DRAKE DAR8642 Quick Manual

Category
Video line amplifiers
Type
Quick Manual

This manual is also suitable for

®
Rack Mount Distribution Amplifiers, with Power Doubled Hybrid Output 1
DESCRIPTION
The R.L. DRAKE models DAR8642, DAR8633, DAR8618,
DAR7542, and DAR7533, are broadband distribution
amplifiers designed for indoor headend use in both
residential and commercial buildings where RF signal
distribution in the frequency range of 54 to 860 MHz is
required. Each model, except the DAR8618, incorporates a
push-pull hybrid input preamp and a power doubled hybrid
output amplifier to provide a very low distortion signal for
launch amp applications in the output of an SMATV or CATV
headend. The Gain and Slope controls both have a range of
10 dB minimum and operate between the preamp hybrid
and the output hybrid to maintain a low noise figure over a
wide range of gain and slope settings. Only the DAR8618
has a power doubled output hybrid with no input preamp and
no adjustable gain and slope controls. All models have a
provision for optional fixed input attenuators and equalizers.
Double-sided, plated through hole, glass epoxy, printed
circuit boards, and SMT are used for low losses and
maximum reliability.
All DAR models include a built-in diplexer filter. This allows
the return path energy that is present at the output port of
the DAR to be separated from the DAR output and passed
to the return path output port.
Input and output test connectors are provided for convenient
monitoring of the signal path. The amplifier circuitry is
designed for maximum stability, low distortion, low noise
figure, and is protected in a rugged aluminum housing.
- The unit operates from a nominal 115 VAC, 60 Hz input.
- Input equalizer and fixed attenuator options are available.
GAIN SLOPE
DAR DISTRIBUTION AMPLIFIER
INPUT MONITOR
-30 dB
POWER
OUTPUT MONITOR
-30 dB
MIN. MAX.
MIN. FLAT
F1 - POWER LED
This indicator illuminates when power is supplied to the unit.
F2 - INPUT MONITOR
This connector may be used to monitor input to the DAR.
The levels will be 30 dB below the input levels at R3.
F3 - GAIN*
Adjusts the amplifier interstage attenuator.
F4 - SLOPE*
Adjusts the slope of the output signal.
F5 - OUTPUT MONITOR
This connector may be used to monitor the output of the
DAR. Levels will be 30 dB below those present at R2.
R2 must be terminated in 75 Ohms for an accurate reading.
*
Not present on models with gain below 20 dB.
F1 F2 F3 F4 F5
2 Rear Panel Connections
FUSE
RETURN PATH
OUTPUT
RF OUTPUT
RF INPUT
FUSE
1/2 A , 250 V SLO - BLO
115 VAC , 60 Hz
40 WATTS
R1 - RETURN PATH OUTPUT
Any return path signals from 5 to 42 MHz that are present at
R2 will be passed to this port.
R2 - RF OUTPUT
This is the RF output for CATV distribution and is the
amplified output of channels that are input to port R3 from
54 MHz and higher. At this port, any return path channels
from 5 to 42 MHz will be passed at unity gain to port R1.
R3 - RF INPUT
This connector accepts the RF input from a headend
combiner output, 54 MHz and higher.
R4 - FUSE
If necessary, replace this fuse only with a fuse of the same
indicated rating.
R5 - AC LINE CORD
Connect this line cord to a 115 V / 60 Hz AC power source.
R1 R2 R3 R4 R5
Installation 3
INSTALLATION
1) Unpack the distribution amplifier.
2) Mount the amplifier in the desired location in the rack. Be
sure to leave at least one open rack space above and below
the amp to allow proper ventillation.
3) Connect input and output cables to the amplifier.
4) Plug the power line cord into a 115 VAC/60 Hz power
source.
5) Preset slope control fully clockwise.
6) While monitoring the output levels at the Output Monitor
-30 dB test port, adjust the Gain control for desired output at
the high end of the band. Then monitor the lowest channel
and adjust slope control to equalize this channel to the
desired level (usually equal to but not higher than the high
end of the band). Since there can be a slight interaction
between the slope and gain settings, it is advised to repeat
this step a few times to ensure the desired levels are
attained.
NOTE: The -30 dB input and output test ports can be used
to monitor input and output levels. These are only accurate
when the load is connected to the amplifier output and
power is on.
A WORD CONCERNING INPUT LEVELS
It is important to keep the input level to the amplifier within
an optimum range. If the level is too high, higher nonlinear
distortion will result and if the level becomes too low, C/N
might be less than desired. As a general rule, stay within
the optimum input level range listed in the specifications.
The listed levels assume a fully loaded channel complement.
Higher levels may be used if the channel loading is less.
In general, install a fixed input attenuator if required to set
the highest frequency channels in the input to within the
optimum range. Then set the amplifier gain to achieve the
desired output level, not to exceed the maximum output level
listed in the specifications. Then, if the low frequency
channels are above the optimum input level range, a fixed
input equalizer can be installed to drop the low frequency
channels to within this range. Use the slope control to make
fine adjustments.
FIXED INPUT ATTENUATOR
LOCATION
A factory installed jumper is
installed here for no
attenuation. To install an
input attenuator, remove
jumper and plug in a "SXP"
type attenuator rated for the
same or higher frequency as
the amplifier.
OUT
INSTALLING FORWARD PATH INPUT ATTENUATOR
Remove top cover as described below. If input levels are
enough to cause a high distortion level in the input amplifier,
a fixed input attenuator may be added. Choose an SXP type
attenuator of the value required, and install at the location
indicated below. Remove the 0 dB wire jumper to allow
insertion of the attenuator.
INSTALLING AN INPUT EQUALIZER
Follow the same basic procedure as described above for the
input attenuator except that the equalizer is installed at the
equalizer location shown below:
RF INPUT OF REAR PANEL
GROUND
INPUT EQUALIZER
LOCATION
A factory installed jumper is
installed here for no
equalization. Install desired
"QSA" type equalizer here. If
equalizer is not used, the
jumper must be connected
between the IN and OUT
connections.
IN OUT
GROUND
IN
4 Specifications and Warranty
Forward Gain Adjustment Range:
Slope Control Adjustment (54 MHz):
Input/Output Impedances:
Input and Output Monitor Ports:
Fixed Input Attenuator:
Fixed Input Equalizer:
Hum Modulation:
Frequency Coverage (return port):
RF Shielding:
10 dB minimum (except DAR8618).
10 dB minimum (except DAR8618).
75 Ohms.
- 30 dB.
Plug-in (SXP type) available.
Plug-in (QSA type) available.
- 70 dB.
5 to 42 MHz.
Leakage complies with FCC Part 76.
Frequency Coverage (forward path):
Forward Gain:
Noise Figure:
Return Loss, Input & Output:
Channel Loading:
Output Level (maximum per channel
for distortions listed below):
Input Level (maximum without using
fixed input attenuator):
Optimum Input Level Range
for Best Performance:
Nonlinear Distortions-
Composite Triple Beat:
Composite Second Order:
Cross-modulation:
DAR7533
54 to 750 MHz.
33 dB.
7 dB maximum.
14 dB.
110 CH.
+44 dBmV.
+20 dBmV.
+10 dBmV to
+15 dBmV.
- 58 dB.
- 58 dB.
- 60 dB.
DAR7542
54 to 750 MHz.
42 dB.
6.5 dB maximum.
14 dB.
110 CH.
+44 dBmV.
+10 dBmV.
+0 dBmV to
+5 dBmV.
- 58 dB.
- 58 dB.
- 60 dB.
® is a registered trademark of the R.L. Drake Company © Copyright 2001 R.L. Drake Company P/N: 3852719C-11-2001 Printed in the U.S.A.
R.L. DRAKE COMPANY
230 INDUSTRIAL DRIVE
FRANKLIN, OHIO 45005 U.S.A.
CUSTOMER SERVICE AND PARTS TELEPHONE: +1 (937) 746-6990
TELEFAX: +1 (937) 743-4576
WORLD WIDE WEB SITE: http://www.rldrake.com
®
Power Requirement:
Operating
Temperature Range:
Size:
Weight:
Models DAR7533, 7542, 8633, 8642 -
115 VAC, 60 Hz, 24 Watts;
Model DAR8618 -
115 VAC, 60 Hz, 18 Watts.
- 20 deg. to + 60 deg. C.
19.00" (48.3 cm) W x 7.5" (19.1 cm) D
x 1.75" (4.5 cm) H.
6 lbs. 4 oz. (2.9 Kg).
DAR8633
54 to 860 MHz.
33 dB.
7.5 dB maximum.
14 dB.
129 CH.
+40 dBmV.
+18 dBmV.
+7 dBmV to
+12 dBmV.
- 60 dB.
- 60 dB.
- 64 dB.
DAR8642
54 to 860 MHz.
42 dB.
7 dB maximum.
14 dB.
129 CH.
+40 dBmV.
+7 dBmV.
-3 dBmV to
+2 dBmV.
- 60 dB.
- 60 dB.
- 64 dB.
THREE YEAR LIMITED WARRANTYTHREE YEAR LIMITED WARRANTY
THREE YEAR LIMITED WARRANTYTHREE YEAR LIMITED WARRANTY
THREE YEAR LIMITED WARRANTY
R.L. DRAKE COMPANY warrants to the original purchaser this product shall be free from defects in material or workmanship for three (3) years from
the date of original purchase. During the warranty period the R.L. DRAKE COMPANY or an authorized Drake service facility will provide, free of charge,
both parts and labor necessary to correct defects in material and workmanship. At its option, R.L. DRAKE COMPANY may replace a defective unit.
- To obtain such warranty service, the original purchaser must:
(1)(1)
(1)(1)
(1) Retain invoice or original proof of purchase to establish the start of the warranty period.
(2)(2)
(2)(2)
(2) Notify the R.L. DRAKE COMPANY or the nearest authorized service facility, as soon as possible after discovery of a possible defect, of:
(a) the model and serial number,
(b) the identity of the seller and the approximate date of purchase; and
(c) A detailed description of the problem, including details on the electrical connection to associated equipment and the list of such equipment.
(3)(3)
(3)(3)
(3) Deliver the product to the R.L. DRAKE COMPANY or the nearest authorized service facility, or ship the same in its original container or equivalent,
fully insured and shipping charges prepaid.
- Correct maintenance, repair, and use are necessary to obtain proper performance from this product. Therefore carefully read the
Instruction Manual. This warranty does not apply to any defect that R.L. DRAKE COMPANY determines is due to:
(1)(1)
(1)(1)
(1) Improper maintenance or repair, including the installation of parts or accessories that do not conform to the quality and specifications of the original
parts.
(2)(2)
(2)(2)
(2) Misuse, abuse, neglect or improper installation.
(3)(3)
(3)(3)
(3) Accidental or intentional damage.
- All implied warranties, if any, including warranties of merchantability and fitness for a particular purpose, terminate three (3) years from the date of
the original purchase.
- The foregoing constitutes R.L. DRAKE COMPANY’S entire obligation with respect to this product, and the original purchaser shall have no other
remedy and no claim for incidental or consequential damages, losses or expenses. Some states do not allow limitations on how long an implied warranty
lasts or do not allow the exclusions or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you.
- This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty shall be construed under
the laws of Ohio.
ADDITIONAL SPECIFICATIONS FOR SPECIFIC MODELS
SPECIFICATIONS COMMON TO ALL MODELS (unless otherwise noted)
DAR8618
54 to 860 MHz.
18 dB.
7.5 dB maximum.
14 dB.
129 CH.
+40 dBmV.
+22 dBmV.
N/A
- 61 dB.
- 60 dB.
- 68 dB.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DRAKE DAR8642 Quick Manual

Category
Video line amplifiers
Type
Quick Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI