Interlogix 2500 SERIES Installation guide

Type
Installation guide
2500 Series Aluminum Housing Installation
Instructions
Introduction
This is the 2500 Series Aluminum Housing Installation
Instructions for models 2505A-L, 2507A-L, 2507AD, 2507AH.
Installation
To install models 2505A-L, 2507A-L, 2507AD do the following:
1. Mount the switch and magnet so both labels read in the
same direction (Figure 1 below). Use the screws supplied
or 18/8 stainless steel screws.
Note: Switch position and gap distances will be reduced
when switch and magnet are positioned incorrectly.
Figure 1: Line up the labels
UTC Fire &
Security
UTC Fire &
Security
2 in. (5.08 cm)
3 in. (7.62 cm)
0.5 in.
(1.27 cm)
1 in.
(2.54 cm)
Mounting
holes
0.156 in.
(4 mm) dia.
Magnet
included
(part no. 1920)
To install model 2507AH, do the following:
1. Mount switch in desired location.
2. Attach an ohmmeter to the black and white wires. The
meter should read infinity with the magnet away from the
switch.
3. Bring the magnet toward the switch until the meter reads
zero ohms. Mark this position.
4. Bring the magnet closer to the switch until the meter reads
infinity. Mark this position.
5. Position the magnet between the two marks.
6. Align the magnet and switch so the labels read in the
same direction. With the magnet positioned in this
manner, the switch will be harder to defeat with an
external magnet.
Lead functions
Here are the lead colors and functions:
Lead color Function
Black Common
White Closed loop (NO)
Red Open loop (NC)
Specifications
Form A (2505A)
Voltage: 100 V max.
Current: 0.5 A max.
Power: 7.5 W max.
Form C (2507A, 2507AH, 2507AD)
Voltag
e: 30 V max.
Current: 0.25 A max.
Power: 3.0 W max.
Form A (2505A) ULC specifications
Voltage: 30 V max.
Current: 50 mA max.
Form A (2505A) European Union specification
Voltag
e: 48 V max.
Current: 0.5 A max.
P/N 1030557 • REV D • 15APR11 1
Product ordering
Finish is anodized and Lead type is 3 foot stainless steel
armored cable for all models.
Model # Loop
type
Electrical
configuration
Gap distance
(make)
Listing
2505A-L Closed NO Up to 3 in. UL, ULC
2507A-L Open or
closed
SPDT Up to 3 in. UL, ULC
2507AD-L Open or
closed
DPDT Up to 1.5 in. UL
2507AH-L Open or
closed
SPDT 0.75 in. min, 2.5
in. max
UL
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support
Copyright © 2011 UTC Fire & Security. All rights reserved.
2 2500 Series Aluminum Housing Installation Instructions
  • Page 1 1
  • Page 2 2

Interlogix 2500 SERIES Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI