AllerAir AR 4000 is a dual-purpose air purifier that can be used in both industrial and light applications. It is equipped with a pre-filter, dust filter, HEPA filter, and carbon filter. The pre-filter should be changed daily in an industrial application and as needed in a light application. The dust filter should be changed every 2 to 3 days in an industrial application and as needed in a light application. The HEPA filter should be changed when the gauge reads 2.3" to 2.4". The carbon filter should be changed as required, depending on what and how much product it is adsorbing.

AllerAir AR 4000 is a dual-purpose air purifier that can be used in both industrial and light applications. It is equipped with a pre-filter, dust filter, HEPA filter, and carbon filter. The pre-filter should be changed daily in an industrial application and as needed in a light application. The dust filter should be changed every 2 to 3 days in an industrial application and as needed in a light application. The HEPA filter should be changed when the gauge reads 2.3" to 2.4". The carbon filter should be changed as required, depending on what and how much product it is adsorbing.

The Pre-filter (part #AWFP2424)
The Dust Filter (part #AWFD2424)
The HEPA Filter (part #AWHF0411)
Symptoms
Possible Cause Suggested Solution
Unit will not start
Faulty power supply
Return or supply grill block ed
Blown fuse
Unit not plugged in
Check breaker box
Remove obstruction
Replace fuse
Plug in unit
Insufficient air flow
Obstruction in system
Clogged filters
Remove obstruction
Replace filters
Excessive airflow
Filters not in place
Install filt
ers
AR 2000 and AR 4000
Dual Purpose Air Rhino Units
and
Filter Change Directions
Filter Replacement Directions
Should be changed daily in an industrial application and as needed in a light applicat
i
Unsnap the door latches and open the door.
Remove the used pre-filter and replace with a new pre-filter
-
Close the door and relatch the snaps
See diagram on reverse
Should be changed when the gauge reads: and above 1.7 or when the light comes on depending
on how unit is equiped.
Unsnap the door latches and open the door.
Remove the prefilter, wire-frame filter and carbon filter if supplied.
-
Loosen wing nuts and remove the HEPA filter
Reverse the above procedure to replace the HEPA filter
Dispose of used filters according to local environmental regulations
See diagram on reverse
Should be changed every 2 to 3 days in an industrial application and as needed in a lig
h
application
Unsnap the door latches and open the door.
Remove the used Dust filter and replace with a new pre-f i lte r
See diagram on reverse
Warning: Before opening unit for any reason unplug the unit
For maximum performance it is very important to change filters as
specified in these directions
Trouble Shooting Guide
The Carbon Filter (part #AWCF0500)
Should be changed as required - Life of the carbon depends on what and how much product
it is adsorbing. The only way to know carbon has reached its capacity is when it starts to off gas.
Record the first time it starts to off gas and schedule to change the carbon one or two months
before. You have created your schedule.
Canister Only
Unsnap the door latches and open the door.
Remove the pre-filter and the wire-frame filter
Loosen wing nuts and remove the HEPA filter
Reverse the above procedure to replace the HEPA filter
Dispose of used filters according to local environmental regulations
Note: May be equiped with AWCF0314 carbon filter.
Close the door and relatch the snaps
1) Open the door and pull out
the pre-filters
Dust filter
A WFD2424
W hite Pr e-filter
AWFP2424
2) Untight the 4 wing-nuts
3) Pull out the HEPA or Carbon filter
as supplied
4) Close the door
AllerAir_MK : Manua ls : Q uickStartAR2000D ualpurpose .pdf J a n 09, 2006
HEP A or
Carbon
HEPA (AWFH0411) or
Carbon Filter(AWCF0500) -100 lbs
as supplied
C arbon filter
with H E PA only
AWCF0314
If your unit is equiped with a pressure
gauge and a HEPA Filter, please follow
these instructions:
On the AirRhino 2000,The HEPA filter shoud
be changed when the gauge readsand above
1.7 inches W.C.
On the AirRhino 4000, with a new HEPA and
clean prefilters the gauge reads 1.6" W.C.
The HEPA shoud be changed when the gauge
reads 2.3" to 2.4".
Speed Control or S witch
Pressure
Gauge
or lig ht
Panel Mount
Control
Side View
Filter change diagram
AR 2000 and AR 4000
Dual Purpose Air Rhino Units
Toll free 1-888-852-8247
E -mail: info@ allerair.com
www.allerair.com
LINE 1
GROUND
LINE 2
FUSE 15A
MOTOR
GND
SPEED
CONTROL
WHT
BLK
GRN
BLK
ORN
GRN
OR SWITCH
LIGHT
PS
(ONLY IN UNITS NOT EQUIPPED WITH GAUGE)
Electrical diagram
VOLTS 115 , AMPS 6.8
350W, RPM 1725
PH 1
THERMALLY PROTECTED
THERMALLY PROTECTED
VOLTS 115 , AMPS 3.3/2.8
PH 1
200W, RPM 1610/800
THERMALLY PROTECTED
VOLTS 115 , AMPS 15
PH 1
650W, RPM 1080
OR
OR
VOLTS 230 , AMPS 2.5
PH 1
RPM 900
OR
  • Page 1 1
  • Page 2 2

AllerAir AR 4000 User manual

Type
User manual
This manual is also suitable for

AllerAir AR 4000 is a dual-purpose air purifier that can be used in both industrial and light applications. It is equipped with a pre-filter, dust filter, HEPA filter, and carbon filter. The pre-filter should be changed daily in an industrial application and as needed in a light application. The dust filter should be changed every 2 to 3 days in an industrial application and as needed in a light application. The HEPA filter should be changed when the gauge reads 2.3" to 2.4". The carbon filter should be changed as required, depending on what and how much product it is adsorbing.