“130141.110.204” to
“131.141.110.204” with the numeric
pallet.
1
Use the CURSOR button to select the
í
or “
ü
” field.
2
Press the SET button as many times as
needed to place the shaded correction
cursor (
ú
) over the “T”.
3
Use the CURSOR button to select “0” from
the numeric pallet, then press the SET
button.
4
Use the CURSOR button to select “END”
from the numeric pallet, then press the
SET button.
(IP ADDRESS SET)
IP ADDRESS :130.141.110.204
0123456789
END
(USER ID SET)
USER ID :USER1
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(IP ADDRESS SET)
IP ADDRESS :130.141.110.204
0123456789
END
(IP ADDRESS SET)
IP ADDRESS :130.141.110.204
0123456789
END
(IP ADDRESS SET)
IP ADDRESS :131.141.110.204
0123456789
END
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
13
English
Example 2: Changing the USER ID from
“UTER1” to “USER1” with the
alphanumeric pallet.
1
Use the CURSOR button to select the
íBS” (backspace) field.
Note: ????? ????? ????? ????? ????? ?????
????? ????? ????? ????? ????? ?????
????? ????? ????? ????? ?????
2
Press the SET button as many times as
needed to place the shaded correction
cursor (ú) over the “T”.
3
Use the CURSOR button to select “S” from
the alphanumeric pallet, then press the
SET button.
4
Use the CURSOR button to select “END”
from the alphanumeric pallet, then press
the SET button.
To enter a space in your USER ID or
PASSWORD, select the blank spot directly
below the letterN”, then press the SET
button.
(USER ID SET)
USER ID :UTER1
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(USER ID SET)
USER ID :UTER1
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
(USER ID SET)
USER ID :USER1
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789
BS END
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
English
14
1AC6P1P2505--
L9EAA/WA (0901KP-BB)
SANYO Electric Co., Ltd.
Printed in Japan
L9EAA/WA (VA-LANC100) GB 2001, 9, 27
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Sanyo VA-LANC100 User manual

Type
User manual

Sanyo VA-LANC100 is a Digital Recording Camera LAN Kit that enables users to connect their Sanyo digital recording camera to a computer network, allowing for backup recording, live action monitoring, and remote camera control. With the included hardware adapter and application software, you can update the camera's firmware, establish a network connection, and utilize your computer's extra capabilities for managing and storing recorded footage.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI