Type
Rated Torque(N.m)
DT82TV/F
1.2N.m
Parameter (More models and parameters are subject to the nameplate)
Rated Voltage(V) AC 100V-240V
Emission Frequency(MHz) 433.925MHz
Z-Wave Frequency(MHz) 868.4MHz EU;908.4MHz US
Open/close Speed(cm/s)14cm/s
Functional features
Hand-pull function
Resistance and stop function
Electronic memory limit function
Manual setting for limit boundaries function
Weak electric switch selection function
Strong electric switch selection function
Serial interface communication control
The third limit position setting function
Z-Wave setting
-10
85
Working
Temperature
Setting
button
Weak electric
switch interface
Serial interface
LED light
Public line
Motor reverse line
Motor forward line
Motor RXD line
GND
3.3V
Motor TXD line
Z-Wave setting button
Z-Wave light
5
The installation method of curtain motor
Assemble the curtain motor
track at appropriate place,
then fix with screws
Check the position of brackets,
fix it at an appropiate place on
the track
Finish assembling
5
Please check assembling is ok
4
Assemble the motor
3
AC 100V~240V
Blue =Neutral line
Brown = Live wire & Switch public line
Yellow and Green=Earth line
White/Gray = Switch Up line
Black = Switch Down line
Strong electric Switch installation of curtain motor
4
Strong electric Switch mode 1 & mode 3: Strong electric Switch Hotel mode:
Black L2
White/Gray L1
Blue (Neutral line)
Brown (Live line)
Hotel card system
Yellow and Green (Earth line)
Note: Specific operation see back <Strong electric switch mode selection> action bar.
Note: The Neutral line and the Live
line can not reverse,the wiring after,
if spare Wire exposed,please press
with a Pressure line cap,and do
insulation work.
Positive Back
12cm
DT82TV/F The length of profiled material: 200cm--14cm=186cm
S
track
Insert the track
joint board into
the two ends of track
The following steps pls refer to
“the assembly of rubber belt and track”
Track joint board
Insert the track joint bracket
for one end to the track joint
Fix the screws
Track joint
bracket
The joint assembly of track
Use the screw driver to
place the parts like the
gear into the lower cover
Refer the complete lower
cove in below picture
Thread the rubber belt
into thethe lower cover
Keep this end complete
Fix the cut rubber belt end
with the belt fasten button
Leave half teeth
Install the clip part like the referance picture
and insert the track into the lower cover
Slide the slip part to the other end to be flush with the
head rail.Cut the other end of rubber belt with 12cm left
Leave one teeth
between these two
belt fasten button
Install the belt fasten button and
the slip part as in the picture
The marked position is in the
middle of the slip parts.Half of
the slip parts are in the head
rail as in the picture
Seperate the lower cover and the headrail with the
12cm belt remaining outside the headrail.Then fix
two fasten buttons on the same side of rubber belt
(it is to figure out the position of the other slip part.)
DT82TV/F
The assembly of rubber belt for curtain motor
The comfirmation
of profiled material
dimension
The length of profiled material = The total
lenth of track - The cap length × 2
The total length of track is 2m
7cm
The cap length
Install the belt facton button
and the slip part as in the picture
After one slip part installed,then thread the other
end of the belt through the other lower cover
These two slip parts is successfully installed Slide the runners into the track
The runner are installed Place the hook and the upper cover into the track
The hook
5
4
3
5
3
The slip
parts
4
Folding method for joint track (for easy transit)
Track folding method
The overlap arm
which is connected
to the two ends of
rubber belt
Search for the sl-
ip part connected
with the ends of
the rubber belt
Take off the screw
of the slip parts
and the connection
bracket
Pull the slip parts
slightly and seper-
ate the connection
part at the same
time
Push the connec-
tion parts to one
side
Fold the track
Unfold the
folded track
Combine the
track slowly
Push the con-
nection bracket
to the connec-
tion part
Restoring the track
Screw the co-
nnnection bra-
cket and install
the slip parts
The track is
successfully
assembled
Note: The track needs to be engrafted when
the length is less the required
The track needs to be engrafted when
inconvenient to transport
4
2
1
Yellow and Green=Earth line
Brown=Live line
Blue=Neutral line
Black=Down line
3White/Gray=Up line
Yellow and Green E=Earth line
Brown=Live line
Blue N=Neutral line
Black L2=NC
White/Gray L1=Hotel Mode
4
2
1
3
Pressure line cap
1. Operating
The valid interval of the emitter button is 10s,the emitter will quit the set after 10s;
The LED flashes for hint,please do the next step after the hint.
2. Set limit position
Every time you install the motor,first set after a curtain opened travel to work properly;
After setting,with power off and memory function,after each power cycle required to open or close a recovery limit;
After replacing the track or cord to be removed for the limit,and then set limit.
3. When the motor running without any operation,the maximum running time is 4 minutes,it will stop automatically.
4. If the emitter lost,please set up again with new emitter.
5. Z-Wave setting:
Associations:
This product support 2 association groups; each group supports max 5 associated nodes.GROUP 1 is lifeline service
that assigned to curtain motor position. It enables the curtain motor to send reports to Z-Wave Controller or Z-Wave
Gateway whenever the motor is starting or stopped.
The Group Support:
SWITCH_MULTILEVEL_REPORT_V3
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows for Send Multilevel Report to associated devices in this group.This Group Support:
SWITCH_MULTILEVEL_REPORT_V3
Support Command Class
Basic Mapping:
Basic Set = 255 maps to Multilevel Switch = 255
Basic Set = 0 maps to Multilevel Switch = 0
Basic Set = 1-99 maps to Multilevel Switch = 1-99
Basic Get/Report maps to Multilevel Switch Get/Report
Advanced configuration
1.Set the direction:This parameter can be used to set the motor rotation direction,the motor direction is forward
(Configuration Value set to 0) or the opposite direction(Configuration Value set to 1),The default value is 0.
Command Parameter Number Size Configuration Value Default
CONFIGURATION_SET 1 1 01 0
2.Set to start holding hands:This parameter can be used to set the motor open hand start function(Configuration
Value set to 0) or closd(Configuration Value set to 1),The default value is 0.
Command Parameter Number Size Configuration Value Default
CONFIGURATION_SET 2 1 01 0
3.Configure weak electric switch mode:This parameter can be used to set the need of weak electric switch mode.
Provide 4 kinds of weak electric switch mode is optional,respectively:Double-button reboundable switch(Configuration
Value set to 1),Double-button not reboundable switch(Configuration Value set to 2),DC246 switch(Configuration Value
set to 3),Single-button cyclic switch mode(Configuration Value set to 4),The default value is 1.
Command Parameter Number Size Configuration Value Default
CONFIGURATION_SET 3 1 14 1
4.Configure strong electric switch mode:This parameter can be used to set the need of strong electric switch mode.
Provide 3 kinds of weak electric switch mode is optional,respectively:Double-button not reboundable(Configuration
Value set to 0) ,Hotel mode(Configuration Value set to 1),Double-button reboundable mode(Configuration Value
set to 2),The default value is 0.
Command Parameter Number Size Configuration Value Default
CONFIGURATION_SET 4 1 02 0
5.Read whether the total limit is set:This parameter can be used to read the motor's total limit is already set.Not set the
limit(Read into the Configuration Value is 0);Already set the limit(Read into the Configuration Value is 1)
Command Parameter Number
CONFIGURATION_GET 5
6.Read the device type:This parameter can be used to read the type of the motor.Motor types are divided into curtain
motor(Read into the Configuration Value is 0x01),shutter(Read into the Configuration Value is 0x11),Venetian blinds
(Read into the Configuration Value is 0x12)
Command Parameter Number
CONFIGURATION_GET 6
7.Read the motor power supply type:This parameter can be used to read the motor power supply type.The power of
motor is classified into:Mains power supply(Read into the Configuration Value is 0),battery power(Read into the
Configuration Value is 1).
Command Parameter Number
CONFIGURATION_GET 7
8.Manually set / cancel open borders:Manually set the open boundary of the curtain(Configuration Value set to 1),
cancel manually open the border of the curtain(Configuration Value set to 0).
Command Parameter Number Size Configuration Value
CONFIGURATION_SET 8 1 01
9.Manually set / cancel close borders:Manually set the close boundary of the curtain(Configuration Value set to 1),
cancel manually close the border of the curtain(Configuration Value set to 0).
Command Parameter Number Size Configuration Value
CONFIGURATION_SET 9 1 01
10.Delete the limit:This command can delete the limit that has been set for the motor.
Command Parameter Number Size Configuration Value
CONFIGURATION_SET A 1 7F
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to
communicate to other security enabled Z-Wave Plus products
This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all
implemented functions.
This product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the network. &
DT82TV/F is a security enabled Z-Wave Plus Product. It supports security standard S2 and the
security standard S0.
Command class Version Secure
COMMAND_CLASS_BASIC V1
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_VERSION V2 Yes
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_SWITCH_MULTILEVEL V3
COMMAND_CLASS_SWITCH_BINARY V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1
COMMAND_CLASS_ASSOCIATION V2 Yes
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 Yes
COMMAND_CLASS_CONFIGURATION V1
COMMAND_CLASS_POWERLEVEL V1 Yes
COMMAND_CLASS_TRANSPORT_SERVICE V2
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_SECURITY_2 V1
COMMAND_CLASS_SUPERVISION V1 Yes
COMMAND_CLASS_FIRMWARE_UPDATE_MD V4
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.