  • Hello! I'm your chat assistant. I've reviewed the FLIR DM92 user manual, and I'm ready to answer your questions about this True RMS Industrial Multimeter. This document provides detailed instructions on how to use the multimeter, including its various measurement modes, like AC/DC voltage and current, resistance, capacitance, and temperature. It also covers features such as VFD mode, peak hold, and manual data recording, and safety precautions for its use.
  • How do I switch the device on?
    How do I enable the manual mode?
    How do I access the setup menu?
USERMANUAL
FLIRMODELDM92
TrueRMSIndustrialMultimeter
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
2
TableofContents
1.DISCLAIMERS4
1.1Copyright4
1.2QualityAssurance4
1.3Documentation4
1.4DisposalofElectronicWaste4
2.SAFETY5
2.1FCCCompliance6
2.2IndustryCanadaCompliance7
3.INTRODUCTION8
3.1KeyFeatures8
4.METERDESCRIPTION9
4.1MeterSections9
4.2FunctionSwitchPositions10
4.3FunctionButtons,SelectorPad,andRotarySwitch10
4.4DisplayDescription11
4.5DisplayIconsandIndicators11
5.OPERATION14
5.1PoweringtheMeter14
5.2Auto/Manualselectmode14
5.3Auto/ManualRangeMode15
5.4VoltageMeasurements15
5.5ResistanceMeasurements15
5.6ContinuityTest16
5.7DiodeTest16
5.8CapacitanceMeasurements16
5.9TypeKTemperatureMeasurements17
5.10CurrentMeasurements17
5.11ExtendedFunctionality18
5.12NormalHoldModeandAutoHoldMode21
5.13LockedMode21
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
3
6.MAINTENANCE22
6.1CleaningandStorage22
6.2BatteryReplacement22
6.3FuseReplacement22
6.4DisposalofElectronicWaste22
7.SPECIFICATIONS23
7.1Generalspecifications23
7.2ElectricalRangeSpecifications24
8.TECHNICALSUPPORT29
9.WARRANTIES29
9.1FLIRGlobalLimitedLifetimeWarranty29
9.2FLIRTestandMeasurementLimited2YearWarranty30
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
4
1. Disclaimers
1.1Copyright
©2014,FLIRSystems,Inc.Allrightsreservedworldwide.Nopartsofthesoftwareincludingsource
codemaybereproduced,transmitted,transcribedortranslatedintoanylanguageorcomputer
languageinanyformorbyanymeans,electronic,magnetic,optical,manualorotherwise,without
thepriorwrittenpermissionofFLIRSystems.
Thedocumentationmustnot,inwholeorpart,becopied,photocopied,reproduced,translatedor
transmittedtoanyelectronicmediumormachinereadableformwithoutpriorconsent,inwriting,
fromFLIRSystems.
Namesandmarksappearingontheproductshereinareeitherregisteredtrademarksor
trademarksofFLIRSystemsand/oritssubsidiaries.Allothertrademarks,tradenamesorcompany
namesreferencedhereinareusedforidentificationonlyandarethepropertyoftheirrespective
owners.
1.2QualityAssurance
TheQualityManagementSystemunderwhichtheseproductsaredevelopedandmanufactured
hasbeencertifiedinaccordancewiththeISO9001standard.
FLIRSystemsiscommittedtoapolicyofcontinuousdevelopment;thereforewereservetheright
tomakechangesandimprovementsonanyoftheproductswithoutpriornotice.
1.3Documentation
Toaccessthelatestmanualsandnotifications,gototheDownloadtabat:http://support.flir.com.
Itonlytakesafewminutestoregisteronline.Inthedownloadareayouwillalsofindthelatest
releasesofmanualsforourotherproducts,aswellasmanualsforourhistoricalandobsolete
products.
1.4DisposalofElectronicWaste
Aswithmostelectronicproducts,thisequipmentmustbedisposedofinan
environmentallyfriendlyway,andinaccordancewithexistingregulationsfor
electronicwaste.
PleasecontactyourFLIRSystemsrepresentativeformoredetails.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
5
2. Safety
SafetyNotes
Beforeoperatingthedevice,youmustread,understand,andfollowallinstructions,dangers,
warnings,cautions,andnotes.
FLIRSystemsreservestherighttodiscontinuemodels,partsoraccessories,andotheritems,orto
changespecificationsatanytimewithoutpriornotice.
Removethebatteriesifthedeviceisnotusedforanextendedperiodoftime.
WarningStatements
Donotoperatethedeviceifyoudonothavethecorrectknowledge.Formalqualificationsand/or
nationallegislationfortheelectricalinspectionscanapply.Incorrectoperationofthedevicecan
causedamage,shock,injuryordeathtopersons.
Donotstartthemeasuringprocedurebeforeyouhavesetthefunctionswitchtothecorrect
position.Thiscancausedamagetotheinstrumentandcancauseinjurytopersons.
Donotchangetoresistancewhenyoumeasurethevoltage.Thiscancausedamagetothe
instrumentandcancauseinjurytopersons.
Donotmeasurethecurrentonacircuitwhenthevoltageincreasestomorethan1000V.Thiscan
causedamagetotheinstrumentandcancauseinjurytopersons.
Youmustdisconnectthetestleadsfromthecircuitthatyoudidatestonbeforeyouchangethe
range.Ifyoudonotdothis,damagetotheinstrumentandinjurytopersonscanoccur.
Donotreplacethebatteriesbeforeyouremovethetestleads.Thiscancausedamagetothe
instrumentandcancauseinjurytopersons.
Donotusethedeviceifthetestleadsand/orthedeviceshowsignsofdamage.Injurytopersons
canoccur.
Becarefulwhenyoudothemeasurementsifthevoltagesaremorethan25VACrmsor35VDC.
Thereisariskofshockfromthesevoltages.Injurytopersonscanoccur.
Donotdodiode,resistanceorcontinuitytestsbeforeyouhaveremovedthepowerfrom
capacitorsandotherdevicesundertestduringameasurement.Injurytopersonscanoccur.
Donotusethedeviceasatooltoidentifyliveterminals.Youmustusethecorrecttools.Injuryto
personscanoccurifyoudonotusethecorrecttools.
Makesurethatchildrencannottouchthedevice.Thedevicecontainsdangerousobjectsandsmall
partsthatchildrencanswallow.Ifachildswallowsanobjectorapart,speakwithaphysician
immediately.Injurytopersonscanoccur.
Donotletchildrenplaywiththebatteriesand/orthepackingmaterial.Thesecanbedangerous
forchildreniftheyusethemastoys.
Donottouchexpiredordamagedbatterieswithoutgloves.Injurytopersonscanoccur.
Donotcauseashortcircuitofthebatteries.Thiscancausedamagetotheinstrumentandcan
causeinjurytopersons.
Donotputthebatteriesintoafire.Injurytopersonscanoccur.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
6
Cautions
Donotusethedeviceforaprocedurethatitisnotmadefor.Thiscancausedamagetothe
protection.
Thissymbol,adjacenttoanothersymbolorterminal,indicatesthattheuser
mustrefertothemanualforfurtherinformation.
Thissymbol,adjacenttoaterminal,indicatesthat,undernormaluse,
hazardousvoltagesmaybepresent.
Doubleinsulation.
ULlistingisnotanindicationoraverificationoftheaccuracyofthemeter
2.1FCCCompliance
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection
againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,
maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment
offandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
1. Reorientorrelocatethereceivingantenna.
2. Increasetheseparationbetweentheequipmentandreceiver.
3. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris
connected.
4. Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
7
CAUTION
ExposuretoRadioFrequencyRadiation.
TocomplywithFCC/ICRFexposurecompliancerequirements,aseparationdistanceofat
least20cmmustbemaintainedbetweentheantennaofthedeviceandallpersons.This
devicemustnotbecolocatedoroperatinginconjunctionwithanyotherantennaor
transmitter.
WARNING
Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance
couldvoidtheuser'sauthoritytooperatetheequipment.
2.2IndustryCanadaCompliance
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo
conditions:
ThisdevicecomplieswithIndustryCanadalicenseexemptRSSstandard(s).Operationissubjectto
thefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemust
acceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.
CAUTION
ExposuretoRadioFrequencyRadiation.
TocomplywithRSS102RFexposurecompliancerequirements,formobileconfigurations,
aseparationdistanceofatleast20cmmustbemaintainedbetweentheantennaofthis
deviceandallpersons.Thisdevicemustnotbecolocatedoroperatinginconjunctionwith
anyotherantennaortransmitter.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
8
3. Introduction
ThankyouforselectingtheFLIRDM92DigitalMultiMeter.
Thisdeviceisshippedfullytestedandcalibratedand,withproperuse,willprovideyearsofreliable
service.
3.1KeyFeatures
4000/40000countsextralargedigitaldualdisplay.
AutoselectionAC/DCinvoltageandcurrentmodes.
Onscreenmenuselectionandnavigatorkeydrive
Variablefrequencydrivemode(lowpassfilter).
0.05%DCVaccuracy.
LowZmeasurement.
Autohold.
Peakholdmeasurement.
dB/dBmmeasurement.
99recordmanualdatarecord/recallmemory.
Indooruseonly;6561’(2000m).
SafetyCategoryRating:CATIV600V,CATIII1000V.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
9
1
24
3
4. MeterDescription
4.1MeterSections
1. CourtesyWorkLights
2. LCDDisplay
3. MODEButton
4. RANGEButton
5. BacklightButton
6. FunctionButtons(detailedbelow)
7. EXITButton
8. HOLD/LockButton
9. WorkLightButton
10. RotaryFunctionSwitch
11. Positive(+)ProbeInputJackforA(Current).
12. Positive(+)ProbeInputJackformA(Current).
13. COM(negative‐)ProbeInputJack
14. Positive(+)ProbeInputJackforV,mV,Ω,and
LoZandTemperature


1. CourtesyWorkLights
2. TestProbeHolders
3. TiltStand
4. BatteryCompartmentCover
Fig41FrontView
Fig42RearView
1
2
6
7
8
3
4
9
5
10
11 14
13
12
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
10
4.2FunctionSwitchPositions
LoZThemetercanmeasurevoltagethroughtheprobeinputs.Alowimpedance
loadisplacedacrosstheinputstostabilizethemeasurement.
OFF ThemeterisswitchedOFFandinfullpowersavingmode.
Themetercanmeasurevoltage(V)throughtheprobeinputs.
Themetercanmeasurelowvoltage(mV)throughtheprobeinputs.
Themetercanmeasureresistance,continuity,ordiodepolaritythroughthe
probeinputs.ThetypeofmeasurementisselectedbytheMODEbutton.
Themetercanmeasurecapacitancethroughtheprobeinputsor
temperaturethroughathermocoupleadapter.Thetypeofmeasurementis
selectedbytheMODEbutton.
Themetercanmeasurecurrentthroughtheprobeinputs.
4.3FunctionButtons,SelectorPad,andRotarySwitch
UsethisbuttontoselectAutoselectorManualselectmode,seesection5.2
Auto/Manualselectmode.
Inmanualselectmode,pressthebuttontochangetheoperatingmode.
UsethisbuttontoselectAutorangeorManualrangemode,seesection5.3
Auto/Manualrangemode.
InManualrangemode,pressthebuttontochangetherange(scale).
PressthebuttontotogglebetweenNormalandHoldmode,seesection
5.12NormalholdmodeandAutoholdmode.
Pressandholdthebuttonfor5secondstoenable/disableLockedmode,
seesection5.13Lockedmode.
Usethisselectorpadtoenableextendedfunctionalitymodesandtonavigate
inmodeoptions.
Pressthisbuttontoexitanextendedfunctionalitymode.
Pressthisbuttontoenable/disablethedisplaybacklight.
Pressthisbuttontoenable/disabletheworklights.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
11
Fig43Displaysnapshot
4.4DisplayDescription
1
2
3
4
5
1. ModeandStatusicons
2. SecondaryDisplay
3. MainDisplay
4. Advancedfunctionicons
5. Bargraph(matchesthereadingonthemaindisplay)
4.5DisplayIconsandIndicators
Indicatesthatthemeterismeasuringstabilizedvoltage.
Indicatesthatthemeasuredvoltageisgreaterthan30V(ACorDC).
IndicatesthattheAutoselectmodeisactive.
Indicatesthatthemeterisdisplayingmaximumreadingvalues.
Indicatesthatthemeterisdisplayingminimumreadingvalues.
Indicatesthatthemeterisdisplayingtheaveragereading.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
12
Indicatesthatthemeterisdisplayingpeakmaximumvalues.
Indicatesthatthemeterisdisplayingpeakminimumvalues.
IndicatesthatthemeterisinAutorangemode.
IndicatesthatthemeterisinHoldmode.
IndicatesthatthemeterisinLockedmode.
Indicatestheactivememorylocation(199).
Indicatesthebatteryvoltagestatus.
Indicatesthattheautopowerofffunctionisenabled.
IndicatesthatthemeterismeasuringACcurrentorvoltage.
IndicatesthatthemeterismeasuringDCcurrentorvoltage.
IndicatesthatthemeterismeasuringAC+DCcurrentorvoltage.
Indicatesthatthecontinuityfunctionisactive.
Indicatesthatthediodetestfunctionisactive.
VFDmodeicon.
Peakmodeicon.
Min/Max/Avgmodeicon.
Frequencymodeicon.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
13
Relativemodeicon.
4000/40000digitselection.
dBmmodeicon.
99pointManualDataRecordingmodeicon.
Setupmodeicon.
Silentmodeicon.
4.5.1ProbeIndicator
Whentheprobeleadsarenotpluggedintothecorrectjacksocketsforthemeasurementselected
bythefunctionswitch,PROBEisdisplayed.
4.5.2Outofrangewarning
Iftheinputisover/underthefullscalerangeinManualrangemode,orifthesignalhasexceeded
themaximum/minimuminputinAutorangemode,OLisdisplayed.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
14
5. Operation
Note:Beforeoperatingthedevice,youmustread,understand,andfollowallinstructions,dangers,
warnings,cautions,andnotes.
Note:Whenthemeterisnotinuse,thefunctionswitchshouldbesettotheOFFposition.
Note:Whenconnectingtheprobeleadstothedeviceundertest,connecttheCOM(negative)lead
beforeconnectingthepositivelead.Whenremovingtheprobeleads,removethepositivelead
beforeremovingtheCOM(negative)lead.
5.1PoweringtheMeter
1.Setthefunctionswitchtoanypositiontoswitchonthemeter.
2.Ifthebatteryindicator showsthatthebatteryvoltageisloworifthemeterdoesnotpower
on,replacethebattery.Seesection6.2BatteryReplacement.
5.1.1AutoPowerOff
Themeterenterssleepmodeafteraprogrammablenumberofminutesofinactivity,see
section5.11.9Setupmode.
Themeterbeepsthreetimes10secondsbeforepoweringoff.Pressanybuttonorturnthe
RotarySwitchtopreventthemeterfrompoweringoff.Theautopowerofftimeoutisthen
reset.
5.2Auto/ManualSelectMode
InAutoselectmode,themeterattemptstoautomaticallyselecttheproperoperatingmodebased
ontheinputsignal:
Ifthefunctionswitchissettothe ,,,or position,themeterattemptstodetermineif
theACorDCmodeshouldbeused.
Autoselectmodeisthedefaultmodeofoperation.Whenanewfunctionisselectedwiththe
functionswitch,thestartingmodeisAutoselectandthe indicatorisdisplayed.
ToenterManualselectmode,pressthebutton.Tomanuallyselecttheoperatingmode,
pressthebuttonrepeatedly.
ToenterAutoselectmode,pressandholdthebuttonuntilthe indicatorisdisplayed.
Note:NotethattheDM92DataRecordingfeaturecannotbeusedwhenthemeterisintheAuto
SelectMode.TousetheDataRecorderpleasesetthemetertotheManualSelectmodefirst.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
15
5.3Auto/ManualRangeMode
InAutorangemode,themeterautomaticallyselectsthemostappropriatemeasurementscale.In
Manualrangemode,thedesiredrange(scale)issetmanually.
Autorangemodeisthedefaultmodeofoperation.Whenanewfunctionisselectedwiththe
functionswitch,thestartingmodeisAutorangeandtheindicatorisdisplayed.
ToenterManualrangemode,pressthe button.Tochangetherange,pressthe button
repeatedlyuntilthedesiredrangeisdisplayed.
ToenterAutorangemode,pressandholdthe buttonuntilthe indicatorisdisplayed.
5.4VoltageMeasurements
1. Setthefunctionswitchtooneofthefollowingpositions:
for high voltage measurements.
forlowvoltagemeasurements.
forvoltagemeasurementsusingthemeter’slowinputimpedancemode.The
indicatorisdisplayed.
2. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintothe
positiveterminal.
3. UsethebuttontoselectAC,DC,orAC+DCvoltagemeasurement.
TheindicatorwillbedisplayedforACmeasurements.
TheindicatorwillbedisplayedforDCmeasurements.
TheindicatorwillbedisplayedforAC+DCmeasurements.
4. Connecttheprobeleadsinparalleltothepartundertest.
5. Readthevoltagevalueonthedisplay.
5.5ResistanceMeasurements
Warning:Donotdodiode,resistanceorcontinuitytestsbeforeyouhaveremovedthepowerfrom
capacitorsandotherdevicesundertestduringameasurement.Injurytopersonscanoccur.
1. Setthefunctionswitchtotheposition.
2. Ensurethatthemeterissettoresistancemeasurement.TheΩunitwillbedisplayed.
Iftheorindictorisdisplayed,pressthe buttonrepeatedlyuntiltheΩunitis
displayed.
3. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintothe
positive terminal.
4. Touchthetipsoftheprobeacrossthecircuitorcomponentundertest.
5. Readtheresistancevalueonthedisplay.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
16
5.6ContinuityTest
Warning:Donotdodiode,resistanceorcontinuitytestsbeforeremovingthepowerfrom
capacitorsandotherdevicesundertestduringameasurement.Injurytopersonscanoccur.
1. Setthefunctionswitchtotheposition.
2. Usethebuttontoselectcontinuitymeasurement.Theindicatorwillbedisplayed.
3. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintothe
positiveterminal.
4. Touchthetipsoftheprobeacrossthecircuitorcomponentundertest.
5. Iftheresistanceis30±5Ω(nominal)orless,themeterbeeps.
Note:ThisthresholdisuserselectableintheSETUPmenuundertheCntin(continuity)setting:
Range:1050Ω;Increment:1;Default:30Ω.
5.7DiodeTest
Warning:Donotdodiode,resistanceorcontinuitytestsbeforeyouhaveremovedthepowerfrom
capacitorsandotherdevicesundertestduringameasurement.Injurytopersonscanoccur.
1. Setthefunctionswitchtothe position.
2. Usethebuttontoselectthediodetestfunction.The indicatorwillbedisplayed.
3. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintothe
positive terminal.
4. Touchthetipsoftheprobeacrossthediodeorsemiconductorjunctionundertest.Makea
noteofthevalueonthedisplay.
5. Reversethepolarityoftheprobes,byinterchangingtheprobetestlocations.
6. Touchthetipsoftheprobeacrossthediodeorsemiconductorjunctionundertest.Makea
noteofthenewvalueonthedisplay
7. Thediodeorsemiconductorjunctioncanbeevaluatedasfollows:
Ifoneofthereadingsdisplaysavalue(typically0.400Vor0.900V)andtheotherreading
displaysOL,thecomponentisgood.
IfbothreadingsdisplayOL,thecomponentisopen.
Ifbothreadingsareverysmallor0,thecomponentisshorted.
5.8CapacitanceMeasurements
Warning:Donotdocapacitancetestsbeforeremovingthepowertothecapacitororotherdevices
undertestduringameasurement.Injurytopersonscanoccur.
1. Setthefunctionswitchtotheposition.
2. Usethebuttontoselectthecapacitancemeasurement.TheF(Farad)unitwillbe
displayed.
3. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintothe
positive terminal.
4. Touchthetipsoftheprobeacrossthepartundertest.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
17
5. Readthecapacitancevalueonthedisplay.
Note:Forverylargecapacitancevalues,itmaytakeseveralminutesforthemeasurementto
settleandthefinalreadingtostabilize.
5.9TypeKTemperatureMeasurements
1. Setthefunctiontothe position.
2. Usethebuttontoselecttemperaturemeasurement.The°For°Cunitwillbedisplayed.
3. Whileobservingthepolarity,insertthethermocoupleadapterintothenegativeCOMterminal
andthepositiveterminal.
4. Touchthetipofthethermocoupletothepartundertest.Keepthethermocoupletiponthe
partuntilthereadingonthedisplaystabilizes.
5. Readthetemperaturevalueonthedisplay.
6. Toavoidelectricalshock,disconnectthethermocoupleadapterbeforeturningthefunction
switchtoanotherposition.
5.10CurrentMeasurements
Currentismeasuredbydisconnectingthepartundertestandconnectingtheprobeleadsinseries
withthepart,seeFigure5.1.
Figure5.1Disconnectedcomponent
1. Setthefunctionswitchtothe position.
2. InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadintooneof
thefollowingpositiveterminals:
Aforhighcurrentmeasurements.
mAforlowcurrentmeasurements.
3. UsethebuttontoselectAC,DC,orAC+DCvoltagemeasurement.
TheindicatorwillbedisplayedforACmeasurements.
TheindicatorwillbedisplayedforDCmeasurements.
TheindicatorwillbedisplayedforAC+DCmeasurements.
4. ConnecttheprobeleadsinserieswiththepartinaccordancewithFigure5.1.
5. Readthecurrentvalueonthedisplay.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
18
5.11ExtendedFunctionality
Inadditiontothebasicmeasurements,themetercanbesettodifferentmodesforextended
functionality.
5.11.1SelectingtheMode
Themodeiconsapplicablefortheselectedmeasurementtypearedisplayedinthelowerpart
ofthedisplay.Whenamodeisenabled,theiconisframed.
Figure5.2Modeicons(ACvoltagemeasurements):PeakmodeandSilentmodeareenabled.
1. Presstheorbuttontonavigatetothedesiredmodeicon.Thecurrentlyselected
iconwillflash.
2. Pressthebuttontoenabletheselected(flashing)mode.
3. Usethe or buttonstostepthroughthemodeoptions.Refertothesection
relatedtothespecificmodefordetailedinstructions.
4. Pressthe buttontodisabletheselected(flashing)mode.
5.11.2VFDMode(ACVandACAonly)
InVFD(variablefrequencydrive)mode,highfrequencynoiseiseliminatedfromthevoltage
measurementthroughtheuseofalowpassfilter.VFDmodeisavailablewhenmeasuringAC
voltageorACcurrent.
1. Select andenableVFDmodeasdescribedinsection5.11.1SelectingtheMode.
5.11.3PeakMode(ACVandACAonly)
InPeakmode,themetercapturesanddisplaysthepositiveandnegativepeakvalues,and
updatesonlywhenahigher/lowervalueisregistered.
1. Select andenablePeakmodeasdescribedsection5.11.1SelectingtheMode.
2. Pressthe or buttontotogglebetweenthedisplayofPeakMaxandPeakMin.
InPeakMaxmode,theindicatorisdisplayed.
InPeakMinmode,theindicatorisdisplayed.
1. Pressthe buttontopausethePeakmode.Pressagaintocontinue.
5.11.4Min/Max/AvgMode
InMin/Max/Avgmode,themetercapturesanddisplaystheminimumormaximumvaluesand
updatesonlywhenahigher/lowervalueisregistered.Themeteralsoaveragesthetotalsum
ofallrecordedvalues.
1. Select andenableMin/Max/Avgmodeasdescribedinsection5.11.1,Selecting
theMode.
2. Presstheor buttontocyclethroughtheminimum,maximum,andaverage
readingdisplays.Thecorrespondingiconsaredisplayed: , ,or 
3. PressthebuttontopausetheMin/Max/Avgmode.Pressagaintocontinue.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
19
5.11.5Frequencymode(ACVandACAonly)
InFrequencymode,thefrequencyisdisplayedinthemaindisplayandtheperiodisdisplayed
inthesecondarydisplay.FrequencymodeisavailablewhenmeasuringACvoltageorcurrent.

1. Select andenableFrequencymodeasdescribedinsection5.11.1Selectingthemode.
5.11.6Relativemode
In Relative mode, the difference between the current reading and a stored reference value is
displayed in the main display. The reference value is displayed in the secondary display.
1. Select andenableRelativemodeasdescribedinsection5.11.1Selectingthemode.
5.11.7dBmMode(ACVonly)
Thedecibel(dB)isalogarithmicunitthatexpressesthemagnitudeofaphysicalquantity
relativetoaspecifiedorimpliedreferencelevel.IndBmmode,themeterdisplaysAC
voltagemeasurementsindBordBmonthesecondarydisplay.
dBanddBmaredefinedasfollows:
dB=20log(VAC/1).
dBm=20log(VAC/0.7746).
1. Select andenabledBmmodeasdescribedinsection5.11.1,Selectingthemode.
2. Pressthetheor buttontotogglebetweenthedisplayofdBanddBm.
5.11.8ManualDataRecordingMode
Themeterhas99memorylocationsforthestorageofmeasurementdata.
1. Select andenableManualDataRecordingmode asdescribedinsection5.11.1
Selectingthemode.
2. Presstheor buttontocyclethroughthemodeoptions:SAVE,LOAD,andCLEAR
shownonthesecondarydisplay.
3. Pressthebuttontoactivatethedisplayedoption:
SAVE:Thedataonthemaindisplayissavedtoamemorylocationshownbythe
indicatorintheupperpartofthedisplay.
LOAD:Thedatastoredinthememorylocationshownbythe indicatoris
displayed.Usetheor buttontochangethememorylocation.Pressthe
buttontoexittheloadfunction.
CLEAR:Thedatainallmemorylocationsiserased.
FLIRDM92USERGUIDEDocumentIdentifier:DM92enUS_AA
20
5.11.9SetupMode
InSetupmode,youcandefinethesettingsforvariousmeteroptions:
Autopoweroff(indicatedbythetextAPO):Amodewherethetimeperiodafter
whichthemeterenterssleepmodecanbeset.Therangeis1to30minutes,or
OFF.Thefactorydefaultis10minutes.
Autobacklightoff(indicatedbythetextb.Lit):Amodewherethetimeperiod
afterwhichthebacklightturnsoffcanbeset.Therangeis1to30minutes,or
OFF.Thefactorydefaultis5minutes.
Continuitythreshold(indicatedbythetextCntin):Amodewherethethreshold
forcontinuitytestscanbeset.
Autohold(indicatedbythetextA.Hold):SelectAutoholdmodeON(Autohold
modeactive)orOFF(Dataholdmodeactive).Formoreinformation,seesection
5.12NormalholdmodeandAutoholdmode.
1. Select andenableSetupmodeasdescribedinsection5.11.1Selectingthemode.
2. Usetheup/downarrowsbuttontocyclethroughthemodeoptionsAPO,b.Lit,Cntin,
A.Hold,andRESETshownonthesecondarydisplay.
3. Pressthebuttontoactivatethedisplayedoption.
APO:Usetheandbuttonstochangetheautopowerofftime.
b.Lit:Usethe andbuttonstochangetheautobacklightofftime.
A.Hold:Usethe andbuttonstoconfigureautohold/datahold.Onindicates
thattheautoholdmodeisactive.Offindicatesthatthedataholdmodeisactive.
Cntin:Usethe andbuttonstochangethecontinuitythreshold.
RESET:Pressthe buttontoresetthesettingstothefactorydefault.
5.11.10SilentMode
InSilentmode,thealertbeeperisdisabled.Silentmodedoesnotaffectthecontinuitybeeper.
Select andenableSilentmodeasdescribedinsection5.11.1Selectingthemode.
/