Extech Instruments VFM200 is an accurate and reliable device used to measure the concentration of formaldehyde (HCHO) and total volatile organic compounds (TVOC) in the air. It features a fuel cell formaldehyde sensor technology and provides real-time readings of both HCHO and TVOC concentrations. The VFM200 has a backlit LCD display, selectable units of measurement (PPM or mg/m³), and audio-visual high and low alarms for HCHO. It also has an auto power-off function to conserve battery life.

Extech Instruments VFM200 is an accurate and reliable device used to measure the concentration of formaldehyde (HCHO) and total volatile organic compounds (TVOC) in the air. It features a fuel cell formaldehyde sensor technology and provides real-time readings of both HCHO and TVOC concentrations. The VFM200 has a backlit LCD display, selectable units of measurement (PPM or mg/m³), and audio-visual high and low alarms for HCHO. It also has an auto power-off function to conserve battery life.

UserManual
Formaldehyde(HCHOorCH
2
0)andTotal
VolatileOrganicCompounds(TVOC)Tester
ModelVFM200
AdditionalUserManualTranslationsavailableatwww.extech.com
2VFM200enGB_V1.212/16
1
6
5
7
2
3
4
8
Introduction
ThankyouforselectingtheExtechInstrumentsModelVFM200.The VFM200 measuresHCHO
(formaldehyde)andTVOC(TotalVolatileOrganicCompounds).
PotentialsourcesforTVOCsincludepaints,finishes,adhesives,cigarettesmoke,pesticides,
personalcareproducts,carexhaust,newfurnishings,wallcoverings,householdcleansers,and
cookingfuels.Chemicalsinclude:Acetone,EthyleneGlycol,Formaldehyde,
Xylene,1,3butadiene,
Tetrachloroethene,HydrogenSulfide,Ammonia,Toluene,Benzene,MethyleneChloride,
Perchloroethylene,andMTBE.
Thisdeviceisshippedfullytestedandcalibratedand,withproperuse,willprovideyearsofreliable
service.Pleasevisitourwebsite(www.extech.com)tocheckforthelatestversionofthisUser
Guide,ProductUpdates,and
CustomerSupport.
Features
FuelCellFormaldehydeSensorTechnology
Highaccuracymeasurements
BacklitLCDdisplay
RealtimedisplayofHCHO(formaldehyde)concentrationinair
Real‐timedisplayofTVOC(TotalVolatileOrganicCompounds)concentrationinair
Twounitselections(PPM,mg/m³)
AudiovisualHighandLowAlarmsfor
HCHO
Autopoweroff
Description
METERDESCRIPTION
1. HCHOsensor(front)
2. ACAdaptorjack(underflap)
3. DownarrowandAlarmSetupbutton
4. Batterycompartment(rear)
5. ONOFFbutton(alsousedinAlarmSetup)
6. UparrowandUNITselectionbutton
7. BacklitDisplay
8. TVOCsensor(rear)
3VFM200enGB_V1.212/16
mg/m
mg/m
3
3
1
2
3
4
5
6
7
LCDDISPLAY
1. HCHOreading
2. TVOCreading
3. Selectableunitsofmeasure
4. AlarmBeepersymbol
5. AutoPowerOFFreminder
6. RechargeableBatterystatus
7. HighandLowAlarmsymbols
Operation
POWERTHEMETER
Pressthe buttontoturnonthemeter.Thebatterysymbolinformstheuserastothebattery
strength. Connect the battery charger to recharge the battery. Long press the
button to
poweroff.TheLCDwillcountdown:3,2,1,thenOFFbeforeswitchingoff.
AUTOPOWEROFF
Themeterwillswitchoffafter30minutesofinactivity.Pressanyfunctionbuttontopreventthe
meter from powering off; the auto power off timer will be then be reset. The APO display
symbolremindstheuserthatAutoPowerOFFisalwaysactive.
GERNERALUSE
All LCD display lineswill switch ON whenpoweris applied tothe meter. The bottom TVOC
display will count down from 10 seconds or from 90 seconds (depending on the
environment)tozero.Whencountdowniscompletethemeterisreadyforuse.
In normal mode, the top
display indicates the HCHO concentration in PPM or mg/m³. The
bottomdisplayindicatestheTVOCconcentrationinPPMormg/m³.
UsetheUNITbuttontoswitchunitsbetweenPPMandmg/m³.
With the meter on, if the measured HCHO concentration exceeds the high or low user
programmable Alarm
thresholds, the LED display will flash red in color and the audible
beeper will sound (unless it has been disabled with the SET/ button). Press SET/ to
silence the alarm beeper (when it is sounding) or to disable the beeper entirely. When
disabled,thedisplayedbeepersymbolisswitchedoff.
ALARMSETUP(HCHOonly)
LowAlarmSetup
1. LongpresstheSET/ buttontoenterthesetupmode.
2. ThelowalarmiconwilldisplayandtheLCDwillshowthelowalarmthreshold.
3. Usetheand buttonstoadjustthelowalarmthreshold.
4. Pressthe
buttontogotothehighalarmsetupscreen.
HighAlarmSetup
1. Usetheand buttonstoadjustthehighalarmthreshold.
2. Pressthe
buttontoreturntothenormalmeasurementmode.
4VFM200enGB_V1.212/16
CONTROLBUTTONS
1. ShortpresstheSET buttontosilencethebeeper(whenitissounding)orto
disable/enablethealarmbeeper.Thisbuttonisalsousedasadownarrowtochangethe
highandlowAlarmthresholdvaluesintheAlarmSetupmode.
2. LongpresstheSETbuttonto
entertheAlarmSetupMode(SeeAlarmSetupsection).
3. ShortpresstheUNITbuttontochangetheunitofmeasure(PPMormg/m³)ortouseit
asanuparrowtosetthealarmthresholdvaluesintheAlarmSetupmode.
SAFETY
Donotstoreorusetheinstrumentinanenvironmentwherecorrosivegasispresent.
Donotobstructthesensorswheninuse.
Useonlythesuppliedlithiumionbatterytopowerthe meter.
UseonlythesuppliedACadapter/batterychargertochargethelithiumionbattery.
BATTERYCHARGEandREPLACEMENT
1. Whenthebatteryrequirescharging,plugthesuppliedbatterychargerintothemeter(left
side,underflap)andtoasourceofACpower.Afullchargerequires2hours.
2. Toreplacethebattery,opentherearbatterycompartmentandreplacethePolymer
lithiumionbattery(7.4V1300mAh).Reassemblethemeterbeforeuse(part#VPCBATT)
BatterySafetyNotes:Pleasedisposeofbatteriesresponsibly;neverdisposeofbatteriesinafire,
batteries may explode orleak. Ifthe meteris not tobe usedfor 60days ormore, removethe
batteryandstoreseparately.
Neverdisposeofusedbatteriesorrechargeablebatteriesinhouseholdwaste.
Asconsumers,use rs arelegallyrequiredto takeusedbatteriestoappropriatecollection
sites,theretailstorewherethebatterieswerepurchased,orwhereverbatteriesaresold.
Disposal: Do not disposeofthisinstrumentinhousehold waste. Theuseris
obligated to take endof
lifedevicestoadesignatedcollectionpointforthedisposalofelectricalandelectronicequipment.
CLEANINGANDSTORAGE
Periodicallywipethecasewithadampclothandmilddetergent;donotuseabrasivesorsolve
nts.Pleaseremovethebatteryifthemeterisstoredforalongperiodoftime.
5VFM200enGB_V1.212/16
Specifications
Sensor ProfessionalFuelCelltechnology
HCHORange 0.00to5.00mg/m³(orPPM)
HCHOResolution 0.01mg/m3(orPPM)
HCHOBasicAccuracy ±5%FS
TVOCRange 0.00to9.99mg/m³(orPPM)
TVOCResolution 0.01mg/m³(orPPM)
TVOCBasicAccuracy ±5%FS
ResponseTime≤2seconds
OperatingTemperature 0°Cto40°C(32to104°F)
StorageTemperature‐10°Cto60°C(14to140°F)
PowerSupply RechargeablePolymerlithiumionbattery(7.4V1300mAh)
BatteryChargeTime Approx.3hourswithACadapter
Battery 7.4V1300mAh(part#VPCBATT)
Dimensions 165x60x25mm(6.5x2.4x1.0in.)
Weight 584g(20.6oz.)
Copyright©2016FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
ISO9001Certified
www.extech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Extech Instruments VFM200 User manual

Category
Measuring, testing & control
Type
User manual

Extech Instruments VFM200 is an accurate and reliable device used to measure the concentration of formaldehyde (HCHO) and total volatile organic compounds (TVOC) in the air. It features a fuel cell formaldehyde sensor technology and provides real-time readings of both HCHO and TVOC concentrations. The VFM200 has a backlit LCD display, selectable units of measurement (PPM or mg/m³), and audio-visual high and low alarms for HCHO. It also has an auto power-off function to conserve battery life.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI