Vacon NX Series User guide

Type
User guide

This manual is also suitable for

vacon nx
ac drives
marine application (apfiff09)
application manual
®
2 • Vacon apfiff09 marine
Tel. +358 205
VACON MARINE APPLICATION MANUAL
INDEX
Document code: ud01059
Software code: APFIFF09V165
Date: 25.2.2016
1. MARINE APPLICATION - INTRODUCTION ............................................................................................................... 6
1.1 General ......................................................................................................................................................... 6
1.2 Basic Features ............................................................................................................................................... 7
2. Marine Versions compatibility issues .................................................................................................................... 8
3. Control I/O ............................................................................................................................................................ 9
4. “Terminal To Function” (TTF) programming principle .......................................................................................... 10
4.1 Defining an input/output for a certain function on keypad ........................................................................... 10
4.2 Defining a terminal for a certain function with NCDrive programming tool ................................................... 11
4.3 Defining unused inputs/outputs................................................................................................................... 12
5. MARINE APPLICATION MONITORING VALUES .................................................................................................. 13
5.1 Monitoring values........................................................................................................................................ 14
5.1.1 Monitoring values 2................................................................................................................................. 15
5.1.2 FieldBus Monitoring values ...................................................................................................................... 16
5.1.3 Master/Follwer Monitoring values .......................................................................................................... 16
5.1.4 PI Control Monitoring values ................................................................................................................... 16
5.1.5 Frequency Chain ...................................................................................................................................... 17
5.1.6 Torque Chain ........................................................................................................................................... 17
5.1.7 Active Limits ............................................................................................................................................ 17
5.2 Monitoring values description ..................................................................................................................... 18
5.2.1 Monitoring values 2................................................................................................................................. 21
5.2.2 FieldBus Monitoring values ...................................................................................................................... 25
5.2.3 Master / Follower .................................................................................................................................... 31
5.2.4 PI Control monitoring .............................................................................................................................. 34
5.2.5 Frequency Chain ...................................................................................................................................... 35
5.2.6 Torque Chain ........................................................................................................................................... 35
5.2.7 Counters ................................................................................................................................................. 36
6. MARINE APPLICATION PARAMETER LIST .......................................................................................................... 38
6.1 Basic parameters ......................................................................................................................................... 38
6.2 Reference Handling ..................................................................................................................................... 39
6.2.1 Basic Settings .......................................................................................................................................... 39
6.2.2 Constant Reference ................................................................................................................................. 39
6.2.3 Power Reference ..................................................................................................................................... 40
6.2.4 Torque Reference .................................................................................................................................... 40
6.2.5 Prohibit frequency parameters ................................................................................................................ 41
6.2.6 Motor Potentiometer .............................................................................................................................. 41
6.2.7 Adjust Reference ..................................................................................................................................... 41
6.3 Ramp Control .............................................................................................................................................. 42
6.3.1 Basic Settings .......................................................................................................................................... 42
6.3.2 Quick Stop ............................................................................................................................................... 42
6.3.3 Ramp Control Options ............................................................................................................................. 42
6.4 Input Signals ................................................................................................................................................ 43
6.4.1 Basic Settings .......................................................................................................................................... 43
apfiff09 marine vacon • 3
24-hour
6.4.2 Digital inputs ........................................................................................................................................... 43
6.4.3 Analogue input 1 ..................................................................................................................................... 44
6.4.4 Analogue input 2 ..................................................................................................................................... 45
6.4.5 Analogue input 3 ..................................................................................................................................... 45
6.4.6 Analogue input 4 ..................................................................................................................................... 46
6.4.7 Options ................................................................................................................................................... 46
6.5 Output Signals ............................................................................................................................................. 47
6.5.1 Digital output signals ............................................................................................................................... 47
6.5.2 Analogue output 1 ................................................................................................................................... 48
6.5.3 Analogue output 2 ................................................................................................................................... 49
6.5.4 Analogue output 3 ................................................................................................................................... 49
6.5.5 Analogue output 4 ................................................................................................................................... 49
6.5.6 Delayed digital output 1 .......................................................................................................................... 50
6.5.7 Delayed digital output 2 .......................................................................................................................... 50
6.5.8 Supervision Limits ................................................................................................................................... 51
6.6 Limit Settings ............................................................................................................................................... 52
6.6.1 Current handling ..................................................................................................................................... 52
6.6.2 Power Handling ....................................................................................................................................... 52
6.6.3 Torque Handling ...................................................................................................................................... 53
6.6.4 Frequency Handling ................................................................................................................................. 53
6.6.5 DC-Link Handling ..................................................................................................................................... 54
6.6.6 Limit Settings Options.............................................................................................................................. 54
6.7 Flux and DC Current handling....................................................................................................................... 55
6.7.1 Flux and DC Current handling OL Settings ................................................................................................ 55
6.7.2 Flux and DC Current handling CL Settings ................................................................................................. 55
6.8 Motor Control ............................................................................................................................................. 56
6.8.1 Motor Control Basic Settings ................................................................................................................... 56
6.8.2 U/f Settings ............................................................................................................................................. 56
6.8.3 Closed Loop Control Settings ................................................................................................................... 56
6.8.4 PMSM Control settings ............................................................................................................................ 57
6.8.5 Stabilators ............................................................................................................................................... 57
6.8.6 Tuning parameters .................................................................................................................................. 58
6.8.7 Identification parameters ........................................................................................................................ 59
6.9 Speed Control .............................................................................................................................................. 60
6.9.1 Speed Control Basic settings .................................................................................................................... 60
6.9.2 Speed Control OL Settings ....................................................................................................................... 60
6.9.3 Speed Control CL Settings ........................................................................................................................ 60
6.10 Drive Control ............................................................................................................................................... 61
6.11 Master Follower Control Parameters ........................................................................................................... 62
6.12 Protections .................................................................................................................................................. 63
6.12.1 Common settings ................................................................................................................................ 63
6.12.2 Temperature sensor protections ......................................................................................................... 64
6.12.3 Stall Protection.................................................................................................................................... 64
6.12.4 Speed error monitoring ....................................................................................................................... 65
6.12.5 Motor thermal protections .................................................................................................................. 65
6.12.6 Living Zero monitoring ........................................................................................................................ 65
6.12.7 Underload protection .......................................................................................................................... 66
6.12.8 Earth Fault protection ......................................................................................................................... 66
6.12.9 Cooling protection............................................................................................................................... 66
6.12.10 Fieldbus protection ............................................................................................................................. 66
6.12.11 External Fault ...................................................................................................................................... 67
6.12.12 Encoder Fault ...................................................................................................................................... 67
6.13 Fieldbus parameters .................................................................................................................................... 68
6.14 ID Control Functions .................................................................................................................................... 69
6.14.1 Value Control ...................................................................................................................................... 69
6.14.2 DIN ID Control 1 .................................................................................................................................. 69
6.14.3 DIN ID Control 2 .................................................................................................................................. 69
4 • Vacon apfiff09 marine
Tel. +358 205
6.14.4 DIN ID Control 3 .................................................................................................................................. 69
6.14.5 ID Controlled Digital Output 1............................................................................................................. 70
6.14.6 ID Controlled Digital Output 2 ............................................................................................................. 70
6.14.7 Free DIN Delay .................................................................................................................................... 70
6.15 Brake Control .............................................................................................................................................. 71
6.16 Autorestart parameters ............................................................................................................................... 72
6.17 PI Control Parameters .................................................................................................................................. 72
6.18 Keypad control (Control keypad: Menu M3) ................................................................................................. 73
6.19 System menu (Control keypad: Menu M6) ................................................................................................... 73
6.20 Expander boards (Control keypad: Menu M7) .............................................................................................. 73
7. MARINE APPLICATION DESCRIPTION OF PARAMETERS .................................................................................... 74
7.1 Basic Parameters ......................................................................................................................................... 74
7.2 Reference Handling ..................................................................................................................................... 79
7.2.1 Basic Parameters ..................................................................................................................................... 80
7.2.2 Constant Reference ................................................................................................................................. 83
7.2.3 Power Reference ..................................................................................................................................... 85
7.2.4 Torque Reference .................................................................................................................................... 87
7.2.5 Prohibited frequencies ............................................................................................................................ 93
7.2.6 Motor potentiometer .............................................................................................................................. 94
7.2.7 Adjust Reference ..................................................................................................................................... 96
7.3 Ramp control ............................................................................................................................................... 98
7.3.1 Quick Stop ............................................................................................................................................. 100
7.3.2 Ramp Options ....................................................................................................................................... 101
7.4 Input signals .............................................................................................................................................. 103
7.4.1 Basic Settings ........................................................................................................................................ 103
7.4.2 Digital inputs ......................................................................................................................................... 105
7.4.3 Analogue Input 1 & 2 ............................................................................................................................. 111
7.4.4 Analogue input 3 & 4 ............................................................................................................................. 116
7.4.5 Inversion control ................................................................................................................................... 119
7.5 Output signlas ........................................................................................................................................... 120
7.5.1 Digital output signals ............................................................................................................................. 120
7.5.2 Analogue outputs 1 & 2 & 3 & 4 ............................................................................................................ 125
7.5.3 Delayed Digital Output 1 & 2 ................................................................................................................. 129
7.5.4 Supervision limits .................................................................................................................................. 132
7.6 Limit settings ............................................................................................................................................. 134
7.6.1 Current limit handling............................................................................................................................ 134
7.6.2 Power limit handling ............................................................................................................................. 135
7.6.3 Torque limit handling ............................................................................................................................ 139
7.6.4 Frequency limit handling ....................................................................................................................... 143
7.6.5 DC Link handling .................................................................................................................................... 144
7.6.6 Limit options ......................................................................................................................................... 147
7.7 DC current and magnetization handling ..................................................................................................... 148
7.7.1 Open loop settings ................................................................................................................................ 148
7.7.2 Closed loop settings .............................................................................................................................. 152
7.8 Motor Control ........................................................................................................................................... 154
7.8.1 U/f Settings ........................................................................................................................................... 158
7.8.2 Close Loop Settings ............................................................................................................................... 161
7.8.3 Permanent magnet synchronous motor settings .................................................................................... 164
7.8.4 Stabilization settings.............................................................................................................................. 169
7.8.5 Tuning settings ..................................................................................................................................... 172
7.8.6 Identification settings ........................................................................................................................... 174
7.9 Speed Control settings ............................................................................................................................... 175
7.10 Drive Control ............................................................................................................................................. 181
7.11 Master Follower ........................................................................................................................................ 184
7.11.1 Master Follower: Standard system ................................................................................................... 184
7.11.2 Master Follower: DriveSynch system ................................................................................................. 185
apfiff09 marine vacon • 5
24-hour
7.11.3 Master follower configuration ........................................................................................................... 188
7.12 Protections ................................................................................................................................................ 193
7.12.1 General settings ................................................................................................................................ 193
7.12.2 Temperature sensor protections ....................................................................................................... 194
7.12.3 Stall protection ................................................................................................................................. 196
7.12.4 Speed Error ....................................................................................................................................... 198
7.12.5 Motor Protection .............................................................................................................................. 199
7.12.6 Over Load Protection ........................................................................................................................ 202
7.12.7 4mA Protection ................................................................................................................................. 203
7.12.8 Under load protection ....................................................................................................................... 204
7.12.9 Earth Fault ........................................................................................................................................ 206
7.12.10 Cooling protection............................................................................................................................. 206
7.12.11 Fieldbus communication ................................................................................................................... 207
7.12.12 External Fault function ...................................................................................................................... 208
7.12.13 Encoder Fault function ...................................................................................................................... 209
7.13 Fieldbus settings ........................................................................................................................................ 210
7.13.1 General settings ................................................................................................................................ 210
7.14 ID Functions .............................................................................................................................................. 214
7.14.1 Value Control .................................................................................................................................... 214
7.14.2 DIN ID Control ................................................................................................................................... 216
7.14.3 ID-controlled DO ............................................................................................................................... 217
7.14.4 Free DIN Delay .................................................................................................................................. 218
7.15 Brake Control ............................................................................................................................................ 219
7.15.1 Run away load protection.................................................................................................................. 222
7.15.2 Brake monitoring function ................................................................................................................. 223
7.15.3 Closed Loop settings.......................................................................................................................... 224
7.15.4 Roll Back Control for Closed Loop ...................................................................................................... 224
7.16 Auto Fault Reset ........................................................................................................................................ 225
7.17 PI Control .................................................................................................................................................. 228
7.18 Keypad control parameters........................................................................................................................ 230
8. Data Logger Trigger Word ................................................................................................................................. 231
9. Identification function for permanent magnet synchronous motor .................................................................. 232
9.1 Zero position identification with absolute encoder..................................................................................... 232
9.2 Start position with incremental encoder without Z-pulse input. ................................................................. 232
9.3 Identification with incremental encoder with Z-pulse input. ....................................................................... 233
10. Status and control word in detail .................................................................................................................. 234
10.1 Combination 1, ProfiDrive Standard with Profibus option board .............................................................. 235
10.1.1 Control Word Combination 1, ProfiDrive Basic with profibus option board ...................................... 235
10.1.2 Status Word Combination 1, ProfiDrive Basic with profibus option board ........................................ 235
10.2 Combination 2, ByPass ProfiDrive............................................................................................................ 236
10.2.1 State Diagram ................................................................................................................................... 236
10.2.2 State Machine ................................................................................................................................... 237
10.2.3 FB Control Word ............................................................................................................................... 238
10.2.4 FB Status Word ................................................................................................................................. 241
10.3 Combination 3, ByPass Basic ................................................................................................................... 243
10.3.1 Control Word Combination 3, ByPass Basic ..................................................................................... 243
10.3.2 Status Word Combination 3, ByPass Basic ....................................................................................... 243
11. Problem solving ............................................................................................................................................ 244
12. Fault codes .................................................................................................................................................... 246
6 • Vacon apfiff09 marine
Tel. +358
1
1. MARINE APPLICATION - INTRODUCTION
Software APFIFF09, Marine application
Marine application has advanced power handling features, main focus being in different kind
of propulsion systems. Application can be used also for winch control where smooth brake
logic makes it possible to use a multi-motor winch system by just entering few additional
parameter settings that are explained in this manual without forgetting permanent magnet
motors.
1.1 General
This application is not kept backwards compatible. Please read the application change note
or chapter 2: Marine versions compatibility issues, in this manual to see what needs to be
noted when updating the application. See also the updated parameter description in NCDrive
when commissioning.
Help is available in NCDrive through .
Below an example from Identification parameter help text from the NCDrive.
apfiff09 marine vacon • 7
24-
5
1.2 Basic Features
The Marine application provides a wide range of parameters for controlling induction motors
and permanent magnet motors. It can be used for various kinds of different processes
where wide flexibility of I/O signals is needed and only simple PI control logic.
The main focus has been how power reference, power limits and torque limits behave in
different situations. The application allows power and torque reference and reference ramp
up rate adjustment to make the operation smooth for ship generators and mechanics.
Flexible ID control possibilities takes the application suitability to different process to a new
level, allowing any input or actual value to be connected to any parameter with a scaling
factor.
Marine application is not considered to be fast response application. Basic functionality is
handled in 20 ms time level. Most of the inputs and output functions are handled in 30 ms
time level, and analogue output singles are using pre filtered signals (Torque (1 second
linear filtering) , Power, etc.). Power limit functions are handled in 10 ms time level or
faster.
Additional functions:
Joystick input dead zone
Different power limits by DI or from Fieldbus. Motoring and generating side.
Master Follower function for steering propeller and double winding motors
Different torque limits for motoring and generating side
Cooling monitor input from heat exchange unit with selectable response.
Brake monitoring input and actual current monitor for immediate brake close.
Separate speed control tuning for different speeds and loads
Inching function with two different references
Possibility to connect FB Process data to any parameter and some monitoring
values
Analogue input 3 and 4 can control any parameter by ID number.
Support for four analogue output
Support for two PT100 board
Power limit ramp up rate adjustment
Torque limit ramp up rate adjustment
Automatic power reduction from DC Voltage
Actual power follower function, power will increase only with allowed rate
8 • Vacon apfiff09 marine
Tel. +358 5
2
2. MARINE VERSIONS COMPATIBILITY ISSUES
V120
- Temperature measurement board 2 has own response parameter.
V122
- Speed error monitoring status bits are moved from Fault Word 2 to Fault Word 10 B0
and from Warning Word 1 to Warning Word 10 B0
V128
- Earlier version, when operating in Ramp Follower mode, follower brake control
closed the brake after master drive was in stop state. Now brake is closed in this
mode at the same time as master drive is closing the brake.
Note 1: When
download function. Instead upload parameters from the unit and make comparation to old
parameter file. Application is constantly developed, this includes changing parameter
default values, if parameters are directly downloaded to drive, improved default values will
be lost.
apfiff09 marine vacon • 9
24-
3
Jumper block X3:
CMA and CMB grounding
CMB connected to GND
CMA connected to GND
CMB isolated from GND
CMA isolated from GND
CMB and CMA
internally connected together,
isolated from GND
= Factory default
3. CONTROL I/O
NXOPTA1
Terminal
Signal
Description
1
Reference voltage output
Voltage for potentiometer, etc.
2
Analogue input 1.
Range 0-10V, R
i
= 200k
Range 0-20 mA R
i
= 250
Analogue input 1 frequency reference.
Input range selected by jumpers.
Default range: Voltage 0 10 V
3
I/O Ground
Ground for reference and controls
4
Analogue input 2.
Range 0-10V, R
i
= 200k
Range 0-20 mA R
i
= 250
Analogue input 2 frequency reference
Input range selected by jumpers.
Default range: Current 0 20 mA
5
6
Control voltage output
Voltage for switches, etc. max 0.1 A
7
I/O ground
Ground for reference and controls
8
Start forward
Programmable G2.2.7
Contact closed = start forward
Programmable start logic P2.2.1
9
Start reverse
Programmable G2.2.7
Contact closed = start reverse
Programmable logic P2.2.1
10
Fault reset
Programmable G2.2.7
Contact open = no fault
Contact closed = fault
11
CMA
Common for DIN 1 DIN 3
Connect to GND or +24V
12
Control voltage output
Voltage for switches (see #6)
13
I/O ground
Ground for reference and controls
14
Programmable G2.2.7
No function defined at default
15
Programmable G2.2.7
No function defined at default
16
Programmable G2.2.7
No function defined at default
17
Common for DIN4 DIN6
Connect to GND or +24V
18
Analogue output 1
Programmable P2.3.1.2
Output range selected by jumpers.
Range 0 20 mA. R
L
, max. 500
Range 0 10 V. R
L
> 1k
19
20
Digital output
Programmable
Open collector, I50mA, U48 VDC
NXOPTA2
21
Relay output 1
Programmable G2.3.3
Switching capacity
24 VCD / 8 A
250 VAC / 8 A
125 VDC / 0.4 A
22
23
RO1
24
Relay output 2
Programmable G2.3.3
Programmable
No function defined at default
25
26
Table 3-1. Marine application default I/O configuration and
connection example.
Note: See Users Manual, chapter Control Connections, for hardware specification and
configuration.
Note: See jumper selections below.
More information in Vacon NX User's
Manual, Chapter 6.2.2.2.
220
VAC
Reference potentiometer,
mA
10 • Vacon apfiff09 marine
Tel. +358
4
4. PRINCIPLE
The programming principle of the input and output signals in the Multipurpose Control
Application NXP as well as in the Pump and Fan Control Application (and partly in the
other applications) is different compared to the conventional method used in other Vacon NX
applications.
In the conventional programming method,
Function to Terminal Programming Method (FTT),
you have a fixed input or output that you define a certain function for. The applications
mentioned above, however, use the
Terminal to Function Programming method (TTF)
in
which the programming process is carried out the other way round: Functions appear as
parameters which the operator defines a certain input/output for. See
Warning
on page 11.
4.1 Defining an input/output for a certain function on keypad
Connecting a certain input or output with a certain function (parameter) is done by giving the
parameter an appropriate value. The value is formed of the
Board slot
on the Vacon NX
control board (see Vacon NX User's Manual, Chapter 6.2) and the
respective signal number
,
see below.
Function name
Slot Terminal number
Terminal type
Example: You want to connect the digital output function
Reference fault/warning
(parameter 2.3.3.7) to the digital output DO1 on the basic board NXOPTA1 (see Vacon NX
User's Manual, Chapter 6.2).
First find the parameter 2.3.3.7 on the keypad. Press the
Menu button right
once to enter the
edit mode. On the
value line
, you will see the terminal type on the left (DigIN, DigOUT, An.IN,
An.OUT) and on the right, the present input/output the function is connected to (B.3, A.2 etc.),
or if not connected, a value (0.#).
When the value is blinking, hold down the
Browser button up
or
down
to find the desired
board slot and signal number. The program will scroll the board slots starting from 0 and
proceeding from A to E and the I/O selection from 1 to 10.
Once you have set the desired value, press the
Enter button
once to confirm the change.
READY
I/Oterm
DigOUT:B.1
AI Ref Faul/Warn
READY
I/Oterm
DigOUT:0.0
READY
I/Oterm
DigOUT:0.0
READY
I/Oterm
DigOUT:B.1
enter
AI Ref Faul/Warn AI Ref Faul/Warn AI Ref Faul/Warn
apfiff09 marine vacon • 11
24-
4
4.2 Defining a terminal for a certain function with NCDrive programming tool
If you use the NCDrive Programming Tool for parametrizing you will have to establish the
connection between the function and input/output in the same way as with the control panel.
Just pick the address code from the drop-down menu in the
Value
column (see the Figure
below).
Figure 4-1. Screenshot of NCDrive programming tool; Entering the address code
Be ABSOLUTELY sure not to connect two functions to one and same
output in order to avoid function overruns and to ensure flawless
operation.
!
WARNING
Note: The
inputs
, unlike the
outputs
, cannot be changed in RUN state.
12 • Vacon apfiff09 marine
Tel. +358
4
4.3 Defining unused inputs/outputs
All unused inputs and outputs must be given the board slot value 0 and the value 1 also for
the terminal number. The value 0.1 is also the default value for most of the functions.
However, if you want to use the values of a digital input signal for e.g. testing purposes
only, you can set the board slot value to 0 and the terminal number to any number between
contact' and values 2 to 10 to 'closed contact'.
In case of analogue inputs, giving the value 1 for the terminal number corresponds to 0%
signal level, value 2 corresponds to 20%, value 3 to 30% and so on. Giving value 10 for the
terminal number corresponds to 100% signal level.
apfiff09 marine vacon • 13
24-hour support +358 (0
5
5. MARINE APPLICATION MONITORING VALUES
On the next pages you will find the lists of parameters within the respective parameter
groups. The parameter descriptions are given on pages 74 to 224. Parameter description
includes more than is available in this application see parameter list what is available.
Column explanations:
Code = Location indication on the keypad; Shows the operator the present
parameter number
Parameter = Name of parameter
Min = Minimum value of parameter
Max = Maximum value of parameter
Unit = Unit of parameter value; Given if available
Default = Value preset by factory
Cust =
ID = ID number of the parameter
_____ = On parameter code: Parameter value can only be changed after the FC has
been stopped.
_____ = Apply the Terminal to Function method (TTF) to these parameters (see
chapter 4)
_____ = Monitoring value is possible to control from fieldbus by ID number
The manual presents signals that are not normally visible for monitoring. i.e. is not a
parameter or standard monitoring signal. These signals are presented with [Letter]. e.g.
[FW]MotorRegulatorStatus
[V] Normal monitoring signal
[P] Normal parameter in application.
[FW] Firmware signal, Can be monitored with NCDrive when signal type is selected
Firmware
[A] Application signal, can be monitored with NCDrive when signal type is selected
Application.
[R] Reference type parameter on keypad.
[F] Function. Signal is received as a output of function.
[DI] Digital input signal.
14 • Vacon apfiff09 marine
Tel. +358
5
5.1 Monitoring values
The monitoring values are the actual values of parameters and signals as well as statuses
and measurements.
Note for DriveSynch Systems:
In a DriveSynch system, only Master drive monitoring signals are reliable.
Only directly measured values are reliable in follower units. Even the Output Frequency of
DriveSynch follower is not directly observed and thus may not show actual output frequency
that is controlled by DriveSynch Master Drive.
Code
Parameter
Unit
Form.
ID
Description
V1.1
Output frequency
Hz
#,##
1
Output frequency to motor
V1.2
Frequency reference
Hz
#,##
25
Frequency reference to motor control
V1.3
Motor speed
rpm
#
2
Motor speed in rpm
V1.4
Motor current
A
Varies
3
1 s linear filtering
V1.5
Motor torque
%
#,#
4
In % of Motor nominal torque
V1.6
Motor Power
%
#,#
5
V1.7
Motor voltage
V
#,#
6
Calculated motor voltage
V1.8
DC link voltage
V
#
7
Measured DC voltage, filtered.
V1.9
Unit temperature
C
#
8
Heatsink temperature
V1.10
Motor temperature
%
#
9
Calculated motor temperature, trip 105 %
V1.11
Analogue input 1
%
#,##
13
AI1, unfiltered.
V1.12
Analogue input 2
%
#,##
14
AI2, unfiltered.
V1.13
Analogue input 3
%
#,##
27
AI3, unfiltered.
V1.14
Analogue input 4
%
#,##
28
AI4, unfiltered.
V1.15
Analogue Out 1
%
#,##
26
AO1
V1.16
Analogue Out 2
%
#,##
31
AO2
V1.17
Analogue Out 3
%
#,##
32
AO3
V1.18
Analogue Out 4
%
#,##
1526
V1.19
DIN1, DIN2, DIN3
15
Digital input statuses
V1.20
DIN4, DIN5, DIN6
16
Digital input statuses
V1.21
Power Reference
%
#,#
1700
Used power reference
V1.22
PT-100 Temperature
#,#
42
Highest temperature of OPTB8 board. 4 s
filtering.
G1.23
Multimonitoring items
Displays three selectable monitoring
values
Table 5-1. Monitoring values
apfiff09 marine vacon • 15
24-hour support +358 (0
5
5.1.1
Monitoring values 2
Code
Parameter
Unit
Form.
ID
Description
V1.24.1
Current
A
Varies
1113
Unfiltered motor current
V1.24.2
Torque
%
#,#
1125
Unfiltered motor torque
V1.24.3
DC Voltage
V
#
44
Unfiltered DC link voltage
V1.24.4
Application Status
Word
43
V1.24.5
Shaft Frequency
Hz
#,##
1124
Unfiltered
V1.24.6
Output Power
kw
Varies
1508
Unfiltered electrical power
V1.24.7
Measured
temperature 1
#,#
50
4 s filtering.
V1.24.8
Measured
temperature 2
#,#
51
4 s filtering.
V1.24.9
Measured
temperature 3
#,#
52
4 s filtering.
V1.24.10
Measured
temperature 4
#,#
69
4 s filtering.
V1.24.11
Measured
temperature 5
#,#
70
4 s filtering.
V1.24.12
Measured
temperature 6
#,#
71
4 s filtering.
V1.24.13
ABS Encoder
Revolutions
r
#
55
V1.24.14
ABS Encoder Position
#
54
V1.24.15
Step response
Hz
#,##
1132
V1.24.16
CosPhiiActual
#,###
68
V1.24.17
Flux Current
%
#,#
72
V1.24.18
Regulator Status
77
V1.24.19
Frequency Delta
Hz/s
1847
V1.24.20
Data Logger Trigger
Word
97
Different status bits to help
diagnostic with data logger.
V1.24.21
Encoder 2 Frequency
Hz
53
V1.24.22
Operation Hours
h
1856
V1.24.23
Status Word 2
89
V1.24.24
Rotor Flux
%
#,#
1158
Table 5-2. Monitoring values 2
16 • Vacon apfiff09 marine
Tel. +358
5
5.1.2
FieldBus Monitoring values
Code
Parameter
Form.
ID
Description
V1.25.1
FB Control Word
1160
V1.25.2
FB Status Word
65
V1.25.3
FB Torque Reference
#,#
1140
Default Control of FB PD 1
V1.25.4
FB Limit Scaling
#,##
46
Default Control of FB PD 2
V1.25.5
FB Adjust Reference
#,##
47
Default Control of FB PD 3
V1.25.6
FB Analogue Output
#,##
48
Default Control of FB PD 4
V1.25.7
FB Motor Current
#,#
45
Motor current (drive
independent) given with one
decimal point
V1.25.8
Fault Word 1
1172
V1.25.9
Fault Word 2
1173
V1.25.10
Warning Word 1
1174
V1.25.11
AuxStatusWord
1163
V1.25.12
FB Power Reference
1703
V1.25.13
Last Active Fault
37
V1.25.14
AuxControlWord
1161
V1.25.15
Din Status Word
56
V1.25.16
Din Status Word 2
57
V1.25.17
MC Status
64
V1.25.18
Last Active Warning
74
V1.25.19
Shaft Rounds
1170
V1.25.20
Shaft Angle
1169
V1.25.21
Fault Word 10
1202
V1.25.22
Warning Word 10
1269
Table 5-3. FieldBus Monitoring values
5.1.3
Master/Follwer Monitoring values
Code
Parameter
Form.
ID
Description
V1.26.1
SB SystemStatus
1601
V1.26.2
Total Current
#,#
80
Sum current of all drives (DS)
V1.26.3
Master CW
93
Code
Parameter
ID
Description
V1.26.4.1
Motor Current D1
1616
V1.26.4.2
Motor Current D2
1605
V1.26.4.3
Motor Current D3
1606
V1.26.4.4
Motor Current D4
1607
Code
Parameter
ID
Description
V1.26.5.1
Status Word D1
1615
V1.26.5.2
Status Word D2
1602
V1.26.5.3
Status Word D3
1603
V1.26.5.4
Status Word D4
1604
Table 5-4. Master/Follower Monitoring values
5.1.4
PI Control Monitoring values
Code
Parameter
Form.
ID
Description
V1.27.1
PI Reference
20
Used PI Reference
V1.27.2
PI Actual Value
21
PI Actual value
V1.27.3
PI Output
23
PI Output before scaling
V1.27.3
PI Output Scaled
1807
Scaled PI Output
This is used for ID connection
apfiff09 marine vacon • 17
24-hour support +358 (0
5
5.1.5
Frequency Chain
Code
Parameter
Form.
ID
Description
V1.28.1
Frequency Reference 1
1126
V1.28.2
Frequency Reference 2
1127
V1.28.3
Frequency Reference
Actual
1128
V1.28.4
Frequency Ramp Out
1129
V1.28.5
Frequency Reference
Final
1131
V1.28.6
Encoder Frequency
1164
5.1.6
Torque Chain
Code
Parameter
Form.
ID
Description
V1.29.1
Torque Reference
18
V1.29.2
Torque Reference 3
1144
V1.29.3
Torque Ref Final
1145
V1.29.4
Speed Control Out
1134
V1.29.5
Torque Reference Actual
1180
5.1.7
Active Limits
Code
Parameter
Form.
ID
Description
V1.30.1
Motoring Torque Limit
1950
V1.30.2
Generator Torque Limit
1951
V1.30.3
Motoring Power Limit
1952
V1.30.4
Generator Power Limit
1953
V1.30.5
Current Limit
1954
V1.30.6
SPC Positive Limit
1955
V1.30.7
SPC Negative Limit
1956
18 • Vacon apfiff09 marine
Tel. +358
5
5.2 Monitoring values description
Note for DriveSynch Systems:
In a DriveSynch system, only Master drive monitoring signals are reliable.
Only directly measured values are reliable in follower units. Even the Output Frequency of
DriveSynch follower is not directly observed and thus may not show actual output frequency
that is controlled by DriveSynch Master Drive.
V1.1 Output frequency [#,## Hz] ID1
Output frequency to motor, updated at 10 ms time level.
V1.2 Frequency reference [#,## Hz] ID 25
Frequency reference to motor control, after speed share function. updates at 1
ms time level.
V1.3 Motor speed [ # rpm] ID 2
Motor speed in rpm
V1.4 Motor current [A] ID 3
Open loop:
1 s linear filtering.
Closed Loop:
32 ms filtering
Drive Synch Operation Master drive
This value is the total current of the system divided by number of drives in the
system (SbLastID). SbLastId cannot be changed; it needs to be set according to
how many drives are linked with system bus.
Drive Synch Operation Follower drive
This value is the current of the drive own power unit.
Current scaling in different size of units
Note: ID45, usually in Process data OUT 3 is scaled to be with one decimal
always.
Voltage
Size
Scale
208 240 Vac
NX0001 NX0011
100 0,01A
208 240 Vac
NX0012 NX0420
10 0,1A
208 240 Vac
NX0530
1 1A
380 500 Vac
NX0003 NX0007
100 0,01A
380 500 Vac
NX0009 NX0300
10 0,1A
380 500 Vac
NX0385 NX2643
1 1A
525 690 Vac
NX0004 NX0013
100 0,01A
525 690 Vac
NX0018 NX0261
10 0,1A
525 690 Vac
NX0325 NX1500
1 1A
apfiff09 marine vacon • 19
24-hour support +358 (0
5
V1.5 Motor torque % ID 4
In % of Motor nominal torque
Open loop
1 s linear filtering
Closed Loop
32 ms filtering
Drive Synch Operation Follower drive
calculated in open loop. Motor
torque is valid only in Master drive.
V1.6 Motor Power % ID 5
Calculated motor power
V1.7 Motor voltage V ID 6
Calculated motor voltage
V1.8 DC link voltage V ID 7
Measured DC voltage, filtered.
V1.9 Unit temperature ID 8
Heatsink temperature
V1.10 Motor temperature % ID 9
Calculated motor temperature
105 % is tripping limit if response is fault.
V1.11 Analogue input 1 % ID 13
V1.12 Analogue input 2 % ID 14
Unfiltered analogue input level.
0 % = 0 mA / 0 V, -100 % = -10 V, 100 % = 20 mA / 10 V.
Monitoring scaling is determined by the option board parameter.
V1.13 Analogue input 3 % ID 27
V1.14 Analogue input 4 % ID 28
It is possible to adjust this input value from fieldbus when the input terminal
selection is 0.1. This way it is possible to adjust the free analogue input from
fieldbus and have all analogue input functions available for fieldbus process
data.
20 • Vacon apfiff09 marine
Tel. +358
5
V1.15 Analogue Out 1 % ID 26
V1.16 Analogue Out 2 % ID 31
V1.17 Analogue Out 3 % ID 32
V1.18 Analogue Out 4 % ID 1526
Analogue Output value 0 % = 0 mA / 0 V, 100 % = 20 mA / 10 V
V1.19 DIN1, DIN2, DIN3 ID 15
V1.20 DIN4, DIN5, DIN6 ID 16
DIN1/DIN2/DIN3 status
DIN4/DIN5/DIN6 status
b0
DIN3
DIN6
b1
DIN2
DIN5
b2
DIN1
DIN4
V1.21 Power reference % ID 1700
Power reference monitoring value. If power reference is not selected in the
reference group it can be directly written to this monitoring variable from
fieldbus and only ramping rate function is active from power reference group.
V1.22 PT-100 Temperature ID 42
Highest temperature of OPTB8 board. 4 s filtering.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258

Vacon NX Series User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI